Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹23.4 L+₹42,739.22 (1.86%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L2 | Rejected-Finance Rejected not being lowest | |
| 3 | L3₹26.2 L+₹3.2 L (13.9%)Rejected-Finance | L3 | Rejected-Finance Rejected not being lowest | |
| 4 | L4₹28.9 L+₹5.9 L (25.6%)Rejected-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Rejected not being lowest | |
| 5 | L5₹30.9 L+₹7.9 L (34.2%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L5 | Rejected-Finance Rejected not being lowest |
| Sl No | Description | Qty | Unit | Commercial Traders L8 | mayur enterprises L4 | Ridhi engineers and builders L2 | ALLIED CONSTRUCTION L3 | KISHORE ENTERPRISES L6 | Vijay Electricals L5 | Microsys Automation India L9 | M/S ADHIKARI CONSTRUCTION CO. L1 | Ayushmat Contractors L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engineer- in- Charge. | 1,220.4 | Cum | 85 ₹1,03,734 | 50 ₹61,020 | 90 ₹1,09,836 | 120 ₹1,46,448 | 90 ₹1,09,836 | 55 ₹67,122 | 70 ₹85,428 | 49 ₹59,799.6 Lowest | 50 ₹61,020 |
| 2.00 | Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge. | 698.68 | Cum | 15 ₹10,480.2 | 20 ₹13,973.6 | 20 ₹13,973.6 | 20 ₹13,973.6 | 30 ₹20,960.4 | 5 ₹3,493.4 Lowest | 5 ₹3,493.4 Lowest | 9 ₹6,288.12 | 10 ₹6,986.8 |
| 3.00 | Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer- in- Charge. | 521.72 | Cum | 20 ₹10,434.4 | 20 ₹10,434.4 | 20 ₹10,434.4 | 20 ₹10,434.4 | 30 ₹15,651.6 | 5 ₹2,608.6 Lowest | 5 ₹2,608.6 Lowest | 9 ₹4,695.48 | 20 ₹10,434.4 |
| 4.00 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge. | 366.12 | Cum | 250 ₹91,530 | 250 ₹91,530 | 250 ₹91,530 | 250 ₹91,530 | 250 ₹91,530 | 200 ₹73,224 | 300 ₹1,09,836 | 99 ₹36,245.88 Lowest | 199 ₹72,857.88 |
| 5.00 | Supplying and Fxingsub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge. | 23.58 | Per 1000 Nos | 2,000 ₹47,160 | 3,500 ₹82,530 | 2,500 ₹58,950 | 2,200 ₹51,876 | 3,000 ₹70,740 | 2,000 ₹47,160 | 3,000 ₹70,740 | 999 ₹23,556.42 Lowest | 1,500 ₹35,370 |
| 6.00 | All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 here in before complete all as specified and directed by Engineer- in- Charge. | 15.72 | Per 1000 Nos | 100 ₹1,572 Lowest | 1,000 ₹15,720 | 500 ₹7,860 | 100 ₹1,572 Lowest | 1,000 ₹15,720 | 500 ₹7,860 | 500 ₹7,860 | 499 ₹7,844.28 | 100 ₹1,572 Lowest |
| 7.00Supplying, laying, jointing testing and connecting in replacement of overhead lines/underground cables, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by Engineer- in- Charge of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule. | ||||||||||||
| 7.01 | 16 Sqmm 4 core | 1,500 | RM | 140 ₹2,10,000 | 125 ₹1,87,500 | 90 ₹1,35,000 Lowest | 119 ₹1,78,500 | 90 ₹1,35,000 Lowest | 110 ₹1,65,000 | 127 ₹1,90,500 | 99 ₹1,48,500 | 90 ₹1,35,000 Lowest |
| 7.02 | 25 Sqmm 3.5 core | 300 | RM | 190 ₹57,000 | 180 ₹54,000 | 120 ₹36,000 | 132 ₹39,600 | 130 ₹39,000 | 126 ₹37,800 | 155 ₹46,500 | 149 ₹44,700 | 110 ₹33,000 Lowest |
| 7.03 | 35 Sq mm 3.5 core. | 500 | RM | 210 ₹1,05,000 | 220 ₹1,10,000 | 150 ₹75,000 Lowest | 157 ₹78,500 | 150 ₹75,000 Lowest | 159 ₹79,500 | 189 ₹94,500 | 179 ₹89,500 | 150 ₹75,000 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT
REPAIR MAINTENANCE REROUTING OF LT CABLES AND CONNECTED ITEMS AT DHAULA KUAN PART II 5 RMC URI ENCLAVE RR COLONY 61 CAVALARY TODAPUR PERIRA ENCLAVE 1 WEC EETSU DASH AEC 48 MVH WESEE SIG CENTRE WEE WKSP BRAR SQUARE YELLOW DOUBLE STOREY BAFFLE RANGE NO
2025_MES_735866_1
GE ELECT/D-70/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹90,000
Yes
9 Jan 2026
17 Oct 2025
10 Nov 2025
17 Oct 2025
7 Nov 2025
31 Oct 2025
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer- in- Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge.
Supplying and Fxingsub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge.
All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 here in before complete all as specified and directed by Engineer- in- Charge.
Supplying, laying, jointing testing and connecting in replacement of overhead lines/underground cables, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by Engineer- in- Charge of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by Engineer- in- Charge.
Supplying and Fxingin replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes complete all as specified and directed by Engineer- in- Charge.
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks complete all as specified and directed by Engineer- in- Charge. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete complete all as specified and directed by Engineer- in- Charge the following sizes :-
16-25 Sqmm x 3.5 core/ 4 core
35-50 Sqmm x 3.5 core
70-95 Sqmm x 3.5 core
120-150 Sqmm x 3.5 core
185 -240 Sqmm x 3.5 core
Suplying and laying as replacement in sub station fixing 3.3 to 11 KV electrical insulation mat of size 5 mtr x 1 mtr x 2.5 mm thick specification as per IS 15652 2006 complete all as specified and directed by Engineer- in- Charge.
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II), complete with cast iron/MS plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screw etc including excavation, earth work, PCC foundation,PCC coping,GI pipe for cable protection etc complete all as per manufacturer's instructions and as specified and as directed by Engr-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed by Engineer- in- Charge.
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swan neck poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II), complete with cast iron/MS plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screw etc including excavation, earth work, PCC foundation,PCC coping,GI pipe for cable protection etc complete all as per manufacturer's instructions and complete all as specified and directed by Engineer- in- Charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed by Engineer- in- Charge.
Supplying and Fxingin replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral with 6 Amps MCB SP including embossing/painting of danger notice on front face of KIOSK box body complete all as specified and directed by Engineer- in- Charge.
Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of appropriate size with 4 Nos 500 Amps aluminium bus bar, RYB indication lamp and with 250 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level complete all as specified and directed by Engineer- in- Charge.
Material and Labour for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by Engineer- in- Charge.
Material and labour in replacement Retro Reflective installation sign boards of size 12 feet x 4 feet fabricated out of 16 gauge MS sheet frame duly welded/riveted with MS square pipe of size 25mm x25mm at height 9.00 meter above ground level on stainless steel heavy duty pipe of size 80mm bore embaded 75 CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx75cm including necessary excavation and earth work .The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The wiriting matter will be in English language on both sides with reflective adhesive painter tapes complete all as specified and directed by Engineer- in- Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed by Engineer- in- Charge and shown in electrical plate number 5 of MES SSR part-I(1991) Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe up to 7.5 meter beyond the earth plates electrode
Supplying and Fxingin replacement of LED Flood light fittings of capacity 120 Watt complete all as specified and directed by Engineer- in- Charge.
Supplying and Fxingin replacement of LED Flood light fittings of capacity 200 Watt complete all as specified and directed by Engr-in-Charge.
Supplying and Fxingin replacement of cable gland for LT panel/feeder pilar for 25 sqmm cable to 95 Sqmm cable complete all as specified and directed by Engineer- in- Charge..
Supplying and Fxingin replacement of cable gland for LT panel for 120 sqmm cable to 300 Sqmm cable complete all as specified and directed.
Supplying and Fxing in renewal on load change over switch open execution of capacity 400 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable changeover from panels etc complete all as specified and directed by Engineer- in- Charge.
Supplying & Fixing in replacement bracket for street light fitting complete with 1.5 to 2.2 mtr long 32/40mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers complete all as specified and directed by Engineer- in- Charge.
Supply and Installation of LT CT operated Trivector Meter with the following specifications complete all as specified and directed by Engineer- in- Charge:- (a) Meter Type: LT 3 Phase 4 Wire Electronic Tri vector Meter (b) Standard: IS 13779:1999 / CBIP 88 (c) Accuracy: Class 0.5 (d) Voltage and Current rating:- (i) Reference Voltage - 3x240 V (ii) Basic Current (Ib) - 5 A (iii) Maximum continuous current (Imax) - 10 A (e) Rated Frequency (variation) - 50Hz (±5%) (f) Power consumption:- (i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency (ii) Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (g) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (h) Display in the event of Power Failure: Internal battery back-up for LCD display (iii) Energy recording - Unidirectional
Supplying and Fxing in replacement ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type , front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection complete all as specified and directed by Engineer- in- Charge.
Supply, drawing, connecting & testing of 3 core, 1.5 Sqmm PVC insulated and PVC rounded sheathed, copper conductor (flexible) industrial cable 1100 Volts grade conforming to IS-694 in steel tubular pole from KIOSK box to light fittings including PVC conduit of size 20mm bore with clamping(Wherever required) and providing suitable copper lugs complete all as specified and directed by Engineer- in- Charge.
Supplying & fixing of LED street light Fitting 45 watt LED, IP-66 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV complete all as specified and directed by Engineer- in- Charge.
Supplying & fixing of LED street light Fitting 60 watt LED, IP-66 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV complete all as specified and directed by Engineer- in- Charge.
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge.
Ridhi engineers and builders (BID ID -3469031)
ALLIED CONSTRUCTION (BID ID -3469325)
mayur enterprises (BID ID -3468815)
Vijay Electricals (BID ID -3469560)
KISHORE ENTERPRISES (BID ID -3469538)
Ayushmat Contractors (BID ID -3474663)
Commercial Traders (BID ID -3467226)
Microsys Automation India (BID ID -3474268)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_824007.xls
BOQ • 0.28 MB
TD70.pdf
Tender Documents • 1.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .