| Sl No | Description | Qty | Unit | The Trikuta Engineer L5 | M/s MAHASHAKTI ELECTRICAL WORKS L3 | VEENA CONSTRUCTION CO. L4 | M/s R.P Electronics and Electricals Company L2 | M/S A A ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00Augmentation of 11/0.433kV, 25KVA to 63KVA , 3-phase Distribution Substation | ||||||||
| 1.01 | 11/0.433 KV, 3 Phase Distribution Transformer with Bi-mettalic Terminal Connectors Energy Level-2( Alluminum wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings), and with LV Cable Box Having detachable Aluminium Gland plate . | 1 | No | 2,00,000 ₹2,00,000 | 1,77,000 ₹1,77,000 | 1,45,000 ₹1,45,000 Lowest | 1,50,000 ₹1,50,000 | 1,50,000 ₹1,50,000 |
| 1.02 | 50mm2/2x50mm2/2x185mm2/2x240mm2 Single Phase Cable, 1.1KV Grade, PVC Insulated Stranded Conductor FRLS type | 44 | Mtr | 185 ₹8,140 | 190 ₹8,360 | 220 ₹9,680 | 450 ₹19,800 | 125 ₹5,500 Lowest |
| 1.04 | LT Distribution Box for 63/100/250/400 KvA DTR with MCCB for incomer and Switch Fuse Units for outgoing circuits.. | 1 | No | 20,000 ₹20,000 | 29,000 ₹29,000 | 22,000 ₹22,000 | 50,000 ₹50,000 | 12,000 ₹12,000 Lowest |
| 1.06 | Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. | 3 | No | 2,500 ₹7,500 | 3,500 ₹10,500 | 2,000 ₹6,000 | 1,500 ₹4,500 Lowest | 2,500 ₹7,500 |
| 1.08 | 11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type | 1 | Set | 9,000 ₹9,000 | 9,000 ₹9,000 | 8,000 ₹8,000 Lowest | 9,500 ₹9,500 | 9,000 ₹9,000 |
| 1.10 | 11KV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | 3,500 ₹3,500 Lowest | 6,000 ₹6,000 | 5,500 ₹5,500 | 5,500 ₹5,500 | 4,000 ₹4,000 |
| 1.12 | 9Mtr. Long Poles (ST-410 SP 33) | 2 | No | 18,000 ₹36,000 | 19,000 ₹38,000 | 16,500 ₹33,000 | 19,500 ₹39,000 | 16,000 ₹32,000 Lowest |
| 1.14 | Gapless Surge Arrestor, 9KV, 10KA, LA with Polymer housing stn. Type | 1 | Set | 3,000 ₹3,000 Lowest | 7,000 ₹7,000 | 5,500 ₹5,500 | 6,000 ₹6,000 | 4,000 ₹4,000 |
| 1.16 | Cement Bottoming 1:2:4 mix as per REC Standards .5 cum/pole | 2 | No | 1,200 ₹2,400 Lowest | 1,500 ₹3,000 | 2,000 ₹4,000 | 2,500 ₹5,000 | 1,500 ₹3,000 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
24 Jul 2025, 3:00 pmClosed
Executive Engineer, ED-III
Office of the Executive Engineer, ED-III
Fixing of Rate Contract for Augmentation of Sub Stations from 25 KVA to 63 KVA 63KVA to 100KVA 100KVAto 250 KVA and250KVAto400KVACapacity on turnkey basis under the jurisdiction of JPDCL Electric DivIII Jammu for the financial year 2025-26
2025_PDD_279206_1
ED-III/Jammu/20 of 2025-26
Open Tender
Electrical Works
Item Rate
2 days
Jurisdiction Of Electric Division-III
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Executive Engineer, ED-III
₹30,000
6 Sept 2025
3 Jul 2025
25 Jul 2025
3 Jul 2025
24 Jul 2025
3 Jul 2025
Amount
Augmentation of 11/0.433kV, 25KVA to 63KVA , 3-phase Distribution Substation
11/0.433 KV, 3 Phase Distribution Transformer with Bi-mettalic Terminal Connectors Energy Level-2( Alluminum wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings), and with LV Cable Box Having detachable Aluminium Gland plate .
50mm2/2x50mm2/2x185mm2/2x240mm2 Single Phase Cable, 1.1KV Grade, PVC Insulated Stranded Conductor FRLS type
LT Distribution Box for 63/100/250/400 KvA DTR with MCCB for incomer and Switch Fuse Units for outgoing circuits..
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11KV Horn Gap Fuse Set 3 Phase 200A
9Mtr. Long Poles (ST-410 SP 33)
Gapless Surge Arrestor, 9KV, 10KA, LA with Polymer housing stn. Type
Cement Bottoming 1:2:4 mix as per REC Standards .5 cum/pole
Description of Work / Item(s)
Amount
Augmentation of 11/0.433kV, 63 KVA to 100 KVA , 3-phase Distribution Substation
11/0.433 KV, 3 Phase Distribution Transformer with Bi-mettalic Terminal Connectors Energy Level-2( Alluminum wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings), and with LV Cable Box Having detachable Aluminium Gland plate .
50mm2/2x50mm2/2x185mm2/2x240mm2 Single Phase Cable, 1.1KV Grade, PVC Insulated Stranded Conductor FRLS type
LT Distribution Box for 63/100/250/400 KvA DTR with MCCB for incomer and Switch Fuse Units for outgoing circuits..
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11KV Horn Gap Fuse Set 3 Phase 200A
9Mtr. Long Poles (ST-410 SP 33)
Gapless Surge Arrestor, 9KV, 10KA, LA with Polymer housing stn. Type
Cement Bottoming 1:2:4 mix as per REC Standards .5 cum/pole
Description of Work / Item(s)
Amount
Augmentation of 11/0.433kV, 100 KVA to 250 KVA , 3-phase Distribution Substation
11/0.433 KV, 3 Phase Distribution Transformer with Bi-mettalic Terminal Connectors Energy Level-2( Alluminum wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings), and with LV Cable Box Having detachable Aluminium Gland plate .
50mm2/2x50mm2/2x185mm2/2x240mm2 Single Phase Cable, 1.1KV Grade, PVC Insulated Stranded Conductor FRLS type
Transformer Bed
LT Distribution Box for 63/100/250/400 KvA DTR with MCCB for incomer and Switch Fuse Units for outgoing circuits..
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11KV Horn Gap Fuse Set 3 Phase 200A
9Mtr. Long Poles (ST-410 SP 33)
Gapless Surge Arrestor, 9KV, 10KA, LA with Polymer housing stn. Type
Cement Bottoming 1:2:4 mix as per REC Standards .5 cum/pole
Description of Work / Item(s)
Amount
Augmentation of 11/0.433kV, 250 KVA to 400 KVA , 3-phase Distribution Substation
11/0.433 KV, 3 Phase Distribution Transformer with Bi-mettalic Terminal Connectors Energy Level-2( Alluminum wound upto 200KVA, Copper wound for 250KVA or higher KVA ratings), and with LV Cable Box Having detachable Aluminium Gland plate .
50mm2/2x50mm2/2x185mm2/2x240mm2 Single Phase Cable, 1.1KV Grade, PVC Insulated Stranded Conductor FRLS type
Transformer Bed
LT Distribution Box for 63/100/250/400 KvA DTR with MCCB for incomer and Switch Fuse Units for outgoing circuits..
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11KV Horn Gap Fuse Set 3 Phase 200A
9Mtr. Long Poles (ST-410 SP 33)
Gapless Surge Arrestor, 9KV, 10KA, LA with Polymer housing stn. Type
Cement Bottoming 1:2:4 mix as per REC Standards .5 cum/pole
VEENA CONSTRUCTION CO. (BID ID -2417914)
M/s MAHASHAKTI ELECTRICAL WORKS (BID ID -2417921)
M/s R.P Electronics and Electricals Company (BID ID -2418162)
The Trikuta Engineer (BID ID -2405979)
VEENA CONSTRUCTION CO. (BID ID -2417914)
M/s MAHASHAKTI ELECTRICAL WORKS (BID ID -2417921)
M/s R.P Electronics and Electricals Company (BID ID -2418162)
The Trikuta Engineer (BID ID -2405979)
VEENA CONSTRUCTION CO. (BID ID -2417914)
M/s MAHASHAKTI ELECTRICAL WORKS (BID ID -2417921)
The Trikuta Engineer (BID ID -2405979)
M/s R.P Electronics and Electricals Company (BID ID -2418162)
M/s R.P Electronics and Electricals Company (BID ID -2418162)
M/s MAHASHAKTI ELECTRICAL WORKS (BID ID -2417921)
VEENA CONSTRUCTION CO. (BID ID -2417914)
The Trikuta Engineer (BID ID -2405979)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .