Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹43.1 LAdmitted-Finance | -29.89% | ₹43.1 L | L1 | Admitted-Finance |
| 2 | L2₹46.5 LAdmitted-Finance | -24.24% | ₹46.5 L | L2 | Admitted-Finance |
| 3 | L3₹48.8 LAdmitted-Finance | -20.50% | ₹48.8 L | L3 | Admitted-Finance |
| 4 | L4₹49.1 LAdmitted-Finance | -20.11% | ₹49.1 L | L4 | Admitted-Finance |
| 5 | L5₹49.7 LAdmitted-Finance | -18.99% | ₹49.7 L | L5 | Admitted-Finance |
Tender Value
₹61.4 L
EMD Value
₹1.2 L
Closing Date
25 May 2026, 3:00 pmClosed
Executive Engineer, Civil Division-X
Executive Engineer, Civil Division-X
Renovation of Park near jamia metro station, 9 no Thokar Park and Repair Senior citizen center in Shaheen bagh in Okhla Constituency AC-54.
2026_IFC_291593_1
EE/CD-X/2026-27/14
Open Tender
Civil Works
Works
90 days
Okhla
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1.2 L
25 May 2026
19 May 2026
25 May 2026
19 May 2026
25 May 2026
19 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing & fixing Wall Panelling ( using 1.5" x 1" section aluminium pipe covered with 12mm BWP marine ply using decorative veneer and pine moldings, Polishing matt finish clear & Electrical (wiring, switches,panel lights,Cove light,Decorative wall lights, fans, exhaust and other necessary fixtures) etc complete as directed by Engineer in charge. | 89 | Sqm | 11,192 | ₹9,96,088 |
| 2 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600 mm to formgrid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with precut hole on both 25 mm flange to pierce into 12x50 mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge.With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles | 83 | Sqm | 2,211.83 | ₹1,83,581.89 |
| 3 | Supply and install hi wall split unitsindoor/outdoor complete with cordless remote control unit and with in built airioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2& above. Compressor type, rotary, refrigerant including copper pipes with insulation, copper armoured cables for connection of indoor and out door unit upto 6 mtrs length and PVC drain pipe of size 15mm upto 6 mtrs complete all as specified and as directed. Make :- Voltas/ Hitachi / Daikin/ Blue star , Carrior Note :- Copper pipe with insulation upto 6 mtr including cable for connections and drain pipe upto 10 mtr are inclusive of rate quoted. | 8 | nos | 60,815.37 | ₹4,86,522.96 |
| 4 | S&F Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for window type air conditioners. Make : Siemens Cat-8GB0501RC or equivalent in GE/ Legrand. | 6 | nos | 1,817.8 | ₹10,906.8 |
| 5 | Providing and fixing wooden alimrah | 15 | Sqm | 16,065 | ₹2,40,975 |
| 6 | providing & placing computer approved company as approved by Engineer in charge | 6 | nos | 90,000 | ₹5,40,000 |
| 7 | Providing & Placing colour plinter with scanner as approved By Engineer in Charge | 6 | nos | 40,000 | ₹2,40,000 |
| 8 | Dismantling dumping and water proofing for tikona park & const for the same & Mozek Tile and granite as approved by Engineer in Charge | 64 | Sqm | 6,104.7 | ₹3,90,700.8 |
| 9 | Providing & fixingFlex Backlit flex and led module with MS frame as directed by Engineer in charge | 300 | Sqm | 6,104.7 | ₹18,31,410 |
| 10 | Structure with waterproof coating, Fountain lightingd and decorative lights Barb wire with MS frame Etc Complete as directed by engineer in charge. | 2 | job | 5,63,000 | ₹11,26,000 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.93 MB
NIT.pdf
Tender Documents • 0.91 MB
BOQ_386979.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].