Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC NEAR CENTRAL JAIL LAXMI NAGAR P S RAMPUR DISTT GAYA PIN 823001 BIHAR | GAYA | GAYA | BIHAR | 823001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹10.0 L+₹21,975 (2.26%)Rejected-Finance MAGADH COLONY ROAD NO 5 GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹12.3 L+₹2.5 L (25.9%)Rejected-Finance 11A LAXMI VIHAR BANDHAN PALACE WALI GALI MODIPURAM MEERUT UTTAR PRADESH 250110 | MEERUT | UTTAR PRADESH | 250110 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹13.2 L+₹3.4 L (35.3%)Rejected-Finance MOCHARIM BODHGAYA GAYA 824231 | BODHGAYA | GAYA | BIHAR | 824231 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GAYA
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar, PIN-823005
Repair/maintenance of Summer and winter appliance at Mil Stn Gaya
2024_MES_638567_1
8060/GE/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GAYA
₹40,000
Yes
22 Mar 2024
22 Jan 2024
20 Feb 2024
22 Jan 2024
19 Feb 2024
7 Feb 2024
Amount
Comprehensive preventive & routine maintenance services of 1.5 TR window type air conditioner Make: Voltas/LG /Carrier/Blue Star or any other make on site installed at various location in the station by carrying out following checks and services:- (i) Cleaning of condenser and evaporator coils fins with mild detergent/chemical solution for descaling of coils and flushing with high-pressure jet of water after taking down the whole unit and refixing at the existing location or any other new location after servicing. (ii) Greasing of blower motors and all moving parts. (iii) Prevention of rusting of units (iv) Checking operation of controls of the air conditioner such as thermostat, relays, remote control etc. (v) Checking air flow through the supply air grill, return air grill, condenser.(vi) Checking air temperature at supply air grill, return air grill, inlet air condenser, outlet air from condenser. (vii) Checking firmness of supporting arrangement for the compressor, blower motor, air conditioners casing and fixing of air-conditioners etc., anti-rusting painting of the MS portion prone to rusting.(viii) Replacement of any component of air conditioners found defective after the above checks and tests
All as per item No. 1 above but for 1.5/2 TR split type air conditioner. (i) Cleaning, overhauling and servicing of each unit shall be carried out on quaterly basis. (ii) The AC units shall be checked completely and serviced/repaired thoroughly at least once in three months as prescribed by the manufacturer of the AC units. In addition to this AC units shall be attended on break down with in 24 hours after intimation and shall be get repaired with in 48 hours, failing which necessay recovery @ Rs 200 per AC per hrs shall be made.
S & F in repair refrigerant copper piping of size 1/4" internal dia in and including synthetic rubber foam insulation for split type AC complete all as specified and directed. Note: The quoted rate is inclusive of necessary T&P, rope, ladder etc with safety equipment for execution the work upto G+ one storie building.
All as per item Srl No. 3 above but for 1/2" internal dia pipe.
Disconnecting, dismantling and taking out existing burnt out compressor from window/split type Air conditioner 1.5 TR Capacity and supply & fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filled with compressor oil complete all as specified by Engr-in-Charge and testing on load for 24 hrs in summer complete all as specified and directed. Make : Carrier/ Hitachi/ Tecumseh/ Usha/ Voltas/ Blue Star
All as per item No. 5 above but for 2 TR window/split type air conditioner.
S & F in repair copper condenser motor suitable for 1.5 / 2 TR split type AC of any make/ model complete all as specified and directed. Make: As per OEM
S & F in repair copper condenser coil suitable for 1.5 TR window type AC of any make/ model complete all as specified and directed. Make: As per OEM
S & F in repair starting capacitor of 80 to 100 mFd capacity, ISI marked for 1.5/2 TR capacity window/ split type AC Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron
S & F in repair running capacitor of 36 to 45 mFd capacity, ISI marked for 1.5/2 TR capacity window/ split type AC complete all as specified and directed. Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron
S & F in repair blower motor double shaft, single/double speed, single phase, AC 230 V of 1/6 to 1/4 HP capacity to suitable for window type AC complete all as specified and directed. Make: As per OEM
S & F in repair blower motor single shaft, single/double speed, single phase, AC 230 V suitable for indoor unit of split type AC of 1.5/ 2.0 TR capacity complete all as specified and directed. Make: As per OEM
S & F in repair fan blade set suitable for window type AC of any capacity complete all as specified and directed.
S & F in repair fan blade set suitable for split type AC of any capacity complete all as specified and directed.
S & F in repair remote control with PC board complete suitable for existing model of split type AC of any capacity complete all as specified and directed. Make: As per OEM
S & F in repair thermostat switch of existing make and capacity window/split type AC 1.5/2 Ton capacity complete all as specified and directed.
M & L for repair to electronic control kit (PCB Kit) of split/window type AC of any make/ capacity complete all as specified and directed.
M & L for repairing & rewinding CFM motor of split type AC or blower motor of window type AC complete all as specified and directed.
S & F in repair air filter suitable for existing model of 1.5/2 TR split type AC complete all as specified and directed. Make: As per OEM
Supply and charging R-22 gas to maintain the required cooling effect as and when required in the split / window type AC or in any other cooling appliances complete all as specified and directed.
Supply and charging R-134 gas to maintain the required cooling effect as and when required in the water cooler, refrigerator, deep freezer or in any other cooling appliances complete all as specified and directed.
S & F in repair set of MS powder coated mounting brackets for 1.5/ 2.0 TR AC indoor unit, heavy duty including necessary expansion fasteners complete all as specified and directed.
S & F in repair MS stand suitable for window type AC unit upto 2 ton of capacity made out of 40mm x 40mm x 5mm angle iron including fixing arrangments like welding, fabrication and nuts & bolts complete all as specified & directed.
Taking down carefully Split type AC of any capacity with all accessories such as indoor unit, out door unit, copper pipe inlet outlet, flair nut etc. and shifting new position after minor repair including making good the opening of old location with cement mortor 1:3, treating the wall to matching with existing surface finish and making opening holes on brick wall at new location and gap well finish with cement mortor 1:3, making good the wall surface to match with existing surface, installation and commissioning with replacement of insulation of suction & discharge line complete all as directed.complete all as specified and directed. Note: (i) Replacement of any defective parts shall be measured and paid separately. (ii) The charging of gas shall be measured and paid separately.
Taking out old burnt out compressor (sealed unit) for Refrigerator/Deep Freezer 170/210/285/310 ltr capacity and replaced with with new one compressor as per existing make including charging of gas upto required level and testing complete all as specified and directed by Engr-in-Charge. Note: The quantity of gas shall be measured and paid seperately under relevent item.
Taking out old burnt out compressor (sealed unit) complete from water cooler of any size/capacity and replaced with new one compressor as per existing make including charging of gas upto required level and testing complete all as specified and directed by Engr-in-Charge. Note: The quantity of gas shall be measured and paid seperately under relevent item.
S & F in repair starting relay box type for refrigerator/deep freezer complete all as specified and directed.
S & F in repair thermostat switch for refrigerator of any size as per existing make complete all as specified and directed.
M & L for repairing and rewinding of blower motor of water cooler of any size capacity complete all as specified and directed.
S & F in repair of running capacitor 20 to 30 mFd suitable for refrigerator/deep freezer/ water cooler complete all as specified and directed.
S & F in repair of starting capacitor 40 to 60 mFd suitable for refrigerator/deep freezer/ water cooler complete all as specified and directed.
S & F in repair submersible water pump of desert cooler 230 Volt AC, discharge not less than 750 LPH at head 0.75 mtrs, ISI marked complete all as specified and directed.
M & L for repairing and rewinding of fan motor of desert cooler with copper winding wire of existing gauge complete all as specified and directed.
S & F in replacement wood wool pad (Khaus) including wire mesh for desert cooler complete all as specified and directed. Make: as per sample.
S & F in replacement PVC insulated round sheathed copper conductor cable of size 40/0.076, 3 core, ISI marked as per IS:694 complete all as specified and directed.
S & F in replacement PVC insulated round sheathed copper conductor cable of size 2.5 Sqmm, 3 core ISI marked as per IS:694 complete all as specified and directed.
S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 4 KVA complete all as specified & directed.
S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified & directed.
Supply, install, testing and commissioning steel body desert cooler electric driven 230 Volts AC, having nominal air delivery/capacity 6000 CuM per hour with 120 ltrs sump capacity having filter panel, grill, top of cooler body, cabinet made out of galvanized steel sheet (ISI marked to IS:277 latest) with zinc coating of thickness (nominal) 0.8mm and for sump tank 1.0mm, Fan motor size 500mm ISI marked as per IS:996 (latest), submersible pump, honeycomb filter pads with non-corrosive wire guard with provision of float valve inlet including stand complete all as specified and directed. Make: Symphony/ Bajaj/ Havells/ Crompton Note: Old deteriorated/unserviceable desert cooler shall be deposite in AGE E/M store yard.
S & F in repair sheet metal enclosure for single pole and neutral with two pin and earth plug top and socket complete with one single pole MCB 20 Amps complete all as specified and directed. Make: ABB/Legrand/Havells
M & L in replacement AC submain wiring with PVC insulated unsheathed FRLS copper conductor cable, 1100 Volt grade, multistranded of two runs of single core of size 4 Sqmm and one run of single core 2.5 Sqmm (as earth wire) cable and connected of common earth dolly including drawn through and including non metalic rigid PVC conduit medium grade ISI marked with accessories complete all as specified and directed.
Taking down geysers of any type and any capacity due to rusting of bolts / seepage of wall and re-installation at any location including S & F in repair of heavy duty pin type fastener 4 inch Job long and making necessary inlet/outlet electric & water supply connections from existing source to geyser complete all as specified and as directed
Inspection, checking adjustments and minor repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :- (a) Inspection, taking out of drain plug & dewatering and refixing the same complete all as directed. (b) Checking water tightness of storage tank. (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat upto 55ºC. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) The cost of spare parts required for repair & mainenance of geysers covered under this item shall be measured and paid separately under the relevant item as supply only. (j) Make of geysers covered under the scope of work :- Sidhson, Bajaj, Recold, Crompton, Orison, Ditz Premier, Peeco, Empire, Shakti, Sahas, Konark Note: Irrespective of the Number of complaints, work against this item of BOQ shall be completed with in 48 hours after handing over the Complaint slip failing which recovery @ Rs 200/-per geyser per day delay shall be effected from the contractors payment.
Supply only heating element, (Round / triangle type) 2 KW, 230 volts, ISI marked suitable for 25/35/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA / Bajaj / Recold /Theta.
Supply only thermostat switch for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. Make : USHA / Bajaj /Theta / Elcon.
Supply only indicator lamp for geyser of any type colour green & red complete all as specified and as directed. Make : Usha / Bajaj/ Crompton
Supply only base assembly, compatible to existing geyser with inlet, thermostat pipe, drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
Supply only stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25/35 ltrs capacity geysers (wt not less than 3.75 kg) as per sample complete all as specified and as directed.
Supply only of stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample complete all as specified and as directed.
S & F PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed. Make : PRAYAG/ POLYTUFF/ SHAKTI
M & L for taking down and spray painting to geyser of 25/50 Ltr capacity at site where installed and painting with synthetic enemal paint including filling of cavities with approved filler complete and refixing in existing after drying.
Supply and installation of water cooler partially stainless steel, electric driven single phase having approx storage capacity of 80 Ltrs and nominal cooling capacity of 40 Ltrs/hr complete all as specified and directed.
S&F of electric water heater 25 Ltr capacity, steel body with copper inner tank and heating element upto 2 KW capacity, 230 Volts, BEE 5 star rated with all accessories such as safety valve, thermostate, NRV, connection piece etc, fixing on wall through proper nut, bolt, and fastner including electric and water connection complete all as specified and directed. Make: Havells/Bajaj/Crompton Greaves/ Racold
BEHL ENGINEERS AND TRADERS
SINGHAL ENTERPRISES
M/S NARAYAN & SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .