Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical OK |
| 2 | Accepted-Technical | Accepted-Technical OK |
| 3 | Accepted-Technical HOUSE NO 64 VILLAGE PALLA MASTER RISHAL SINGH WALI GALI DELHI NORTH WEST DELHI DELHI 110036 | NORTH DELHI | DELHI | 110036 | Accepted-Technical OK |
| 4 | Accepted-Technical 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | Accepted-Technical OK |
| 5 | Accepted-Technical | Accepted-Technical OK |
Tender Value
Refer Docs
EMD Value
₹19,300
Closing Date
7 Oct 2026, 3:15 pmClosed
EE ENM M 3
DELHI JAL BOARD SECTOR 19 ROHINI
Replacement of damaged electrical panel at Bhagban Apartment Sector 28 Rohini in AC 07
2026_DJB_299312_3
NIT No. 01(2026-27)M-3
Open Tender
Miscellaneous Works
Item Rate
30 days
EE ENM M 3
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No. 50448339804
₹19,300
Yes
12 Oct 2026
1 Oct 2026
7 Oct 2026
1 Oct 2026
7 Oct 2026
1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply / Fabrication of L T Panel Board cubical type, floor mounting, dust & vermin preventing construction, of the minimum size 1650X1700X400mm , suitable for indoor fixing, made out of 16 SWG CRCA sheet (frame of 14 SWG), with provisions for cable entry from bottom and having chambers as- two incomer chambers (one each for the changeover and incomer MCCB), one metering chamber for the main incomer MCCB, four outgoing chambers for the star delta starters for 50 HP motors, , one outgoing chamber for two nos. of lighting MCBs. The panel should have separate cable alleys and bus bar alleys. It should be suitable for operation and maintenance from the front and having removable covers at the back and having doors complete with locks etc. at the front for each chamber. The rating of main bus bars has to be 400 Ampere for three phases and half for the neutral in Aluminium construction duly sleeved with phase indicating heat shrinkable Sleeves. It should be complete in all respect along with painted through powder coating process and with complete provisions suitable for all the switchgears as below to be fitted / installed properly so as to make two incomers, one main metering module, one for lighting supply, four star delta starters with complete mounting accessories as per requirement with complete internal connections of switchgears and control gears with the main bus bars in the Panel through copper cable or bus bars along with Making all the required wiring connections for all measuring and indicating instruments with all the accessories, thimbles, ferrules etc. complete in all respect as per requirement. | 1 | No. | 80 | ₹80 |
| 1.02 | S/o Moulded Case Circuit Breaker (MCCB) of rating 160 Amp, Four Pole, 415V, AC of breaking capacity of 36 KA along with spreader link and rotary handle Make:-L&T/Schneider/BCH/C&S//DJB approved makes | 2 | No. | 80 | ₹160 |
| 1.03 | S/o Moulded Case Circuit Breaker (MCCB) of rating 100 Amp, Triple Pole, 415V, AC of breaking capacity of 36 KA along with spreader link and rotary handle . Make:-L&T/Schneider/BCH/C&S//DJB approved makes | 2 | No. | 80 | ₹160 |
| 1.04 | S/o Moulded Case Circuit Breaker (MCCB) of rating 63 Amp, 4pole, 415 V, AC of breaking capacity of 10 KA or more. Make:-L&T/Schneider/BCH/C&S/DJB approved makes | 2 | No. | 80 | ₹160 |
| 1.05 | Supply / Fabrication of Enclouser Panel for main incoming supply having provision for installation of main 4P MCCB and changeover with Red LEd indication and 3 SP MCBcubical type, floor mounting, dust & vermin preventing construction, of the minimum size 500X400X300mm , suitable for indoor fixing, made out of 16 SWG CRCA sheet (frame of 14 SWG), with provisions for cable entry from bottom. The panel should have separate cable alleys and bus bar alleys. It should be suitable for operation and maintenance from the front and having removable covers at the back and having doors complete with locks etc. at the front for each chamber. The rating of main bus bars has to be 400 Ampere for three phases and half for the neutral in Aluminium construction duly sleeved with phase indicating heat shrinkable Sleeves. It should be complete in all respect along with painted through powder coating process and with complete provisions suitable for all the switchgears as below to be fitted / installed properly | 1 | No. | 80 | ₹80 |
| 1.06 | S/o Enclouser Changeover, Switch, 400 Amp, 4 Pole, 415V AC. Make:-L&T/Schneider/HPL/DJB approved makes | 1 | No. | 80 | ₹80 |
| 1.07 | S/o Moulded Case Circuit Breaker (MCCB) of rating 400 Amp, Four Pole, 415V, AC of breaking capacity of 36 KA along with spreader link and rotary handle Make:-L&T/Schneider/BCH/C&S//DJB approved makes | 1 | No. | 80 | ₹80 |
| 1.08 | S/o Power Contactor, 80 A, TP, 220V / 415V AC
Make:-L&T/Schneider/BCH/C&S/DJB Approved make | 8 | No. | 80 | ₹640 |
| 1.09 | S/o Power Contactor, 70 A, TP, 220V / 415V AC
Make:-L&T/Schneider/BCH/C&S/DJB approved make | 4 | No. | 80 | ₹320 |
| 1.1 | S/o Power Contactor, 25 A, TP NO+NC, 220V / 415V AC Make:-L&T/Schneider/BCH/C&S/DJB approved makes | 2 | No. | 80 | ₹160 |
stage.html
html • 0.03 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_399453.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .