Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹15.6 L+₹2,026 (0.13%)Rejected-AOC 217 ARHAT BAZAR KASAULI DISTT SOLAN HP 173204 | SOLAN | HIMACHAL PRADESH | 173204 | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹16.2 L+₹61,146 (3.92%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹17.0 L+₹1.4 L (9.23%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 5 | L5₹17.3 L+₹1.7 L (11.0%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
26 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
RAHUL MEENA IDSE EE
MES OFFICE GE KASAULI DISTT SOLAN HP
REPAIR AND MAINT OF LT FEEDER BOX CABLES SUMMER APPLIANCES AND CONNECTED WORKS AT KASAULI AND DAGSHAI UNDER GE KASAULI
2021_MES_497615_2
GEK-72/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KASAULI AND DAGSHAI UNDER GE KASAULI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KASAULI
₹32,000
Yes
7 Mar 2022
1 Feb 2022
5 Mar 2022
1 Feb 2022
26 Feb 2022
14 Feb 2022
60 days
Amount
Schedule 'A' Section - I
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in hard/dense soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for taking out old unserviceable with supply, laying, fixing Double walled corrugated HDPE duct pipe of 50mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed.
All as per item No 4.00 here in before but of 90mm outer dia complete all as specified and directed.
Dismentling taking out carefully old/unserviceable UG cable of any type/ size from trenche/pole/duct/LT panel after disconnecting from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit.
M&L for passing through pipe testing and commissioning of 1100 Volts grade 'Heavy duty' PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed of size 10 Sqmm nominal cross sectional area 2 core with suitable glands and lugs as per site requirement confirming to IS specification, complete all as specified and directed .
All as per item No. 7.00 here-in-before but 16 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 7.00 here-in-before but 25 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 7.00 here-in-before but 35 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 7.00 here-in-before but 50 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 7.00 here-in-before but 120 Sqmm 3.5 core complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode 6mm thick of size 600x600 mm buried directly and vertically in ground with top edge of the plate not less than 2.25 mtr from GL, connected with galvanised iron strip 32x 6 mm all as shown in Plate No-3, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx50mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 25 mm dia light grade GI tubing for protection of GI Strip 32x6 mm, charcoal and salt in alternate 150mm thick layers around GI earth plate, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion
M&L for restraining of ACSR conductor of any size of 2 conductor on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumper connection and insulator binding with aluminium conductor providing required T&P all as specified and directed
S&F MCCB 630 Amps 4 Pole 415 V, 50 Hz adjustable thermal type ( 80% to 100% ) and adjustable magnetic setting, breaking capacity 36 KA , ICS =100 ICU with extended terminals connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
All as per item No 15.00 here in before but MCCB 400 Amps 4 Pole, 36 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 15.00 here in before but MCCB 250 Amps 4 Pole, 36 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 15.00 here in before but MCCB 160 Amps 4 Pole,16 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 15.00 here in before but MCCB 100 Amps 4 Pole,25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 15.00 here in before but MCCB 63 Amps 4 Pole,25 KA, 415 V, 50 Hz complete all as specified and directed.
S&F On load change over switch, four pole with advance neutral 400 Amps, 415 V, 50 Hz conforming to IS : 13947 Part-3 connecting up in the existing panel location including taking out existing unserviceable change over switch complete all as specified and as directed and as directed by Engineer-in-charge.
S&F GI tubing light grade 80mm bore, ISI marked, for cable protection, road crossing etc complete all as specified and directed.
S&F 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 6 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire from OH conductor to building incl dismentling taking down unserviceable one all as specified and directed.
All as per item No. 23.00 here-in-before but 10 Sqmm complete all as specified and directed.
All as per item No. 23.00 here-in-before but 16 Sqmm complete all as specified and directed.
M&L for painting of steel tubular pole with one coat of alumium paint incl cross arm, bracings, supports, nuts, bolts, of LT OH line from above copping to top of pole and marking with alternate Yellow and black paint strip 30 cm wide (5 Nos) with synthetic enamelled paint all as specified and directed.
M&L for trimming of branches of trees touching LT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height 7 mtr and above and carrying and depositing where directed not exceeding 50 mtr.
S&F rigid PVC line spacer, suitable for 2 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade including taking down unsv one all as specified and directed.
S&F rigid PVC line spacer, suitable for 5 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade including taking down unsv one all as specified and directed.
Supply only greese for different component of electrical equipement as directed and specified by Engineer in charge.
S&F enclosure suitable for 4 POLE MCCB 100 A/250A with incomming and outgoing glands including taking out existing unserviceable Enclosure complete all as specified and as directed by Engineer-in-Charge.
Cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE insulated armoured aluminium conductor cable of size 120 sqmm to 185 sqmm including dismantling / taking down unserviceable jointing kit complete all as specified.
Cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE insulated armoured aluminium conductor cable of 50 to 95 sqmm size including dismantling / taking down unserviceable jointing kit complete all as specified.
Disconnecting defective voltage stabilizer indoor type servo controlled , oil cooled 3 phase of capacity 25 KVA draining out complete stabilizer oil & storing the same in suitable containers ( to be arranged by contractor ) opening the top cover and disconecting unsv servo motors , lifiting up core assembly carefully to check the condition of widing and core . Retanking the same after repair refilling the transformer oil after dehydration and filteration, including checking of leakage of transformer body and welding works required for making transformer body leak proof transportation of transformer to and from site to work shop and re-installation the same at any site complete all as specified and directed.
All as per item No. 34.00 here-in-before but 75 KVA voltage stabilizer complete all as specified and directed.
All as per item No. 34.00 here-in-before but 100 KVA voltage stabilizer complete all as specified and directed.
All as per item No. 34.00 here-in-before but 250 KVA voltage stabilizer complete all as specified and directed.
M&L for replacement of burnt /defective stabilizer copper coil with new one made out of super enamelled heavy duty copper wires of size matching to the existing one including varnishing, drying and insulating material in transformer complete all as specified and directed.
S&F in repair single phase AC servo motor(as per sample) suitable for voltage stabilizer of cap 250 KVA complete all specified and directed.
Filtration / dehydration of transformer oil in situ till dielectric strength of min 40 KV is achieved, Servo voltage stablizer, capacity 25 KVA to300 KVA indoor / outdoor type, installed at various electric sub stations / pump houses at Kasauli and Dagshai AOR of AGE E/M Kasauli complete all as specified.
Topping up / replacement of transformer oil with new transformer oil suitable for working voltage 430 volts grade including necessary dehydration to achieve dielectric strength min 60 KV at 2.5mm gap complete all as specified. Notes for serial item No 40.00 & 41.00:- (a) New transformer oil shall be bought in company sealed IS marked container with test certificate. (b) Filtration / dehydration of transformer oil shall be carried out at the location where transformer is installed under the AOR of AGE E/M Kasauli and Dagshai and necessary filteration / dehydration plant having pressure gauge, hour meter, temperature gauge shall be brought to site by contractor including electric supply arrangement to run the dehydration equipment and unit rate quoted shall deemed to include the cost of the same.
S&F fix in repair plug in control card (PCB) for 3 phase servo controlled voltage stabilizer of cap 250 KVA (As per Sample)
S&F fix in repair plug in control card (PCB) for 3 phase servo controlled voltage stabilizer of cap 75 KVA (As per Sample)
M&L for repairing servicing of APFC panel board of Cap 50 KVAR by replacing tha all defective components with new components , re wiring , cleaning , testing, reconnecting , reinstalling and commissioning the APFC panel board complete all as directed by Engineer-in-charge. Note : -(i) Supply of cables, wires & other minor spare parts etc. will deemed to be included in the quoted rate.
M&L for repairing servicing of APFC panel board of Cap 100 KVAR by replacing tha all defective components with new components , re wiring , cleaning , testing, reconnecting , reinstalling and commissioning the APFC panel board complete all as directed by Engineer-in-charge. Note : -(i) Supply of cables, wires & other minor spare parts etc. will deemed to be included in the quoted rate.
Dismentling and Supply , install, connect, test and commission , 3 phase, heavy duty, explosion proof, self healing capacitor cylindrical type confirming to IS 13340 of following ratings :-
1 KVAr heavy duty
2 KVAr heavy duty
3 KVAr heavy duty
4 KVAr heavy duty
5 KVAr heavy duty
10 KVAr heavy duty
15 KVAr heavy duty
20 KVAr heavy duty
Supply and fix the following switch gear/components in various APFC Panels installed at Kasauli & Dagshai sub station /pump houses
MCCB 16A TP, 25 KA
MCCB 25 A , 25 KA
Supply and fixing 200 Watt LED flood light luminaine with ultra sleek ,light weigHT and with secondary optics ,made of pressure die-cast housing with IP 66 ingress protection and impact resistance of IK 07 4 kv inbuilt and 10kv internal singe protection all as specifed and directed.
Supply only nut and bolts of different size used in different electrical equipement all specified and directed.
Supply and fixing tower bolts, locking arrangement , welding works etc to fix cover of existing different size LT Panel properly all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in Coping of LT POLES etc ,finishing even and smooth without using extra cement , complete all as specified and directed.
M & L Painting on coping of LT Poles of existing sizes with samosam with proper coating all as specified and directed.
S&F LED Street light fitting 45Watt new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver.
S&F Security light Bracket made out of galvanised steel light grade pipe of 40mm dia 1.2 mtr long bend to an angle of 120 degree with 02 Nos mild steel clamp 50mm x 50mm and 04 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer incl dismentling taking down unsv complete all as specified and directed.
S&F Street light junction box of size 200mm x 140mm x 95mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable/wire complete comprising with the followings incl dismentling taking down unsv complete all as specified and directed. :- (a) Bus bar with two aluminium strips, 63 Amps capacity insulated with insulators, including colour coding, including PVC cable of suitable size from bus bar to MCB (b) MCB SPN 5 to 30 Amps - 01 No (c) Clamps made out of 25mm x 3mm flat iron duly weldedwith nuts & bolts complete all as specified and directed.
M&L for servicing/maintenance of Refrigerator of any capacity in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, strains complete checking serviceability of electrical circuit of unit, thermostat knob, fans if provided in frost free model, relays, thermostat, trays including replacement of unserviceable spares such as relays, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit for Make of Refrigerator-Samsung/LG/Bluestar/Whirlpool. Note: (i) Spares required for replacement on minor repair as mentioned shall be measured and paid as supply only under appropriate item of this schedule and labour charges shall deemed to be included in the quoted rate of this item. (ii) Items required for major repair shall be measured and paid as M&L under appropriate item of this schedule and rate shall be exclusive of quoted rate of this item.
Supply only following company recommended spares as per original of refrigerator any cap after dismentling taking out unsv one for make of refrigerator -Samsung/LG/Bluestar whichever applicable.
Starting relay
Thermostat
Bottle support as per existing make & model
Chiller trays small as per existing make & model
Sliding trays large as per existing make & model
Supply & fix new company sealed reciprocating compressor unit for refrigerator Make-Samsung/LG/Bluestar whicever applicable of capacity 190 ltr to 321 ltr with required nuts, bolts & washers, connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A after dismentling/taking out existing unserviceable/burnt compressor unit from the refrigerator in wksp and and testing after completion to entire satisfaction of Engr-in-Charge and user unit. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of Refrigerator. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule. (iii) Company test certificate and warantee certificate shall be submitted to dept.
Supply & fix new condenser unit for refrigerator Make-Samsung/LG/Bluestar whicever applicable of capacity 165 ltr to 310 ltr with required nuts, bolts & washers, connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A after dismentling/taking out existing unserviceable unit from the refrigerator in situ and and testing after completion to entire satisfaction of Engr-in-Charge and user unit. Note: (i) Condenser unit shall be compitable model and make shall be as recommended by the manufacturer of Refrigerator. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
M&L for servicing/maintenance of Deep Freezer of capacity 200L/310L Make-Blue Star/LG /Voltas in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, strains complete and checking serviceability of electrical circuit of unit, condenser unit, relays, thermostat, trays including replacement of unserviceable spares such as relays, capacitors, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit. Note: (i) Spares required for replacement on minor repair as mentioned shall be measured and paid as supply only under appropriate item of this schedule and labour charges shall deemed to be included in the quoted rate of this item. (ii) Items required for major repair shall be measured and paid as M&L under appropriate item of this schedule and rate shall be exclusive of quoted rate of this item.
Supply only following company recommended spares as per original of Deep freezer of cap 200/310 Ltr suitable for make- Blue Star/LG /Voltas whichever applicable
Over load protector
Starting relay
Thermostat
Running capacitor 4 to 25 mfd
Sliding trays small as per existing make & model
Sliding trays large as per existing make & model
PVC fan for blower motor
Supply & fix new company sealed reciprocating compressor unit with required nuts, bolts & washers, connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A, replacement of capilary tube and oil filter after dismentling/taking out existing unserviceable/burnt compressor unit from the Deep freezer 200/310 capacity and and testing after completion to entire satisfaction of Engr-in-Charge and user unit suitable for DF Make-Blue Star/LG /Voltas whichever applicable. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of DF. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule. (iii) Company test certificate and warantee certificate shall be submitted to dept.
Supply and fix condenser coil unit of Deep freezer 200/310 Ltr as per existing make and competable model, connecting necessary copper tubings by gas welding, gas charging with R-134 after dismentling/taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge and user unit suitable for DF Make-Blue Star/LG /Voltas whichever applicable. Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule.
M&L for refrigerant gas charging for Deep freezer with R-134A gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquide line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge and User unit for 200/310L deep freezer Unit.
M&L for refrigerant gas charging for Refrigerator with R-134A gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquide line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge and User unit for 190 L to 321 L Refrigerator Unit.
Taking out old unsv and Supply and Fixing Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capacity 2 KVA complete all as specified and directed.
Servicing of window/ split type AC 1.5/2TR TR capacity any make including cleaning the condensing and evaporative coil with the help of descaling solution & water, greasing and oiling the blower motor and refixing the same in position after servicing complete all as specified and directed by Engineer-in-charge.
M&L in replacement of starting relay suitable for 1.5/2 TR capacity window/ split type AC including connections all as specified and directed by Engineer-in-Charge.
M&L in replacement of starting capacitor 80-100 mfd suitable for 1.5/2 TR window/ split type AC all as specified and directed by Engineer-in-Charge.
M&L in replacement of Air Filter pad suitable for window type AC 1.5/2 TR capacity all as specified and directed by Engineer-in-Charge.
M&L in replacement overload protector suitable for 1.5/2 TR window/ split type AC including connections all as specified and directed by Engineer-in-Charge..
M&L in replacement of running capacitor 36/ 45 mfd suitable for 1.5/2 TR capacity window/ split type AC all as specified and directed by Engineer-in-Charge..
M&L for disconnecting and taking down of blower motor suitable for window type AC 1.5/ 2 TR capacity , rewinding with super enameled copper including wire as existing gauge including replacement of bushes and refixing the same complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 74.00 above but suitable for 1.5/ 2 TR capacity spilt type AC.
Supply and charging of R-22/ R-134a as existing refrigerant in window/ split type AC 1.5/2 TR capacity including cleaning the Gas system with anticorrosive solution and charging the refrigerant with anti most substances, strainer and rectification of leakage and replacement of filter and copper capillary complete all as specified and directed by Engineer-in-Charge.
Dismantling of old unserviceable sealed compressor of 1.5/2 TR capacity window type AC and S&F new sealed compressor including soldering of copper pipe, cleaning the refrigerant system, rectification of leakage, charging of refrigerant, rubber pads for foundation, nut & bolts etc and Testing the compressor all as specified and directed by Engineer-in-Charge.
All as per item No.77.00 above but suitable for 1.5/ 2 TR capacity split type AC.
M&L for Painting of bottom tray of window type AC of any capacity with black Japan anti Corrosive paint in side and out side complete all as specified and directed by Engineer-in-Charge.
M&L for Writing of MES No/SM No/Make Srl No on window type AC/Water Cooler/refrigerator/ Deep freezer with white synthetic enamel paid 2” high all as specified and directed by Engineer-in-Charge.
Amount of credit of Rs. 39474.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
Vinod Kumar Aggarwal
Sagar Builders
Vasudeva Trading Co.
Rajesh Agencies
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .