Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 CrAccepted-AOC | ₹49.4 Cr | L1 | Accepted-AOC Accepted being L1 bidder. |
| 2 | L2₹51.5 CrRejected-Finance N 65 MIDC HINGNA INDUSTRIAL AREA HINGNA NAGPUR MAHARASHTRA 440016 UDYAM MH 20 0029592 27AADCM7418C1ZN R M MII STATUS AS VERIFIED | NAGPUR | MAHARASHTRA | 440016 | ₹51.5 Cr | L2 | Rejected-Finance Rejected being higher than L1 bidder. |
| 3 | L3₹54.1 CrRejected-Finance | ₹54.1 Cr | L3 | Rejected-Finance Rejected being higher than L1 bidder. |
| 4 | L4₹59.6 CrRejected-Finance 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹59.6 Cr | L4 | Rejected-Finance Rejected being higher than L1 bidder. |
| 5 | L5₹61.3 CrRejected-Finance | ₹61.3 Cr | L5 | Rejected-Finance Rejected being higher than L1 bidder. |
Tender Value
₹55 Cr
EMD Value
₹15 L
Closing Date
10 Jun 2023, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVISION OF FOUR ORP BLAST PENS WITH LINK TAXI TRACK AND ALLIED WORKS AT AFS CHABUA
2023_MES_588033_1
88644/CHAB/E8
Open Tender
Civil Works
900 days
Chabua
As per tender documents
7 documents required · 7 mandatory
₹3,000
GE (P) NO. 02 (AF) CHABUA
₹15 L
Yes
21 Jul 2023
1 Apr 2023
12 Jun 2023
1 Apr 2023
10 Jun 2023
3 Jun 2023
Amount
SCHEDULE "A" Part - I (BUILDINGS/STRUCTURES WORK) Details of Buildings are given here-in-before:-
SCHEDULE "A" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- V (PQC ROAD/ HARDSTANDING/ CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (TAXI TRACK AND ALLIED WORKS) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XI ( FENCING AND STEEL GATE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XII (AIR CONDITIONING) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XIII (FLAME PROOFING) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XIV (LIGHTENING CONDUCTOR) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART -XV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK Maternal & Labour Granular Sub Base (GSB) grading as per Grade-I (as specified in table 400-2 MORTH, IRC specitication) over excavated level and compacted sub grade with stone aggregate of specified grading by using machanical motor grader, spreding, levelling, rolling with tandem vibratory roller exceeding 8 ton not exceeding 12 ton and consolidating to required gradient and camber to achieve 98 % of MoD of soil including necessary form work if required complete all as specified and directed.
Forming embankement including raising earth, spreading in layers n exc 30 cm thick, watering ramming/ rolling with tondome roller ( Static and vibratory) under optimum moisture condition to 98% modified proctor density and finished to required gradient, size and camber as required to 'K' value in field at top of embankment (subgrade of pavement) shall not be less than 5kg/Cm²/cum complete all as specified and as directed.
Labour only for in-situ soil stabilization of 150 mm compacted thickness by blending pulverized excess soil and crushed concrete aggregate soil in volumetric proportion of 70: 30 respectively. Including rolling and compacting upto required gradient and the materials are mechanically mixed, spread and leveled on the sub-grade with watering ramming/ rolling with tandem roller (Static and vibratory) under optimum moisture condition to 98% modified proctor density and finished to required gradient, size and camber. NOTE: Crushed concrete aggregate material will be available at 05 End site not exceeding 250 meter.
Internal Electrification Supply and fixing for 1 x 20 watt, LED tube light 4 feet indoor decorative aluminium extruded LED batten integrated batten T8 fitting 230 V with all accessories, led lamp, connector block, prewired and including connecting up with twin core twisted flexible copper conductor of suitable size compete all as specified and as directed.
Supply and fixing for 1 x 10 watt, LED tube light 2 feet, indoor decorative aluminium extruded LED batten integrated batten T5 fitting 230 V with all accessories, led lamp, connector block, prewired and including connecting up with twin core twisted flexible copper conductor of suitable size compete all as specified and as directed.
Supply and fixing for 1x35 Watt LED pressure die cast aluminium housing LED security street light lumaniare fittings with IP 66 protection powder coated and suitable for working with 230 Volts, AC Supply with all accessories with and including LED lamp and necessary electric connection with using required size copper cable complete all as specified and as directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised earth wire of size 4 mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re- inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) including testing complete all as specified and as directed.
Internal Water supply Supply and fixing for 15mm bore angle stop cock cast copper alloy CP with long shank and cup. fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and as directed
Supply and fixing for 15mm bore shower rose cast copper alloy CP with long shank and cup, fancy type on minimum length 300 mm complete all as specified and as directed
PQC ROAD/ HARDSTANDING/ CULVERT Construction of brick masonary culvert of span 1.20 m and 8 M long including exavation,PCC(1:4:8) type D-2 in foundation, brick work in CM(1:6), RCC M-25 (Design Mix) Slab complete all as specified and as shown on Drg.
Sewage disposal. M & L for provn of on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., for conventional type for 30 Users complete all as specified and as directed.
M & L for provn of soakage wells excavation in any type of soil, foundation in PCC 1:3:6 ealls of honey combed masonary with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M25/SFRC cover, inerconnecting pipes of RCC/DWC complete flled with brick bats of size 1.2 M dia X 3 M effective depth all as shown on drg.
FENCING AND STEEL GATE Supply only concertina coil of 610 mm dia of 1 Mtr mm dia in 06 coil in stretch of 1.0m length for fencing work,straining and fixing to angle iron/barbed wire with and including necessary clips (for each bundle of coil) for securing complete all as specified and directed.
Fixing only concertina coil of 1 mtr dia in 06 coil for fencing work,straining and fixing to angle iron/barbed wire for securing complete all as specified and directed.
DG SET Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 160 KVA/ 128KW, water cooled, 415 Volts(AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Chabua. (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection ,Suitable No cylinders ,four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 200 KVA/128 KW at outdoor atmospheric conditions at Chabua. ,(Taking all derating factor into consideration), , 12/24 Volt(as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with techometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc .
Contd from item No. 30.00 here-in-before (v) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002. (vii) External cubicle Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set. (viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. (ix) Factory Test shall be carried out by testing officer nominated by AO. (x) Pre- commissioning test shall be carried out by testing officer nominated by Accepting Officer.”
M & L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 mm x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 50mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on complete all as specified and as directed.
Materials and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with copper strip of size 20 mm x 3 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on complete all as specified and as directed
AIR CONDITIONING Supply and install split type Air conditioner units with minimum 5 star rating EER 3.9 inverter type with dual compressor and plasma filter, capacity 1.5 TR , indoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality including all rquired copper pipes and suitable size of clamp for fixing of outdoor complete all as specified and directed.
Supply and Fix voltage stablizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 140V to 280V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and directed.
FLAME PROOFING Supply & fix Flame proof three phase Distribution Board 2 way TPN outgoing MCB TPN 25 A and one MCB TPN incommer 63 Amps with 200 Amps Busbar complete all as specified and directed.
Supply & Fix Flame proof LED fittings 60 Watt complete all as specified and directed.
S&F flame proof SPN DB 8 way having 200A busbar double door, complete all as specified and directed.
Supply & Fix flame proof MCB single pole, 16 amps complete all as specified and directed.
M&L for flame froof MCB single pole & neutral , 32 amps complete all as specified and directed.
EXTERNAL WATER SUPPLY Construction of brick massonry valve pit chamber of inner dimension 60x60x60 cms suitable for sluice valves upto 50mm size with PCC : 1:4:8 type D-2 for foundation brick work in cm 1:6 rendering 1:4, 15mm plastering , comping in PCC 1:2:4 type B-1 , including MS Sheet cover of hickness 2mm on 50x50x6.0mm angle iron frma work including two coats of synthetic enamelled paint paint overa coat of red oxide primer with making provision of locking arrangement and necessary excavation in soft/loose soil, returing , filling in and removal of surplus soil to a distances 15 mtr not exc 50m complete all as specified and as directed.
M&L for cutting of existing 100 mm GI pipe line & providing connection for 50 mm GI pipe line with necessary fittings complete all as specified and as directed.
External Electrification Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply, installation, commissioning and testing of size suitable of Main LT Panel (05 & 23 End) to accomdate mentioned accessories , factory made (CPRI approved) outdoor cubical compartmental type double door both side openable with hinged doors & locking arrangement made out of not less than 3 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x6mm angle iron frame including earthing stud lebeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 stage process), duly fixed in ground with PCC foundation (1:2:4) type B1 with danger notice plate of 1.6mm thick mild steel sheet, vitrious enamelled (white) with letters figures and conventional skull and bones in signal red colour suitable for 3 phase 4 wire system 500Volts grade with necessary wiring with PVC sheathed strander al conductor of appropriate length size with and including fixing lugs bolts, screws etc complete all as specified and directed. For safety , panel shall be finger touch proof and it should have IP-65 Protection in module door open condition. Busbars shall be made of high conductivity, and high strength Aluminum E91 grade as per IS 5082-1981, of rectangular cross sections better suitable for full load current for phase bus bars and half/ full rated current for neutral bus bar or as per requirement .
Contd from item No. 43.00 here-in-before The busbars shall be supported on non-breakable, non-hygroscopic epoxy resin or glass fiber reinforced polymer insulated supports.The material and the spacing of the Busbar supports should be same as per the type tested assembly (TTA). All bus bars shall be provided in a separate chamber and all connections shall be done by bolting. Panel comprising of the following accessories :- Incoming (a) Aluminium busbar of rated capacity 500 Amps cover with PVC insulated sleeves including insulator, nuts, bolts etc incl connection complete - 01 set (b) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 36 KA of 250 Amps with Fixed thermal and magnetic setting-01 No + 01 Standby (c) Neon indicator lamp with holder (Yellow, Blue,Red)- 01 set (Set of three) (d) Digital VAF meter with suitable CTs - 01 No. Out going: (a) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 36 KA of 100 Amps with adjustable magnetic setting- 02Nos + 1 Standby. Out going: (a) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 36 KA of 63Amps with adjustable magnetic setting- 01Nos + 1 Standby.
Supply, installation, commissioning and testing of size suitable of FDP NO-01(23 End) to accomdate mentioned accessories , factory made (CPRI approved) outdoor cubical compartmental type double door both side openable with hinged doors & locking arrangement made out of not less than 3 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x6mm angle iron frame including earthing stud lebeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 stage process), duly fixed in ground with PCC foundation (1:2:4) type B1 with danger notice plate of 1.6mm thick mild steel sheet, vitrious enamelled (white) with letters figures and conventional skull and bones in signal red colour suitable for 3 phase 4 wire system 500Volts grade with necessary wiring with PVC sheathed strander al conductor of appropriate length size with and including fixing lugs bolts, screws etc complete all as specified and directed. For safety , panel shall be finger touch proof and it should have IP-65 Protection in module door open condition. Busbars shall be made of high conductivity, and high strength Aluminum E91 grade as per IS 5082-1981, of rectangular cross sections better suitable for full load current for phase bus bars and half/ full rated current for neutral bus bar or as per requirement .
Contd from item No. 45.00 here-in-before The busbars shall be supported on non-breakable, non-hygroscopic epoxy resin or glass fiber reinforced polymer insulated supports.The material and the spacing of the Busbar supports should be same as per the type tested assembly (TTA). All bus bars shall be provided in a separate chamber and all connections shall be done by bolting. Panel comprising of the following accessories :- Incoming (a) Aluminium busbar of rated capacity 200 Amps cover with PVC insulated sleeves including insulator, nuts, bolts etc incl connection complete - 01 set (b) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 63 Amps with Fixed thermal and magnetic setting-01 No (c) Neon indicator lamp with holder (Yellow, Blue,Red)- 01 set (Set of three) (d) Digital VAF meter with suitable CTs - 01 No. Out going: (a) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 63Amps with adjustable magnetic setting- 01Nos + 1 Standby. (b) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 16 Amps with adjustable thermal and magnetic setting- 01Nos (c) Supply and fixing 10 Amps SPN of 6 KA 240 Volts - 01 Nos (d) Analog timer switch 3 module - 01 Nos
BLANK
BLANK
M&L for Machinery /Equipment/chemical earthing complete with copper earth plate 90x60x5 mm burried directly in ground(earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised iron earth lead by means of bolt,nut as shown and washer of copper strip 32x6 mm as earthing lead earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil,earth pit in PCC 1:3:6 type C1 using 20 mm stone aggregate funnel,20 mm dia GI med grade water pipe,15 mm dia GI light grade earth lead protection pipe ,CI frame and cover, wire copper lugs,wire mesh,charcoal or coke and common saltin alternate layers all around the earth electrode pit cover including disposal of surplus soil to a distance not exceeding 50m,complete testing on completion all as shown in electrical plate no of SSR part No 1 all as directed.
Contd from item No. 50.00 here-in-before (q) Insulation resistance more than 10 mega Ohms. at 500 volt DC. (r) Contractor shall submit the general aggrangment drawing and details for approval before placing order. (s) Factory Test shall be carried out by testing officer nominated by AO. (t) Pre- commissioning test shall be carried out SEI/EI.” PROTECTION:- (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency. (iv) Single phase Prevention. (v) Spike and surge protection. (vi) Earth Fault protection. (vii) Test Reports as per clause 11.1 for any rating as pr clause 5.1 from BIS: 9815 (Part –I) reaffirmed 2004. (aa) Physical eximation (ab) Insulation resistance. (ac) High Voltage Test (ad) leakage current test. (ae) Provision of earting. (af) Output voltage. (ag) No load current. (ah) measurmet of no load losess. (aj) include voltage test.
Supply, Installation and Commissioning of 45 KVA Static Frequency Converter of Input Voltage 340-440V, 3Phase, 50Hz, Output Supply of 208 V( P-P) & 115V AC (P-N), 3 Phase, 400Hz with tolerance on voltage ± 10 volts on balance or unbalance load on input supply voltage with 50Hz frequency ± 6% with continuous rated power 45KVA, 208 V, 400Hz with a frequency adjustment of + 20Hz, output voltage adjustment range ± 5% of normal value the overall efficiency of frequency converter shall be >85% and overload capacity 110% overload for 30 minutes, 125% for 5 minutes and 170% overload for 30 seconds. The SFC shall meet the output Specifications i.e 45KVA, 208Volts, 3Phase, 400 Hz at rated input supply. The SFC shall consist of the metering device having microprocessor based digital display having scanning facility to monitor all parameters push button type contactor to switch ON/OFF, Indications for Mains ON, Inverter ON/OFF, LED/Alarm reset including 3 Nos outgoing feeder distribution panel suitable Having Incoming One 160 Amp 35 KA MCCB and 3 Nos Outgoing- 100 Amp FP MCCB 35 KA Single Phase Failure, Reverse Phase Sequence DC Under Voltage and protection for inverter-Output Overvoltage/under voltage, overload, Short-circuit, Over Temp, Output Over Frequency / Under Frequency. LCD display for input-Input Voltage, Current Frequency and output-Output Voltage, Current Frequency, MIMIC indication and audio alarms for input-Mains On/High/ Low/ Single Phasing/ Fail, DC On/High and output-Inverter On/ High/Low Overload /Trip complete with necessary MCCB control for input and output and ON/OFF Key switch suitable for operation upto 40 deg. Celsius and 90% RH with forced air cooling arrangement and noise level not exceeding 65dB complete with 30min battery backup as required including associated cabling, connections, terminations, mounting on base channels and erection on necessary cement foundation/ masonry foundation complete as per detailed specifications and as required..
S&F Cable Junction Box 210X155X92mm in size, made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) fixed on poles with flat aluminium clamps of size 25x3mm, nuts, bolts, washers etc. complete all as specified and as directed.
S & F street light fitting suitable for 1 x 36 watt CFL with MS housing, finished in bright red and having clear acrylic cover complete with, lamp holder, connecting block and one 36 watt CFL including all accessories pre-wired with 25mm bore medium grade GI pipe 1.5 m long mounting security light bracket bend to 120 degree angle and fixed to pole with necessary clamps (two pair) made of 40 x 6 mm MS flat with bolt and nuts and two coats of synthetic enameled paint over coat of red oxide primer including necessary connection and two single core 1.5 Sqmm PVC (nominal area) multistranded copper conductor cable complete all as specified and directed.
S & F for 70 watt LED flood light luminaire fitting with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with toughened clear glass cover complete with and including all necessary electric connection with copper wire from junction box to light fitting with and including 40 mm bore GI pipe (Light grade) bracket of 1.2 m long bend to shape as required, and fixed with clamp made out MS flat iron of size 40 mm x 5 mm and applying two coats of syenthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and as directed.
Design, manufacturing, supply, installation, Testing and commissioning of APFC Panel of 30 kVAr 7 stages as per The 440V APFC Panel shall be metal clad, indoor type floor mounted in Non drawout execution. Fabricated from Sheet steel shall be CRCA of minimum 2.0 mm thickness. Incomer Circuit breaker (MCCB) shall be mounted in a separate compartment and Metering compartment along with APFC Relay etc shall be separate. The position of various control switches, push buttons, louvers etc. requiring manual operation. The operational Height of Panel shall be at a height not less than 300mm and shall not exceed 1850mm from the finished floor level. Name plate for each incoming and outgoing feeder at front. All equipments of similar rating shall be interchangeable. Insulation Level Rated insulation voltage 1100 V One minute power frequency withstand voltage : 2.5 kV for power circuits 2 kV for control circuits Clearance in air (minimum) : Phase to phase - 25 mm Phase to earth - 19.0 mm Short Circuit Strength Rated short time withstand current not less than 36kA for 1sec. Rated peak withstand current not less than 52.5 kA. Busbars Busbars made of EC grade aluminium alloy equivalent to E91E WP as per IS 5082, 1981, size adequate for specified rated continuous and SC current. Three phase, neutral (with at least 50% rating of main buses) and continuous earth bus. Bus bar shall be provided with proper grade & colour of heat shrinkable sleeve.
Contd from item No. 55.00 here-in-before Rating of horizontal buses shall be same as that of incomer circuit breakers and vertical run shall be same as that of outgoing breaker rating Temperature rise of bus bars shall not be more than 40 deg. C above an ambient of 50 deg. C. Construction Features (Mechanical Design) Sheet steel clad, floor mounted, free standing design, non-dust proof construction Extension bus links properly spaced for terminating single cables of required size and above as well as for terminating multiple cables of all sizes. The interior of the switchboard shall be finished with OFF WHITE (RAL 7032) paint shade following specification:- (a) 2 kvar x 2 Nos. (b) 3 kvar x 2 Nos. (c) 5 kvar x 2 Nos. (d) 10 kvar x 1 No”.
Mecgale Pneumatics Pvt Ltd
NITYA NAND AND SONS CONTRACTORS PVT LTD
NARSINGH DEVELOPERS LLP
ARCHON POWERINFRA INDIA PRIVATE LIMITED
Agarwal Jagdish Construction Company Private Limited
NSC Projects Pvt. Ltd.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid