Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC L1 bidder quoted rates | |
| 2 | L2₹32.3 L+₹46,988 (1.48%)Rejected-AOC | L2 | Rejected-AOC Not quoted L1 rates | |
| 3 | L3₹34.6 L+₹2.8 L (8.72%)Rejected-AOC 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L3 | Rejected-AOC Not quoted L1 rates |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Oct 2023, 6:00 pmClosed
CWE PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
81751 REPAIR AND COMPREHENSIVE MAINT OF EARTHING INFRASTRUCTURE WATCH TOWER AUTOMATIC CLOCK, STRETCHER CUM PASSENGER LIFT AND ASSOCIATED CONNECTED ITEMS AT NDA KHADAKWASLA UNDER GE (NDA) KHADKAWASLA
2023_MES_619742_1
81751 CWE PUNE
Open Tender
Civil Works
Item Rate
273 days
GE (NDA) KHADAKWASLA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NDA) KHADAKWASLA
₹80,000
27 Jan 2024
20 Sept 2023
21 Oct 2023
20 Sept 2023
19 Oct 2023
5 Oct 2023
Amount
Labour only for cleaning the vegetation/surplus soil around the earth pits upto 1.00 mtr all around the pit, cleaning the chamber of the earth pit, replacing the rusted earthing leads/funnel / mesh with new ones etc checking the results of the earthing using earth tester, re-activating the earth pit using suitable measures as required to bring the results within the limits of 1 ohm complete all as specified and directed by Engineer Incharge. NOTE :i) All materials required for re-activation of earthing pit will be measured and paid separately under supplied & fixed only of respective items of schedule. ii) The quoted rate is deemed to be including of the resistance test of earth pits to be carried out by contractor and nothing extra shall be permissible on this account.
Supply & fixing of common salt suitable for earth pits complete all as specified and directed by Engineer Incharge.
Supply & fixing of magnesium sulphate suitable for earth pits complete all as specified and directed by Engineer Incharge.
Supply & fixing of Charcoal used for earth pits complete all as specified and directed by Engineer Incharge.
S&F in replacement of test point terminal block made of gun metal / phosphorus bronze/copper of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw complete all as specified and directed by Engineer Incharge.
S&F in replacement of copper strip 32 x 6 mm with saddles and fixing screws etc for roof/down conductor above ground including jointing with rivets/ brazing etc all as directed by engineer-in-charge complete.
S&F in replacement of copper strip 20 x 3.15 mm with saddles and fixing screws etc for roof/down conductor above ground including jointing with rivets/ bracing etc all as directed by engineer-in-charge complete.
S&F inreplacement of air termination single pointed solid Aluminium rod 12mm dia, 300mm long mounted roof of building complete all as specified and directed by Engineer Incharge.
S&F in replacement aluminium strip 25 x 3 mm with saddles /insulators every 1 mtr of interval and fixing screws etc for roof/down conductor above ground including joining with rivets, bolts, nuts, washers etc on the roof of SQN buildings necessary scafolding work or protective arrangement made by contractor. The rate for the same deemed to be included in the quoted rate complete all as specified and directed by Engineer Incharge.
M&L for chemical earthing complete with Copper earth plate electrode 90cmx60cm x 5 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including Copper strip of 32x6mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of GI protection pipe light grade of 40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore medium grade, wire mesh and lugs, test point including salt, Coal & Magnesium sulphate etc. complete all as specified and directed by Engineer Incharge. Note: Copper strip exceeding 7.5m long shall be measured & paid separately. If the earth resistance value failed to achieve less than 1 ohm, the contractor shall re-do the earthing without any extra cost.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip of 32x6mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of HDPE/GI protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore , wire mesh and lugs, test point etc. complete all as specified and directed by Engineer Incharge. Note: G I strip exceeding 7.5m long shall be measured & paid seperately.
M&L for maintenance free grounding Solution set earthing comprising of 17.2 mm pure copper earthing rod, 3m long, Copper terminal size of 100x50x6mm with 2 Nos M8 holes for termination. Electrode must be tested for a short circuit test of minimum 40 KA at CPRI/NABL. The earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5 Mtr. The bore drilling will be done with the help of a Pneumatic boring machine, 50 Kgs BFC will be placed in the bore to cover the earthing rod from all sides. BFC will be poured in Slurry form in a properly mixed condition. The Earth pit cover Square 300x300x240 mm to be provided to cover the Earth Pit and shall be made of reinforced FRP and should be capable of carrying the weight of 5 Tons. NOTE :- (a) Rates of boring 3.5 Mtr for earth electrode, GI strip 25x3 mm upto 7.5 Mtr from earth electrode is deemed to be included in the quoted rate. (b) On testing, after completion, if the earth resistance <3 ohms is not obtained, earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained. (c ) Test certificate from the OEM has to be produced by the contractor for the material used in earthing.
Supply and installation, commissioning of ESE Lightning Arrester as per following Specification ESE Lightning Arrester, Installtion of LA on 5m long mast with guy rope and other accessories Test Link Box ( MS Powder coated box size of 300mmX120mmX 100 mm), ESE LA Counter, Guy Rope & accessories and ESE LA Installation on high raising buildings necessary scafolding work or protective arrangement made by contractor complete all as specified and directed by Engineer Incharge.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI wire 4 mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of GI protection pipe light grade of 40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore , wire mesh and lugs, test point etc. complete all as specified and directed by Engineer Incharge. Note: G I earth wire exceeding 7.5m long shall be measured & paid seperately.
S&F for 70 Sqmm single core multistranded Copper Cable, 1100 Volts PVC insulated on wall / roof of building with clamps for connection of ESA lightening arrestor to earthing terminal with copper lugs, SS nut bolts and washers accessories as per site requirement complete all as specified and directed by Engineer Incharge.
Supply & Laying in trenches or fixing on wall/floor/ceiling GI tubing "Medium Grade" 15 mm bore with all standard fittings such as suitable size of MS clamps, screws, hooks, Elbow, bends, tees etc complete all as specified and directed by Engineer Incharge. Note : Necessary Excavation and Earth work shall deemed to be included in the quoted rate by the tenderer.
S&F of Bronze/Gun Metal Gate Valves (Hexagonal type) 15 mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer Incharge.
S&F of Bib tap /Stop Cock of any colour, 15 mm dia, screwed for pipes high pressure (minimum weight 90 gms) complete all as directed by Engr-in-Charge.
Cutting of existing steel tubing for alterations or addition in position without taking down and screwing for addition of Tee, etc for 20 mm bore connection. complete all as specified and directed by Engineer Incharge. (Note :- The cost of excavation , earthwork and fitting of pipe line required at site shall be deemed to be included in unit rate quoted by the tenderer)
M&L For earth chamber of internal size (600X600) mm made up of PCC 1:3:6 type C1 chamber, with precast cover of slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame including earthworrk and excavation in any strata as per electrical plate No 5 of SSR Part I (2009) complete all as specified and directed by Engineer Incharge.
Comprehensive maintenance on quarterly basis of stretcher cum passenger lift with AC variable voltage and variable frequency (VVVF) having closed loop automatic centre opening sliding steel doors for serving Ground plus 1st floor, in order to ensure round the clock functioning of the lift. The scope of work includes servicing and maintenance of lift machine ,inspection of lift machine including control panel and other accessories/components as per manufacturer maintenance manual/schedule and carring out quarterly maintenance of lift. The technical specification of the lift car as under below :-
(a) Make of the lift : Monarch (b) Type of lift : Hospital auto lift (c) Load carrying capacity : 1020 Kg (d) Speed : 0.5 mtr/sec (e) Power supply : 415 Volts, 3-ph, AC 50 Cycles & (f) Car Travel : Ground + 1st Floor
(g) Car size & type : (1100 x 2400)mm stainless steel hair line finish with infra red door safety AL chequered plate flooring (h) Car operating pane- (h) Note : (i) For servicing & maintenance purpose required all consumable and other spare parts shall be measured and paid seperately. (ii) Servicing & maintenance of spares will be carried out by well experienced lift Technician/Mechanic/authorised service expert of manufacturer. (iii) The certificate produce by contractor regarding lift is fit for operation.
S&F in replacement of Integrated control main mother board suitable /Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of 24 Volt SMPS Power card suitable / Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Rectifier card suitable / Compatible to existing lift complete all as specified and directed.
S&F in replacement of 12 Volt relay board suitable / Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Contactors 32A , 3 Pole 3 NO+3 NC-110 Volt coil supply With auxiliary and add on block suitable /Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Contactors 50A , 3 Pole 3 NO+3 NC-230 Volt AC coil supply With auxiliary and add on block suitable / Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of 110 Volt AC OEM Relay Board suitable /Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of 415 Watt –Transformer 415 to 110 AC suitable /Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Line chowk 3 phase for phase protection suitable / Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of SPP- Single phase Preventer suitable /Compatible to existing lift complete all as specified and directed.
M&L for PVC wiring connector to controller board suitable /Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of 3 phase VVVF Drive 12 HP 8.9 KW suitable/ Compatible to existing lift complete all as specified and directed.
S&F in replacement of Limit switch, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Car gate switch, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Safety Switch, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Lock Contact, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Car door belt – formator suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Guide shoe Liner, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of OSG Switch, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Door sensor, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of LED Seven segment display board suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Car & Landing push button part complete, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F for Up / Down Arrow indicator, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Door shoe, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement Cabin fan, 230 volt, 1-phase, 3 star BEE rating, SS Body, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Cabin light, 230 volt LED Ceiling mounted SS Body , suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Break shoe liner, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
M&L for Control Copper cable of size 0.5 sq mm 12 core, multi standard Suitable for 1100 Volts, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F for Copper thimble, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
S&F in replacement of Bull dog clip / ‘U’ Clamp, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
M&L for maintenance, repair and Overhauling of complete gear box Assembly of existing lift, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
M&L for gear oil , suitable/ Compatible to existing lift gear box assembly complete all as specified and directed by Engineer Incharge.
Supply and fix for ball bearing heavy duty suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
Supply and fix for gear oil seal, suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
M&L in replacement of Car door made up of SS 304 small vision 200 X 600 MM with fire proof laminated glass 900 MM clear opening height 2100 MM with car header, door drive, coupler , motor , door belt etc with complete accessories make formator complete all as specified and directed by Engineer Incharge.
Supply and fixing in repair Automatic rescue device (ARD) By replacing its all worn out / unserviceable parts / operational including testing and commissioning complete all as specified and directed by Engineer Incharge.
S&F in replacement Exide Power safe sealed lead Acid Battery, 12 Volts, 7 AH (EP 17-12) , with voltage Regulation (27 Deg C ), Standby use 13.6 V- 13.8 V , Max Initial Current 3.4 Amp suitable/ Compatible to existing lift complete all as specified and directed by Engineer Incharge.
M&L in replacement of landing door made up of SS 304 small vision 200 X 600 MM with fire proof laminated glass 900 MM clear opening height 2100 MM with opening header make formator including connected accessories complete all as specified and directed by Engineer Incharge.
M & L for Dismantling and taking out carefully existing one face of tower clock completely and servicing, repairing and overhauling of the Clock Hands, GPS synchronized time server master control units (MCU) with GPS Antena , GPS synchronizing circuit and one units with high torque stepper motors and its driving gears and spindles etc of the clock hands of 9' diameter tower clock. The work includes checking of all electrical connection of one face of Tower clock and LED based illumination of the hands and indices complete as per site requirement. Note : -(i) The rates quoted against the Item is deemed to be included for cost of labour, minor parts for repair. (iii) Any damage to Parts of Tower Clock during the execution of Item and while in the custody of the contractor shall be made good at no extra cost to dept.
M &L for The synchronizing of all one face with GPS real timing to reset / correct the time on resumption of the contact with satellite time, if it finds any deviation. The Auto Re-set Indexing System shall be capable of bringing back the clock hands to 12:00 clock position and then start counting time and give required pulses to move the clock-hands to the actual time of the day without any manual setting and also automatically re-set the time on resumption of power after a power-break. The items require for functionalling to be included in it complete all as specified and directed by Engineer Incharge.
M & L in repalcement of drive unit of Hands with two High Torque 12V DC, 270 Ohm, stepper motors of 1.8 degree inside the driving unit to move the Hour-hand and Minute-hand independently complete all as specified and directed by Engineer Incharge.
M & L in repalcement of reduction gear assembly suitable for tower clock assembly complete all as specified and directed by Engineer Incharge.
S & F in replacement of master controller unit for GPS synchronisation with power supply arrangement complete all as specified and directed by Engineer Incharge.
S & F in replacement of GPS antenna assembly ccomplete all as specified and directed by Engineer Incharge.
M & L in replacement of back up system of 12 Volts 9 AH capacity dry type suitable to existing tower clock system complete all as specified and directed by Engineer Incharge.
M&L for brought out high raising over head crane/boom at site for doing external repair work for replacement of unserviceable parts on the facia of tower and carry out servicing and maintenance of tower clock all as specified and as directed by Engineer Incharge.
M & L in repalcement of LED Illumination, colour as directed of one face of 9' dials (Indices & clock hands) LED lighting :- Each face of the 9' dia tower clock shall be provided with following LED lighting arrangment of reputed brand suitable for outdoor :- a) Illumination for the dial (Indices) : Total 175 modules of 0.75 watts each distributed as 75 modules for 4 Indices (22"x 6") and remaining 100 modules for 8 Indices (16"x 6") controlled by one SMPS of 20 Amps. b) Illumination of the Clock Hands: Total 50 modules of 0.75 watts; 30 modules for Minute hand and 20 modules for Hour Hand controlled by one SMPS of 5 Amps Note - Necessary working platform / scaffolding for fixing the LED illumination system on the external face of the tower (clock) at MP Block (approx height of Clock 40 Mtr from ground lavel) shall be arranged by the contractor and the unit rate quoted is deemed to be included in the cost work.
M & L in replacement of 110- 240 V +15% AC, 50 Hz input and 12V DC, 20 Amp output SMPS suitable to existing system of tower clock LED illumination of the dial (indices) complete all as specified and directed by Engineer Incharge.
S & F installation and commissioning in replacement of new tower clock assembly having operating voltage range 12 Volt to 16 Volt dc current rating 600 mA when motor is running and 80 mA when ideling speed, temperature range 0 to 80 degree celsius, supported dial size up to 12 feet dial diameter and GPS fixing time less than 1 minute including its accessories as per existing sample complete all as specified and directed by Engineer Incharge.
M & L in replacement of 110- 240 V +15% AC, 50 Hz input and 12V DC, 5 Amp output SMPS suitable to existing system of tower clock LED illumination of the dial (indices) complete all as specified and directed by Engineer Incharge.
S & F in replacement of digital timer switch, suitable for working between 110 to 240 V, AC, 50 Hz and capable for setup of 25 programs or suitable/compatible to existing tower clock system and also for siren complete all as specified and directed by Engineer Incharge.
S&F in replacement of GI Strip 32 x 6 mm with saddles and fixing screws etc for down conductor above ground including jointing with rivets/ bracing etc complete all as specified and directed by Engineer Incharge.
S&F in replacement of GI earth wire 4 mm dia with fixing screws etc for down conductor above ground including jointing with rivets/ brazing etc complete all as specified and directed by Engineer Incharge.
J B ELECTRICALS
KESARI AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .