Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC | L1 | Accepted-AOC L-1 | |
| 2 | L2₹20.5 L+₹2.0 L (10.9%)Rejected-AOC | L2 | Rejected-AOC L-2 | |
| 3 | L3₹20.7 L+₹2.2 L (11.7%)Rejected-AOC H NO 177 GOVINDPURA SATWARI JAMMU CANTT 180003 J K | JAMMU | JAMMU AND KASHMIR | 180003 | L3 | Rejected-AOC L-3 | |
| 4 | L4₹21.0 L+₹2.5 L (13.7%)Rejected-AOC | L4 | Rejected-AOC L-4 | |
| 5 | L5₹21.1 L+₹2.6 L (14.3%)Rejected-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIR PORT ROAD JAMMU INDEX NO D 04 ADGNJ | JAMMU | JAMMU AND KASHMIR | 180001 | L5 | Rejected-AOC L-5 |
Tender Value
Refer Docs
EMD Value
₹41,000
Closing Date
10 Mar 2021, 6:00 pmClosed
CWE Jammu
HQ CWE Jammu Pin 900172 C/o 56 APO
SPECIAL REPAIR TO BLDG NO T-45 IN S K LINES AT MIRAN SAHIB UNDER GE JAMMU
2021_MES_417092_1
CWE/JP-78/2020-21
Open Tender
Support/Maintenance Service
Item Rate
180 days
AOR G E Jammu
Class E, Cat a(i)
9 documents required · 9 mandatory
₹500
G E Jammu
₹41,000
Yes
26 Apr 2021
29 Jan 2021
17 Mar 2021
29 Jan 2021
10 Mar 2021
24 Feb 2021
Amount
B&R PORTION:- Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed.
Brickwork in CM 1:4 with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, complete all as specified and directed
All as per Srl item No.2 above but except brick, complete all as specified and directed.
RCC type B1 1:2:4 (using 20 mm graded stone aggregate ) as in lintal band etc, complete all as specified and directed
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed
TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns and binding with and including mild steel wire anneled not less than 0.9 mm dia conformung TMT bar complete all as specified and directed.
All as per item 6 above but 6 mm to 8 mm dia complete all as specified and directed
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
Rendring 15mm thick in cement mortar 1:4 with water proofing compound on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. Note :- Water proofing compound shall be measured and paid separately under respective item.
Rendring 15mm thick in cement mortar 1:6 on other than fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Prepartion of surfaces and applying two coats of oil bound distemper complete all as specitied and directed.
Preparing new plastered wall surfaces and applying two coats of cement paint over a coat of primer complete all as specitied and directed.
Taking down Chowkats or frames n.exc 1.5 sq.m each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames exc 1.5 sq.m but n.exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Solid PVC door frame of size 50mm x47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification & drawing all as specfied and directed.
Factory made solid panel PVC moulded door shutter with particle board core 28 to 30 mm thick (stiles) with 2,4 or 6 raised panel design with 2 mm thick moulded prelaminated PVC sheet on front face and 2 mm thick plain color PVC sheet on back face supply and fixing in frame at site as per specification and drawing complete all as specified and directed.
35mm thick factory made wooden panel door framed, panelled shutter with masonite facing boyh side of(two three or four paneldesign as approved) made of solid core using machine field rigid expanded polyurethane foam the the door facing plate shall be 3.2 mm thick complet all as specufied and directed
35 mm thick 2nd class hard wood factory made glazed & skeleton shutters, open rebated & prepared to receive glass gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, section 8, clause 8.20 (a); complete all as specified and directed.
Box type steel windows / ventilator(factory made) outer frame made out ERW tube 'P' section 65X45X25 mm and shutter of ERW tube 'P' section 50mmX35mmX20mm openable (double shutter) with glazed shutter on extrernal side and gauzed shutter on internal side including steel pintel hinges steel handle 100 mm long mild steel tower bolt 02 Nos on each shutter stopper of 'Z' section and its locking arrangement and mild steel hook and eyes complete all as specified and shown on drgs Nos CEPZTD-324/07 Sh 1/3 to 3/3. Note:- The quoted rate by the contractor shall also include the following:- (i). One shop coat of zinc chromate primer on all exposed surface and one coat of tar on the ends of steel surface in contact with bricks / concrte surface (ii) 4 Nos MS steel lugs made of 20X5 mm Iron flat 200 mm long (iii) PCC block for embedding lugs (iv) Cooler windows where required (v).10 mm square bar as in guard bars
Mild steel framed works such as grills, framed guard bars, cooler stand etc etc and similar work conforming to Fe 410-0 or Fe 310-0 Including necsssry welding, cutting holes and embedded in PCC1:2:4 as necessary complete all as specified and directed.
Pressed steel frames (factory made) made out of 1.25 mm thick black MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete size of frame 105x60mm incl bottom of each chowkat to be welded with 2 Nos 25x25x3mm thick flat iron projecting 10 cm on either side complete all as specified and directed.
All same as per item No 21 above but size of frame 125x60mm complete all as specified and directed.
PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in back filling, bed block for hold fast, coping, benching on corner of joints etc complete all as specified and directed.
100 mm size but hinges medium weight cold rolled stainless steel complete all as specified and directed.
Aluminium handles "D' type anodised 150 mm long ISI marked complete all as specified and directed.
Aluminium handles "D' type anodised 125 mm long complete all as specified and directed.
150 mm long aluminium anodised barrel tower bolt of extruded section ISI marked complete all as specified and directed.
125 mm long aluminium anodised barrel tower bolt of extruted section ISI marked complete all as specified and directed.
250 mm long 16mm dia aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded section & fixing blots & sliding bolts of extruded section complete all as specified.
2nd class hard wood small fittings such as brackets of any type, shaped door and windows stops and the like article not exe 200 cucm each and fixed all as specified and directed.
150mm size mild steel ordinary rat tail rod pattern springs including roller & roller plate complete all as specified and directed.
Galvanised mild steel wire cloth 0.46 mm nominal dia or wire and average width of aperture 1.0 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed.
3mm thick sheet glass, ordinary quality glazing with oil putty & pin in suare n.exc 0.5 sqm in each pane complete all as specified and directed.
Dismantling wall and ceiling boards (fibre pulp/insulation ) or insuletion board /slab/blankets any thickness including cover fillets&frame work complet all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section, in any position as in unframed work complete all as specified and directed.
Dismantling mild steel work as in wind tie grill grating etc complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated ete.) sheets in roof covering complete all as specified and directed.
PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in bed blocks for fixing bolt & MS tubuler pipe etc complete all as specified and directed
Mild steel bolts.purpose made.with hexagonal orsquare head one end and screwedthe other, or screwed both ends;each screwed end to be fitted with washers and one hexagonal orsquare nut. exc 30cm long (dia of necxk exe 12 but n exe 20 mm) complete all as specified and directed.
Structural steel works as in roof trusses, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats plate etc confirming to gde Fe 410-W (GDE E-250) quality-A complete all as specified and directed
Plates (plain or chequered)channels, square cut or notched (ordinary and counter sunk)forming holes, without anyattachment as in gusset plate, base plate etc gde Fe 410-W (GDE E-250) quality-A complete all as specified and directed
Steel work in tubular trusses as in post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
Preparing surfaces of new wood and wood based materials of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint over a coat of pink primer compete all as specified and directed
All same as per Item No 43 above but on new steel surface over a coat of red oxide primer complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws or L type or J- type or cranked hook bolt complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge of roof fixed with self tapping screws or L-type or Jtype or cranked hook body complete all as specified and directed.
600x600 mm grid frame of galvanised iron powder coated section incl supply and fixing 4 mm thick non asbestos designer E board and comprising of under mentioned section etc for grid frame :- (a) Suspended GI main runner 32x24 mm bulb Tee section fixed with 4mm dia GI bar @ 1200 c/c level shall be adjusted with fly/bionet screws. (b) Placed in position cross Tee 600 mm long and 24x26 mm bulb Tee section @ 605 mm c/c using shape and bionet fixing arrangement to secure main runners. (c) Ceiling GI 26x24 mm size bulb section installed 605 mm long in between cross Tee. (d) GI coated angle 24x24 mm fixed with PVC rawl plugs and GI screws to secure with walls. (e) All the fixing details as shown on drg No CEPZ/STD/809/07 dt 03-11-2007 and as per manufacturer instructions and as approved by GE
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness below or above ground level all as specified.
25 mm thick PCC 1:2:4 type B -0 (using 12.5mm graded stone aggregate) ,as in floor surface complete all as specified and direction.
75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base to recive top layer complete all as specfied
Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:4. complete all as specified and directed.
Machine cut kota stone slab not less than 19 mm thick as floor to match the shade of the slab including rubbing for mirror polishing upto mirror finish complete all as specified and directed
Machine cut kota stone slab flooring not less than 19 mm thick as in riser in step, skirting/ dado to match the shade of the slab incl rubbing and polishing upto mirror finish laid over and incl 10 mm thick rendering in CM 1:3 to receive to kota stone complete all as specified and directed.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade laid over and including 50mm thick sand cushioning, complete all as specified and directed
75 mm thick cement concrete (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection etc and laid in alternate bays complete and finished even and smooth without using extra cement including making 10mm wide grooves to full depth at 3 metre interval and at every change of direction and filled with mastic filling comprising one part of 01 bitumen 85/25 grade and three part of sand by weight and top 10 mm depth shall be sealed with sealing compound grade A, complete all as specified and directed
Dismanting floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed.
Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:4 complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick, edgeless, area of each tile exc 0.11 sqm but n exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match to match shade, pattern, laying etc of tiles complete all as specified and directed.
Glazed ceramic colour tiles 350 x450x 7 mm thick dado, skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10 mm thick rendering in CM1:3 to receive tile complet all as specified and directed
PCC 1:2:4 type (B-1 using 20 mm graded stone aggregate) in surface channel and drains including necessary form work etc complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement conc including moulds, mitred/stopped end etc.complete all as specified and directed..
Taking up or down 15 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
15 mm bore steel tubing, medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
20 mm bore steel tubing, medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Refixing old 15 mm bore steel tubing and connections in new or old position (wall, ceiling, floor etc) complete all as specified and directed.
Refixing old 20 mm bore steel tubing and connections in new or old position (wall, ceiling, floor etc) complete all as specified and directed.
Dismantling water tanks exe 500 & n exe 1000 ltr complete all as specified and directed.
1000 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) three layers hoisted and fixed in position complete all as specified and directed.
Vitreous china squatting pan 'Orissa pattern, size 580x440 mm white, with integral foot rest and P or S trap and connection to flushing pipe, anti-syphonage pipe complete including provision of cement concrete bedding fixed in repair complete all specified in SSR part I complete all as specified and directed.
Wash basins, Vitreous China flat back or angle size 550X400 but including bracktes 32 mm brass/CP waste coupling cutting waste pipe for and planing in ends of bracktes or erecting stand fixed in repair complete all as specified and directed
Vitreous China half stall urinal flat back size ,with grating complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs pointing around urinal back in cement; ,flush pipe, grating and Union for discharge pipe. (excluding of supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
PVC valve less syphon action type low level flushing cistern 10 liters capacity with inlet, ball valve, float valve, push button type handle including telescopic flush pipe 32mm dia of stain less steel with long bend of 32mm dia fixed in repair complete and all as specified
15mm dia PVC connection with PTMT nut of length 450mm fixed in repair complete all as specified.
32 mm bore low dencity PVC flexible pipe of 80 cm long for wash hand basin / urinal complete all as specified.
Bib taps suitable for 15mm bore pipe long neck fancy type cast copper alloy CP with, Capstan head screwed down screwed for iron pipe or brass ferrule fixed in repair complete all as specified and directed.
Cast copper alloy CP angle valve type stop cock suitable for 15mm bore pipe screwed at both ends or high pressure with Capstan head fixed in repair complete all as specified
15mm bore brass stop cock cast copper alloy CP with long shank and cup (concealed type ) high pressure with capstan head handle with not less 450 gms screwed both ends for iron or for union fixed in repair complete all as specified and directed
15 mm dia CP Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in repair complete all as specified and directed
15 mm dia Gun-metal, globe or gate valves,with iron wheel head, screwedboth ends for iron pipe fixed in repair complete all as specified and directed.
20 mm dia Gun-metal, globe or gate valves,with iron wheel head, screwedboth ends for iron pipe fixed in repair complete all as specified and directed.
Shower rose brass chromium plated with swivel joint of size 125 mm cast vcopper alloy CP fancy type CP neck 9" long made to shape weight not less than 350 gms fixed in repair complete all as specified and directed
Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead of 100/75 mm dia pipe complet all as specified and directed
Cast iron soil, waste and vent pipe of bore 100mm sand cast in any length with or without ears with cement joints fixed to wall complete all as specified and directed.
Cast iron soil, waste and vent pipe of bore 75 mm sand cast in any length with or without ears with cement joints fixed to wall complete all as specified and directed.
Cast iron bends (any redius) diminishing pieces or tapes of size 100mm with inspection eye.
Cast iron bends (any redius) diminishing pieces or tapes of size 75 mm with inspection eye complete all as specified and directed.
Cast iron floor trap with 75mm dia out let with stainless steel grating including jointing to waste pipe in run lead complete all as specified and directed.
20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed ( min. wt 210 gm ) , fixed in repair complete all as specified and directed
Brass CP towel rail 20 mm dia 'D' type 60 cm long between flanges complete all as specified and directed.
MS peg set of six powder coated as approved by GE complete all as specified and directed.
Drapery curtain rod of metalic 20 mm dia covered with PVC coating including MS bracket, end ball, rounded block (coated with brown/cherry/golden colour) of approved pattern and shade fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screw complete all as specified and directed.
Supply only Water proofing compound of approved make complete all as specified and directed.
Taking down roof truss coupled rafters or trussed beams above 4 m & upto 8 m complete all as specified and directed.
E&M PORTION:- Taking down carefully unsv aluminium / copper conductor point wiring (light, fan, light socket, power socket) complete fitting such as swithes, sockets, lamp holder, utility light fitting, fan regulator etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed.
Taking down carefully unsv main switch / DBs alongwith MCBs / wooden board / connected fittings & fixtures any type and making good distrubed surface of walls and roofs to match the existing surface, complete all as specified and as directed.
Taking down carefully unsv unserviceable sub main wiring of any size of two core with and including earth wire, batten/conduit and making good distrubed surface of walls and roofs to match the existing surface, complete all as specified and as directed.
Point wiring with 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated and unsheathed heavy duty cable drawn in existing concealed PVC rigid conduit medium grade ISI marked terminated into existing CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc for one light/fan/Exhaust fan point controlled by one switch/ 2way bell push or one fan point controlled by one switch through regulator, complete all as specified.
Description all as per item No. 99 above but for 3 Pin socket outlet 5 Amps point on same board with PVC insulated copper conductor cable 1.5sqmm complete all as specified and directed.
Description all as per item No. 99 above but for 3 Pin socket outlet 5 Amps point on independent board with PVC insulated copper conductor cable 1.5sqmm complete all as specified and directed.
Description all as per item No. 99 here in before but for 3 Pin socket outlet 15 Amps point on independent board other switches with with PVC insulated copper conductor cable 2.5sqmm 1100 Volts grade in and including concealed PVC rigid conduit 20mm bore, medium grade ISI marked terminated, complete all as specified and directed.
Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified.
Socket outlet multipurpose combination 2 in 1, 5 Amp flush type universal, complete all as specifed.
Switch socket multipurpose combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal,complete all as specifed.
Fan regulator stepped type (electronic ) flush type for 1200/1400mm sweep AC ceiling fan, complete all as specified. .
Ceiling rose (ISI Marked) 3 Phase PVC/poly carbonate, insulated body, compete all as specified.
Sub main wiring with single core cable 2x 6 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed) medium grade alongwith 1x4 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including chasing, cutting & making good to match with the existing surface complete all as specified and directed. Note:-2 wire of 6sqmm, 6sqmm and one run of pvc conduit shall be measured as one unit.
Tube light fitting box type suitable for LED 20W tube Rod with end cap made out of CRCA sheet powder coated complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including 18-20LED tube rod 4 feet long complete all as specified and directed. Make:-Crompton Cat Part No:-LTT8-20 for LED tube rod & DMLN1LT8-16 for fittings or Equivalent cat part of make as specified in Appx 'F' here in after. Note :- The LED batten and LED tube rod shall be of same make.
Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Self ballast LED retrofit lamp 9W, 230 volt 6500K, complete all as specified and directed.
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, complete all as specified. Make:- Legrand cat part No-5076 21 or Equivalent cat part of make as specified in Appx 'F' here in after.
MCB single pole and neutral 32 amps 240 volts 10 KA 'C' series all as specified. Make:- Legrand Cat Part No 4086 17 or Equivalent cat part of make as specified in Appx 'F' here in after.
MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series all as specified. Make:- Legrand cat part No-4085 87 to 4085 95 or Equivalent cat part of make as specified in Appx 'F' here in after.
Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube flor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion.
Taking Down ceiling fan from existing position and refixing of existing Fan complete after repair/maint including replacement of unserviceable spare parts ie bearing, bush, PVC clamp, canopy, capacitor including painting two coats of synthetic enamel paint, rewinding of fan of any make / type and size (1200mm/1400mm) with super enameled copper wire of appropriate gauge as existing gauge to optain the specified and satisfactory RPM as per manufacturers specifications, with and including all insulation materials, varnishing, heating, drying, assembling of stator / rotar, connection and testing complete all as specified and directed.
Taking Down exhaust fan from existing position and refixing of existing Fan complete after repair/maint including replacement of unserviceable spare parts ie bearing, bush, PVC clamp, canopy, capacitor including painting two coats of synthetic enamel paint, rewinding of fan of any make / type and size with super enameled copper wire of appropriate gauge as existing gauge to optain the specified and satisfactory RPM as per manufacturers specifications, with and including all insulation materials, varnishing, heating, drying, assembling of stator / rotar, connection and testing complete all as specified and directed.
1100 volts grade heavy duty electric cable with PVC insulated screened PVC bedded aluminium stranded conductor of size 10 Sqmm x 2 core, served with inner sheathing of PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, complete all as specified.
40mm bore GI pipe medium grade bracket of 3 metre made to shape as required fixed on wall or pole with FI clamp of required shape & size, not, nolts, washers, two Nos 90 degree bends MS hook and stay or guy complete all as specified and directed.
N S MANHAS
M/S A TO Z ENGINEERS
M/S RAVINDER SINGH
GENESIS INDIA
M/s Anand Prakash
M/S MOHAN LAL GUPTA
M/S Shesh Paul Gupta
SHIVAE CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .