EXECUTIVE ENGINEER
D W AND S MECH DIV HZB
Quotations through etender are invited for rates of items materials annexed as Annexure 1 for framing estimate of Supply, Installation and commissioning of Pump set Stablizer Works from Reputed Manufacturers authorized dealers having valid GST
2026_DWSD_112373_1
01 DWSD/HZB/MECH/QUOTATION 2026
Open Tender
Pumps/Motors
Item Rate
HAZARIBAG
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
18 Apr 2026
10 Apr 2026
18 Apr 2026
10 Apr 2026
17 Apr 2026
10 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Cost towards Supplying, Installation, testing and commissioning of Servo Controlled Automatic Voltage stabiliser suitable for out put voltage of 415 Volt +/-1%, Input 240 to 460 Volt .
3 Ph, 50 Hz, with copper wound transformer (air/oil cooled) as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and user's controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttons etc. Suitable capacity termination strips and bus bars for incoming and out going cables, earthing with change over switch should be provided. All three phases shall be independently monitored and corrected. Following protections and indications shall be incorporated.1.Over Voltage / Under Voltage,2.Single Phasing,3.Cut off contactor with electronic output sensing unit. 1. 200 KVA | - | JOB | - | - |
| 1.02 | Cost towards Supplying, Installation, testing and commissioning of Servo Controlled Automatic Voltage stabiliser suitable for out put voltage of 415 Volt +/-1%, Input 240 to 460 Volt .
3 Ph, 50 Hz, with copper wound transformer (air/oil cooled) as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and user's controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttons etc. Suitable capacity termination strips and bus bars for incoming and out going cables, earthing with change over switch should be provided. All three phases shall be independently monitored and corrected. Following protections and indications shall be incorporated.1.Over Voltage / Under Voltage,2.Single Phasing,3.Cut off contactor with electronic output sensing unit. 2. 300 KVA | - | JOB | - | - |
| 1.03 | Cost towards Supplying, Installation, testing and commissioning of water lubricated vertical turbine pump sets Make Mather & plate/ Kirloskar/ Jyoti/ WPIL with heavy duty M.S column assembly coupled with vertical hollow shaft sq. cage induction motor make KIRLOSKAR / JYOTI /CROMPTON/ABB operated on 415±10% volts, 50 Hz 1480 RPM with sole plate, discharge head, S.S. socket, spider bearing, sluice valve-1 no. NR valve – 1 no., pressure gauge – 1 no. etc all complete. 1. Capable of Discharging 20000 GPH/90 m3/hr at a head of 81 Mtrs | - | JOB | - | - |
| 1.04 | Cost towards Supplying, Installation, testing and commissioning of water lubricated vertical turbine pump sets Make Mather & plate/ Kirloskar/ Jyoti/ WPIL with heavy duty M.S column assembly coupled with vertical hollow shaft sq. cage induction motor make KIRLOSKAR / JYOTI /CROMPTON/ABB operated on 415±10% volts, 50 Hz 1480 RPM with sole plate, discharge head, S.S. socket, spider bearing, sluice valve-1 no. NR valve – 1 no., pressure gauge – 1 no. etc all complete. 2.Capable of Discharging 60000 GPH at a head of 34 Mtrs | - | JOB | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
TC.pdf
Tender Documents • 0.19 MB
BOQ_151727.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .