Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l-1₹17.9 LAccepted-AOC | l-1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | l-2₹18.3 L+₹41,017.50 (2.29%)Rejected-Finance | l-2 | Rejected-Finance Higher side quoted amount | |
| 3 | l-3₹22.5 L+₹4.5 L (25.3%)Rejected-Finance H NO 89 BEHIND DD LEH UT LADAKH | LEH | LEH | LADAKH | 194101 | l-3 | Rejected-Finance Higher side quoted amount | |
| 4 | Rejected-Technical SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | - | Rejected-Technical Due not enlisted in appropriate category. | |
| 5 | Rejected-Technical HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | - | Rejected-Technical Due not enlisted in appropriate category. |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
11 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
CWE Khumbathang
REPAIR/REPLACEMENT OF TRANSFORMERS, LT CABLES AND OTHER ALLIED WORKS AT BATALIK IN THE AOR OF AGE B/R-II KHALTSI UNDER GE KHUMBATHANG
2023_MES_585840_1
80051/158/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Batalik
As per tender and NIT doc
8 documents required · 8 mandatory
₹500
GE Khumbathang
₹50,000
3 May 2023
15 Mar 2023
12 Apr 2023
15 Mar 2023
11 Apr 2023
29 Mar 2023
Amount
Labour only for installation of copper wound transformer step up/ step down, indoor/outdoor type in two pole structure complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity 250 KVA. complete all as specified and as directed by Engr-in-charge. Note:- Transformer will be issued under Schedule 'B' from store of AGE BR-II Khaltsi Store Yard.
Dismantling & Taking Out HT 11 KV, (GoD)out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators of rating upto 200 Amps directed by Engr-in-charge.
Supply & erect 2 pole structure on 11 meter steel tubular pole SP-55 consisting of pole with anti-climbing device, including PCC foundation of 1:3:6 & cross arms etc for one incoming and one out going,with 2 coat silver animal colour paint as directed by Engr-in-charge.
Supply and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular 10 sqmm complete all as specified and directed by Engr-in-charge
Supply and laying in replacement of XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size10 Sq mm 2 core complete Trenches/ ducts all as directed .
laying & connecting only XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 50 to 95 Sqmm 4 core complete all as specified Note:-Cable will be issued under schdule 'B' free for laying from store of AGE BR-II Khaltsi Store Yard.
Excavation in trenches, getting out in hard/dense soil not exceeding 1.5m deep and not exc 1.5m wide for taking out the existing cable of poles etc any size at places complete all as specified and directed in hard & dense soil.
Removing of surplus soil to a distance not exceeding 50 mtr complete all as specified and deposited where directed at a level not exceeding 1.5m above the starting point all as specified.
Returning filing in including spreading levelling, watering & well ramming in layers not exceeding 25 Cm thick all as specified.
Material & Labour for sand cushioning 15 cm below and 8 cm above the U/G cable laid (total depth of send shall be 23 cm) complete all as specified & directed by Engr-in-Charge. Note:-Punned thickness will be measured and paid.
M&L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site.
S&F in repair Gapless surger Arrestor ,9KV,10KA,LA with polymer housing station type,directed by Engr-in-charge.
S&F in repair 11 KV GO,AB Switch3-phase,3-pole ,200 Amps vertical type,directed by Engr-in-charge.
S&F in repair 11 KV horn gap Fuse set 3 phase 200 Amp,directed by Engr-in-charge.
Supply, laying and testing in repair XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed of size 3 core 120 Sqmm complete all as specified and directed by Engr-in-Charge.
S&F in repair 33/36 KV Polymeric Composite disk insulator ,Min failing load 70N Lighting Impluse 170 KV Positive and 180 KV Negative distance 900 mm,directed by Engr-in-charge.
S&F in repair 33/36KV polymeric composit pin insulators ,10KN,lighting Impluse 170KV positive and 180KV Negative creepage distance 900mm.directed by Engr-in-charge.
S&F in repair LTDE box for 100KVA with 100 Amp, 36KA, 4 Pole MCCB for incoming and outgoing line.directed by Engr-in-charge.
S&F in repair Wedge connectors /PG clamps and sundry items likealuminium lugs,jumper,binding Tape etc directed by engr-in-charge.
S&F in repair danger notice plate made out of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skul and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size,for HT,25x20 cm in size complete all as specified and directed by Engr-in-Charge.
S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type ofstandard rails strain- ingbolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
S&F in repair GI pipe light grade 50 mm dia galvanised with all fitting to be laid in trench/wall/pole for the protection of cable under road/poles/wall/floor etc complete and PCC path complete all as directed by Engineer-in-charge .
S&F in repair of Stay assembly complete with GI stay rod 20 mm dia 1800 mm long, MS plate 230x2306 mm, stay bow,loop insulator, PCC 1:3:6, connecting bracket of suitable MS flat and nut bolt washers etc complete all as specified in electrical plate No 1 of SSR Part-1 including taking out old stay assembly complete all as specified and as directed by Engr-in-Charge. (Note:- Excavation and PCC measured and paid separately)
M&L for cement concrete type D2 1:4:8 (40mm graded aggregate) in pole/stay/ plinth etc in foundation filling completed all as directed by Engr-in-Charge.
S&F in repair Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending (cold or hot), drilling holes for bolts, bent to any shape or size as directed and inclusive of one primer coat of red oxide, one under coat of zinc oxide and one finishing coat of aluminium paint complete all as specified and directed by Engr-in-Charge.
S&F in repair pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two GI washers and one GI nut, 100mm height, 65mm dia for 1100 volts grade complete.
S&F in repair shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps, washers, insulator bolts, washers and nuts of size 75mm height and 90mm dia size of strap 31x3mm and dia of bolts 12mm for working pressure 1100 volts grade complete all as specified and as directed.
Supply and erection in replacement truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection ,complete all as specified and directed by the Engr-in-Charge. Note:-Excavation & PCC work shall be measured and paid separately.
S&F in repair loop type insulator, vitreous porcelain white, brown or green large size with overall dimensions 90mmx140mm clearance of hole 25.5mm complete.
S&F in repair ACSR conductor of (weasel) 6/1/2.59 for LT line (0.433 KV), straching properly on insulators and binding with aluminium binding wires,jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge.
M&L for cement concrete type C2 1:3:6 (40mm graded aggregate) in copping of poles all as directed by Engr-in-Charge.
S&F in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
M&L for Open the cover of transformer any type/size on site and filling in with new transformer oil low viscosity of approved make as per IS-335 of 1992 including heating of oil and die-electric strength 70 KV when tested at 4mm gap all as specified.
M&L Earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable complete all as specified & directed by Engr-in-charge.
Supply & fixing in replacement, install testing and commissioning of feeder pillar box ,out door type Kiosk shape,three phase, 4 wire, Cupper bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , groutingproperly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cableconnectionstotheMCCBs voltmeter,Ammeter and cable lugs etc
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 99,771.00 and any other reduction if any from quoted amount.
osho traders
M/S HIGHLAND ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .