| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L1 | Accepted-AOC DUE L1 RATES | |
| 2 | L2₹25.0 L+₹1.6 L (6.98%)Rejected-Finance PO LEKHAPANI DIST TINSUKIA PIN 786 180 ASSAM | 786180 | L2 | Rejected-Finance DUE TO HIGHER RATE | |
| 3 | L2₹27.6 L+₹4.2 L (18.2%)Rejected-Finance | L2 | Rejected-Finance DUE TO HIGHER RATE | |
| 4 | L4₹29.6 L+₹6.3 L (26.8%)Rejected-Finance LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L4 | Rejected-Finance DUE TO HIGHER RATE | |
| 5 | L5₹32.4 L+₹9.0 L (38.5%)Rejected-Finance | L5 | Rejected-Finance DUE TO HIGHER RATE |
Tender Value
₹27.8 L
EMD Value
₹55,600
Closing Date
3 Sept 2022, 6:00 pmClosed
GE LEKHAPANI
TINSUKIA, ASSAM
PROVISION OF SECURITY LIGHTS,HIGHMAST LIGHTS WITH ALLIED WORKS AND LT UG CABLE WITH PANELS AT CERTAIN AREAS OF MILATARY STATION TEZU AND OUTPOCKETS UNDER GE LEKHAPANI
2022_MES_543522_1
8680/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class D and category b (i)
4 documents required · 4 mandatory
₹500
GE LEKHAPANI
₹55,600
Yes
26 Sept 2022
5 Aug 2022
10 Sept 2022
5 Aug 2022
3 Sept 2022
20 Aug 2022
Amount
S&F Galvanized steel High Mast of 16 Mtrs height lighting system with its accessories including foundation bolts manufactured from special steel and Hot Dip Galvanised along with nuts, washers, anchor plates and templates, feeder pillar panel with single dial timer control and raising & lowering mechanism for integral power tool, Twin aviation Lamp etc. Mast shaft shall be in two sections, hot dip galvanized and suitable for wind velocity as per IS 875 part 3 . It shall also include accessories for high mast including head frame, steel wire rope (7/19 construction) double drum winch, Galvanized Lantern carriage arrangement 'suitable for 08 Nos.luminaires Symmetrically & its control gear boxes and with 03 point suspension system. The mast shall have an integral power tool installed inside the base compartment for its operation. ( Material construction of high mast sheet will be of BSEN 10025 / IS 5986 or equivalent ). with wiring cable for luminaire connection including suitable size ofl foundation for 16.0 mtr high mast considering the soil bearing capacity 10 T / Sq. mtr at 2 meter depth and using M-20 grade design mix concrete with reinforcement,form work,earthwork complete all as per manufacturers instructions and as directed by Eng-in-charge.Note :- (Making of civil foundation for erection of high mast and feeder pillar panel as per manufacturer recommendation should be included in the unit rate ) Make : Surya/Bajaj/Crompton
Supply and fixing LED flood light fittings with and including lamp (minimum 100W rating), separate individual peanut plated Lens housing should be made of LM6 Pressure die Cast Aluminum . Optical cover should be only Toughened Glass only, Impact Resistance >IK05, IP Protection not less than IP 66, Protection should be Class I vibration should be as per IEC 60598, Product Standard IS 10322/IEC 60598, Driver Operating Voltage should be 140 V-270V, Driver Frequency 50Hz, Power Factor>0.9, Lumen output should not be less than 100 Lumen/watt and Luminaries with separate surge protection device 5kA rating and separate connector block for termination of incoming cable connection all as specified and directed. Note :- (i) Earth connection of each light fittings should be connected to system earth point either with 3 core cooper cable or separate earth cable.
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out in soft/loose soil including trimming of sides complete all as specified and directed.
All as per Item No.3 above,but exc.1.5 mtr in depth, not exc 3 mtr in depth complete all as specified and as directed.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer compete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply,laying of sand cushioning with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Note: punned thickness 18cm will be measuered.
Material and labour for brick protection using old size sub class ‘B’ new bricks, laid flat dry but jointed, laid length wise perpendicular to the axis of cable complete all as specified and directed.
M&L for 40mm bore galvanized steel tubing (light grade) with all fittings/clamps, bolts, nuts and washer etc. for cable protection laid in trenches for road crossing/ footpaths etc. complete as specified and directed.
M&L 50 mm dia GI tubing (light grade) with all fittings (ISI Marked) laying in trenches/fixed on pole/wall complete as specified and directed.
M&L Boring holes in the the road by using trenchless technology up to 1 m depth for crossing the road for passing the cable through GI pipe complete all as specified and directed. Note: GI pipe will be measured and paid separately.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core,25.0 sq mm laying in trenches/fixed on pole/wall complete as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3 core,50 sq mm laying in trenches/fixed on pole/wall complete as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core,70 sq mm laying in trenches/fixed on pole/wall complete as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 2 core,10 sq mm laying in trenches/fixed on pole/wall complete as specified and directed.
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising complete with the following items housed in : (FPB near commander office) BUSBAR :- 150 Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance INCOMING:- (i) MCCB 4P of capacity 80 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16KA with thermal magnetic release -01 No (ii) 3 Ph digital volt meter Class 1, 0-500 volts, 3 Phase, 4 digi twith LED display-- 01 No (iii)3 Ph digital Amphere meter Class 1 accuracy , 0.5 VA burdenwith LED display-- 01 No (iv) Modular indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (v) CT (100/5A) -03 Nos OUTGOING:- (i) MCCB 4P of capacity 63 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16KA with thermal magnetic release -02 No (a) MCCB 4 Pole of capacity 40 Amp , breaking capacity 16 KA with thermal release -1 Nos (b) MCB 2 Pole of capacity 6-32 Amp , breaking capacity 10 KA with thermal release -15 Nos
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : (FPB near OJL Living) BUSBAR :- 100 Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance INCOMING:- (i) MCCB 4P of capacity 63 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16KA with thermal magnetic release -01 No (ii) 3 Ph digital volt meter Class 1, 0-500 volts, 3 Phase, 4 digi twith LED display-- 01 No (iii)3 Ph digital Amphere meter Class 1 accuracy , 0.5 VA burdenwith LED display-- 01 No (iv) Modular indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (v) CT (100/5A) -03 Nos OUTGOING:- (i) MCCB 4P of capacity 40Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16KA with thermal magnetic release -02 No (b) MCB 2 Pole of capacity 40 Amp , breaking capacity 10 KA with thermal release -20 Nos
Supply and fixing LED street light fittings with and including lamp (minimum 60W rating), separate individual peanut plated Lens housing should be made of LM6 Pressure die Cast Aluminum . Optical cover should be only Toughened Glass only, Impact Resistance >IK05, IP Protection not less than IP 66, Protection should be Class I vibration should be as per IEC 60598, Product Standard IS 10322/IEC 60598, Driver Operating Voltage should be 140 V-270V, Driver Frequency 50Hz, Power Factor>0.9, Lumen output should not be less than 100 Lumen/watt and Luminaries with separate surge protection device 5kA rating and separate connector block for termination of incoming cable connection all as specified and directed. Note :- (i) Earth connection of each light fittings should be connected to system earth point either with 3 core cooper cable or separate earth cable.
S&F Thermoplastic polycarbonate street light juntion box of size 155x210x92mm which is totally safe, shock proof, impact resistant, weather proof, dust proof, rust proof ,halogen and slica free, having internal embedded gasket technology made of PUR (Make Hensel), complete with IP 66 degree of protection with cable glands (Make AGRO) material polymide in and including the following :- Junction box Cat No DK-1610G (box with 5 way Hensel terminal) and having metric knock out on 2 sides ) - 02 Nos,cable gland, Lock nut - 02 Nos, MCB SP, 6 Amps - 01 Nos
Supply,erecting and fixing steel tubular swaged pole 8.50 mtr long type 410 SP-22 confirming to IS - 2713 Prt I to III 1980 with and including cast iron base plate, finial taper plug, Nuts, bolts and washers etc and fixed into plain cement concrete foundation duly painted with two coats of aluminium paint over coat of red oxide primer including preparation of surfaces and making strip 150 mm wide up to 1.50 Mtr (above PCC coping ) by black, yellow, paint in alternate layer and pole numbers complete all as specified and directed by Engr-in-Charge. Note : Earth work, cement concrete will be measured and paid separetely.
S&F Bracket for street light fittings made out of 40 mm dia "medium grade" galvanized steel (GI) tubing of 1.5 m long, bent to required shape (having an angle 120 degree) including necessary FI clamp (02 Nos of size 40 x 5 mm) nuts, bolts and washers and fixing to the pole complete after taking down old unserviceable bracket from the pole complete all as specified and directed.
M & L PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation of poles, stay assembly, struts, etc. including necessary formwork complete all as specified and directed.
M & L PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in coping of poles including necessary formwork complete all as specified and directed.
S&F Weather proof PVC insulated copper conductor cable 1.5 sqmm 3 core duly inserting the cable inside the pole including making hole if required on top and bottom of the steel pole complete all as specified and directed.
S&F Street light panel provided with protection degree IP 54 including digital timer , contractor rating 32 A TP and 40A MCB SPN -01 Nos, in built short circuit protection with complete fixing arragement on pole by providing Clamp of size 25X3mm and nut bolts complete all as specified and directed by Engr-in-Charge
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR Part -I connected to earthing test point all as specified complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia GI pipe (medium grade) ISI marked watering pipe with GI funnel with wire mesh 40mm bore GI pipe (medium grade) ISI marked for protection of earth lead conductor and testing on completion complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 in SSR Part -I connected to earthing test point all as specified complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia GI pipe (medium grade) ISI marked watering pipe with GI funnel with wire mesh 40mm bore GI pipe (medium grade) ISI marked for protection of earth lead conductor and testing on completion complete all as specified and directed.
RIA CONSTRUCTION
FEBI CONSTRUCTION
M/S A K BROTHERS
satyabhama and co
MAZUMDAR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .