Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | ₹8.8 L Quoted ₹8.9 L | L1 | Accepted-AOC AOC |
| 2 | L2₹9.0 L+₹11,596.50 (1.31%)Rejected-Finance | ₹9.0 L+₹11,596.50 (1.31%) | L2 | Rejected-Finance REJECTED DUE TO NOT LOWEST |
| 3 | L3₹9.6 L+₹71,465 (8.05%)Rejected-Finance PO LEKHAPANI DIST TINSUKIA PIN 786 180 ASSAM | 786180 | ₹9.6 L+₹71,465 (8.05%) | L3 | Rejected-Finance REJECTED DUE TO NOT LOWEST |
| 4 | L4₹9.7 L+₹83,230 (9.38%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | ₹9.7 L+₹83,230 (9.38%) | L4 | Rejected-Finance REJECTED DUE TO NOT LOWEST |
| 5 | L5₹10.5 L+₹1.7 L (18.8%)Rejected-Finance | ₹10.5 L+₹1.7 L (18.8%) | L5 | Rejected-Finance REJECTED DUE TO NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
3 Jun 2021, 6:00 pmClosed
GE LEKHAPANI
GE LEKHAPANI, TINSUKIA, ASSAM
REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION WORKS FOR ZONE-II,III AND VI AT LEKHAPANI MILITARY STATION UNDER GE LEKHAPANI
2021_MES_440801_1
8600/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class E Cat b (i)
4 documents required · 4 mandatory
₹500
GE LEKHAPANI
₹19,000
Yes
15 Jul 2021
6 May 2021
5 Jun 2021
6 May 2021
3 Jun 2021
20 May 2021
Amount
Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge
Material and labour for providing point wiring for controlled by one switch with using 1.50 sq.mm (nominal area), stranded copper conductor, single core PVC insulated flame retardant unsheathed cable (Maintaining Colour Code) 1100 volts grade with and including PVC casing and capping (size of casing caping as required at site but not less than 20mm) of suitable size including PVC accessories / fittings and fixtures fixed on surface with using new PVC board or sunken type pressed steel box of adequate size, terminal boxes for mounting fittings/junction boxes with and including all accessories and using 1.5 sq.mm (nominal area), stranded copper conductor, single core PVC insulated flame retardant unsheathed cable green in colour as in earth continuity conductor connected to common earth dolly and connecting upto fittings complete all as specified and directed. NOTE: The quoted rates shall be inclusive for fixing casing caping to surface with using PVC raw plugs and provision of PVC boards/terminal/junction boxes of any shape and size. (a) One light point controlled by one, one way switch
(b) One fan point controlled by one, one way switch
(c) One socket outlet 3 Pin, 6 Amp on independent board
(d) One socket outlet 3 Pin, 6 Amp on same board.
(e) One bell point controlled by one bell push
Material and labour for providing point wiring by using cable of size 2.5 sq.mm (nominal area) single core PVC insulated flame retardant un-sheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade with and including PVC casing capping as required at site but not less than 20 mm including suitable accessories and fittings/fixtures and PVC box as required at site for mounting switches, sockets, etc. for one socket outlet 3/6 pin 15 amps including 2.5 Sq.mm PVC insulated unsheathed multi-stranded flame retardant copper conductor cable green in colour for earth continuity & connected to common earth dolly complete all as specified & directed.
Material and labour for providing point wiring for controlled by one switch with using 1.50 sq.mm (nominal area), stranded copper conductor, FRLS single core PVC insulated flame retardant unsheathed cable (Maintaining Colour Code) 1100 volts grade with and including rigid PVC conduit (size of conduit as required at site but not less than 20mm) of suitable size including PVC accessories / fittings and fixtures concealed in wall with using new sunken type pressed steel box of adequate size, terminal boxes for mounting fittings/junction boxes with and including all accessories and using 1.5 sq.mm (nominal area), stranded copper conductor, single core PVC insulated FRLS unsheathed cable green in colour as in earth continuity conductor connected to common earth dolly and connecting upto fittings complete all as specified and directed. NOTE: The quoted rates shall be inclusive for cutting chases on wall and making good incl colour wash complete. (a) One light point controlled by one, one way switch
(b) One fan point controlled by one, one way switch
(c) One socket outlet 3 Pin, 6 Amp on independent board
(d) One socket outlet 3 Pin, 6 Amp on same board.
(e) One bell point controlled by one bell push
Material and labour for providing point wiring by using cable of size 2.5 sq.mm (nominal area) single core PVC insulated FRLS un-sheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade with and including PVC conduit as required at site but not less than 20 mm including suitable accessories and fittings/fixtures and pressed steel sunken box box as required at site for mounting switches, sockets, etc. for one socket outlet 3/6 pin 15 amps including 2.5 Sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable green in colour for earth continuity & connected to common earth dolly complete all as specified & directed.
S&F for switch paino flush type 5 Amps single pole one way 230 volts AC circuit complete all as specified and directed.
S&F for bell push flush type 5 Amps single pole 230 Volts AC Circuit complete all as specified and directed.
S&F call bell AC 230 Volts single pole complete all as specified and directed.
S&F for socket outlet 2 in 1 3 pin 5 Amps flush type 230 volts AC circuit on same board complete all as specified and directed.
S&F switch socket combination 2 in 1 3/5 pin 5/6 Amps 240 volts flush type multipurpose complete all as specified and as directed.
S&F switch socket combination 2 in 1 5/6 pin 5/6 Amps and 15/16 Amps flush type 240 Volts universal complete all as specified and as directed.
Supply and fix Electronic fan regulator 230 volts , step type,socket type ,hum free 120 watt ISI Marked,including taking down unserviceable. Make Legrand/Anchor/SSK
M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate, isolated body (ISI Marked)
Supply & fixing PVC poly carbonate round blocks 10 cm dia.
Supply & fix modular switch one way 6 Amps 1 module
Supply & fix modular socket outlet,5 pin 6 Amps flush type 2 module.
Supply & fix modular switch one way 16 Amps 1 module
Supply & fix modular socket outlet,5 pin 16 Amps flush type 2 module.
Supply & fixing modular ceiling fan regulator,electronic type,step type 5 speed A/C, 230 volts all as directed by Engineer-in-Charge
Supply & fix modular bell bush flush type 5 Amps
Supply & fix modular blank plate 1 module
S & F Modular type White cover plate with frame 3 module
S & F Modular type White cover plate with frame 4 module
S & F Modular type White cover plate with frame 6 module
S & F Modular type White cover plate with frame 2 module
S & F Modular type Metal Flush box 3 module
S & F Modular type Metal Flush box 4 module
S & F Modular type Metal Flush box 6 module
S & F Modular type Metal Flush box 1/2 module
M&L for providing sub main wiring with two single core 6.00 Sqmm (nominal area) PVC Insulated flame retardant unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC casing-capping complete including 6.00 Sqmm PVC insulated unsheathed multi stranded flame retardant single core copper conductor cable for earth wire including taking down/removing old one and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) Two runs of single core 6.00 Sqmm multi stranded copper cable and one run of 6.00 Sqmm earth wire and one run of casing caping shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the casing capping.
M&L for providing sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated flame retardant unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC casing-capping complete including 4 Sqmm PVC insulated unsheathed multi stranded flame retardant single core copper conductor cable for earth wire including taking down/removing old one and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) Two runs of single core 4.00 Sqmm multi stranded copper cable and one run of 4 Sqmm earth wire and one run of casing caping shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the casing capping.
S&F PVC/polycarbonate Angular lamp Holder insulated body with back plate angle type suitable for batten complete all as specified and directed by Engr-in-charge .
S&F LED Blub 10 watt Self Ballasted Retrofit type lamp with PBT body shell and DC Diffuser CCT 6500 K with fitting complete all as specified and directed.
Supply and fixing LED Tube light fitting 18 watt 4 feet pre coated CRCA body heavy duty Industrial Batten suitable for Retrofit LED Tube 18watt including LED tube rod 20 watt self ballasted retrofit lamps with thermoplastic body 270 degree wide distribution CCT 6500 K including fitting fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of size 23/0.0076 including taking down old unsv tube light fitting and making necessary connection complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures etc complete from existing main boards and removing from site all complete all as directed.
Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral link complete all as directed by Engineer-in-Charge.
Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 4 way (2 + 2 way) single pole and neutral link complete all as directed by Engineer-in-Charge.
Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 4 way triple pole and neutral link complete all as directed by Engineer-in-Charge.
Supply and fix MCB single pole and neutral (SP&N) 25 to 32 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable one complete all as specified and directed.
S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA 'B' series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete all as specified & directed by Engineer-in-Charge.
Taking down old unserviceable bulk head and supply and fix 10 watt LED Bulk head fitting in engineering plastic housing with clear prismatic diffuser. Make : Crompton or equivalent in Havells/Syska/Philips/Bajaj complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable Switch fuse unit and supply and fixing switch fuse unit 32 Amp single pole and neutral switch fuse unit with rewirable porcelein fuse unit with side handle and in sheet inclosure all as directed by Engr-in-Charge.
S & F Aesthetically designed 1x1 LED light 18 W flat panel square type for ceiling mounting which provides soft-light and glare free symmetrical illumination.
S & F LED building security light fitting 25W new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOPOPENINg seperate driver compartment with IP65 protection and impact resistance of IK07.
S&F IN REPAIR S&F only in repair by taking out the unserviceable/burnt Bell push, flush type, 5 amps, 230V AC,single pole, one way (Make:Anchor/Leader/Plaza)
S&F only in repair by taking out the unserviceable/burnt switch piano flush type, 5 amps, 230V AC,single pole, one way (Make:Anchor/Leader/Plaza)
S&F only in repair by taking out the unserviceable/burnt switch piano flush type, 5 amps, 230V AC,single pole, two way (Make:Anchor/Leader/Plaza)
S&F only in repair by taking out the unserviceable/burnt switch socket combination multipurpose suitable for 2 pin and 3 pin 5 amp flush type (Make:Anchor/Leader/Plaza)
S&F only in repair by taking out the unserviceable/burnt switch socket combination multipurpose suitable for 2 pin and 3 pin 6 and 15 amp flush type (Make:Anchor/Leader/Plaza)
S&F only in repair by taking out the unserviceable/broken angle type holder insulated body in white colour with back plate suitable for batten fittings (Make : Anchor/Leader/Plaza)
S&F only in repair by taking out the unserviceable fan capacitor 2.5 mfd, 415 volts suitable for ceiling fans all as specified and directed. (Make-Havells/Usha/Epcos)
S&F only in repair by taking out the unserviceable fan capacitor 4 mfd, 415 volts suitable for Exhaust fans all as specified and directed. (Make-Havells/Usha/Epcos)
S&F only in repair by taking out the unserviceable fan regulator 300 watt, 230 volts suitable to control ceiling fans all as specified and directed (Make-Havells/Crompton/Anchor)
S&F only in repair by taking out the unserviceable/burnt electric call bell, AC, 230 V, single pole (Make : Leader/Anchor/Plaza)
Supply & fix in repair PVC insulated flexible cable three core copper conductor of size 1.5 sqmm (size 48/0.20mm) each, ISI marked, covered with round insulation complete (Make : Polycab/Klick/Plaza)
Supply & fix in repair PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 volt grade complete for the following sizes :- (a) 1.5 sqmm size
(b) 2.5 sqmm size
(c) 4 sqmm size
(d) 6 sqmm size
S&F in repair PVC rigid rectangular blocks, with back plate complete of the following sizes:- (a) 10x10x4.5 cm depth
(b) 17.5x9.5x4.5 cm
(c) 24.5x19.5x4.5 cm depth
S&F in repair PVC flexible wire, twin core twisted of size 28/0.0048 mm copper conductor, multistranded, ISI marked complete. (Make :Klick/Plaza/Polycab)
S&F in repair MCB single pole and neutral (SP&N) 25 to 32 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs all as specified and directed.
S&F in repair MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA 'B' series with all incoming/outgoing connection with proper size lugs all as specified and directed.
ADNEEDS ENTERPRISE
RIA CONSTRUCTION
MAA COMMUNICATION
RC CONSTRUCTION
ms singh construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .