Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.4 L+₹3.9 L (16.5%)Rejected-Finance 119 LANE NO 4 DAYA NAND NAGAR LAWRENCE ROAD AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L2 | Rejected-Finance Quoted amount is more than L1 | |
| 3 | L3₹29.5 L+₹5.9 L (25.2%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L3 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Jun 2024, 6:00 pmClosed
Shri Sahil Ratusaria, IDSE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REPAIR/ MAINT OF TO REFRIGERATION AND AIR CONDITIONING EQUIPMENTS WATER COOLER INSTALLED AT MH NAMKUM AND VARIOUS UNITS AT NAMKUM KHOJATOLI AND LPH AREA UNDER GE RANCHI
2024_MES_655146_1
8400/1220/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Ranchi, 7th Club Road Ranchi, PI
Class D Cat c (i)
6 documents required · 6 mandatory
₹500
Yes
GE Ranchi
₹50,000
Yes
2 Sept 2024
21 May 2024
17 Jun 2024
22 May 2024
15 Jun 2024
3 Jun 2024
Amount
Taking out split type air conditioners indoor and out door units complete for repair/ servicing and overhauling of capacity 1.5/2.0 TR of any make/type after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower etc and also connecting of refrigerant pipe, drain pipe and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed. Note :- (i) Spares will be measured and paid separately (ii) Refrigerant gas will be measured and paid separately.
M&L hermetically sealed compressor of split type air conditioner of 1.5 TR capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make : Voltas/Hitachi/Tecumseh/Kirloskar/LG/Blue Star Note: The compressor of split type air conditioner shall be suitable for any type of AC (i.e. inverter AC/Normal AC) and cost to be includes in quoted rates of items.
All as per item No 02 above here-in-before but 2.0 TR.
Supply and fix MS wall bracket suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed.
M&L leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering,flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in split type air conditioner upto 2 TR capacity and testing complete all as specified and directed Note:- Refrigerant will be measured and paid separately.
Supply and charging refrigerant gas (R-134a ) suitable for Refrigerators/water coolers and Deep freezers complete all as specified and directed. Make: Mafron or equivalent makes as approved by the GE. Note :- Charging of refrigerant shall be measured and paid separately
Supply and charging refrigerant gas (R-22 ) suitable for split type AC complete all as specified and directed. Make: Mafron or equivalent makes as approved by the GE. Note :- Charging of refrigerant shall be measured and paid separately
Supply only relay assembly suitable for split type air conditioner 1.5/2.0 TR capacity complete all as specified and directed.
Supply only fan motor with blade suitable for out door unit of split type air conditioner up to 2 TR capacity complete all as specified and directed.
Supply only contactor suitable for split type air condtioners upto 2 ton capacity complete all as specified and directed. LG/Samsung/Carrier/Blue star/Hitachi
Taking down the unserviceable IDU blower motor and supply and fix IDU blower motor capacity as per existing make all as directed for 1.5 / 2 TR split AC.
Supply only starting capacitor 80 to 100 mfd for split type air conditioners complete all as specified and directed. Make : Concap/Keltron/Asian/Tesla/sarda/ Siemens/Tibcon
Supply only running capacitor 50 -60 mfd for split type air conditioners complete all as specified and directed. Make : Concap/ Keltron/Asian /Tesla/ sarda/ Siemens / Tibcon
Supply only universal strainer air filters cum dryer suitable for Split Air conditioners of capacity up to 2 TR complete all as specified and directed.
Taking down sensor unit PCB board from indoor unit of split type AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed. Note: Cost of sensor unit PCB board for indoor unit of inverter split type AC/Normal AC of 1.5/2.0 TR capacity to be includes in quoted rates of item.
Removing the old unserviceable swing motor of any type and supply and fix new swing motor of 1.5/2.0 TR capacity split type ACs complete all as specified and directed.
Taking down perished unserviceable insulation cover of refrigerent piping and supply and fix thermo rexine tape including brutile rubber insulation for refrigerent pipings of suitable size.
Material and labour for 20 mm Low density polyethylene pipes (LDPE) of pressure 6kgf/sqcm fixed complete on walls, ceilings including all accessories complete. (Drain pipe )
Taking out the old unserviceable capillary tube 0.064 inch and supply and fix new capillary tube with strainer for the split type ACs 1.5/2 TR capacity complete all as specified and directed.
Disconnecting and taking out the old unserviceable copper tubing and supply and fix copper tube of size 3/8"/5/8"/1/4"/1/2" dia including necessary soldering, flaring work and jointing testing complete all as directed
Removing the old unserviceable copper cable after disconnecting electrical connections and supply and fix PVC insulated, sheathed , multistandard,1100 volts grade copper conductor cable of size 2.5 sqmm;3 core complete all as specified and directed.
Supply only new hand remote control of existing make suitable for 1.5/2 TR split type AC including 2 Nos batteries of suitable size and testing complete all as specified and directed
Dismantling indoor and outdoor units of split type air conditioner of any capacity after pumping down the gas,disconnecting electric connections without any damage to existing system, reinstalling of indoor and outdoor units in new locations complete with brackets and civil works (making holes in wall) as required, assembling of indoor & outdoor units including connection of suction and discharge pipes and testing etc with topping up refrigerant gas as required to maintain the pressure complete all as specified and directed.
S & F metal clad socket 20 Amps, AC, 230 volts in replacement of old u/s metal clad socket complete.
S & F metal clad plug 20 Amps, AC, 230 volts in replacement of old u/s metal clad plug complete.
S & F in repairs Single pole and neutral enclosure with a two pin and earth plug & socket with one sigle pole MCB 20 Amps, fixed to wall and making all connections all as directed. Make Havells / Legrand / Indo Asian
Taking down old MCB SP and Supply and fixing MCB SP 6 - 32 Amps rating, 'C' series , 10 KA breaking capacity, 240 V, 50 Hz AC supply including making all connections complete all as specified . Note :- Make : Indo Asian/ Havells / Legrand .
Removing old unserviceable condenser coil assembly from split type air conditioner upto 2 TR capacity supply and fix copper condenser coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
Removing old unserviceable cooling coil assembly from split type air conditioner upto 2 TR capacity supply and fix copper cooling coil assembly with all accessories suitable to existing make/type and testing complete all as specified and directed.
Removing old unserviceable 2-3 way refrigerant control valve from split air conditioner outdoor unit after evacuating of refrigrant gas and supply and fix 2-3 way valve suitable for split type ACs of capacity upto 2 TR and testing complete all as specified and directed.
Removing old unserviceable split type air conditioner indoor unit and deposited in store yard for safe custody and Supply and fix indoor unit of the split type air conditioner 1.5/2 TR capacity and complete with all accessories such as installation plate with screws, blower motor, swing motor, filters etc duly prewired and including connecting of existing refrigerant piping, electrical connections, drain pipe and testing etc complete all as specified and directed.Make: Carrier/LG/Blue star/Voltas.
Removing old unserviceable split type air conditioner indoor unit and deposited in store yard for safe custody and Supply and fix indoor unit of the split type air conditioner 2 TR capacity, complete with all accessories such as installation plate with screws, blower motor, swing motor, filter etc duly prewired and including connecting of existing refrigerant piping, electrical connections, drain pipe and testing etc complete all as specified and directed. Make: Carrier/LG/Blue star/Voltas.
Removing old unserviceable split type air conditioner outdoor unit and deposited in store yard for safe custody and Supply and fix outdoor unit of the split type air conditioner 1.5 TR capacity, complete with all accessories such as hermetically sealed compressor and condensor unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refirgerant gas piping, electrical connections and testing etc complete all as specified and directed. Make: Carrier/LG/Blue star/Voltas.
Removing old unserviceable split type air conditioner outdoor unit and deposited in store yard for safe custody and Supply and fix outdoor unit of the split type air conditioner 2 TR capacity, complete with all accessories such as hermetically sealed compressor and condensor unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refirgerant gas piping, electrical connections and testing etc complete all as specified and directed. Make: Carrier/LG/Blue star/Voltas.
Supply only capacitor 2.5 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos/Universal/Tipcon
Supply only capacitor 4 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos/Universal/Tipcon
Supply only capacitor 6 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos/Universal/Tipcon
Servicing the Voltage Stabilizer 4 KVA/5 KVA single phase after replacing transformer, PCB,u/s electronic parts,setting/testing of buck/boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Taking out water cooler for servicing and leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing of 40 ltr to 150 ltr capacity of any make/type after disconnecting of electric connection, removing dust by using blower and cleaning all the components by using water and caustic soda, checking and replacing the spares like relay, capacitors,gasket, thermostat, PVC pipes, push cock/liftcock, float valves etc and charging of refrigerant gas if required including testing and fixing back in its original location complete all as specified and directed.
Replacing the corroded portion of the water cooler 40 ltr to 150 ltr capacity of any type/ make and providing the same gauge sheet in corroded portion by bending/welding, soldering and also providing base support legs complete all as specified and directed.
Material and labour for spray painting to water coolers upto 150 ltr capacity of any type /make with two coats of synthetic enamel paint over one coat of red oxide primer after removal of existing treatment and preparation of surfaces and including removing dents complete all as specified and directed.
Supply and fix hermetically sealed compressor for water cooler 40/80 litres capacity including initial filling of refrigerant gas to the required pressure and testing, also including removing the old unserviceable compressor complete all as specified and directed. Make: Voltas/Blue Star/Tecumseh/Kirloskar/Usha
All as per item No 42 above but for 120/150 litre capacity.
Supply only capacitor 10-20 mfd complete all as specified and directed. Make: Asian/ KEL/Epcos
M & L for PVC drain hose pipe size 32mm dia LDPE waste hose pipe fitted to water cooler all as specified and as directed.
M & L for PVC hose connection pipe 300 mm length both ends having brass coupling threaded for 15mm GI tubing of standard length.
Supply and laying of GI tubing medium grade 15 mm bore laid on floor/wall including all fittings such as bend,tea, union, elbow etc all direcdted as specified.
Supply and fix stop valve 15 mm dia, cast copper alloy chromium plated high pressure with crutch or butterfly handle screwed both ends for GI pipe/fittings inlcuding removing old unserviceable item complete all as specified and directed. Make : Prayag/Essco/Polytuff
Supply and fix push button tap, 15 mm dia, cast copper alloy chromium plated high pressure screwed for GI pipe/fittings inlcuding removing old unserviceable item complete all as specified and directed. Make : Prayag/Essco/Polytuff
Cutting exisiting steel tubing / PVC pipe for alterations or additions for 25/32mm all as specified.
Supply and fix in repair float valve / ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of size 15 mm bore suitable for water cooler complete all as specified and directed. Make : Prayag/Essco/Polytuff
Removing old unserviceable condenser coil assembly from water cooler any type supply and fix copper condenser coil assembly with all accessories suitable for water cooler of capacity up to 150 ltrs and testing complete all as specified and directed.
Supply only fan motor with blade ,single phase, 230V,50Hz for water coolers up to 150 Ltrs capacity complete all as specified and directed. Make : Usha/ AUE /Siemens/Keltron or equivalent any make with ISI marked.
Supply only relay assembly suitable for water coolers capacity complete all as specified and directed.
Supply only thermostat switch for water coolers any type/ make complete all as specified and directed. Make: INDOFOSS/ RANUTRAL/AUE/Danfos
Supply and fix 15/16 Amps, three pin plug top,230 V,AC complete all as specified and directed
Taking out Refrigerator for servicing and overhauling of capacity up to 345 ltr (single door/Double door type) of any make/type after disconnecting of electric connection and cleaning all the components, checking and replacing the spare parts like relay, capacitors, thermostat,fused bulb and also including carrying out servicing, oiling, greasing and charging of refrigerant gas and testing complete all as specified and directed. Note :- (i) Spares will be measured and paid separately as supply only. (ii) Refrigerant gas will be measured and paid separately as supply only.
Supply and fix hermetically sealed compressor of Refrigerator up to 180 litres capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. Make: Voltas/Kelvinator/Tecumseh/Kirloskar/Usha/ Godrej
All as per item No 58 above but for Refrigerator up to 345 litres capacity.
Supply only relay assembly suitable for refrigerators of any type/ capacity up to 345 litres complete all as specified and directed. Make : Sarda/Annapurna/LG/Videocon/Whirlpool Note: Cost of relay assembly suitable for refrigerators of inverter type/Normal of capacity up to 345 liters to be includes in quoted rates of item.
Supply only bi-metal switch for refrigerators of any type/ capacity up to 345 litres complete all as specified and directed. Make:- LG/samsung/Videocon/Godrej/ Whirlpool
Supply only condensor coil suitable for refrigerators of any type/ capacity up to 345 litres complete all as specified and directed.
Supply only cooling coil suitable for refrigerators of any type/ capacity up to 345 litres complete all as specified and directed.
Supply only fan motor with blade suitable for refrigerators of any type/ capacity up to 345 litres complete all as specified and directed. Make : Samsung/Godrej/LG/Videocon/Whirlpool
Supply only thermostat switch for refrigerators of any capacity/ any type/ make complete all as specified and directed. Make: INDOFOSS/ RANUTRAL/Annapurna Note: Cost of thermostat switch for refrigerators of inverter type/Normal of capacity up to 345 liters to be includes in quoted rates of item. .
Removing old unserviceable capilary copper tube of size 0.031" (Inch) and supply and fix new capilary copper tube suitable for existing type/make/size complete all as specified and directed.
M & L acrylic plastic chiller tray's such as suitable for Vegitable,side fixing tray's,ice cube tray's etc.,complete all as specified and directed.
Removing old unserviceable bulb from refrigerator and supply & fix new bulb suitable for existing type/make/capacity/size complete all as specified and directed
Taking down old unserviceable PCB board with electronic circuit from refrigerator of any capacity/type and supply & fix new PCB board including electronic circuit complete all as specified and directed.
Taking out deep freezers to workshop for servicing of capacity up to 500 Ltr of any make and any type by replacing unserviceable compressor and other parts from the machine as directed including charging of Refrigerant gas after vacumising and making system leak proof by leak testing with dry nitrogen,brazing the suction / discharge tubes where required,cleaning of condensing unit to achieve proper cooling effect,checking of electronic circuit of machine and service where necessary by replacing electronic parts and replacing the wirings with proper size of PVC insulated wires complete all as directed and testing complete.
Supply only Thermostatic switch suitable for Deep freezer of capacity up to 500 Ltr (Make : Indfos/ Denfoss/ Ranutal/Annapurna
Supply only Relay suitable for Deep freezer of capacity up to 500 Ltr.
Supply and fix Fan Motor with blade, single phase,230V AC 50 Hz for Deep Freezer of any make and capacity up to 500 Ltr.
Supply and fix hermetically sealed compressor for deep freezer up to 500 Ltr capacity including initial filling of refrigerant gas to the required pressure and testing, also including removing the old unserviceable compressor complete all as specified and directed. Make: Voltas/Blue Star/Tecumseh/Kirloskar/Usha
Supply and fixing sub main wiring with two single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 4 sqmm drawing in & including medium grade PVC concealed conduit pipe 20mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additonal earth wire of 4.0 sq mm but green in colour for earth DBs and boxes with proper thimbles connecting up and taking down old submain wiring complete all as specified and directed (Note : Two run of wire and one run of earth wire drown in PVC conduit of 20mm dia shall be measured as one RM)
india trading company
Raj Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .