Loading…
Loading…
Tender Value
₹6.8 Cr
EMD Value
₹6.6 L
Closing Date
24 Jul 2026, 6:00 pm
Chief Engineer Bathinda zone
HQ CE Bathinda Zone, Bathinda Mil Stn-151004
CONVERSION OF HT OVERHEAD LINE INTO UNDERGROUND CABLE AT LALGARH JATTAN MIL STATION AND SPL REPAIR AND REPLACEMENT AGAINST BER 33slash11 KV POWER TRANSFORMER AT SRIGANGANAGAR
2026_MES_776352_1
845877
Open Tender
Electrical and Maintenance Works
180 days
GE LALGARH JATTAN
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE LALGARH JATTAN
₹6.6 L
Yes
3 Jul 2026
3 Jul 2026
27 Jul 2026
3 Jul 2026
24 Jul 2026
17 Jul 2026
4 Jul 2026 - 24 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.9999 | Lump sum price worked out by the tenderer for BUILDING/STRUCTURE WORKS as listed in Schedule ‘A’ Part-I(Ref pre-priced schedule attached separately) | 1 | Lump sum | 16,57,590 | ₹16,57,590 |
| 0.0000 | Lump sum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately) | 1 | Lump sum | 2,125.54 | ₹2,125.54 |
| 0.9999 | Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately) | 1 | Lump sum | 2,58,28,883.87 | ₹2,58,28,883.87 |
| 0.0000 | Lump sum price worked out by the tenderer for EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately) | 1 | Lump sum | 39,96,041.01 | ₹39,96,041.01 |
| 2Schedule 'A' Part-V(MISCELLANEOUS PARTS) | |||||
| 0.9999 | Dismantling unserviceable PCC Poles of any description and any size including demolition of Cement Concrete (as/if required) and made good disturbed Ground, complete all as specified and as directed.
NOTE : Unserviceable Poles will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately. | 30 | Each | - | - |
| 0.9999 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 160 mm, minimum inside dia 120 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. | 18,500 | Running Metre | - | - |
| 0.0000 | Supply and fixing Horizontal Type Switch air break, gang operated outdoor, HT 11000 volts triple pole 400 Amps 3 polymer insulator per phase rotating vertical type, with fixed contacts of phosphorous bronze and moving contacts , manually operated from ground level with operating mechanism including mild steel galvanized light grade 25 mm bore operating rod, pad locking arrangements, MS arcing horns, flexible braiding earthing blades, rod and contacts without drop out fuse assembly and jumpers with mink conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for vertical mounting, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. | 8 | Each | - | - |
| 0.0000 | Supply and Fixing in replacement Drop out expulsion fuse assembly with fuse carrier triple pole HT 11000 volts, 200 Amps, out door type (having two Nos post polymer insulator mounted on MS channel for each pole ) and jumpers with conductors line taps, clamps, colour coated HT sleeves and fitting, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. | 8 | Each | - | - |
| 0.9999 | Supply and fix in repairs metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, polymer housing, single column and single phase construction, distribution class, medium duty, nominal discharge current 5 kA, repetitive charge transfer rating (Qrs) more than 0.2 C, thermal charge transfer rating (Qth) more than 0.7 C, nominal system voltage 11 kV, highest system voltage 12 kV, rated voltage of arrester 9 kV, continuous operating voltage 7.2 kV, temporary overvoltage (10.50 kV for 1 s, 9.90 kV for 10 s, 9.35 kV for 100 s), rated short circuit current 20 kA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 75 kV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 22 kV, high current impulse withstand capability (4/10 µs) 65 kA, minimum creepage distance 300 mm complete all as specified and as directed. | 4 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Finaltender.pdf
Tender Documents • 1.34 MB
BTD-084 E&M (1R-2) 18-9-2017 EXTENAL ELECTRICAL DETAIL SHOWING STREET LIGHT POLES & FITTINGS.PDF
Tender Documents • 0.10 MB
BTD-084 E&M (2R-2) 18-9-2017 EXTENAL ELECTRICAL DETAIL SHOWING STREET LIGHT POLES & FITTINGS.PDF
Tender Documents • 0.07 MB
BTD-095 (1R-2) 20 -07-2023.pdf
Tender Documents • 0.10 MB
BTD-095 (2R-2) 20 -07-2023.pdf
Tender Documents • 0.11 MB
BTD-805R (1-3) 30 JAN 2020.PDF
Tender Documents • 0.47 MB
BTD-805R (2-3) 27 NOV 2018 TD OF DRAINS.pdf
Tender Documents • 0.08 MB
BTD-805R (3-3) 27 NOV 2018 TD OF DRAINS.pdf
Tender Documents • 0.07 MB
BTD-806 1-4 (04-07-2017).PDF
Tender Documents • 2.47 MB
BTD-806 (2-4 3-4 4-4) 25.08.11.PDF
Tender Documents • 4.86 MB
BTD-806 3-4 DT 25-08-11.pdf
Tender Documents • 0.12 MB
BTD-806 4-4.pdf
Tender Documents • 0.08 MB
BTD-836 (1-1) 07 AUG 2021.pdf
Tender Documents • 0.39 MB
BTD-850 (1-1) 05112015.PDF
Tender Documents • 0.09 MB
BTD-851 (1-1) 040216.PDF
Tender Documents • 0.25 MB
BTD-890R (1-4) 15 JUL 2023.pdf
Tender Documents • 0.11 MB
BTD-890R (2-4) 15 JUL 2023.pdf
Tender Documents • 0.12 MB
BTD-890R (3-4) 15 JUL 2023.pdf
Tender Documents • 0.12 MB
BTD-890R (4-4) 15 JUL 2023.pdf
Tender Documents • 0.11 MB
BTD-892 1- 5 18-09-2018.pdf
Tender Documents • 0.11 MB
BTD-892 2- 5 18-09-2018.pdf
Tender Documents • 0.09 MB
BTD-892 3-5 20-11-2018.pdf
Tender Documents • 0.09 MB
BTD-892 4-5 05022021.pdf
Tender Documents • 0.11 MB
BTD-892 5- 5 18-09-2018.pdf
Tender Documents • 0.07 MB
BTD-900 26 SEP 2022 TD RAIN WATER HARVESTING.PDF
Tender Documents • 3.24 MB
BTD-921R SHT NO 01 OF 01 DT 15-07-2025.pdf
Tender Documents • 0.85 MB
BTD-922- SHT 01 OF 02 DT 22-01-25 REV DT 10.02.2025.pdf
Tender Documents • 0.75 MB
BTD-922- SHT 02 OF 02 DT 22-01-25.pdf
Tender Documents • 0.47 MB
BTD-925 SHT NO. 1-2 DATE 26-5-25.pdf
Tender Documents • 0.20 MB
BTD-925 SHT NO. 2-2 DATE 26-5-25.pdf
Tender Documents • 0.15 MB
sk 903.pdf
Tender Documents • 0.13 MB
BTD-006 (1R-2) 23-03-2023 FLOOR JOINTS.pdf
Tender Documents • 0.06 MB
BTD-006 (2R-2) 07 JUN 2016 FLOOR JOINTS.pdf
Tender Documents • 0.06 MB
BTD-038 (1R-2) 30-01-2017 WHB WITH SOAP NICHE MIRROR FOR LIVING ROOM SKERTING & DADO.PDF
Tender Documents • 0.09 MB
BTD-038 (2R-2) 07 JUN 2016 WHB WITH SOAP NICHE MIRROR FOR LIVING ROOM SKERTING & DADO.PDF
Tender Documents • 0.07 MB
BTD-039 (1R-1) 07 JUN 2016 SECTIONAL ELEVATION SHOWING DIFFR.PDF
Tender Documents • 0.09 MB
BTD-046 (1R-1) 07 JUN 2016 METER BOX -SWITCH BOX ELECTRIC (2).PDF
Tender Documents • 0.08 MB
BTD-053 (1R-1) 10 MAR 2017 RCC JALI & EXHAUST FAN.PDF
Tender Documents • 0.11 MB
BTD-072 (1R-2) 10 MAR 2017 FIRE POINT.PDF
Tender Documents • 0.11 MB
BTD-072 (2R-2) 10 MAR 2017 FIRE POINT.PDF
Tender Documents • 0.08 MB
BTD-80R 1-2 DT 27 -02-2024.pdf
Tender Documents • 0.10 MB
BTD-80R 2-2 DT 27-02-2024.pdf
Tender Documents • 0.09 MB
BTD-081 (1R-2) 18-9-2017 RCC-STEEL POLES AND ACCESS- ORIES F.PDF
Tender Documents • 0.11 MB
BTD-081 (2R-2) 18-9-2017 RCC-STEEL POLES AND ACCESS- ORIES F.PDF
Tender Documents • 0.08 MB
BTD-923.pdf
Tender Documents • 0.35 MB
CEBT-S-5005-01-25 SHT NO 01 OF 02 DT 09-10-25.pdf
Tender Documents • 0.61 MB
CEBT-S-5005-01-25 SHT NO 02 OF 02 DT 09-10-25.pdf
Tender Documents • 0.86 MB
BOQ_869384.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid