| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.9 LAccepted-AOC WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | 1 | Accepted-AOC Accepted being L1 | |
| 2 | 2₹36.3 L+₹6.4 L (21.4%)Rejected-Finance | 2 | Rejected-Finance Rejected being not L1 | |
| 3 | 3₹38.6 L+₹8.7 L (29.1%)Rejected-Finance | 3 | Rejected-Finance Rejected being not L1 | |
| 4 | 4₹39.0 L+₹9.1 L (30.4%)Rejected-Finance | 4 | Rejected-Finance Rejected being not L1 | |
| 5 | 5₹40.1 L+₹10.2 L (34.1%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | 5 | Rejected-Finance Rejected being not L1 |
| Sl No | Description | Qty | Unit | MV Engineers And Contractors L6 | Rajindera Enterprises L3 | DS CONSTRUCTION L2 | Vijay Electricals L7 | mayur enterprises L1 | ALLIED CONSTRUCTION L4 | M P TYAGI ENGINEERS AND CONTRACTORS L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Earthing in replacement with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanized ironsides complete all as specified, including testing and commissioning complete all as specified and directed by Engg-in-Charge.
Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc.
(b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode. | 10 | Each Job | 2,900 ₹29,000 Lowest | 3,000 ₹30,000 | 3,000 ₹30,000 | 7,000 ₹70,000 | 3,000 ₹30,000 | 3,500 ₹35,000 | 5,000 ₹50,000 |
| 2.00 | Decarbunizing/cleaning complete outgoing/Incoming LT Air Circuit Breaker circuit of size 800/1000/1200 Amps ,srpring , arcing surfaces, 3 phase, cleaning with CTC and ensure proper decarburizing, re-fixing the same tightening the nuts, bolts thimbles for incoming and outgoing system complete, as specified and directed, rate quoted is inclusive of spring & cotton waste provided by contractor complete all as specified and directed by Engg-in-Charge. | 6 | Each Job | 2,999 ₹17,994 | 1,200 ₹7,200 | 1,000 ₹6,000 | 500 ₹3,000 Lowest | 2,000 ₹12,000 | 5,000 ₹30,000 | 2,000 ₹12,000 |
| 3.00 | S&F in replacement of UNSV MCCBs of capacity 400 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by Engg-in-Charge. | 2 | Each Job | 9,999 ₹19,998 Lowest | 15,000 ₹30,000 | 17,000 ₹34,000 | 14,000 ₹28,000 | 12,000 ₹24,000 | 14,000 ₹28,000 | 20,000 ₹40,000 |
| 4.00 | M&L for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamel paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters complete all as specified and directed by Engg-in-Charge. | 20 | Each Job | 1,999 ₹39,980 | 2,500 ₹50,000 | 500 ₹10,000 Lowest | 1,000 ₹20,000 | 2,000 ₹40,000 | 2,000 ₹40,000 | 500 ₹10,000 Lowest |
| 5.00 | All as per item No 04 above but of approx size upto 1.90 Sqm complete all as specified and directed by Engg-in-Charge. | 20 | Each Job | 1,999 ₹39,980 | 2,500 ₹50,000 | 500 ₹10,000 Lowest | 1,000 ₹20,000 | 2,000 ₹40,000 | 1,800 ₹36,000 | 500 ₹10,000 Lowest |
| 6.00 | Taking down existing worn out/old/broken ACSR conductors of any size and length at any position from LT poles and supply, fixing and stretching new ACSR conductors of any size and type for over head LT poles including binding at site to insulator with suitable size of binding wire etc complete all as specified and directed by Engr in charge. Location :- CVD | 1 | Qtl | 12,999 ₹12,999 | 10,000 ₹10,000 | 13,000 ₹13,000 | 500 ₹500 Lowest | 8,000 ₹8,000 | 18,000 ₹18,000 | 500 ₹500 Lowest |
| 7.00 | Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by Engg-in-Charge.
Note: (a) 11 KV HT cable & joints shall be measured and paid for separately under respective items of schedule.
(b) Retrieved old serviceable cable cover will be laid in trenches for cable protection. If extra PCC cover and sand required at site shall be measured and paid separately under respective items of BOQs.
(c) Excavation and earth work will be measured and paid for separately under respective items of schedule. | 26 | Each Job | 8,900 ₹2,31,400 | 6,000 ₹1,56,000 | 4,000 ₹1,04,000 Lowest | 5,000 ₹1,30,000 | 5,000 ₹1,30,000 | 5,000 ₹1,30,000 | 5,000 ₹1,30,000 |
| 8.00 | All as per item Ser No 7 here in before but 1100 Volt LT cables complete all as specified and directed by Engg-in-Charge. | 66 | Each Job | 6,800 ₹4,48,800 | 6,000 ₹3,96,000 | 4,000 ₹2,64,000 Lowest | 5,000 ₹3,30,000 | 5,000 ₹3,30,000 | 4,000 ₹2,64,000 Lowest | 5,000 ₹3,30,000 |
| 9.00 | Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks/cable covers of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks/cable covers as required complete all as specified and directed by Engg-in-Charge.
Note: (a) 1100 Volt LT cable & joints shall be measured and paid for separately under respective items of schedule.
(b) Retrieved old serviceable bricks/cable covers will be laid in trenches for cable protection. If extra bricks/PCC cable cover and sand required at site shall be measured and paid separately under respective items of BOQs.
(c) Excavation and earth work will be measured and paid for separately under respective items of schedule. | 150 | RM | 99 ₹14,850 | 150 ₹22,500 | 100 ₹15,000 | 100 ₹15,000 | 500 ₹75,000 | 80 ₹12,000 Lowest | 500 ₹75,000 |
| 10.00 | All as per item Ser No 9 here in before but 11000 Volt HT cables complete all as specified and directed by Engg-in-Charge. | 150 | RM | 99 ₹14,850 | 200 ₹30,000 | 100 ₹15,000 | 100 ₹15,000 | 500 ₹75,000 | 80 ₹12,000 Lowest | 500 ₹75,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
23 Jun 2025, 6:00 pmClosed
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT-10
REPAIR AND MAINTENANCE OF 11 .415KV DAMAGED CABLE AND ELECTRIC BREAKDOWN INCLUDING FAULT DETECTION LOCALIZATION RECTIFICATION WORKS IN 11 .415 KV UNDERGROUND CABLE NETWORK OVER HEAD LINES AND LT PANELS AT CVD PIRU VIHAR DIPAC HQ TG VIKRAM BATR
2025_MES_709828_1
GE ELECT/D-18/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹98,000
Yes
30 Aug 2025
23 May 2025
25 Jun 2025
23 May 2025
23 Jun 2025
16 Jun 2025
Amount
M&L for Earthing in replacement with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanized ironsides complete all as specified, including testing and commissioning complete all as specified and directed by Engg-in-Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Decarbunizing/cleaning complete outgoing/Incoming LT Air Circuit Breaker circuit of size 800/1000/1200 Amps ,srpring , arcing surfaces, 3 phase, cleaning with CTC and ensure proper decarburizing, re-fixing the same tightening the nuts, bolts thimbles for incoming and outgoing system complete, as specified and directed, rate quoted is inclusive of spring & cotton waste provided by contractor complete all as specified and directed by Engg-in-Charge.
S&F in replacement of UNSV MCCBs of capacity 400 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by Engg-in-Charge.
M&L for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamel paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters complete all as specified and directed by Engg-in-Charge.
All as per item No 04 above but of approx size upto 1.90 Sqm complete all as specified and directed by Engg-in-Charge.
Taking down existing worn out/old/broken ACSR conductors of any size and length at any position from LT poles and supply, fixing and stretching new ACSR conductors of any size and type for over head LT poles including binding at site to insulator with suitable size of binding wire etc complete all as specified and directed by Engr in charge. Location :- CVD
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by Engg-in-Charge. Note: (a) 11 KV HT cable & joints shall be measured and paid for separately under respective items of schedule. (b) Retrieved old serviceable cable cover will be laid in trenches for cable protection. If extra PCC cover and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for separately under respective items of schedule.
All as per item Ser No 7 here in before but 1100 Volt LT cables complete all as specified and directed by Engg-in-Charge.
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks/cable covers of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks/cable covers as required complete all as specified and directed by Engg-in-Charge. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for separately under respective items of schedule. (b) Retrieved old serviceable bricks/cable covers will be laid in trenches for cable protection. If extra bricks/PCC cable cover and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for separately under respective items of schedule.
All as per item Ser No 9 here in before but 11000 Volt HT cables complete all as specified and directed by Engg-in-Charge.
M&L for disconnecting faulty/burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap, relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as specified and directed by Engg-in-Charge.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor incl testing and commissioning complete all as specified and directed by Engg-in-Charge for cable of following size :-
95 Sqmm 3 core.
120 sqmm 3 core
150 sqmm 3 core.
185 Sqmm, 3 core.
240 Sqmm 3 core.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor incl testing and commissioning complete all as specified and directed by Engg-in-Charge for cable of following size :-
95 Sqmm 3 core.
120 sqmm 3 core
150 sqmm 3 core.
185 Sqmm, 3 core.
240 Sqmm 3 core.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor incl testing and commissioning complete all as specified and directed by Engg-in-Charge cable of following size :-
95 Sqmm 3 core.
120 sqmm 3 core
150 sqmm 3 core.
185 Sqmm, 3 core.
240 Sqmm 3 core.
Supply, fixing and testing, commissioning of straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armored heavy duty aluminum conductor 1100 Volts grade complete all as specified and directed by Engg-in-Charge for the following sizes:-
16 -25 sqmm x 4 core
35-50 sqmm x 3.5 core
70-95 sqmm x 3.5 core
120-150 Sqmm x 3.5 core
185-240 Sqmm x 3.5 core
300-400 Sqmm x 3.5 core
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying/taking up/ taking down of UG cables and getting out and leveling of bottom surface to required level complete all as specified and directed by Engineer- in- Charge.
Returning filling in, including spreading, leveling, Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge.
Removing excavated material (i.e. soil) from site to a distance n.exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer- in- Charge.
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of UG cables complete all as specified and directed by Engineer- in- Charge.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 of size 300mmx 180mm x 40mm complete all as specified and directed by Engineer- in- Charge.
Laying only old cable cover obtained during excavation complete all as specified and directed by Engineer- in- Charge.
Supply and laying of sub class B bricks having minimum compressive strength 75Kg/Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge.
Laying oly old bricks obtained during excavation complete all as specified and directed by Engineer- in- Charge.
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed by Engineer- in- Charge of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
95 sqmm 3 core.
120 sqmm 3 core.
150 sqmm 3 core.
185 sqmm 3 core
240 sqmm 3 core
Supply, laying, jointing, testing and commissioning in replacement LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armored, with multistranded aluminum conductors, IS-1554 marked, laid in trenches complete all as specified and directed by Engineer- in- Charge of the following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
16 Sqmm 4 core
25 Sqmm 4 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 80 to 100 mm bore and making good both ends complete all as specified and directed by Engineer- in- Charge.
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by Engineer- in- Charge of following bore sizes:-
S&F cable route indicator made of RCC (Nominal Mix) type B0 1:2:4 (12.5mm graded stone aggregate) with 8mm TMT Bar 150mm c/c of size 1m height X 60cm wide X 10cm thick tapered on top, visible above ground, duly painted with synthetic enamel paint of yellow colour base and letters with black paint. The description for writing for HT cable 33 /11KV complete all as specified and directed by Engineer- in- Charge Note : Rate for PCC 1:3:6 for foundation (min size 0.8mx0.3mx0.3m) with aggregate size 20mm including necessary excavation & earthwork for cable route indicator is deemed to be included in the quoted rates.
M&L for cutting and removing grass, vegetation bushes etc from surrounding 4 pole/6 pole, Transformer, LT panels, in and outside area of HT/LT Sub stn and removing all rubbish to a distance not exceeding 50 m complete all as specified and directed by Engineer- in- Charge
M&L for testing, setting & co-ordination of relay parameters consideration with incoming and outgoing feeders including following tests and setting complete all as specified and directed by Engineer- in- Charge with detalis mentioned as under :- (i) testing of following relays of control panel with secondary injection kit checking and programming of realy (ii) OVER CURRENT IDMT with pick upsetting ,TMS ,CTR <fault current ,Operating time setting (iii) Over current IDMT with I>>,Td,I>>>,Td setting (iv) Earth fault DMT IDMT with pick up setting ,TMS,CTR fault current operating time setting (v) Earth fault DMT with I>>,Td,I>>>,Td setting
M&L for re-painting of existing transformer/RMU GI fencing of any sizes with apply of 2 coats of aluminum paint including rubbing with wire brush/emery paper to fencing and angle irons, at different location after disconnecting of HT supply from incoming and LT supply complete all as specified and directed by Engineer- in- Charge.
M&L for spreading of stone aggregate of nominal size not more than 25mm under 4/6 pole HT structure /surrounding area of outdoor RMU manually without damaging any equipments, cable or parts , spreading & leveling of finished gravel uniformly in layers nexc. 15 cm thick watered and rammed to true surface complete all as specified and directed by Engineer- in- Charge.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv (size 2x1m) for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety complete all as specified and directed by Engineer- in- Charge.
S&F in replacement of Air circuit breaker (ACB) 4 pole 1000 Amps 65 KA with Microprocessor release, manual drawout Adjustable type including dismantling & taking out old unserviceable ACB from panels & fabrication works to BUS bar for proper fitting complete all as specified and directed by Engineer- in- Charge.
Platform :- M&L for Brick Masonry (Using sub class 'B' Brick) platform of size 2.2 m x 2.2 m x 1. m height, built in CM 1:4 complete with excavation & earth work, PCC 1:4:8 type D-2 in foundation 150 mm thick, 15 mm thick rendering in CM 1:6 on sides and top of the brick work, upto 150 mm below ground level, supply and fixing of 02 Nos MS Channels of suitable size for balancing of Transformer embedded in PCC 1:2:4 type B-1 up to 100 mm Thick RCC 1:3:6 with 10 mm steel bar includding 20 mm graded aggregate, including provn of stair case on one side complete all as specified and directed by Engineer- in- Charge.
M&L in replacement Retro Reflective installation sign boards of size 5 feet x 4 feet fabricated out of 16 gauge MS sheet ,framed with stainless steel heavy duty pipe of size 50 mm bore duly welded/riveted with MS square pipe of size 25 mm x 25 mm at height 2.00 meter above ground level on stainless steel heavy duty pipe of size 50 mm bore embaded 60 CM in PCC 1:2:4 type B 1 block of size 45cm x 45cm x 60cm including necessary excavation and earth work .The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The wiriting matter i.e. details of Substation, location, tele No etc. will be in English language on both sides with reflective adhesive painter tapes complete all as directed and specified by Engineer -in-charge.
Boring of hole under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine suitable for HDPE pipe of 150 mm dia complete all as directed and specified by Engineer -in-charge. Note:- The quoted rates shall be deemed to include for taking all permissions prior to execution of trenchless work and making good all the damages if any.
S&F High density polyethlene pipes of size 150 mm dia (HDPE) of pressure rating 10 kg/cm2 laid in trenches/ducts/bore holes for road crossing/ hard standing etc for laying HT cables complete all as directed and specified by Engineer -in-charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
DS CONSTRUCTION (BID ID -3333217)
Rajindera Enterprises (BID ID -3328591)
ALLIED CONSTRUCTION (BID ID -3334142)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3333885)
MV Engineers And Contractors (BID ID -3326110)
Vijay Electricals (BID ID -3333677)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .