| 1.00 | Design, Engineering, supply, fabrication, erection, testing, commissioning and handing over of 1No 26 persons capacity Gearless Bed Cum passenger lift with Machine room as per the following Technical specifications inclusive of all taxes and duties.
Technical specifications.
1. Location : Hospital Block 2, in G.H at Tirukoilur.
2. No of Lift : 1 No
3. Type of lift : Bed cum passenger lift. (1768 Kgs)
4. Capacity of lift : 26 persons capacity Gearless passenger lift.
5. Speed : 1.0 M / Sec
6. Type of Drive: Specific variable voltage variable frequency V3F drive with enhanced ride comfort and near Zero leveling functions.
7. No. of floors: 7 (Ground + 6 floors)
8. Total Travel: 19.8 mtrs Travel.
9. Levelling Accuracy: High level accuracy with smooth and jerk free stopping.
10. Construction of Car: 18SWG High quality S.S 304 Grade car, Neat hair line finish, S.S. hand rail, S.S floor line finish, Perspex false ceiling, stretcher impact protection.
11. Position of machine: Directly above the lift well.
12. No. of landing entrance: one in front 7 Nos.
13. No. of car entrance: one in front only.
14. Car entrance door: power operated V3F drive side opening sliding 18SWG stainless steel hair line finish.
15. Landing entrance door: power operated V3F sliding, opening 18SWG stainless steel hair line finish with provision for emergency key.
16. Lift well existing: 3000mm x 2400mm. | 1 | No | 41,47,500 ₹41.5 L | 40,68,500 ₹40.7 L |
| 1.0117. Lift pit depth 1600mm 18. Car size (Clear insde) : 1600mm (wide) x 2400mm (Depth). 19. Car clear opening: 1200mm width x 2000mm height 20. Lift machine room available: 4350mm width x 5500mm height 21. Power supply: 400/440 V, 3 phase, 50 Cycles/sec A.C. supply for power and 230 V, 50 HZ, single phase, supply for lighting. 22. Control: Micro processor based simplex selective collective simplex. 23. Car fittings: sleek LED light fitting with 300mm sweep cabin fan. 24. Lift well: R.C.C. construction with brick masonry. 25. Indication: UP/Down digital direction and position indicator for all landing and in car (25mm Height, seven segment Digital Floor position indicator scrolling type) 26. Emergency Alarm Bell: Battery operated alarm bell to be provided with Automatic charging device. 27. Emergency light: Battery operated light to be provided with Automatic charging device. 28. FireMan’s switch: To be provided at ground floor 29. Minor builders work: To be provided by lift contractor. 30. Scaffolding: To be provided by lift contractor. 31. Sill angles and facia plates: To be provided by lift contractor. 32. Steel for lift machinery: To be provided by lift contractor. | |||||
| 1.0233. Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 34. Automatic Rescue device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. 35. Provision of intercom with phone: To be provided by lift contractor 3 points EPABX system at three places vide 1) inside the car 2) Head room 3) at ground floor attender room. 36. Lift License: Preparation of Drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. 37. Floor announciator with music included. 38. Special features: a. Infra red door sensor with full height screen. b. Tubular S.S hand rail in cars. c. Voltage stabilizer for circuit control. d. Stainless Steel signal fixtures. e. Vendal proof S.S. Button with S.S. cover f. SS hair line finish door frames for landing doors. g. VF door Register signal. h. Call Register signal i. Stainless steel facia plate for car operating panel and landing fixtures. j. Steel ladder for machine room and ladder for lift shaft pit. k. On – Off switch for fan and light l. Over load warning indicator with audio announcement. m. Fall width of half height rear panel mirror. | |||||
| 1.0339. Provision of architraves covering all three sides up to a width of 300 decorum sheet of plywood with TW frame with aluminum beading architraves should also cover the thickness of sill level door frame at the landing and indicator boxes at all landings. 40. Other standard features: Voltage stabilizer for control units, Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, single reduction worm gear, electromagnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limits switch, main suspension ropes counter weights lifting hoist for mounting the machineries. 41. Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period not less than one year. 42. Site testing in accordance with IS 14665 should be carried out at the time of handing over. Necessary spares and tools required for the maintenance for a period of one year 43. Supply of operation and maintenance manual with Necessary tools for Operation. The list of tools required should be detailed by the contractor in a separate sheet duly signed by contactor. 44. Provision of mirror in the lift car 45. All the features for differently abled persons should be included as per the act. (Johnson/KONE/ OTIS / Eq.) | |||||
| 2.00 | GST @ 18% | 1 | No | 7,46,550 ₹7.5 L | 7,32,330 ₹7.3 L |
Tender Value
₹46.6 L
EMD Value
₹33,500
Closing Date
8 Aug 2025, 3:00 pmClosed
The Superintending Engineer
The Superintending Engineer, PWD., Buildings Construction and Maintenance Circle,Tiruvannamalai-4.
Providing of Additional 1 No 26 Persons bed cum Passengers Lift to the District Head Quarters Hospital Building in the Government Hospital at Tirukoilur in Kallakurichi District
2025_PWD_584751_1
22/TVM-CLE/25-26/3/ Dt.08.07.2025
Open Tender
Electrical Works
Tirukoilur
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹33,500
18 Feb 2026
23 Jul 2025
8 Aug 2025
23 Jul 2025
8 Aug 2025
23 Jul 2025
Amount
Design, Engineering, supply, fabrication, erection, testing, commissioning and handing over of 1No 26 persons capacity Gearless Bed Cum passenger lift with Machine room as per the following Technical specifications inclusive of all taxes and duties. Technical specifications. 1. Location : Hospital Block 2, in G.H at Tirukoilur. 2. No of Lift : 1 No 3. Type of lift : Bed cum passenger lift. (1768 Kgs) 4. Capacity of lift : 26 persons capacity Gearless passenger lift. 5. Speed : 1.0 M / Sec 6. Type of Drive: Specific variable voltage variable frequency V3F drive with enhanced ride comfort and near Zero leveling functions. 7. No. of floors: 7 (Ground + 6 floors) 8. Total Travel: 19.8 mtrs Travel. 9. Levelling Accuracy: High level accuracy with smooth and jerk free stopping. 10. Construction of Car: 18SWG High quality S.S 304 Grade car, Neat hair line finish, S.S. hand rail, S.S floor line finish, Perspex false ceiling, stretcher impact protection. 11. Position of machine: Directly above the lift well. 12. No. of landing entrance: one in front 7 Nos. 13. No. of car entrance: one in front only. 14. Car entrance door: power operated V3F drive side opening sliding 18SWG stainless steel hair line finish. 15. Landing entrance door: power operated V3F sliding, opening 18SWG stainless steel hair line finish with provision for emergency key. 16. Lift well existing: 3000mm x 2400mm.
33. Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 34. Automatic Rescue device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. 35. Provision of intercom with phone: To be provided by lift contractor 3 points EPABX system at three places vide 1) inside the car 2) Head room 3) at ground floor attender room. 36. Lift License: Preparation of Drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. 37. Floor announciator with music included. 38. Special features: a. Infra red door sensor with full height screen. b. Tubular S.S hand rail in cars. c. Voltage stabilizer for circuit control. d. Stainless Steel signal fixtures. e. Vendal proof S.S. Button with S.S. cover f. SS hair line finish door frames for landing doors. g. VF door Register signal. h. Call Register signal i. Stainless steel facia plate for car operating panel and landing fixtures. j. Steel ladder for machine room and ladder for lift shaft pit. k. On – Off switch for fan and light l. Over load warning indicator with audio announcement. m. Fall width of half height rear panel mirror.
39. Provision of architraves covering all three sides up to a width of 300 decorum sheet of plywood with TW frame with aluminum beading architraves should also cover the thickness of sill level door frame at the landing and indicator boxes at all landings. 40. Other standard features: Voltage stabilizer for control units, Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, single reduction worm gear, electromagnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limits switch, main suspension ropes counter weights lifting hoist for mounting the machineries. 41. Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period not less than one year. 42. Site testing in accordance with IS 14665 should be carried out at the time of handing over. Necessary spares and tools required for the maintenance for a period of one year 43. Supply of operation and maintenance manual with Necessary tools for Operation. The list of tools required should be detailed by the contractor in a separate sheet duly signed by contactor. 44. Provision of mirror in the lift car 45. All the features for differently abled persons should be included as per the act. (Johnson/KONE/ OTIS / Eq.)
HariRam Constructions (BID ID -1417708)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid