Tender Value
Refer Docs
EMD Value
₹87,660
Closing Date
4 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
ESTABLISHMENT OF BIO SAFETY LAB-3 AT INMAS UNDER GE I RND DELHI
2020_MES_378169_1
GE/RND-52/DLI/2020-2021
Open Tender
Civil Works
Item Rate
180 days
DELHI
Class D, Cat a(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹87,660
Yes
19 Feb 2021
16 Sept 2020
6 Feb 2021
16 Sept 2020
4 Feb 2021
23 Jan 2021
60 days
Amount
Excavating in trenches in hard/ dense soil n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified & directed
All as per item srl No 1.00 above exc 1.5m but n exc 3 m in depth.
M&L for PCC 1:4:8 type D2 (40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified & directed.
M&L for PCC 1:2:4 type B2 (40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified & directed.
M&L for RCC Design mix M-25 as in Foundations, including rafts,footings, foundation beams; roof beam plinth beams; bases for columns, RCC platform etc. basement slabs, under-reamed piles and mass concrete complete all as specified & directed. Note : Reinforcement shall be measured and paid seperately.
M&L for RCC Design mix M-25 as in Columns, pillars, piers, posts and struts complete all as specified & directed. Note : Reinforcement shall be measured and paid seperately.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified & directed.
All as per item srl No 6.00 above but except brick.
M&L for brick work straight or curved on plain exc 6m mean radius in cement mortar 1:4 with sub class 'B' brick complte all as specified and directed.
S&F factory made precast heavy duty drain/mahole covers including MS frame and including reinforcement as per IS 12592:2002 with specified thickness including takingout old unserviceable covers complete all as specified and directed.
M&L for 40 mm thick Damp proof course in cement concrete 1:2:4 type B-0 (using 12.50mm graded stone aggregate) to horizontal or vertical surfaces including necessary formwork with using WPC as per mnufacturer's instruction complete all as specified & directed.
M&L for Rendering 15mm thick on fair faces of brick work or concrete wall surfaces in CM 1:4. finish surface even & smooth without using extra cement complete all as specified and directed
M&L 15mm thick rendering on fair faces of brick work or concrete surface, wall surfaces in cement mortar (1:6) finished even and fair complete all as specified & directed.
M&L for Rendering 5mm thick on fair faces of brick work or concrete surfaces ceiling in CM 1:3. finish surface even & fair complete all as specified and directed.
M&L for Hard core, broken stone/boulders to gauge n exc 63 mm complete all as specified & directed.
M&L for 100mm thick PCC 1:4:8 type D2 (40 mm graded stone aggregate) as in subbase complete all as specified & directed.
M&L for Kota stone slabs, machine cut 18-20mm thick, set and jointed in neat cement slurry and mixed with pigment to match the shade of slab including rubbing and polishing complete, as in floors, laid over and including 20mm thick screed bed in cement mortar 1:6, over 25 mm thick PCC type B-1 1:2:4 (using 20mm graded stone aggregate) complete all as specified and as directed.
M&L for machine cut kota stone slab 18-20mm thick as in skirting, dado, over 10mm thick cement plaster in 1: 4 on wall surfaces for fixing kota stone complete all as specified and as directed.
M&L for RCC Design mix M-25 as in Roof Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified & directed. Note : Reinforcement shall be measured and paid seperately.
M&L for RCC Design mix M-25 as in chajjas complete all as specified & directed. Note : Reinforcement shall be measured and paid seperately.
M&L for RCC Design mix M-25 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed. Note : Reinforcement shall be measured and paid seperately.
M&L for preparation of newly plastered wall surfaces and applying two coats of oil bound diestemper over two coats of white wall care putty (1mm thick each coat) complete all as specified and directed.
M&L for preparation of newly plastered wall surface of brick wall and applying two coats of cement base paint over one coat of primer complete all as specified & directed.
M&L for preparing newly plastered surface and applying three coats white wash on ceiling complete all as specified & directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
All as per item srl No 21.00 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M&L for rendering 15mm thick in CM 1:3 on roof surface mixed with integral water proofing compound @ 3% by weight of cement or as per the manufacturers instruction complete all as specified and directed
Supply only integral water proofing compound complete all as specified & directed.
M&L for applying water proofing treatment as under:- (a) Apply one coat of cold bituminous primer @0.40 ltrs/Sqm on prepared plastered surfaces. (b) Laying APP polymer modified membrane 3mm thick and not less than 3.5 Kg/Sqm with side end laps by torch application method as specified. (c) Applying a coat of solar reflective bituminous aluminium paint @0.20 ltrs/Sqm specified and directed.
M&L for 75mm thick Cement concrete type C- 2, 1:3:6 (40mm graded stone aggregate) as in Plinth Protection/Sub base complete all as specified & directed.
S&F Steel rolling shutter 1.25mm thick, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified & directed.
S&F Ball bearing for rolling shutters complete all as specified & directed.
S&F factory made steel window box type made out of 16 gauge steel section for frames & shutters with openable both glass and gauge shutters including pintle hinges 75mm long 12mm dia, 100mm long handle and tower bolt 150mm long, MS hook & eye 150mm long including one shop coat of primer complete all as specified and directed.
S&F steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified & directed.
M&L for painting with two coats of synthetic enamel paint over a coat of zinc chrome/red oxide primer including preparation of new or previously untreated steel surfaces over 10 cm in width or girth complete all as specified and directed.
Formwork for flat rough concrete surface to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified & directed.
Formwork for flat rough concrete surface to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc. complete all as specified & directed.
Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work vertical or to batter complete all as specified & directed.
Formwork to square, rectangular or polygonal sides of pillars, posts, struts, piers, columns and stanchions for rough finished of concrete flat complete all as specified & directed.
Returning, filling in hard/dense soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed
Removing excavated material to a distance exc 1.5 KM and not exc 5 KM depositing where directed at a level not exc 1.50m above the starting point incl loading and unloading complete all as specified and as directed.
Suppply and hoisting 1000 litrs capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified & directed.
S&F 20 mm outer dia 3 layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4(PN-16) UN stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polpropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified & directed.
Excavating over areas, n exc 1.5 m deep and getting out in any type of soil all as speciified and directed.
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed .
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement complete all as specified and as directed.
M&L for RCC 1:2:4 Type B1 (using 20mm graded stone aggregate) as in cover slab complete all as specified and directed
M&L for TMT bars 6 to 8mm dia bars , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
M&L for machine pressed factory made precast concrete interlocking paver block coloured conforming to IS 15658-2006 with grey cement and pigment, any shape and size, 60mm thickness, M-35 grade complete all as specified and directed.
M&L for Sand filling under floors or in foundations consolidation complete all as specified and directed.
M&L 400 micron thick polythene sheet laid on sand layer complete all as specified and as directed (sand layer measured and paid separately).
M&L for providing pavement quality concrete (PQC), RMC of flexural strength 40 Kg/sqcm in field using not less than 400 Kg of cement per cum thickness of concrete 250mm or less and not less than 150mm layer in bays and compacted with using vacuum dewatering system plant, floating operation with power floater, finishing the top surface of concrete with using power trowel, brooming including necessary formwork to sides and edges of concrete complete all as specified and as directed.
-BLANK-
M&L forming construction joints 30 mm deep and 10 mm wide, filled with sealing compound garde A complete all as specified and as directed.
M&L forming contraction (Dummy) joints 30 mm deep x 10 mm wide, filled with sealing compound garde A complete all as specified and as directed.
M&L forming 12mm thick expansion joints filled with pre-formed bituminious filler and top 30mm primed and sealed with sealing compound grade 'A' complete all as specified and as directed.
Removal of demolished material to a distance not less than 5 KM outside the MoD land as directed by Engineer-in-Charge.
Dismantling Mild Steel works of any description and all as specified.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0
M&L for cement concrete type C0 1:3:6 (12.5mm graded stone aggregate) as in plinth courses, copings, parapets, saucers drain, kneelers, apex stones, bed plates, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for 20mm thick Granite stone (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including 10mm thick rendering in CM 1:4 with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding polishing complete all as specified and directed.
S&F factory fabricated and assembled, single leaf motorized gate 10MX2.5M embedded in PCC as shown in drg ,consisting of Guide channel, bottom guide rail, wheel of EN -9 material of 200mm dia 50 mm thick with sealed double ball bearings , wheel tracks other sliding gate fittings with Gate drive system, automatic programming of speed & time of opening and closing of gate set at a speed 300mm/Sec, safety features like automatic obstacle detection system by installing photocells for detection of obstacles/vehicles. Flashing light as open & close indicator with audio alarm, Emergency stop button & safety sensitive edges including cleaning of steel surfaces with metal cleaner solution and applying two coats of epoxy paint over a coat of epoxy primer complete all as specified and shown in drawing and as directed. Note : (i) Design & drawing shall be submit by contractor before installation of motorized Gate and prior approval of Engr-in-Charge/GE(I) is necessary. (ii) Payment shall be made after submission of minimum two year guarantee from contractor. (iii) Bottom guide rail shall be of suitable length for clear opening of 10 Mtr wide gate. (iv) Rate includes for bottom guide rail and PCC for bottom rail.
M&L Point wiring with multistranded copper conductor PVC Insulated and unsheathed cable in PVC conduit dia concealed type 1.5 Sqmm with all fittings /accessories and including 1.5 Sqmm PVC insulated FRLSH copper earth wire connected common earth with terminal boxes for Modular fittings including acessories for one light/Fan/Exhaust Fan point complete.
All as per item srl No 64.00 above but for 05 Amps Socket Independent with terminal boxes, Moduler fittings including acessories complete all as specified and as dierected.
All same as per item srl No 64.00 above but using cable size 2.5 Sqmm with 2.5 sqmm earth wire for one three pin switch socket outlet 15 Amps point with terminal boxes, Modular fittings including acessories complete all as specified and as directed.
All same as per item srl No 64.00 above but using cable size 4.00 Sqmm with 4.00 sqmm earth wire for one three pin switch socket outlet 15 Amps point with terminal boxes, Modular fittings including acessories complete all as specified and as directed.
S&F sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified & directed.
S&F Modular switch 1 way 6A, 1 Module complete all as specified & directed.
S&F Modular switch 1 way 16A, 1 Module complete all as specified & directed.
S&F Modular socket 6A 2/3 pin combined 2 module complete all as specified & directed.
S&F Modular socket 6A/16A- 2/3 pin combained 2 module complete all as specified & directed.
S&F in repair of LED 20 Watt fitting batten with decorative end cap complete with aluminium housing & integral electronic driver with tube 20 watt complete incl connection with 1.5 Sqmm 2 core flexible copper cable complete all as specified & directed.
S&F sheet metal enclosure for DBs 04 Way with acrylic double door having 200 Amps rated copper bus bar 240 Volts AC complete all as specified & directed.
S&F MCB single pole & Neutral 40 Amps complete all as specified & directed.
S&F MCB single pole 6-20 Amps 240 Volts complete all as specified & directed.
S&F LT Panel approx size 1500mm x 1500mm x 500mm out door type cubical panel board suitable for 3 phase, 4 wired, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3.15mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT Panel shall be front and back openable type and having inner and outer shells. The inner shells duly compartmentalized for each control gears. The panel shall be have suitable size of Aluminium bus-bar three phase 4 wired system having current carrying capacity 600 Amps. The panel shall be have the following incoming and outgoing controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engr-in-Charge. (PCC platform of suitable size for mounting the feeder pillar box is deemed to be included in the quoted rate) and to accommodate the following incoming and outgoing controls:- INCOMING (i) MCCB 400Amps 4 pole 35 KA -1 No. (ii) Digital Multi functional meter VAFPP (voltage, current, frequency, power factor-1 No. (iii) Phase indicator lamp (LED type) 1 set (set of three). OUTGOING (i) Change Over Switch ON LOAD Type 315 Amps 4 Pole-01 No. (ii) MCCB 320 A 4 pole 35KA- 01 No. (iii) MCCB 125 A 4 pole 35 KA - 01 No. (iv) MCCB 63 A 4 pole 25 KA - 01 No. Note 1. Before fabrication of panel the contractor shall submit detailed general arrangement drawing and single line diagram of all panel for approval. A drawing shall also show foundation details, list of components in the manufacturer's refernce and bill of materials. 2. Panel should be manufactured by CPRI approved and manufacuturer's CPRI test certificate to be produced.
S&F MCCB 4 Pole 400 Amps 50 Hz, 415Volts with repturing capacity 35 KA complete in existing LT Panel complete all as specified & directed.
Supply, laying, connecting and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 Core complete all as specified and directed.
Supply, laying, connecting and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core complete all as specified and directed.
Supply, laying, connecting and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 Core complete all as specified and directed.
S&F steel tubular swaged poles type 410SP-31 (9.0 Meter long ) Swan Neck type complete with CI base plate and finial and single swan neck, including foundation and coping Note : Earth work and concrete work shall be measured & paid seperately.
Supply and fix LED Street Light fittings 90 Watt with pressure die cast housing with toughned glass and industrial LEDs IP-66 Protection complete all as specified and directed.
Supply and fix post LED top lantern light fitting for 40 Watt made of cast aluminium with decorative opal polycarbonate diffuser having IP 65 Protection complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) all as shown in electrical plate No. 03 of SSR Part-I with following:- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip complete all as specified and directed.
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and laying GI pipe light grade in replacement of 50mm dia including fittings laid in trenches or under road crossing for protection of UG cable complete all as specified and directed.
Supply and laying GI pipe light grade in replacement of 80mm dia including fittings laid in trenches or under road crossing for protection of UG cable complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless techonology using ultra sound technique/mannually/mechanically and necessary machine including supply and laying of 100mm dia GI pipe light grade including making necessary excavation upto 1.5 mtr deep on both side of road for making holes and inserting 100mm dia GI Pipe complete all as specified and directed by Enginer-in-Charge
M&L for fabrication of GI Bracket made of 40mm dia GI light grade pipe bend to shape approx 1.00 mtr long including 02 Nos flat iron Clamps, nuts bolts washers etc complete all as specified and directed.
S&F copper cable 2.5 Sqmm 3 core sheathered for connection of street light from junction box inserting inside pole and connection complete all as specified and directed.
S&F Junction box SMC KIOS box water proof of size 140x140x95 mm incl fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specified and directed.
M&L for PCC (1:2:4) type B2 using 20 mm graded stone aggregate for coping of pole around pole all as specified and as directed by Engineer-in-Charge.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with GI wire 4.00mm by means of nuts, bolts and washers. GI Wire laid in 15mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) as shown in electrical plat No. 03 of SSR Part-I with following:- (a) GI wire 4.00mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
ASHISH GARG AND COMPANY
JM enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .