| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹17.8 L+₹32,484.78 (1.86%)Rejected-Finance 430 D DEFENCE COLONY JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹20.5 L+₹3.0 L (17.4%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER |
| Sl No | Description | Qty | Unit | m/s sahu enterprises L1 | JOG CONSTRUCTION L2 | pk enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for Cleaning/removal of blockage of floor traps/nahani traps of 75 mm/100mm bore in kitchen/bathroom/toilets etc up to 1st Manhole including of taking down PVC/Stainless trap grating and refixing the same with white cement with pigment to match the surface as before or any other associated/related complaints not mentioned under this item and will be done as directed by Engr -in-Charge complete all as specified and directed.
Note - : The Traps shall be measured more than one time as per requirment and directed by Engr-in-Charge. | 2,500 | Each Job | 25 ₹62,500 | 12 ₹30,000 Lowest | 50 ₹1,25,000 |
| 2.00 | M&L for Cleaning/removal of blockage of Gully traps up to 1st Manhole of any size and any depth including removing RCC covers and refixing the same as before or any other associated/related complaints not mentioned under this item and will be done as directed by Engr -in-Charge complete all as specified and directed.
Note - : The Gully Trap shall be measured more than one time as per requirment and directed by Engr-in-Charge. | 2,200 | Each Job | 30 ₹66,000 | 20 ₹44,000 Lowest | 60 ₹1,32,000 |
| 3.00 | M&L for Cleaning/removal of blockage of Orissa pattern WC 'P'/'S' traps and making functional up to 1st Manhole or any other associated/related complaints not mentioned under this item and will be done as directed by Engr -in-Charge complete all as specified and directed.
Note - The WC shall be measured more than one time as per requirment and directed by Egnr-in-Charge. | 2,000 | Each Job | 30 ₹60,000 Lowest | 30 ₹60,000 Lowest | 65 ₹1,30,000 |
| 4.00 | M&L for Cleaning/removal of blockage of Europian type WC 'P'/'S' traps and making functional up to 1st Manhole or any other associated/related complaints not mentioned under this item and will be done as directed by Engr -in-Charge complete all as specified and directed.
Note - : The EWC shall be measured more than one time as per requirment and directed by Egnr-in-Charge. | 100 | Each Job | 80 ₹8,000 Lowest | 80 ₹8,000 Lowest | 200 ₹20,000 |
| 5.00 | M&L for Cleaning /removal of blockage up to 300 mm bore SWG/RCC pipes of depth not exc 1.50 mtr using Mechanized/ Mechnical ( through pressure jetting machine) means including removing RCC manhole covers and refixing the same as before complete all as specified and directed.
Note :- Length of pipe will be measured from previous manhole to subsequent manhole in RM for payment purpose after satisfaction of Engr-in- Charge. | 2,450 | RM | 40 ₹98,000 | 30 ₹73,500 Lowest | 35 ₹85,750 |
| 6.00 | M&L for Cleaning /removal of blockage up to 300 mm bore SWG/RCC pipes of depth exc 1.50 mtr but not exc 3.00 mtr using Mechanized/Mechnical ( through pressure jetting machine) means incl removing RCC man hole covers and refixing the same as before complete all as specified and directed.
Note :- Length of pipe will be measured from previous manhole to subsequent manhole in RM for payment purpose after satisfaction of Engr-in- Charge. | 2,200 | RM | 60 ₹1,32,000 | 45 ₹99,000 | 35 ₹77,000 Lowest |
| 7.00 | M&L for Cleaning/removal of blockage up to 300 mm bore SWG/RCC pipes of depth exc 3 mtr but not exc 8.0 mtr using Mechanized/Mechnical ( through pressure jetting machine) means incl removing RCC man hole covers and refixing the same as before complete all as specified and directed.
Note :- Length will be measured from previous manhole to subsquent manhole in RM for payment purpose after satisfaction of Engr-in- Charge. | 800 | RM | 120 ₹96,000 | 120 ₹96,000 | 50 ₹40,000 Lowest |
| 8.00 | M&L for Cleaning/removal of blockage exc 300 mm but n.exc 450 mm bore SWG/RCC pipes of depth exc 3.0 mtr but not exc 8.00 mtr using Mechanized/Mechnical (through pressure jetting machine) means incl removing RCC man hole covers and refixing the same as before complete all as specified and directed.
Note :- Length will be measured from previous manhole to subsequent manhole in RM for payment purpose after satisfaction of Engr-in- Charge. | 80 | RM | 150 ₹12,000 | 150 ₹12,000 | 80 ₹6,400 Lowest |
| 9.00 | M&L for Dewatering/desilting of existing manholes of internal size n exc 0.80mx0.80m depth n exc 1.50m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion) and incl removing RCC manhole Covers and refixing in the same position after cleaning, complete all as specified and directed. | 300 | Each | 110 ₹33,000 | 110 ₹33,000 | 100 ₹30,000 Lowest |
| 10.00 | M&L for Dewatering/desilting of existing manholes of internal size n exc 1.00mx1.00m depth exc 1.50m but n exc 3.00m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion) and incl removing RCC manhole Covers and refixing in the same position after cleaning, complete all as specified and directed. | 200 | Each | 150 ₹30,000 | 150 ₹30,000 | 120 ₹24,000 Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
28 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR TO SEWAGE SYSTEM IN ZONE-III AND ZONE-IV AREA UNDER AGE B/R-II OF GE (I) KANPUR
2025_MES_711762_1
GE(I)/KAN/T-27 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹60,000
Yes
29 Sept 2025
31 May 2025
5 Jul 2025
31 May 2025
28 Jun 2025
14 Jun 2025
Amount
M&L for Cleaning/removal of blockage of floor traps/nahani traps of 75 mm/100mm bore in kitchen/bathroom/toilets etc up to 1st Manhole including of taking down PVC/Stainless trap grating and refixing the same with white cement with pigment to match the surface as before or any other associated/related complaints not mentioned under this item and will be done as directed by Engr -in-Charge complete all as specified and directed. Note - : The Traps shall be measured more than one time as per requirment and directed by Engr-in-Charge.
M&L for Cleaning/removal of blockage of Gully traps up to 1st Manhole of any size and any depth including removing RCC covers and refixing the same as before or any other associated/related complaints not mentioned under this item and will be done as directed by Engr -in-Charge complete all as specified and directed. Note - : The Gully Trap shall be measured more than one time as per requirment and directed by Engr-in-Charge.
M&L for Cleaning/removal of blockage of Orissa pattern WC 'P'/'S' traps and making functional up to 1st Manhole or any other associated/related complaints not mentioned under this item and will be done as directed by Engr -in-Charge complete all as specified and directed. Note - The WC shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
M&L for Cleaning/removal of blockage of Europian type WC 'P'/'S' traps and making functional up to 1st Manhole or any other associated/related complaints not mentioned under this item and will be done as directed by Engr -in-Charge complete all as specified and directed. Note - : The EWC shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
M&L for Cleaning /removal of blockage up to 300 mm bore SWG/RCC pipes of depth not exc 1.50 mtr using Mechanized/ Mechnical ( through pressure jetting machine) means including removing RCC manhole covers and refixing the same as before complete all as specified and directed. Note :- Length of pipe will be measured from previous manhole to subsequent manhole in RM for payment purpose after satisfaction of Engr-in- Charge.
M&L for Cleaning /removal of blockage up to 300 mm bore SWG/RCC pipes of depth exc 1.50 mtr but not exc 3.00 mtr using Mechanized/Mechnical ( through pressure jetting machine) means incl removing RCC man hole covers and refixing the same as before complete all as specified and directed. Note :- Length of pipe will be measured from previous manhole to subsequent manhole in RM for payment purpose after satisfaction of Engr-in- Charge.
M&L for Cleaning/removal of blockage up to 300 mm bore SWG/RCC pipes of depth exc 3 mtr but not exc 8.0 mtr using Mechanized/Mechnical ( through pressure jetting machine) means incl removing RCC man hole covers and refixing the same as before complete all as specified and directed. Note :- Length will be measured from previous manhole to subsquent manhole in RM for payment purpose after satisfaction of Engr-in- Charge.
M&L for Cleaning/removal of blockage exc 300 mm but n.exc 450 mm bore SWG/RCC pipes of depth exc 3.0 mtr but not exc 8.00 mtr using Mechanized/Mechnical (through pressure jetting machine) means incl removing RCC man hole covers and refixing the same as before complete all as specified and directed. Note :- Length will be measured from previous manhole to subsequent manhole in RM for payment purpose after satisfaction of Engr-in- Charge.
M&L for Dewatering/desilting of existing manholes of internal size n exc 0.80mx0.80m depth n exc 1.50m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion) and incl removing RCC manhole Covers and refixing in the same position after cleaning, complete all as specified and directed.
M&L for Dewatering/desilting of existing manholes of internal size n exc 1.00mx1.00m depth exc 1.50m but n exc 3.00m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion) and incl removing RCC manhole Covers and refixing in the same position after cleaning, complete all as specified and directed.
M&L for Dewatering/desilting of existing manholes of internal size n exc 1.50mx1.50m depth exc 3.00 m but n.exc 8.00 m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion) and incl removing RCC manhole Covers and refixing in the same position after cleaning, complete all as specified and directed.
M&L for Dewatering/desilting of existing Septic Tank/Soakage Well incl removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion or using suction pump where ever required up to any depth by working under foul conditions and disposal of the same in out of MoD area,complete all as specified and directed. Note:- The Septic tank/soak well shall be measured more than one time as per requirement and directed by Egnr-in-Charge.
Taking down cement plaster on brick/stone walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, complete all as specified and directed.
Demolition of RCC work of any description and in any position (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Demolition of brick work or stone/boulders masanory built in cement mortar including all quoins, arches, pillars etc, but excluding ashler facing, dressed stone work and precast concrete articals complete all as specified and as directed.
Demolition and breaking up drain pipes 200 mm bore (salt glazed ware, AC or reinforced) set in cement mortar incl demolation of PCC haunching etc, complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 meter in depth for sewage lines including trimming of sides etc, complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and exceeding 1.5m not exceeding 3.00 meter in depth for sewage lines including trimming of sides etc, complete all as specified and directed.
M&L for Plain cement concrete (1:5:10), type E-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L Plain cement concrete (1:3:6), type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes of 200 mm bore including packing under and hunching against the sides of pipes after they are laid and tested complete all as specified and directed.
S&F Reinforced concrete pipes, 200 mm dia class NP-3 , laid and jointed complete with collars complete all as specified and directed.
M&L Brick work with sub Class ‘B’ bricks straight or curved on plan exceeding 6 mm mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L Rendering 15 mm thick on fair face of brick work concrete surface in CM 1:4 finished even and smooth without extra cement with WPC @3% weight of cement constant or manufacturer instruction including necessary scaffolding complete all as specified and directed. (Note WPC Shall be measured separately)
M&L Plain cement concrete (1:2:4), type B-1, (using 20 mm graded stone aggregate) as in surface channels and drains, benching of manholes laid to shape including necessary form works, complete all as specified and directed.
M&L for Extra for forming fair finished drain or channels 30 cm inner girth in cement concrete, using extra cement incl form moulds mittred / stopped end etc complete all as specified and directed.
M&L for Plain cement concrete (1:2:4), type B-1, (using 20 mm graded stone aggregate) as in coping bed plates & other similar works, including necessary form works weathering, slightly rounded angles and theading complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for internal dia of 150 mm bore pipe complete all as specified and directed.
M&L for Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth in soils, complete all as specified and directed.
M&L for Removal excavated material n.exc 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
M&L for MS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed ) not less than 0.9 mm dia complete all as directed and specified.
M&L for Providing pre-cast reinforced cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in manhole covers complete all as specified and directed.
Dismantling of cast iron or reinforced concrete pipes, jointed in cement mortar and taking out of trenches, or fixed to wall if required internal dia 75 to 100mm dia of pipe complete all as specified and directed.
Supplied and fixed CI soil waste & vent pipe in any length with or without ears, with cement joints 100 mm bore laid on walls with MS flat iron clamps with 50x6mm and 16mm dia round bar stay of required shape and size inclduing drilling holes and embedded in CM 1:3 surface finished complete all as specified & directed.
Supplied and fixed CI soil waste & vent centrifugally cast spun pipe in any length with or without ears, with cement joints 75 mm bore laid on walls with MS flat iron clamps with 50x6mm and 16mm dia round bar stay of required shape and size inclduing drilling holes and embedded in CM 1:3 surface finished complete all as specified and directed.
S&F 75 mm dia, PVC (SWR) soil, waste and water drainage pipes single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed.
S&F 110 mm dia , PVC (SWR) soil, waste and water drainage pipes single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed.
S&F 75 mm dia , PVC (SWR) soil, waste and water drainage pipes Double socketed in any length with rubber ring joints, fixed to walls with and including clamps at minimum spacing of 2 m complete all as specified and directed.
S&F 110 mm dia, PVC (SWR) soil, water drainage pipes Double socketed in any length with rubber ring joints, fixed to walls with clamps at minimum spacing of 2 m complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) bends any radius complete all as specified and directed.
S&F in repair 110 mm PVC (SWR) bends any radius complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repair 110 mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) Branch piece, single (single Y) equal or unequal complete all as specified and directed.
S&F 110 mm PVC ( SWR ) vent cowl complete all as specified and directed.
Supplied and fixed CI bend 100 mm bore (any radius) diminishing pieces or tapers (larger bore measured) all as specified and direced.
Supplied and fixed CI bend 75 mm bore (any radius) diminishing pieces or tapers ( arger bore measured all as specified and directed.
Supplied and fixed CI branch pieces, single (equal or unequal ),ordinary or inverted (spigot or socket type ) or with parallel branches 100 mm bore all as specified and directed.
Supplied and fixed CI branch pieces, single (equal or unequal ),ordinary or inverted (spigot or socket type) or with parallel branches 75 mm bore all as specified and directed.
Dismentling floors, hearth or wall tiling including cement morter bedding , removing serviceable tiles to store and rubbish off the premises all as specified and directed .
M&L for 15mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M&L for 400 x 400 mm Non skid ceramic coloured tiles of approved colour & 7 - 8 mm thick as in floors etc; fixed with spacers(Light weight plastic of 3mm size) and epoxy grouting of joints mixed with pigment to match the shade of tiles over screed bed complete all as specified and directed. Note:- Screed bed shall be measured and paid separately under releavant item of BOQ.
S&F in repair 10 Ltr capacity PVC valveless, syphonic action type, flushing cistern low level, white, with inlet ball valve, float and handle including brackets, flushing pipe, 450mm long PVC Connection and connection to trap, and to flushing and making good to floor complete all as specified.
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440 mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding and including trap set complete all as specified and directed.
S&F in repair vitreous chinaware EWC padestal type closet with white seat cover with flat bottom with hinging device including connection to long band "P" trap all as specified and directed.
S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement or as per manufacturer instructions complete all as specified and directed.
S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement or as per manufacturer instructions complete all as specified and directed.
Notes 1 :- (for relevent Items) : If It is not feasible for access of mechanized system for cleaning of line/ MH/ other associated work, same will be executed as per direction of Engr-in-Charge. Decision of inaccessibility of mechanised system shall be decided by Engr -in- Charge and that will be final and binding. Note 2 : All safety precautions will be as per government policies in vogue shall be adhered in to-to. Note 2 : Contractor or his rep shall report daily in the office of Engr-in-Charge, at 0900 Hrs from the date of commencement of work till the completion of the work to attend the sewage related complaints and each complaints shall be attended within a period of 24 hours.
JOG CONSTRUCTION (BID ID -3339443)
pk enterprises (BID ID -3340080)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .