Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹3.7 Laccepted-aoc | accepted-aoc |
Tender Value
₹4.9 L
EMD Value
₹12,000
Closing Date
16 Mar 2026, 9:30 pmClosed
Rural Drinking Water and Sanitation Department
EXECUTIVE ENGINEER RWS DIVISION KOPPAL
Supplying and installing of RO Plant in Karnataka Public School at Hiresindogi Village of Koppal Taluka
RWSSD/2025-26/WT/WORK_INDENT9892
RWSSD/2025-26/WT/WORK_INDENT9892
Open
Water /sewage treatment tanks
Electronic Documents, First(One Cover)
RWSSD Division Office Koppal
5 documents required · 5 mandatory
₹500
₹12,000
16 Mar 2026
4 Mar 2026
9 Mar 2026
Water purification plants: Providing, Installation and Commissioning of
automatic Water purification plant (RO+UF) with all accessories piping,
product water tank on single phase power supply as per t...
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipe...
Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and ...
Earth work excavation by manual means for drains,
canals, waste weir draft, approach channels, key
trench, foundation of Buildings & Bridges and such
similar works in all kinds of soils , as per drawi...
Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joint...
Refilling available earth around trenches/pipelines,
cables in layers not exceeding 20 cm in depth,
compacting each deposited layer by ramming after
watering with a lead upto 50 m , and lift upto 1.5
Supplying of special moulded variety PVC couplers as per IS 7834/
1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest
amendments to walk site etc. complete.63mm dia PVC Couplers
Supply and delivery at site special moulded variety PVC bend as per IS
7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its
latest amendments.63 mm dia PVC BEND
ELECTRIFICATION
Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
upplying and drawing Flexible Multicore Cable manufactured with
electrolytic grade flexible copper with low conductor confirming to
IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for
Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to...
Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to...
Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to...
Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with required
nos. of machine screws, bolts nuts etc., complete on the existing
Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using...
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS...
Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit breaking
Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit shoul...
Supplying & fixing retrofit type-PL- LED Lamp . W LED
linear source with CCT 6500 degree K, CRI 70%. efficacy 80
lumen per W, life 25000 burning hours and Compliance to IS
Earthing: Providing and fixing and wiring earth electrode for grounding
circuits IC cutouts and other equipments on the meter board in the pit.
The pits should be filled up with equal proportion of sa...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW 1 FINAL.docx
Tender Document • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .