Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.2 LAccepted-AOC H NO 31 DUPLEX MOTIAZ ROYAL FAME VILL CHAJJA MAJRA PO LANDRAN SEC 117 DISTT SAS NAGAR MOHALI PB PIN 140307 | S A S NAGAR | PUNJAB | 140307 | ₹49.2 L | L1 | Accepted-AOC Accept |
| 2 | L2₹49.7 LRejected-Finance | ₹49.7 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹54.0 LRejected-Finance | ₹54.0 L | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹56.3 LRejected-Finance ROOM NO 01 1ST FLOOR SIMA TRADING BUILDING SURVEY NO 268 GARACHARMA VILL SRI VIJAY PURAM 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹56.3 L | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹58.2 LRejected-Finance ATR MAIN ROAD GARACHARMA II OPP MAHINDRA JADWET SHOWROOM SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹58.2 L | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Dharm Singh Contractor L1 | M/s Gurunath Construction L4 | RPG AND COMPANY L5 | BANSAL ENGINEERING L2 | Everest Cooling Works L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 Ltrs and nominal cooling capacity of 40 Ltrs / Hr and dismantling old one and depositing to MES store yard complete all as specified and directed.
Make : Blue Star / Voltas or equivalent | 12 | Each | 61,360 ₹7.4 L | 48,960 ₹5.9 L | 50,660 ₹6.1 L | 63,500 ₹7.6 L | 80,000 ₹9.6 L |
| 2.00 | Supply and fix water cooler with water purifier with comfort level water outlet temperature 17ºC rated condition 40 LPH, UV, sand/ carbon filter system and water cooler operating volt 180 - 250 Volts, Single Phase, 50 Hz, thermal insulation for storage tank, body storage tank material SS 304 and 5 stages of purification, having approx storage capacity of 120 Ltrs and nominal cooling capacity of 60 Ltrs / Hr including suitable pre-filter and dismantling old one and depositing to MES store yard complete all as specified and directed.
Make : Blue Star / Voltas or equivalent | 1 | Each | 1,31,570 ₹1.3 L | 1,64,920 ₹1.6 L | 1,70,660 ₹1.7 L | 1,35,000 ₹1.4 L | 1,95,000 ₹1.9 L |
| 3.00 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of cooling capacity 6000+3% K Cal per hour (2.0 TR) including required gas charging and dismantling old one and depositing to MES store yard complete all as specified and directed. | 13 | Each | 1,02,070 ₹13.3 L | 1,21,165 ₹15.8 L | 1,25,380 ₹16.3 L | 1,04,500 ₹13.6 L | 1,05,000 ₹13.7 L |
| 4.00 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of cooling capacity 4600+3% K Cal per hour (1.5 TR) including required gas charging and dismantling old one and depositing to MES store yard complete all as specified and directed.
Make for item No 3.00 & 4.00 :- Hitachi / Blue Star / Daikin / Voltas / Carrier / Godrej / LG
Note for Item Nos 3.00 & 4.00:
(a) The cost of compressor oil, remote with batteries, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces is deemed to be included in the quoted rate.
(b) Drilling of the wall should be done by core cutting machine.
(c) Quoted rate inclusive of copper piping upto 3 mtr and refrigerant gas upto 3 mtr piping.
(d) Additional cost of copper tubing (>3 mtr), refrigerant gas (>3mtr) & bracket for mounting outdoor unit shall be measured and paid seperately.
(e) Contractor shall submit the proof of authorised OEM/Service dealer at Sri Vijaya Puram before obtaining make approval.
(f) The air conditioner are to be procured from a local dealer with a local services set up back up at Sri Vijaya Puram for emergency rectifications. | 30 | Each | 70,800 ₹21.2 L | 86,800 ₹26.0 L | 89,820 ₹26.9 L | 69,500 ₹20.9 L | 78,000 ₹23.4 L |
| 5.00 | Supply & Fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket completewith one single pole MCB 20 Amps complete all as specified and directed. | 43 | Each | 2,478 ₹1.1 L | 2,670 ₹1.1 L | 2,760 ₹1.2 L | 2,390 ₹1.0 L | 1,900 ₹81,700 |
| 6.00 | M&L for Air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on wall complete all as specified and directed. | 43 | Each Set | 2,360 ₹1.0 L | 2,750 ₹1.2 L | 2,850 ₹1.2 L | 2,290 ₹98,470 | 1,800 ₹77,400 |
| 7.00 | Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +2.5% and of capacity 4.0 KVA complete all as specified and directed. | 13 | Each | 3,953 ₹51,389 | 3,982 ₹51,766 | 4,120 ₹53,560 | 4,000 ₹52,000 | 5,000 ₹65,000 |
| 8.00 | Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +2.5% and of capacity 3.0 KVA complete all as specified and directed.
Make for item No 7.00 & 8.00 :- Luminous / Microtech / V-Guard / Automatic Electrical / Vinitec / Aplab / Vintek Electronics (Volina) | 30 | Each | 3,186 ₹95,580 | 3,300 ₹99,000 | 3,410 ₹1.0 L | 3,200 ₹96,000 | 4,500 ₹1.4 L |
| 9.00 | M & L for submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable two run of 4 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and one run of 4 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire and making good the disturbed wall surfaces to match with existing surface and taking down old u/s submain wiring complete all as specified and directed.
Make :- Plaza / Finolex / Havells / Polycab / Gloster / KEI / Anchor
Note : (i) Three run of cable with one run of PVC conduit/ PVC casing and caping will be measured as one length.
(ii) The quoted rate is inclusive of the following:
(a) Proper colour coding is to be followed as per IS specification.
(b) Test certificate of cables to be submitted before commencement of work/ claiming for payment.
(c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/ PVC casing caping of suitable size as per site requirement. | 170 | RM | 708 ₹1.2 L | 450 ₹76,500 | 400 ₹68,000 | 750 ₹1.3 L | 290 ₹49,300 |
| 10.00 | Supply & laying of CPVC pipes of 25 mm outer dia, SDR 11 & plain CPVC SDR 11 fittings for drain out AC condensation with complete fixed on wall with suitable clamps complete all as specified and as directed. | 90 | RM | 472 ₹42,480 | 560 ₹50,400 | 550 ₹49,500 | 440 ₹39,600 | 320 ₹28,800 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
14 Jan 2026, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
8677/E8 - SPECIAL REPAIRS FOR REPLACEMENT OF OLD VINTAGE / BER SPLIT AC AND CONNECTED ACCESSORIES AT INS UTKROSH AND PROVISION OF 06 IN NUMBER AIR CONDITIONING UNITS (1.5 TON EACH) AT VARIOUS LOCATION FOR NCN EQUIPMENT AT HQ 34 WEU) UNDER GE MINNIEBA
2025_MES_745883_1
8677/E8
Open Tender
Civil Works
180 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Yes
GE, Minniebay
₹99,000
Yes
17 Mar 2026
24 Dec 2025
16 Jan 2026
24 Dec 2025
14 Jan 2026
7 Jan 2026
Supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 Ltrs and nominal cooling capacity of 40 Ltrs / Hr and dismantling old one and depositing to MES store yard complete all as specified and directed. Make : Blue Star / Voltas or equivalent
Supply and fix water cooler with water purifier with comfort level water outlet temperature 17ºC rated condition 40 LPH, RO system and water cooler operating volt 180 - 250 Volts, Single Phase, 50 Hz, thermal insulation for storage tank, body storage tank material SS 304 and 5 stages of purification, having approx storage capacity of 120 Ltrs and nominal cooling capacity of 60 Ltrs / Hr including suitable pre-filter and dismantling old one and depositing to MES store yard complete all as specified and directed. Make : Blue Star / Voltas or equivalent
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 2.0 TR including required gas charging and dismantling old one and depositing to MES store yard complete all as specified and directed.
Supply & Fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket completewith one single pole MCB 20 Amps complete all as specified and directed.
M&L for Air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on wall complete all as specified and directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +2.5% and of capacity 4.0 KVA complete all as specified and directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +2.5% and of capacity 3.0 KVA complete all as specified and directed. Make for item No 7.00 & 8.00 :- Luminous / Microtech / V-Guard / Automatic Electrical / Vinitec / Aplab / Vintek Electronics (Volina)
Supply & laying of CPVC pipes of 25 mm outer dia, SDR 11 & plain CPVC SDR 11 fittings for drain out AC condensation with complete fixed on wall with suitable clamps complete all as specified and as directed.
Supply and charging environmental friendly refrigerant gas or any other as per OEM recommendations
Supply and fixing of Copper tubing of size 1/2" or 1/4" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and directed.
Supply and fixing of Copper tubing of size 3/8" or 5/8" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and directed.
Supply & Fix rigid non-metallic PVC conduit heavy duty 25 mm dia inclusive of all fittings and fixing accessories complete all as specified and as directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_835187.xls
BOQ • 7.13 MB
8677TENDER.pdf
Tender Documents • 0.87 MB
Download all tender documents and submit your bid