Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | ₹12.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹12.7 L+₹39,723 (3.22%)Rejected-Finance DISTT FEROZPUR | ₹12.7 L+₹39,723 (3.22%) | L2 | Rejected-Finance L2 |
| 3 | L3₹13.1 L+₹82,764 (6.72%)Rejected-Finance NA | NA | NA | 121004 | ₹13.1 L+₹82,764 (6.72%) | L3 | Rejected-Finance L3 |
Tender Value
₹14.2 L
EMD Value
₹28,320
Closing Date
16 Jan 2026, 12:00 pmClosed
Executive Engineer
Electrical Division PWD B and R Hukky Chowk Faridkot
Repair of Road lighting on 4 Lane of Faridkot-Sadiq-Guruharsahai Road Distt. Ferozepur 5.35 KM.
2026_CEPW_157323_1
10 / 06.01.2026
Open Tender
Electrical Works
Percentage
90 days
Ferozepur
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹28,320
Faridkot
10 Feb 2026
6 Jan 2026
16 Jan 2026
6 Jan 2026
16 Jan 2026
6 Jan 2026
12 Jan 2026
GALVANIZED STEEL OCTAGONAL POLES FOR WIND VELOCITY OF 169 Km/ HOUR:
Supply and erection of Galvanized Steel Octagonal Pole (Sheet thickness 3mm) designed to withstand wind speed 169km/ hour of suitable length (Raw material confiming to IS-5986 (FE-510), BSEN-10025S- 355J or ASTM-572A (GR-50)) and thickness of galvanization (70mm thick) conforming to IS:2629/ IS:2633/ IS:4759, BSEN-ISO-1461- 1991 OR ASTM-A123/A123M-02. The pole shall be in single piece hot dip galvanized and shall be tapered towards the top. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The octagonal pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level as required:-
Galvanized Octagonal Pole Overall Length 7 metre (Sheet thickness 3mm), Top dia.(A/F) 70mm and bottom dia. (A/F) 130mm, Foundation size below G/L 550mm x 550mm x 1400mm, 4Nos. Foundation Bolts size 20mm dia., Length≥700mm with Base Plate Dimensions 240mm x 240mm x 16mm Thick
GALVANIZED OCTAGONAL POLE BRACKETS:
SINGLE/ DOUBLE ARM BRACKETS:
Supply and erection of bracket for galvanized octagonal pole, the bracket should be fixed on the top of the pole having top outer dia. 70mm to 90mm (A/F) complete in all respect as approved by the Engineer-in-charge at site:-
XLPE INSULATED ARMOURED CABLES (LOOSE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Single arm bracket 1.5 metre long for galvanized octagonal pole
Overall size 10sq.mm (4Core) Armoured (Loose)
Overall size 16sq.mm (4Core) Armoured (Loose)
PVC INSULATED FR COPPER CONDUCTOR CABLES:
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1.5sq.mm (Un-sheathed)
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 50/38mm (Outer/ Inner dia.)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:
MINIATURE CIRCUIT BREAKERS:
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:
CUBICAL PEDESTAL:
Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:-
Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm
MCCB's (MOULDED CASE CIRCUIT BREAKER):
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
GALVANIZED IRON PIPES AND G.I. EARTHING
Supply & erection of G.I. pipe (A-Class) as per IS:1239 (Part-I) 2004 including sockets, bends, inspection boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
Galvanized Iron Pipe 50mm dia. (A-class) Flushed
TIMER:
Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C- Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts)
G.I. EARTHING:
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length)
Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:-
GI Earth rod 20 mm dia., 3 mtr. Long
CEMENT CONCRETE MUFFS:
Making of Cement Concrete muff of suitable size and length with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole sufficient to completely flush a SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirming to IS:14772, inner dimensions 250mm x 200mm x 100mm with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's). The SMC Junction Box is to be fixed with the pole by a MS flat clamp of size 20mm x 2mm thick. PVC pipe 40mm dia. (2No.x0.60m) should be provided for incoming and outgoing cables. The outer surface of the muff shall be finished with pure cement & two coats of white snowcem complete in all respect as approved and desired by the Engineer In-Charge at site:-
Cement Concrete Muff of Overall Size 450mm dia., 80cm Long with making an extra collar (If pole installed in Centre verge/ Footpath) will be provided with 1:2:4 cement Sand & concrete mixture around the Steel tubular pole. The size of collar (height is 40cm & dia. is 45cm including pole dia i.e. 168.3mm)
Supply and erection of LED Street Light 90 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as perspecifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab
ROB TO TRUCK UNION (1 KM ),CHANDAN PALACE TO KOHAR SINGH WALA CHOWK(1.35 KM)
GALVANIZED STEEL OCTAGONAL POLES FOR WIND VELOCITY OF 169 Km/ HOUR:
Supply and erection of Galvanized Steel Octagonal Pole (Sheet thickness 3mm) designed to withstand wind speed 169km/ hour of suitable length (Raw material confiming to IS-5986 (FE-510), BSEN-10025S- 355J or ASTM-572A (GR-50)) and thickness of galvanization (70mm thick) conforming to IS:2629/ IS:2633/ IS:4759, BSEN-ISO-1461- 1991 OR ASTM-A123/A123M-02. The pole shall be in single piece hot dip galvanized and shall be tapered towards the top. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The octagonal pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level as required:-
Galvanized Octagonal Pole Overall Length 7 metre (Sheet thickness 3mm), Top dia.(A/F) 70mm and bottom dia. (A/F) 130mm, Foundation size below G/L 550mm x 550mm x 1400mm, 4Nos. Foundation Bolts size 20mm dia., Length≥700mm with Base Plate Dimensions 240mm x 240mm x 16mm Thick
GALVANIZED OCTAGONAL POLE BRACKETS:
SINGLE/ DOUBLE ARM BRACKETS:
Supply and erection of bracket for galvanized octagonal pole, the bracket should be fixed on the top of the pole having top outer dia. 70mm to 90mm (A/F) complete in all respect as approved by the Engineer-in-charge at site:-
XLPE INSULATED ARMOURED CABLES (LOOSE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Single arm bracket 1.5 metre long for galvanized octagonal pole
Overall size 10sq.mm (4Core) Armoured (Loose)
Overall size 16sq.mm (4Core) Armoured (Loose)
PVC INSULATED FR COPPER CONDUCTOR CABLES:
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1.5sq.mm (Un-sheathed)
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 50/38mm (Outer/ Inner dia.)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:
MINIATURE CIRCUIT BREAKERS:
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:
MCCB's (MOULDED CASE CIRCUIT BREAKER):
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
GALVANIZED IRON PIPES AND G.I. EARTHING
Supply & erection of G.I. pipe (A-Class) as per IS:1239 (Part-I) 2004 including sockets, bends, inspection boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
Galvanized Iron Pipe 50mm dia. (A-class) Flushed
TIMER:
Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C- Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts)
G.I. EARTHING:
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
Earthing with 7/14 S.W.G. (7/2.18mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length)
Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:-
GI Earth rod 20 mm dia., 3 mtr. Long
Supply and erection of LED Street Light 90 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as perspecifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab
CEMENT CONCRETE MUFFS:
Making of Cement Concrete muff of suitable size and length with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole sufficient to completely flush a SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirming to IS:14772, inner dimensions 250mm x 200mm x 100mm with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's). The SMC Junction Box is to be fixed with the pole by a MS flat clamp of size 20mm x 2mm thick. PVC pipe 40mm dia. (2No.x0.60m) should be provided for incoming and outgoing cables. The outer surface of the muff shall be finished with pure cement & two coats of white snowcem complete in all respect as approved and desired by the Engineer In-Charge at site:-
Cement Concrete Muff of Overall Size 450mm dia., 80cm Long with making an extra collar (If pole installed in Centre verge/ Footpath) will be provided with 1:2:4 cement Sand & concrete mixture around the Steel tubular pole. The size of collar (height is 40cm & dia. is 45cm including pole dia i.e. 168.3mm)
Less Dismental Material
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.79 MB
approvedboq.pdf
Tender Documents • 1.36 MB
SBD.pdf
Tender Documents • 11.20 MB
Condition.pdf
Tender Documents • 2.12 MB
AdditionalSBDcondition.pdf
Tender Documents • 0.24 MB
Checklist_upload.pdf
Additional Documents • 0.06 MB
BOQ_318924.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .