Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | L1 | Accepted-AOC Deposited performance security | |
| 2 | Rejected-Technical 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical Technically disqualified | |
| 3 | Rejected-Technical 01 MADHU BHAWAN FIRST FLOOR FLATE NO 01 NAWADIH DHANBAD JHARKHAND 828130 | DHANBAD | JHARKHAND | 828130 | - | Rejected-Technical Technically disqualified |
| Sl No | Description | Qty | Unit | RAJA ELECTRICAL WORKS L1 |
|---|---|---|---|---|
| 1.00 | Replacement of conservator oil level indicator with low oil alert and indicator | 7 | Nos | 17,250 ₹1,20,750 Lowest |
| 2.00 | Replacement of drain valve of 2 inch dia size | 7 | Nos | 3,000 ₹21,000 Lowest |
| 3.00 | Supply and Providing of Digital type winding temperature meter and oil temperature meter. | 14 | Nos | 60,000 ₹8,40,000 Lowest |
| 4.00 | Supply and Providing of rdt port for oil temperature sensing and winding temperature sensing of 6 mtr length cable . | 14 | Nos | 19,000 ₹2,66,000 Lowest |
| 5.00 | Supply and Providing of control cable for trip control and meter operation 16 core 2.5 sq mm . | 250 | Mtr. | 500 ₹1,25,000 Lowest |
| 6.00 | Supply and Providing of cooling fan 415V ac, 6 blade with IP65, no of poles 4,voltage 415Vvolt,input power 900 watt, Air flow 20500m3/hr, Full load current 5 Amps, Speed 960 rpm, water protection IP65. | 21 | Nos | 32,500 ₹6,82,500 Lowest |
| 7.00 | Structural steel work riveted , bolted or welded in built up sections , trusses and Framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete . | 1,125 | Kg. | 100 ₹1,12,500 Lowest |
| 8.00 | Total impact of GST for the purpose of CTC | 1 | No. | - |
Tender Value
₹23.5 L
EMD Value
₹29,400
Closing Date
15 Sept 2025, 11:00 amClosed
SO(EnM), BnK
GM Office, BnK Area, Bermo, Bokaro, Jharkhand.
Providing of Digital OTI and WTI with cooling arrangement for 7 nos of power transformer at 33kv/11kv at main regional substation MRSS, BnK Area
2025_CCL_343073_3
SO(EnM)/e-tender/25-26/10
Open Tender
Electrical and Maintenance Works
Item Rate
18 days
MRSS
As per NIT
2 documents required · 2 mandatory
₹29,400
12 Dec 2025
4 Sept 2025
16 Sept 2025
4 Sept 2025
15 Sept 2025
5 Sept 2025
4 Sept 2025 - 11 Sept 2025
Amount
Replacement of conservator oil level indicator with low oil alert and indicator
Replacement of drain valve of 2 inch dia size
Supply and Providing of Digital type winding temperature meter and oil temperature meter.
Supply and Providing of rdt port for oil temperature sensing and winding temperature sensing of 6 mtr length cable .
Supply and Providing of control cable for trip control and meter operation 16 core 2.5 sq mm .
Supply and Providing of cooling fan 415V ac, 6 blade with IP65, no of poles 4,voltage 415Vvolt,input power 900 watt, Air flow 20500m3/hr, Full load current 5 Amps, Speed 960 rpm, water protection IP65.
Structural steel work riveted , bolted or welded in built up sections , trusses and Framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete .
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .