| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹56.4 L+₹15.2 L (36.9%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹59.2 L+₹17.9 L (43.4%)Rejected-Finance JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹93,080
Closing Date
30 May 2023, 6:00 pmClosed
GE (UTILITIES)
GE (UTILITIES) UDHAMPUR, PO-GARHI, PIN-182121
Special repair to Electric infrastructure, provn of area lightning, provn of 01x60 HP Centrifugal pump for RAW water set and installation of water purifier (150 LPH) under GE (Utilities)Udhampur
2023_MES_592805_1
GE/U- /2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (UTILITIES) UDHAMPUR
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹93,080
Yes
19 Aug 2023
2 May 2023
1 Jun 2023
2 May 2023
30 May 2023
16 May 2023
Amount
Supply & fix for XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 400 sq mm ,3.5 core, laid in trenches/ ducts/through pipe complete all as specified and directed by Engr-in-Charge.
Supply & fix for XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 300 sq mm ,3.5 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge.
Supply & fix for XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 150 sq mm ,3.5 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engr-in-Charge.
Supply and Laying and fixing in replacement of along the poles or passing through pipes or laid under floor of through walls etc jointing and testing LT Cross Linked Polythene Insulated (XLPE insulated) galvanized steel strip armoured electric cable 1100 volt grade heavy duty 95 sqmm 3.5 core ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional area as under including taking out old UNSV LT cables complete all as specified and directed by Engr-in-Charge. Note : Excavation, earthwork, Pipe for cable protection to be measured and paid for separately.
All as per serial item No 4.00 here-in-before but of size 35 sqmm 3.5 core.
All as per serial item No 4.00 here-in-before but of size 25 sqmm 3.5 core.
All as per serial item No 4.00 here-in-before but of size 25 sq mm,4 core.
All as per serial item No 4.00 here-in-before but of size 16 sq mm ,4 core.
All as per serial item No 4.00 here-in-before but of size 10 Sqmm 4 core.
Supply and lay DWC (Double wall corruguated) pipe attachments like coupler, snap-fit and any additional attachments suitable for DWC pipe of 200/174 mm conforming to IS: 14930/ IS 16205 for protection of LT Cable 400 sqmm complete all as specified and directed by Engr-in-Charge.
Supply and lay DWC (Double wall corruguated) pipe attachments like coupler, snap-fit and any additional attachments suitable for DWC pipe of 180/152 mm conforming to IS: 14930/ IS 16205 for protection of LT Cable 300 sq mm complete all as specified and directed by Engr-in-Charge.
Supply and lay DWC (Double wall corruguated) pipe attachments like coupler, snap-fit and any additional attachments suitable for DWC pipe of 120/103 mm conforming to IS: 14930/ IS 16205 for protection of LT Cable 150 sq mm complete all as specified and directed by Engr-in-Charge.
Supply and lay DWC (Double wall corruguated) pipe attachments like coupler, snap-fit and any additional attachments suitable for DWC pipe of 77/63 mm conforming to IS: 14930/ IS 16205 for protection of LT Cable 25 sq mm complete all as specified and directed by Engr-in-Charge.
Supply and lay DWC (Double wall corruguated) pipe77 mm conforming to IS: 14930/ IS 16205 for protection of earth strip including necessary snap-fit coupler required for fixing complete all as specified and directed by Engr-in-Charge.
Supply and lay DWC (Double wall corruguated) pipe 50x38 mm conforming to IS: 14930/ IS 16205 for protection of earth strip including necessary snap-fit coupler required for fixing complete all as specified and directed by Engr-in-Charge .
Supply and lay DWC (Double wall corruguated) pipe attachments like coupler, snap-fit and any additional attachments suitable for DWC pipe of 40/32 mm conforming to IS: 14930/ IS 16205 for protection of LT Cable 16 sq.mm all as specified and directed by Engr-in-Charge.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr in depth for laying of under ground cable and getting out in soft/ loose soil complete all as specified and directed by Engr-in-Charge.
All as per serial item No 17.00 here-in-before but depth exceeding 1.5m but not exceeding 3m complete all as specified and directed by Engr-in-Charge.
Returning filling in excavated soil in trenches including spreading , levelling, watering and well ramming in layers n exc 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing of excavated soil to a distance n exc 50mtr and deposited where directed at a level not exceeding 1.5 mtr above starting point complete all as specified & directed by Engr-in-Charge.
Supply & fix Air breaker switch gang operated trple pole, mechanically operated mounted on insulator and steel frame with operating mechanisom worked from ground level, for current rating upto 200 Amps , 11000 volts icluding drop out out fuse unit complete all as specified & directed by Engr-in-Charge .
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder changeover pillar box out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) Onload changeover switch 630 amps, 4 pole, 35 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 01 Nos. (b) Bus bar electrolytic grade Aluminium 1000Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing (a) MCCB 315 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-1 Nos. (b) MCCB 250 amps, 4 pole,25 KA with adjustable thermal over load release 50 Hz, 415 volts grade -02 Nos. (c) MCCB 63 amps, 4 pole,25 KA with adjustable thermal over load release 50 Hz, 415 volts grade -02 Nos. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connection of cables ,connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder changeover pillar box out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) Onload changeover switch 250 amps, 4 pole, 35 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 01 Nos. (b) Bus bar electrolytic grade Aluminium 400Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing:- (a) MCCB 250 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-01 Nos. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connection of cables ,connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder changeover pillar box out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) Onload changeover switch 630 amps, 4 pole, 35 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 02 Nos. (b) Bus bar electrolytic grade Aluminium 1000Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing:- (a) MCCB 250 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-02 Nos. (b) MCCB 125 amps, 4 pole,25 KA with adjustable thermal over load release 50 Hz, 415 volts grade 01 Nos. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connection of cables ,connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder changeover pillar box out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) Onload changeover switch 250 amps, 4 pole, 35 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 01 Nos. (b) Bus bar electrolytic grade Aluminium 800Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing:- (a) MCCB 160 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-01 Nos. (b) MCCB 125 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-01 Nos. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connection of cables ,connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder changeover pillar box out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) Onload changeover switch 250 amps, 4 pole, 35 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 01 Nos. (b) MCCB 250 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-1 Nos. (c) Bus bar electrolytic grade Aluminium 400Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing:- (a) MCCB 125 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-01 Nos. (b) MCCB 63 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-02 Nos. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connection of cables ,connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder changeover pillar box out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) MCCB 630 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-1 Nos. (b) Bus bar electrolytic grade Aluminium 1000Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing:- (a) MCCB 400 amps, 4 pole,35/36 KA with adjustable thermal over load release 50 Hz, 415 volts grade-01 Nos. (b) MCCB 125 amps, 4 pole,25 KA with adjustable thermal over load release 50 Hz, 415 volts grade -01 Nos. (c) MCCB 100 amps, 4 pole,25 KA with adjustable thermal over load release 50 Hz, 415 volts grade -01 Nos. (d) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connection of cables ,connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15 mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings MCCBs are to busbar spadles to fitted complete base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- ( a) MCCB160 A 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, with thermal adjustable and fixed magnetic setting with extended terminals -01 No. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 250 Amp,4 pole - 01 set.
Outgoing :- (a) On load Change over 125 amps 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, with thermal adjustable and fixed magnetic setting with extended terminals -01 No. (b) MCCB63 A 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, with thermal adjustable and fixed magnetic setting with extended terminals -02 No. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming LT cable 95 sqmm -02 Nos and out going cables 70 sqmm -01 Nos ,35 sqmm -01 Nos and 25 sqmm - 3 is including rate quated by vendover.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15 mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings MCCBs are to busbar spadles to fitted complete base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming :- ( a) MCCB 100 A 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, with thermal adjustable and fixed magnetic setting with extended terminals -01 No.
Outgoing :- (a) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 200 Amp,4 pole - 01 set. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables. (vi) cable glands for incoming LT cable 70sqmm -01 Nos and out going cables 25 sqmm -02 Nos ,50 sqmm -01 Nos and 35 sqmm - 3 is including rate quated by vendover.
Material and labour for cement M-10,(1:3:6) type C2 in foundation, filling and mass concrete using graded crushed stone aggregate complete all as specified & directed by Engr-in-Charge
Material and labour for plain cement concrete M-15,(1:2:4) type B1 (using 20mm graded aggregate) as in coping and footings for poles etc including necessary form work complete all as specified & directed by Engr-in-Charge.
Supply and erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws. Poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-31, (9 mtr) long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height of 1.5 m and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole complete all as specified and directed by Engr-in-Charge. Note: - Excavation, Earth Work and PCC in foundation shall be measured and paid for separately.
S&F of Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, including pole TOP RING fixing for Flood lights made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-64 (12 m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the and portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each 300 mm wide alternately and marking pole number. with black paint at suitable height complete all as specified and directed by Engr-in-Charge. Note: - Excavation, Earth Work and PCC in foundation shall be measured and paid for separately.
Supply and fix LED street light fitting with dusk 60 Watt , 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge. Note :- Necessary fixing authority including reducers may be included in rate.
Supply and fix LED street light fitting with dusk 70 Watt , 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge. Note :- Necessary fixing authority including reducers may be included in rate.
Supply and fix LED street light fitting with dusk 90 Watt , 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge. Note :- Necessary fixing authority including reducers may be included in rate.
Supply and fix LED Flood light fitting 150 watt , with lens IP66, Energy Saving LED light with PDC , Aluminium body & secondary Optical lens for superior light distrubution , Efficacy > 110 Lm/W. 5700k complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED bollard with robust design and efficient garden lights Whistling Oyster/LB12 of 11 watt capacity, IP65 including taking down old UNSV garden lights complete all as specified and directed by Engr-in-Charge.
Supply and fix LED warm white Post Top light fitting 40watts, IP66, Energy Saving LED light with PDC , Aluminium body & secondary Optical lens for superior light distrubution , Efficacy > 110 Lm/W. 5700k complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement of PVC insulated multi stranded copper conductor PVC cable sheathed 2.5 sqmm 3 core and making connections of street light fittings and bollards lights complete all as specified and directed by Engr-in-Charge.
S&F polycarbonated unbreakable Junction box with fuse provn and suitable connection for three phase incoming cable, single phase out going cable endorsed in thermo plastic enclosure. Shock proof safe IP 65, weather proof, rust proof, dust and water proof internally embedded gasket with provn for cable entry through glade of size 200x160x98mm along with MS Clamps copper bus bar for three phase connection and 02X MCB SP 10 Amp 10 KA complete all as specified directed by Engr-in-Charge.
GI pipe bracket Suitable size of light single swan neck shape suitable to fix on top of tubular pole complete with clamps, nuts, bolts and washers complete all as specified and directed by Engr-in-Charge.
Supply & fixing or laying galvanised steel tubing light grade 50 mm dia (ISI marked) for protection of under ground cable on poles / walls under road crossing etc of following sizes including dismantling & taking down existing pipe complete all as specified and directed by Engr-in-Charge.
M&L for boring / road cutting of existing road/path for laying of GI pipe protection for UG cable including making good distrurbed area/surface complete all as specified and directed by Engr-in-Charge.
S&F in replacement of automatic street light control switch of 8 KW three phase using Infrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitabe rating power contractor (s), one Incoming and three Outgoing MCBs rating of 20-32 Amps & main load circuit wiring (copper) of min 10 sqmm should be enclosed in a pole/wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection class-2. The circuit should be also have provision for manual operation (i.e. sensor by pass option) complete all as specified and directed by Engr-in-Charge.
Supply, Installation, commisioning and testing of horizontal centrifugal multi stage pump set of cap 60 HP (45 KW) with bronze impeller casing CI capable to handle clear water having 1620 LPM at effective head of 90 mtr minimum 80% efficiency coupled to driver rating 60 HP, 1475 RPM squirrel cage induction motor as per manufacturer design with all standard fixing coupled through flexible copling to be connected with suction and delivery side with common base (ISI marked) on delivery side with common base frame of MS variable, suitable for 3 phase 50 Hz, 440 Volt energy efficient variable voltage and variable frequency complete all as specified and directed by Engr-in-Charge.
Supply fabrication and fixing MS joints like bends Tee, tapers, collars, elbow, tail piece (any type) caps, plugs up to 150 mm bore complete all as specified and directed by Engr-in-Charge.
Supply and fix Foot Valve conforming to IS 4038, 150 mm dia complete all as specified and directed by Engr-in-Charge.
M&L for Construction of PCC plateform of M-17(1:2:4), type B-1 over 75 mm thick M-7.5(1:4:8), type D-2 for foundation of pump with motor of capacity 90 HP having the height of 30 cm above GL and 30 cm below ground, consisting at plateform of size 1.8 x1.8x 0.6 m including grouting nuts and bolts of dia 16 mm and 65 cm long suitable for pump set and motor complete including excavation , returning, removal necessary form work & 15 mm thick cement plaster in cm 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for laying tubes medium grade galvanised plain end with all fittings laid in trenches of size 150 mm bore including all fittings such as bends (any type, radius or angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) TEE pieces single branch, 'Y' Junction, double branch, cross collars, cap and plugs, MS flanges complete bends, TEE pieces, collars, elbow, tail piece etc complete all as specified and directed by Engr-in-Charge. Note :- (i) Flanges to be provided at every 6 m length of plain end pipe or shorter length as directed by Engineer-in- Charge. Flange will be welded to the GI pipe and gasket to be provided between two flanges and will be fixed with 08 Nos of nuts and bolts (M16 Type) at each jointing. Flanges will be of IS-6392 specifications. The cost of flanges, nuts & bolts, gaskets and connecting of flanges to pipeline by welding will be deemed to be included in the quoted item rate.
(ii) All standard fittings such as bends (any type, radius or angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) TEE pieces single branch, 'Y' Junction, double branch, cross collars, cap and plugs, MS flanges complete bends, TEE pieces, collars, elbow, tail piece etc jointing are deemed to be included in the quoted item rate. Make of fittings - ISI marked. (iii) Jointing of pipe line will be done through flanging only and as directed by Engr-in-Charge. (iv) Excavation and earthwork will be measured and paid separately. (v) Any special fittings to be fabricated at site as per typical site condition will be measured and paid seprately. (vi) Welding of flanges to be done by trained personnels at site and included in the quoted rate for normal flange joints for nominal length of pipes. However if the welding of pipes (other than normal flanged joint at nominal length) is required the same shall be measured and paid separately. (vii) Execution of work should be carried out without hampering the daily routine water supply.
Supply, Installation, commisioning and testing of 150 LPH , Tech Industrial Reverse Osomosis, Ultra Violet, Ultrafiltration water purifier system as per latest technology consisting of fiber reinforced polymer vessel with treatment media like FBM, AFM, MGS, ACM CPM etc along with back wash system with multiport valves strainer feed water pump, high pressure pump, Reverse Osmosis elements Ultra voilet system with electric control panel and internal UPVC pipe and fittings gate valves, Non Return valves inlet and outlet connection fitted on well furnished and painted MS covered frame complete in all respect with Antiscalant Dosing system and container complete all as specified and directed by Engr-in-Charge.
Supply, Installation, commissioning of water cooler fully stainless steel, electric driven single phase having storage capacity 150 ltrs and nominal cooling capacity 150 ltrs per hour complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with PVC insulated single core cable of stranded copper conductors of size 4 sqmm (Nominal area), 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 4 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, etc all as directed for one 3 pin socket outlet 15 Amps on independent board complete all as specified and directed by Engr-in-Charge.
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed by Engr-in-Charge.
M&L for laying tubes medium grade galvanised with all fittings laid in trenches of size 20 mm bore including all fittings such as elbows, Tee, socket, union, reducers, etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing gun metal gate valve ISI marked cast copper alloy screwed down high pressure with clutch or butterfly handle screwed both ends for iron pipe or for union and fixed for the size 20 mm dia bore complete all as specified and directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank 1000 Ltrs capacity, ISI marked (cylindrical vertical with closed top), double wall layer construction, hoisted and fixed in position complete all as specified in SSR Part-I, making connections incl 20mm bore ball valve brass with polyethylene float and fly nut, complete all as specified and directed by Engr-in-Charge.
100 mm thick cement concrete type C-2, M-10(1:3:6) (using 20mm graded aggregate) as in plinth protection finished fair & even without using extra cement, complete all as specified and directed by Engr-in-Charge.
M&L for framed work Fe-410-W (Gde E-250 quality- A) as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors etc, to be prepared for hanging or sliding with and incl either hooks and hingers or steel hanging door fittings (exclusive of steel sheeting or oyher covering,running rails and guides) and hanging , fastening and fixing complete all as specified and directed by Engr-in-Change.
Rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk)forming holes, with riveted,bolted or welded attachment conforming to grade Fe.290.Gde-E-165, steel work duly painted with one shop coat of zinc chromate primer including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
S&F expanded metal exceeding 4.00 kg per sqm cut to length, bent to shape and welded with MS angle iron frame , complete all as specified and directed by Engr-in-Charge.
M & L for providing earthing with GI earth plate electrode 600 X 600 X 3.15 mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25x4 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR 1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity.
MOHAN LAL AND SONS
V K Sales and Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .