Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹41.9 L+₹2.6 L (6.49%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹42.4 L+₹3.1 L (7.85%)Rejected-AOC 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹44.3 L+₹4.9 L (12.6%)Rejected-AOC | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹45.7 L+₹6.3 L (16.1%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L5 | Rejected-AOC Not being L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
16 Aug 2021, 6:00 pmClosed
GARRISON ENGINEER UTILITY SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIRS/ RENEWAL OF LT UG CABLE, LT PANEL BOARD AND ALLIED WORKS AT ZONE II A AND II D AND CERTAIN OTHER AREA UNDER AGE E/M NO -II OF GE (U) SECUNDERABAD
2021_MES_461583_1
GE(U)/SEC/TOKEN/30 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
7 documents required · 7 mandatory
₹500
GE UTILITY SECUNDERABAD
₹96,000
Yes
18 Sept 2021
20 Jul 2021
18 Aug 2021
20 Jul 2021
16 Aug 2021
4 Aug 2021
Amount
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections including Pipes, Bricks, etc. of any descriptions, laying in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed.
Supply and lay in trenches/fixed to walls/poles etc connecting buy using lugs, nut bolts and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 2 Core 10 Sqmm complete all as directed. Make : Havells/Finolex/POLYCAB/KEI/Gloster Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item No:02 above but 4 Core 10 Sqmm
All as per item No:02 above but 4 Core 16 Sqmm
All as per item No:02 above but 4 Core 25 Sqmm
All as per item No:02 above but 3.5 Core 50 Sqmm
All as per item No:02 above but 3.5 Core 70 Sqmm
All as per item No:02 above but 3.5 Core 95 Sqmm
All as per item No:02 above but 3.5 Core 120 Sqmm
All as per item No:02 above but 3.5 Core 150 Sqmm
All as per item No:02 above but 3.5 Core 240 Sqmm
All as per item No:02 above but 3.5 Core 300 Sqmm
All as per item No:02 above but 3.5 Core 400 Sqmm
Relaying of LT cable of size 10 sqmm to 120 Sqmm 2/3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: (i) Earth work, spreading of riddled earth, brick protection, Lt Joints shall be measured and paid separately under Relevent Item. (ii) Retrived serviceable bricks/ PCC cover shall be reused under relevent item.
Supply and lay GI tubing, 50 mm bore light grade for cable protection at road crossing / on poles/ fixing of post top lantren and tubing sealed at both ends after laying the cables including necessary clamps made out of MS flat complete all as directed by Engineer-in-Charge.
All as per item No:15 above but 40 mm bore
All as per item No:15 above but 80 mm bore
Refixing of serviceable GI pipe of any size as retrived against item no 1 including necessary clamps, complete all as specified and directed
Dismantling of pole coping on any size for removing of cable /pipe as required at site and redoing the same by using PCC(1:3:6 C2 by using 20 mm graded gravel) of size 60CMX60CM X30CM complete including removing of dismentaled material complete all as specified and directed.
Dismantling of pole coping on any size for removing of cable /pipe as required at site and redoing the same by using PCC(1:3:6 C2 by using 20 mm graded gravel) of size 45CMX45CM X30CM complete including removing of dismentaled material complete all as specified and directed.
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete including taking out old unserviceable one all as specifide and directed. Note : Quoted rate incusive of disconnection and refixing of cable after taking proper shut down
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmm complete including taking out old unserviceable one all as specifide and directed. Note : Quoted rate incusive of disconnection and refixing of cable after taking proper shut down
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 sqmm to 400 sqmm complete including taking out old unserviceable one all as specifide and directed. Note : Quoted rate incusive of disconnection and refixing of cable after taking proper shut down
Excavation in trenches not exc 1.5 mtr wide and n.exc 1.5 mtr in deep and getting out in Hard/Dense soil laying of cables etc.
Returning filling in including spreading, leveling watering and well ramming in layers n.exc 25cm thick using excavated soil
Removing excavated surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above from the starting point
M&L for brick protection cover of old size bricks common burnt clay building bricks sub class ’B’ of size 220 X 110 X 70 mm laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exceeding 10 mm complete all as specified.
Spreading riddled earth (after preparation of excavated earth) in Cable duct for cushioning of cable laid in trenches complete all as directed by Engineer-in-Charge. Note:- Punned thickness 18 CM (6.25 Cm below cale and 11.75 cm above cale) will be measured for payment purpose. The earth removed during excavation to be used as rddled earth after crushing and sieving. Quoted rate inclusive of all arrangement as mentioned.
Laying only old Brick in trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 1 here-in-before), complete all as directed.
S&F galvasised steel strip 32X6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. The earting pit cover should be factorty built ( size TOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch ) made of heavy duty Polypropylene complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL/TRUE POWER
M&L preparing Steel and Iron Surfaces of any description, over 100mm width or girth and applying One Coats of Synthetic Enamel Paint (First quality) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 10 to 25 Sqmm 4 core including all jointing materials complete all as specified and directed complete all as specified and directed. Note : Quoted rate incusive of excavation , disconnection and refixing of cable after Jointing
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 35 to 70 Sqmm 3.5 core including all jointing materials complete all as specified and directed complete all as specified and directed. Note : Quoted rate incusive of excavation , disconnection and refixing of cable after Jointing
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 95 to 120 Sqmm 3.5 core including all jointing materials complete all as specified and directed complete all as specified and directed. Note : Quoted rate incusive of excavation , disconnection and refixing of cable after Jointing
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 150 to 240 Sqmm 3.5 core including all jointing materials complete all as specified and directed complete all as specified and directed. Note : Quoted rate incusive of excavation , disconnection and refixing of cable after Jointing
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, GI pipe of size 50/ 80 mm dia of maximum length 12 meter including jointing materials to carry LT UG cables of size upto300 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed including refilling and making good of disturbed surface. Note : Quoted rate Excluding of GI Pipe 50 / 80 mm dia as required on ground
Supply and Replace Spreader link suitable for MCCB up to 125 Amps after taking proper shutdown in existing panel /feeder pillar box complete all as directed
Supply and Replace Spreader link suitable for MCCB of 160 A to 250 after taking proper shutdown in existing panel /feeder pillar box complete all as directed
Supply and Replace Spreader link suitable for MCCB of 315 A to 400 amps after taking proper shutdown in existing panel /feeder pillar box complete all as directed
Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBs Adjustable thermal magnetic setting of capacity 630 Amps, 4 Pole, 50 KA, 415 Volt including disconnecting/taking out existing old unsv/burnet MCCB complete all as specified and directed. Make : Standard or techno commercial equivalent model in Havells/Standerd/L&T.
Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBs Adjustable thermal magnetic setting of capacity 400 Amps, 4 Pole, 35 KA, 415 Volt including disconnecting/taking out existing old unsv/burnet MCCB complete all as specified and directed. Make : Standard or techno commercial equivalent model in Havells/Standerd/L&T.
Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBs Adjustable thermal magnetic setting of capacity 315 Amps, 4 Pole, 35 KA, 415 Volt including disconnecting/taking out existing old unsv/burnet MCCB complete all as specified and directed. Make : Standard or techno commercial equivalent model in Havells/Standerd/L&T.
All as per item No-43 here in before but of capacity 250 Amps, 4 pole, 25 KA
All as per item No-43 here in before but of capacity 200 Amps, 4 pole, 25 KA
All as per item No-43 here in before but of capacity 160 Amps, 4 pole, 16KA
All as per item No-43 here in before but of capacity 125 Amps, 4 pole, 16 KA
All as per item No-43 here in before but of capacity 100 Amps, 4 pole, 16 KA
All as per item No-43 here in before but of capacity 63 Amps, 4 pole, 16 KA
S&F MCB, 63 Amps, 4 pole, 415 Volts with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned MCB complete all as specified and directed.
All as per item No-50 here in before but of capacity 40 Amps, 4 pole, 415 Volts with breaking capacity 10KA
All as per item No-50 here in before but of capacity 32 Amps, 4 pole, 415 Volts with breaking capacity 10KA
S&F MCB, SPN 10-32 Amps, 415 Volts with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.
All as per item no:43 above but MCCB's 415 volts 3pole 25 KA breaking capacity Adjustable type of 160 Amps Capacity
All as per item no:43 above but MCCB's 415 volts 3pole 16 KA breaking capacity fixed type of 100 Amps Capacity
All as per item no: 43 above but MCCB's 415 volts 3pole 16 KA breaking capacity fixed type of 63 Amps Capacity
M&L for twin core 1100 volt grade aluminium service wire cross sectional area 4.0 Sqmm for connection of light complete all as specified and directed
M&L for twin core 1100 volt grade aluminium service wire cross sectional area 6.0 Sqmm for connection of light complete all as specified and directed
Disconnection existing LT UG cable of any size from pole/Oh line and connect the same to pole after repair or feeder pillar box by using cable glands , lugs etc as required complete all as directed
Cutting the existing road straight by manual, depth and width not less than 0.6 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
S&F MCCB box made of CRCA sheet of 2mm thick size 40X30X20 CM Powder coated Suitable for fixing at Pole including two set of clamps / wall byusing anchor bolt comprising MCCB 63 Amps 16 KA FP WITH BOTH SIDE SPREADER LINK complete all as specified and directed.
S&F MCCB box made of CRCA sheet of 2mm thick size 40X30X20 CM Powder coated Suitable for fixing at Pole including two set of clamps / wall byusing anchor bolt comprising MCCB 100 Amps 16 KA FP WITH BOTH SIDE SPREADER LINK complete all as specified and directed.
S&F MCCB box made of CRCA sheet of 2mm thick size 40X30X20 CM Powder coated Suitable for fixing at Pole including two set of clamps / wall byusing anchor bolt comprising MCCB 125 Amps 16 KA FP WITH BOTH SIDE SPREADER LINK complete all as specified and directed.
Supply and Replace Change over switch 400 amps side handel ONLOAD type 4 pole 415 volt with enclosure . Make: Havells/L&T/Schneider/standerd
Supply and Replace Change over switch 200 amps side handel ONLOAD type 4 pole 415 volt with enclosure . Make: Havells/L&T/Schneider/standerd
Supply and Replace Change over switch 100 amps side handel ONLOAD type 4 pole 415 volt with enclosure . Make: Havells/L&T/Schneider
Supply and Replace Change over switch 63 amps side handel ONLOAD type 4 pole 415 volt with enclosure . Make: Havells/L&T/Schneider/standerd
Supply and Replace Change over switch 630 amps panel mounting front operated ONLOAD type 4 pole 415 volt without enclosure including making necessary arrangements complete all as specified and directed. Make: Havells/L&T/Schneider/standerd
Supply and Replace Change over switch 400 amps panel mounting front operated ONLOAD type 4 pole 415 volt without enclosure including making necessary arrangements complete all as specified and directed . Make: Havells/L&T/Schneider/standerd
Supply and Replace Change over switch 315 amps panel mounting front operated ONLOAD type 4 pole 415 volt without enclosure including making necessary arrangements complete all as specified and directed . Make: Havells/L&T/Schneider/standerd
Supply and Replace Change over switch 250 amps panel mounting front operated ONLOAD type 4 pole 415 volt without enclosure including making necessary arrangements complete all as specified and directed . Make: Havells/L&T/Schneider/standerd
Supply and Replace Change over switch 200 amps panel mounting front operated ONLOAD type 4 pole 415 volt without enclosure including making necessary arrangements complete all as specified and directed . Make: Havells/L&T/Schneider/standerd
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–(Size not less than 0.75mx0.70mx0.3m)
(a) Aluminium bas bar 300amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 200 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 02 NosMake Legrand model no: 420018/ Equivalent from Schinder/L&T/Hagar/Havells Note:(i) All Internal connection between MCCB and Changeover and Bus bar shall be connected by aluminium strip of suitable size and capacity. (ii) All MCCB to be connected with both side Spreader Link. The rate shall deemed to be include in the item rate
M&L for replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including welding, bending cold or hot, drilling holes for hinged, in any shape or size as indicated for valve chamber top cover, 4 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with locking arrangement, mild steel handle, and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Cutting the existing building plinth protection/ Floor by using suitable cutter , depth and width as required for replacement of LTUG Cable of any size /any kind of pipes pipes up to 50 mm dia and making good of disturbed surface shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) to match with the adjoining surface complete all as specified and directed.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–(Size not less than 1.05mx1.6 M x0.4m)
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–(Size not less than 1.05mx1.5 M x0.4m)
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size(proper space shall be provided for working in each compartment), 3 Phase 4 wire system Outdoor type 3.15mm ,double door front and back openeing type sloped canopy(Hood) on top extended 100mm all-around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable up to 400 Sqmm 3.5 Core in and out(panel board shall have sufficent space to accommodate spare cables also if required) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm thik CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size & thickness of angle iron frame(proper mounting shall be done) duly painted and embeded in necessary required quatnity of PCC 1:3:6 type C1, 60cm below ground level and 30cm above ground level including disconnecting all electrical & mechanical connections and taking down old unserviceable and consisting the following provisions:-
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size(proper space shall be provided for working in each compartment), 3 Phase 4 wire system Outdoor type 3.15mm ,double door front and back openeing type sloped canopy(Hood) on top extended 100mm all-around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable up to 400 Sqmm 3.5 Core in and out(panel board shall have sufficent space to accommodate spare cables also if required) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm thik CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on suitable size & thickness of angle iron frame(proper mounting shall be done) duly painted and embeded in necessary required quatnity of PCC 1:3:6 type C1, 60cm below ground level and 30cm above ground level including disconnecting all electrical & mechanical connections and taking down old unserviceable and consisting the following provisions:-
Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out HARD / DENSE soil
Rough Excavation n.exc 1.5 m deep and getting out HARD / DENSE soil
M&Lfor shingle filling in floors or pavings of Gauge 40 to 63 mm, deposited, spread and levelled in layers not exc. 150mm thick, watered and rammed to a True Surface, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays,as in sub base in flooring, finished even etc etc. including Use and Waste of Formwork (if required), complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) as in Side Wall of Cable Duct,for flooring of pump house, complete incuding necessary form work complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 METRE mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
Hardcore of gauge n exc. 63mm, Broken stone n or boulders deposited, spread andevelled in layers n exc. 15cm thick, watered and rammed to a true surface
SUN LIGHT HOUSE
LEOENTERPRISES
Srinivash Engineers
STANDARD AGENCIES
R AND A ASSOCIATES ENGINEERS CONTRACTORS
POWER CONSTRUCTION COMPANY
vvcenterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .