Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | ₹21.8 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹25.0 L+₹3.2 L (14.6%)Rejected-Finance | ₹25.0 L+₹3.2 L (14.6%) | L2 | Rejected-Finance HIGHER |
Tender Value
₹20.9 L
EMD Value
₹41,900
Closing Date
27 Jan 2020, 5:00 pmClosed
Makhan Lal Goyal, EE
Executive Engineer, Provincial Division, PWD B and R Br., Panchkula
DNIT FOR Special Repair of Old P.H.C. Building (Steel Structure) at Morni in Panchkula Distt.
2020_HRY_115599_1
PWD/CHD/PKL/16788
Open Tender
Construction Works
Works
90 days
Panchkula
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
Yes
E.E., Provincial Division, PWD B and R Br.,
₹41,900
Yes
24 Sept 2020
18 Jan 2020
28 Jan 2020
18 Jan 2020
27 Jan 2020
18 Jan 2020
Amount
Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction, including disposal of all surplus soil as directed within a lead of 30 Mtrs. (HSR 6.6)
Cement concrete 1:8:16 with stone aggregate 40mm nominal size in foundation and plinth. (HSR 10.28).
Providing and laying 60mm thick interlocking paver blocks of all shapes and colours in design mix cement M-35 over a bed of 30mm thick fine sand complete in all respect.(HSR 10.158).
First class brick laid in cement sand mortar 1:4 in foundation and plinth. (HSR.11.4)
Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183. Density 16 kg/m³, 50 mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire complete (DSR 12.35)
Corrugated G.I. sheet roofing 0.80 mm thick fixed with galvanised iron ‘J’ or ‘L’ hooks, 10 mm dia G.I. limpet and bitumen washers complete, excluding the cost of purlins, rafters and trusses . (HSR.13.18)
Providing and fixing false ceiling with grooves with 12mm to 15mm thick, 600mm x 600mm best quality mineral fiber tiles of approved make fixed on M.S. steel rubbers frame i/c cost of screws angles, cleats, rawel plugs, with taping and painting etc. complete in all respects as approved by the Engineer-in-Charge. (HSR.13.93)
Base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling.(HSR.14.1)
Conglomerate floor 40 mm thick cement concrete topping 1:2:4. (HSR.14.9)
Providing and fixing vitrified tiles of size 600 x 600mm of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJA-RIA, SOMANI, ORIENT, JOHNSONS & RAK..(HSR.14.89)
Providing and fixing ceramic tiles/antiskid tiles of size 400mm x 400mm or above size of approved make in flooring, laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles Note:- Tile shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJA-RIA, SOMANI, ORIENT, JOHNSONS. (HSR.14.91)
Providing and fixing Ist quality ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including pointing in white cement mixed with pigment of matching shades complete (HSR.14.92 b) Size of ceramic glazed tiles 300mm x 450mm.
12mm thick cement Plaster 1:4. (HSR 15.5).
Applying priming coat with metal primer on new steel or iron work including preparation of surface.(HSR 16.9).
Painting two coats on iron sheets with roofing red ready-mixed paint on new work to give an even shade.. (HSR.16.20)
Preparation of plastered or concrete surfaces for painting, including sand papering the surface, applying one coat of linseed oil and filling with approved quality filler, consisting of white lead, linseed oil, varnish and chalk mitti including finishing surface to the required finish, complete. (HSR.16.24)
Chowkats of commercial hard wood such as hollock, champ, chikassy and chaplash etc., (Non-coniferous timber other than teak conforming to I.S. specification no.1003 kiln seasoned, of doors and windows including iron hold fasts, corner straps, scraws, bolts for hold fasts, etc., complete fixed in position. (HSR 17.12)
Supplying and fixing hydraulic door closer, I.S.I.mark, with necessary screws, etc., complete. (HSR 17.82(c).I.S.I. designation No.III (size of door 851 mm to 1000 mm )
Factory manufactured panelled door or glazed window, shutters of commercial hard wood, such as hollock, champ,chikrassy and chaplash,etc.,(non-coniferous timber other than teak,conforming to I.S.specification No.1003,kiln-seasoned),with 100 mm wide verticle styles, 150 mm wide lock rail, 200 mm wide bottom rail and 100 mm wide other rails, with panels of 15 mm thick, tongued and grooved of commercial hard wood and including cost of iron hinges, screws, chocks /cleats, stops,nails etc., complete, fixed in position (excluding the cost of any fittings,other than specified above,but including labour for fixing the same in position). . (HSR 17.90 b ) 35 mm thick
Wrought iron and mild steel (using angles, flats, square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors open able or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR.18.12)
Providing and fixing Gyptech 70 mm thick cement board partition having 50 mm G.I frame of 0.5 mm thickness. G.I frame floor channel size 50 mm wide and having flanges of 30 mm both side fixed to floor horizontally with 35 x 8 mm steel screw and PVC sleeves. Then 48 mm wide having flanges of 25 mm G.I stud of thickness 0.5 mm both side is screwed with floor channel at interval of 600 mm. After that Cement board of 10 mm is screwed with Gypsum steel Screw 25 x 6 mm on the G.I stud both sides. 48 kg/ m3 density of 50 mm thickness rockwool should be infilled between the boards for getting better sound insulation complete in all respect as per entire satisfaction of Engineer-in-Charge.(N.S)
Providing and fixing metal frame wall panelling which includes 10 mm thick bison/Guptech cement board screw fixed to stud 48 mm (0.5 mm thick having one flange of 34 mm and another flange of 36 mm made made of G.I steel) placed at 610 c.c in floor channel (0.5 mm thick hacing equal flanges of 25 mm made of G.I steel) fixed to the floor and ceiling cavity between the wall & the cement board can be filled with 48 kg x 50 mm rock wool for better sound & thermal insulation ccomplete in all respect as per entire satisfaction of Engineer-in-Charge.(N.S)
Excavation of trenches in streets, lanes or in open areas for storm sewer, sewers running by gravity and manholes to full depths as shown in drawings including shoring, timbering of poling boards, frame system type, dressing to correct sections and dimensions, according to templates and levels, dewatering, provision for diversion of traffic, cutting trees and bushes, etc. night signals profiles, pegs, sight rails, boning rods, crossing over trenches for access to the houses, watching fencing etc. fixing and maintenance of caution board refilling of trenches, watering of refill, in 15 cm layers ramming and restoration of unmetalled or unpaved surface to original condition and removal of surplus soil, from site of work, upto a lead of 1 Km in oridnary soil. (a) for depths excavation not exceeding 3 metres below ground level. [HSR 6.10 (a)].
Cement concrete 1:8:16 with stone aggregate 40mm nominal size in foundation and plinth. (HSR 10.28).
Providing for laying, jointing, fixing and testing G.I. (Medium class "B" type of Tata & Jindal make) pipe lines and specials tees bends, sockets, elbows etc. inside building and testing etc. complete including cutting threading. Including cost of Special. G.I. specials shall be of Make:- UNIK, TATA, ZOLOTO. (NS) (i) 15 mm internal diameter of pipeline
(ii) 20 mm internal diameter of pipeline
(iii) 25 mm internal diameter of pipeline
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines. [HSR 28.21]. (a) 15 mm internal diameter
(b) 20 mm internal diameter
(c) 25 mm internal diameter
Drilling and Tapping cast iron pipe lines of all diameters and screwing in ferrule and connections-Size of ferrule. [HSR 28.22]. (vi) 40 mm internal diameter of pipeline.
Cutting holes upto 23 cm square through brick work in mud walls for pipes and making good including repointing replastering and finishing according to existing finish where required. [HSR 28.23]. (i) 11.43 cm thickness of walls
(ii) 22.86 cm thickness of walls
Labour for fixing G.I. or W.I. pipe sleeve pieces in holes in walls, floors, and roofs ro(a) 15 mm internal diameter unds pipes including all cutting and wastage. [HSR 28.27].
(b) 20 mm internal diameter
(c) 25 mm internal diameter
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I. pipelines laid in the ground or inside building including cartage from divisional stores or nearest railway station to site of works. (HSR 28.29). (a) 15 mm internal diameter
(b) 20 mm internal diameter
(c) 25 mm internal diameter
Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning, trimming and dressing the trenches to correct alignment and grade as required by the Engineer-In-charge. [HSR 28.47 (a)]. Upto 200 mm internal diameter
JOINTING PLAIN AND REINFORCED CONCRETE PIPES AND SPECIALS OF ALL CLASSES IN TRENCHES USING COLLAR JOINTS JOINTED WITH 1:1 ½ CEMENT SAND MORTAR NEARLY dry heavily caulked into joints AND WITH END DOWELS FILLED WITH 1: 1 ½ CEMENT SAND MORTAR including facing trowelling and finishing the joints and at angle of 45 degree with face of collars keeping the joints wet till cured testing the drain line for leakages and making good for all leakages and defects as laid down in the contract specifications complete with two spigots and jointed to collars and internal diameter of sewer pipe or special being:- (c) 200 mm. (HSR 29.45)
CUTTING PLAIN AND REINFORCED CONCRETE PIPES AND SPECIALS of all classes chipping AND FINISHING THE CUT SURFACE TO A UNIFORM finish to the satisfaction of the Engineer-in-charge. (c) 200 mm (c) 200 mm. (HSR 29.46)
Constructing brick masonry inspection chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent limer mortar 2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2;4 slab 100 mm thick./C.C. topping 50 mm thick with 455 mm x 455 mm 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint coplete as per standard design. (c) Size 600 mm x 900 mm inside (with 455 mm x 455 mm cover and frame light duty singel weighing 20 Kg with R.C.C. slab). [HSR 29.84]. (a) Size 450 mm x 450 mm
(c) Size 600 mm x 900 mm
Constructing brick masonry road gully chamber as per standard drawings (as per sizes given below) including dressing of beds and sides of chamber to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item no 10.6) in foundation, Ist class brick work laid in cement sand mortar, 1:5, 40mm thick cement concrete 1:2:4, topping inside the chamber with a floating coat of 1.5 mm thick neat cement laid in one operation to the topping the entire inner surface of the chamber rendered with neat cement not less than 12 mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1 mm thickleft absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as specified in item no. 29.48 complete and to the requirement of the Engineer-In-charge). (a) Single Road Gully Chamber (i) Size 610 mm x 457 mm x 800 mm. [HSR 29.87 (a) (i)].
CONSTRUCTION OF RECTANGULAR STANDARD BRICK MASONRY MANHOLE CHAMBERS to standard drawings on S.W pipe sewers or other circular pipe sewers upto the required depth in 1.5 CEMENT SAND MORTAR, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium solicate on interior surface where required, reinforced cement concrete slab 180 mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. The rate cover the cost of M.S steel for R.C.C slab Labour for fixing and carriage of C.I manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also includes the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. Sodium silicate shall be supplied free of cost at the stores of Engineer- in-charge. [HSR 29.90 (ii)]. (ii) On 150 mm I/d Pipe sewer (a) For 1.20 Mtrs. depth below ground level
(b) For 1.50 Mtrs. depth below ground level
Providing, lowering, laying, cutting (cut surface to be uniformity finished) jointing with rubber rings marked with IS:5382 and testing of SPIGOT AND SOCKETTED RCC NP2 MARKED WITH IS:458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction to the Engineer -in-charge. (a) 200 mm dia. (HSR 29.93).
Providing SALT GLAZED STONE WARE PIPES GRADE 'A' IN STANDARD LENTH OF 600 MM EACH PIPE MARKED WITH IS;651 and their lowering, cutting, jointing and testing as described in HSR item no. 29.38, 29.39, 29.40 inlcuding the cost of jointing materials as well as carriage, loading, unloading, stacking handling, re-handling etc. complete in all respect to the satisfaction to the Engineer-in-Charge. (b) grade 'A' 150 mm. (HSR 29.95)
Providing and fixing in position best indian make (as approved by the engineer-in-charge European type water closet suite, syphonic type consisting of- (i) VITREOUS CHINAWARE SYPHONIC SUITE WITH 15 LITRES CAPACITY MATCHING CHINAWARE CISTERN and all internal brass fittings COMPLETE WITH ‘P’ or ‘S’ TRAP with or without vent; (as approved by the Engineer-in-charge). (ii) One piece SEAT AND LID IN HOLLOW BLACK OR WHITE PLASTIC fitted with chromium plated hinges and rubber buffers, (to the approval of the Engineer-in-charge) COMPLETE in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS. (b) Double trap syphonic (ii) Single Color. [HSR 30.5 (b) (ii)].
EXTRA OVER item nos. 30.1 to 30.4 and 30.6 FOR PROVIDING AND FIXING 15 LITRES CAPACITY C.I. LOW LEVEL VITREOUS CHINAWARE CISTERN complete with flush bend all other necessary Fittings instead of C.I high level cistern complete with fittings. (i) White. [HSR 30.12 (i)].
EXTRA OVER item nos. 30.3 to 30.6 FOR PROVIDING AND FIXING BEST INDIAN MAKE PLASTIC HYGENIC SEAT with lid complete instead of hollow Black or white plaster seat and lid.(i) White plastic seat (Solid). [HSR 30.13 (i)].
EXTRA FOR providing and fixing 32 MM dia G.I./C.P FLUSH PIPE complete with accessories instead of 32/MM dia galvanized telescopic flush pipe with clips (as required by the Engineer-in-charge). (i) 32 mm dia G.I. flush pipe. [HSR 30.15 (i)].
Providing & Fixing in position best indian make (ordinary) lavatory suites consisting of:- (v) Size 560 mm x 450 mm with one no. tap. [HSR 30.41(v)].
PROVIDING AND FIXING IN POSITION 32 MM DIA G.I. WASTE PIPE EMBEDDED IN WALL or lead waste pipe (weighing 3.47 kg. per metre and 2.8 mm thick) upto floor Level including cost of wipped solder joint etc., complete (as required by the Engineer-in-charge). [HSR 30.48].
Providing and fixing in position best Indian make chromium Plated brass Bottle trap 32 mm dia metre. complete (as required by the Engineer-in-charge). [HSR 30.50]
Providing and fixing in position best quality Stainless Steel Sinks with Complete fittings as fully described in item No. 30.51. (a) 600 mm x 450 mm x 200 mm. [HSR 30.53 (a)].
Providing and fixing 40 mm I/D Stainless Steel waste pipe embedded in walls or lead waste pipe weighing 4.46 Kg./metre and 3.0 mm thick upto floor level as required by the Engineer-in-charge including cost of union and plumber joint. (HSR 30.62)
Providing and fixing 40 mm i/d chromium plated brass trap with chromium plated bra pipe to wall with wall flange, complete (as per requirement of the Engineer-in-charge) for use with sinks. (a) with Bottle Trap (indian make). [HSR 30.63 (a)].
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE PAPER HOLDERS FIXED INTO wall with C.P Brass screws complete in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. (a) C.P. Brass. [HSR 30.67 (a)].
Providing and fixing in position best Indian make towel rails fixed in with raw slugs embedded in walls with C.P. Brass screws, complete in all respect including cutting and making goods the walls etc.: (a) 25 mm dia, C.P. Brass adjustable. (i) 750 mm long. [HSR 30.68 (a)]
Providing and fixing in position glass shelf fixed in with rawl plugs with C.P. Brass screws, complete including cutting and making good the walls etc. (a) with C.P. Brass brackets and guard rail. (i) 600mm x 125 mm . [HSR 30.69 (a) (i)].
Providing and fixing in position best Indian make Soap dish fixed into wall with C.P. brass screws and complete in all respects including cutting and making goods the walls etc. (a) C.P. Brass (i) Soap dish Large. [HSR 30.70 (a) (i)].
Providing & fixing in position best Indian make bevelled edge 5.5 mm thick mirror mounted on absetos sheet ground fixed in postion by means of 4 Nos. chromium plated brass screws and washers over rubbers washers and rawl plug embeded in the wall or chromium plated brass clamps with C.P. brass screws (as required by the engineer-in-charge) complete including cutting and making good the walls etc. (a) Indian Make (i) 600 mm x 450 mm. [HSR 30.71 (a) (i)].
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE COAT AND HAT HOOKS fixed into wall with C.P Brass screws and rawl plugs etc. COMPLETE INCLUDING CUTTING AND MAKING GOOD THE WALLS ETC. (a) C.P. Brass. (ii) Two Way. [HSR 30.73 (a) (ii)].
Providing and fixing in position super quality 65 mm i/d opening C.P brass dome type hinged grating weighing about 750 gms fixed in cement mortar 1:2 complete in all respects (as required by the Engineer-in-charge). [HSR 30.74].
Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-charge). [HSR 30.75]. (a) Bib cock long body.
Providing & fixing in position C.P. brass stop cock (as approved by the engineer-in-charge). (a) 15 mm Stop cock. (ii) Concealed stop cock with flange. [HSR 30.76 (a) (ii)].
Providing and fixing C.P. brass liquid soap container of best quality (as required by the Engineer-in-charge). (HSR 30.77).
Providing and fixing in position best Indian make flexible tube connection. (b) C.P. Brass (iii) 15mm x 450 mm. [HSR 30.82 (b) (iii)].
Providing and fixing in position H.C.I. Soil waste vent or antisyphonage pipes to I.S.I. specifications of E.L.C. manufacture or of any other reputed firm including cutting and wastage etc. and cutting holes in walls, roofs or floor etc. and making good to its original condition but excluding cost of lead jointing. (HSR 30.84) (a) 100 mm internal diameter.
(b) 75 mm internal diameter.
Providing and fixing in position C.I. Gully trap cover weighing approximately 7.26 Kg. and frame for gully trap chamber clear opening size 300 mm x 300 mm and out side size 330 mm x 330 mm including painting the exposed surfaces with 3 coats of black bitumastic superior paint of approved manufacture etc. (HSR 30.85).
Providing lead caulked joints to H.C.I. pipes and specials confirming to I.S.I. specificationsof E.L.C. manufacture or any other reputed firm including cost of lead yarn, fuel and tools etc. (HSR 30.87). (a) 100 mm internal dia meter. (1.13 Kg)
(b) 75 mm internal dia meter. (0.91 Kg)
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S. flat not less than 5 mm of the approved design for fixing C.I. soil waste vent or anti pipes to walls complete in all respects. (a) for 100 mm interal diameter pipes. (HSR 30.88). (a) for 100 mm interal diameter pipes.
(b) for 75 mm interal diameter pipes.
Providing & Fixing H.C.I. floor traps I.S.I. marked of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors, etc. minimum depth of water should be 50 mm with a minimum seal of 50 mm. (b) with 75 mm i/d outlet. [HSR 30.89 (b)].
Providing and fixing in position H.C.I. specials for soils, waste, vent or anti-syphonage pipes to I.S.I. marked including cutting and waste etc. cutting holes in walls roofs or floors etc., and making good to its original condition but excluding cost of lead jointing. (HSR 30.91). (a) For 100 mm dia pipes (1) Heal rest bend
(2) Double Junction with door 100 mm x 100 mm x 100 mm x 100 mm
(13) Bend with Door
(14) Bend Plain
(16) Cowls
(17) Door piece
(22) Collars
(b) For 75 mm dia pipes (1) Heal rest bend
(3) Double Junction with door 75 mm x 75 mm x 75 mm x 75 mm
(13) Bend with Door
(14) Bend Plain
(16) Door piece
(17) Cowls
(18) Collars
Providing and fixing in position automatic brass ball valves in tanks. (b) With Plastic Ball (ii) 20 mm internal diameter. [HSR 30.110 (b) (ii)].
Providing & Fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150 mm x 150 mm cast iron cover weighing approximately 7.26 Kg. and frame clear opening 300 mm x 300 mm and outside size 330 mm x 330 mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:2:4, in coping black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150 mm with a minimum seal 50 mm. (b) 100 internal diameter H.C.I. gull trap. [HSR 30.114 (b)].
Providing and Fixing HDPE WATER STORAGE TANKS of Sintex, Diplast, O.K. Supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow and scour provisions with suitable plug on scour pipe including cost of nipples, washers flages for connections in tanks complete in all respects to the satisfaction to the Engineer-in-Charge. [HSR 30.119]. 500 Ltrs. Capacity Water Tank
E.I work:- ( c ) Moulded case Circuit breakers. (HSR.31.12) Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 100 Amp to 220 Amp..415 V,10 KA 3-phase. (HSR.31.12 c (ii)
(L) Miniature Circuit Breaker and Isolator. (HSR.31.17) Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SP MCB of 9 KA breaking capacity 6 Amp.. to 32 Amp..(HSR.31.17a) (ii))
TP MCB of 9 KA breaking capacity 40 Amp.. to 63 Amp.. (HSR.31.17(a) (iii))
TPN MCB of 9 KA breaking capacity 40 Amp.. to 63 Amp. (HSR.31.17(a) (iii))
(M) Supply and erection of Fittings and Accessories. (HSR.31.18) Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point. (HSR.31.18 (xxiv))
(O) Erection and carriage of fans. (HSR.31.2) Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.(HSR.31.20 (i) )
(Q) Earthing (HSR.31.22) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required . (HSR.31.22(i))
Extra for using salt and charcoal / coke for pipe earth electrode as required. (HSR.31.22(ii))
Supply and erection of 20 mm x 3 mm thick G.I. tape fixed with suitable G.I. stapples of same size. (HSR.31.22(xix))
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections. (HSR.31.26) 10 Sq. mm 2 Core Armoured Cable. (HSR.31.26 (iv) )
25 Sq. mm 4 Core Armoured Cable. (HSR.31.26 (xIi)
( T ) Street Light. (HSR.31.30) Supply and erection of 32 mm dia meter 1.5 metre long bracket ( B-Class ) making an angle of 10 to 15 degree with horizontal plane for mounting street light fitting fixing of GI bracket on wall with 2 Nos. , 32 mm x 3 mm thick MS clAmp.s including the cost of cutting , welding of GI pipe complete with cement sand mixture , bolts and nuts etc. including necessary connections . (HSR.31.30 (III) ( xv )
(A) PVC Insulated wiring in recessed conduit. (HSR.31.36) Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe. Fan Point - Medium . (HSR.31.36)
Fan Point- Long. (HSR.31.36)
Light Point - Medium. (HSR.31.36)
Light Point- Long. (HSR.31.36)
3 pin 15 Amp. plug point including earthing the 3 rd. pin etc.with 4 sq mm PVC insulated copper conductor cable - Long point. (HSR.31.36 (viii) c)
Call bell point including M.S Box of size 180mmx100mmx60mm deep for call bell - Long point (HSR.31.36 (vi) c)
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. (HSR.31.40) Size 1.5 sqmm (3 / 0.81mm).(HSR.31.40 (i))
Size 2.50 sqmm (3 / 1.05mm). (HSR.31.40 (ii))
Size 4 sqmm (7 / 0.85mm). (HSR.31.40 (iii))
Size 16 sqmm (7 / 1.70mm) (HSR. 31.40 (vi))
Supply and erection of double door sheet steel enclosures distribution boards suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material requared complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work.(HSR.31.41) 4-way, TP & N (Horizontal) (8+12) (HSR.31.41 (iv))
4-way, TP & N (Vertical) (8+12) (HSR.31.41 (vi))
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. (HSR.31.44) 25 mm dia (HSR.31.44(b))
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect. (HSR.31.56) 10 Amp.. 1 way switch
20 Amp.. Switch
10 Amp.. socket
16 Amp.. socket
Fan regulator
Blanking Plate
Pdg. and fixing GI concealed sheet metal boxes inner and outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material requied to complete the job in all respect. (HSR.31.57) 1 & 2 module
6 Modules
12 Modules
S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 Mtr. Below ground level including digging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in charge of work. (HSR.31.67) HDPE 63/50 mm outer dia / inner dia
NS Items LED Downligter 15W Ultra slim make Crompton
Ceiling Fan 48” make Crompton
S/E of LED Street light fitting 45W complete in all respect.
Jawal Singh
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .