| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.5 LAccepted-AOC CAMP TENGA MARKET P O P S TENGA VALLEY DIST WEST KAMENG ARUNACHAL PRADESH PIN 790 116 | WEST KAMENG | ARUNACHAL PRADESH | 790116 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹47.0 L+₹1.5 L (3.34%)Rejected-Finance | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹48.1 L+₹2.7 L (5.87%)Rejected-Finance | L3 | Rejected-Finance HIGH BID VALUE | |
| 4 | L4₹48.3 L+₹2.8 L (6.22%)Rejected-Finance | L4 | Rejected-Finance HIGH BID VALUE | |
| 5 | L5₹48.3 L+₹2.9 L (6.33%)Rejected-Finance | L5 | Rejected-Finance HIGH BID VALUE |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
24 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL K SENTHIL KUMAR
GE 859 EWS PIN 913859 C/O 99 APO
PROVN OF 150 USERS SEPTIC TANK AND 250 MTR DRAINAGE FROM RP GATE TO OTM AT 30 RAJPUT PROVN OF RETAINING WALL
2020_MES_373913_3
8121/E8
Open Tender
Civil Works
Item Rate
180 days
TENGA VALLEY
AS PER NIT
8 documents required · 8 mandatory
₹500
GE 859 EWS
₹88,000
Yes
19 Mar 2021
15 Oct 2020
26 Oct 2020
15 Oct 2020
24 Oct 2020
17 Oct 2020
60 days
Amount
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and getting out in hard/dense soil complete all as specified and directed.
Rough excavation n exc. 1.5m deep for foundation and getting out in hard/dense soil complete all as specified and directed.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft /loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation and getting out in hard/dense soil complete all as specified and directed.
Add to Srl Item No 4 here in before for each additional 1.5m or part there of in depth beyond the first 1.5m.
Excavation over areas n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and directed.
Add to Srl Item No 6 here in before for each additional 1.5m or part there of in depth beyond the first 1.5m.
Returning filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm thick, in any type of soil complete all as specified and directed.
Removal of surplus soil of distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all as specified and directed.
Extra for forming fair finished drain for channel 30 cm inner girth in cement concrete using extra cement incl forms, moulds , mitred/stopped ends etc.
M & L for 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces with WPC @ 3% by weight of cement on internal wall surfaces, finishing the surfaces even & fair.(WPC shall be measured and paid separately)
Supply only integral water proofing compound ISI marked on packet.
M&L for precast PCC (1:2:4) bond stone, type B-1 using 20mm graded aggregates and set in cement mortar (1:6) complete all as specified and directed.
Material and labour for providing pre-cast RCC (1:2:4) type 'B-1' using (20 mm graded crush stone aggregate) as in cover slabs of manholes and similar location including necessary form work and set in cement mortar (1:4) complete all as specified and directed.
M&L for 75mm thick plain cement concrete type C-2 (1:3:6) using 40 mm graded aggregates as in sub base complete all as specified and diretced.
M&L for 75mm thick plain cement concrete type C-2 (1:3:6) using 40 mm graded aggregates as in plinth protection finished even and smooth without using extra cement complete all as specified and diretced.
S&F 3mm thick and 38mm wide glass dividing strips, inserted in position to conform to design complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
S & F TMT bar 10 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
All as per Srl Item No 19 here in before but for 6 to 8 mm TMT bar as in stirrups.
M&L for formwork to edges of concrete flat, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed.
S&F PVC (SWR) pipe 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipe 160mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
Material and labour for providing plain cement concerete (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 110 mm on after they are laid and tested complete all as specified and directed.
Material and labour for providing plain cement concerete (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 160 mm on after they are laid and tested complete all as specified and directed.
Supply & fix PVC (SWR) vent cowl 110 mm dia complete all as specified and directed. Make :- Supreme/Kisan/Tirupati/Finolex/Prince.
M&L for providing reinforced cement concrete type B1 1:2:4 (using 20 mm graded aggregate) as in slabs supported on walls, beams and column in floors, roofs, landings complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for providing plain cement concrete type B1 1:2:4 (using 20 mm graded aggregate) as in floorings complete all as specified and directed.
S&F Gun metal globe or gate valve with Iron wheel head, screwed both ends for 20 mm dia of pipe and fixed complete all as specified and directed.
M&L for hard core of broken stone or boulders, gauge n exc 63mm, deposited, spread and levelled in layers n exc 15 cm thick , watered and rammed to true surfaces complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (using 20mm graded aggregates) as in roof kerbs or mud stops, rounded or chamfered on edges, coping etc including necessary formwork complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (40 mm graded stone aggregate) as in surface channels, drains, breast walls, swaged poles foundation etc including necessary formwork complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (20 mm graded stone aggregate) precast cement concrete block masonary with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (40 mm graded aggregate) precast cement concrete block masonary with solid blocks 10 cm thick and setting in CM 1:6 etc complete all as specified and directed.
M&L for walling of random rubble, uncoursed well bonded and solidly hearted and built in cement mortar 1:6 complete all as specified and directed.
Extra over stone walling granite or trap stone for hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc. 40 mm and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
M&L for raised pointing to random rubble masonary uncoursed or brought upto course in cement mortar 1:4 complete all as specified and directed.
M&L for hand packing with broken stone/ boulder behind backing of retaining wall, in layers etc complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:6 on concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and directed.
S&F 15 mm bore steel water tubes, medium grade, galvanised with all fittings fixed to walls or laid on floors complete all as specified and directed.
S&F 20 mm bore steel water tubes, medium grade, galvanised with all fittings fixed to walls or laid on floors complete all as specified and directed.
Taking up or down 20 mm bore steel water tube with all fittings, cleaning and re-fixing in new or old position fixed to walls or laid on floors complete all as specified and directed.
S&F bib tap chromium plated cast copper alloy, fancy type, 15mm dia with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and directed.
Material and labour for 40 mm thick PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) finishing the top surface even and smooth without using extra cement complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Supply and Fix 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screws and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over one coat of red oxide including preparing new zinc (or galvanised) surfaces to receive painting by coating with mordant solution including washing and cleaning etc on steel surfaces of any description complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over one coat of red oxide including preparing new steel surfaces of any description over 10cm in width or girth not otherwise described complete all as specified and directed.
S&F sinks with drainage board made of stainless steel 1.00 mm thick kitchen with plug washers, washers including bedding in cement mortar on dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm with bowl size 410x330x160mm comp complete all as specified and directed.
S&F plate rack made of stainless steel 0.50mm thick,over all size 762mm(H)x787mm(W)x254mm(D) complete all as specified and directed.
S&F 40mm bore LDPE pipes of pressure rating 6 kgf/sqcm complete all as specified and directed.
M/S R L SHARMA
M/S ASHOK CONSTRUCTION
M/S N D ENTERPRISE
M/S SARAI SUPPLY SYNDICATE
M/S DKT CONSTRUCTION
M/S SUNRISE CONSTRUCTION AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .