Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.0 CrAccepted-AOC 21 JANAPATH LANE 2ND FLOOR BR ARCADE GHY 78100 | 78100 | ₹65.0 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹67.6 CrRejected-Finance 14 BILASIPARA P O P S BILASIPARA DIST DHUBRI ASSAM PIN 783348 | DHUBRI | ASSAM | 783348 | ₹67.6 Cr | L2 | Rejected-Finance L2 Rate Rejected |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non-Responsive |
| 4 | Rejected-Technical T 3 PARMESHWARI BLDG CHATRIBARI RD GUWAHATI ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | - | - | Rejected-Technical Non-Responsive |
Tender Value
₹50.8 Cr
EMD Value
₹1.0 Cr
Closing Date
8 Jan 2021, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Const. of Assam Judicial Academy at Amingaon, Guwahati (Const. of Administrative Bldg. (G Plus 4), Judicial Officer s Hostel for Male (G Plus 5), Judicial Officer s Hostel for Female (G Plus 5),Gr-IV Residence(G Plus 5), Internal Road and Drain)
2020_PWBNH_19683_1
CE/REC/32/2019/25 Dated Guwahati the 15th Dec 2020
Open Tender
Civil Works - Building
910 days
Amingaon
Please refer Tender documents.
6 documents required · 6 mandatory
₹12,500
Assam State Road Board Maintenance (Road) Fund
₹1.0 Cr
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
12 Aug 2021
18 Dec 2020
11 Jan 2021
18 Dec 2020
8 Jan 2021
18 Dec 2020
2 Jan 2021
Amount
EARTHWORK IN EXCAVATION Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2. 00m below the existing ground level. (a) In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city
Supplying and filling sand gravel in foundation trenches of column footings over slushy soil including local carriage of materials within 8 km pumping out of water, ramming etc. complete for strengthening the bearing capacity of the soil as directed and specified including payment of Forest Royalty and Sales Tax and other duties and taxes as may be necessary.
PLAIN CEMENT CONCRETE WORKS Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (b) In prop 1cement: 4 sand :8 coarse aggregate by volume
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. 35mm thick
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. 100mm thick
REINFORCED CEMENT CONCRETE WORKS Providing and laying plain/ reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) II. Using Batching Plant/ RMC/ Truck mounted batching plant including Transit Mixer and Concrete Pump N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1. 5:3
REINFORCED CEMENT CONCRETE WORKS Providing and laying plain/ reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) II. Using Batching Plant/ RMC/ Truck mounted batching plant including Transit Mixer and Concrete Pump N) Without using admixture, plasticiser c) M25 grade concrete
REINFORCED CEMENT CONCRETE WORKS Providing and laying plain/ reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) II. Using Batching Plant/ RMC/ Truck mounted batching plant including Transit Mixer and Concrete Pump N) Without using admixture, plasticiser d) M30 grade concrete
REINFORCED CEMENT CONCRETE WORKS Providing and laying plain/ reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) II. Using Batching Plant/ RMC/ Truck mounted batching plant including Transit Mixer and Concrete Pump N) Without using admixture, plasticiser e) M35 grade concrete
TIMBER SHUTTERING (FORMWORK) Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4. 0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (a) Using 38mm thick plank
TIMBER SHUTTERING (FORMWORK) Columns, Pillars, Posts & Strut (b) Circular or curved in plan (Using 38mm thick plank)
PLYBOARD SHUTTERING (FORMWORK) Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4. 0M and removal of the same for in situ reinforced concrete and plain concrete work in: Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1. 0M.
STEEL SHUTTERING: Providing formwork using 2mm pressed bend shuttering plate of mild sheet and tubular telescopic steel props including centering, shuttering, strutting and propping etc. complete and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/ L etc. having plane vertical face
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
Sloping or Battering sufaces such as sloped slabs etc. including folded plates. (a) Where inclination to horizontal plane does not exceed 30o requiring shuttering only on the underside.
Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Extra for each subsequent 1. 0M height or part thereof beyound the initial height of 4. 0M as mentioned in item no. 14
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Filling sunken floor with broken jhama brick bats and sand including compacting and supplying of materials complete as specified and directed for all levels.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (d) In proportion 1:6.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (II) In superstructure above plinth level up to 1st floor level. (d) In proportion 1:5. (1 cement:5 sand)
Autoclaved Aerated concrete Block work using Grade-I AAC block of compressive strength 40Kg/cm2 having dry density 550 to 650 Kg /Cum conforming to IS-2185 Pt-3 or pt-4 in cement mortar of prop 1:4 or required block joining/plastering mortar including racking out joints and curing complete as specified & directed. (Superlite/BrikOlite/Green AAC Block) (ii) In Super structure above plinth level upto 1st floor level
Extra for AAC block walling for each subsequent floor or part thereof above the 1st floor level. (i) AAC block work over item No. 24
Chequered Terrazo tiles of 22 mm thickness with marble chips of sizes up to 6 mm fixed on wall with 10 mm thick bed of cement plaster in proportion 1:3 (1 cement : 3 coarse sand) jointed with neat white cement slurry mixed with pigment to match the shades of tiles including rubbing and polishing complete with tiles of any approved shade/ shades. (c) Using ordinary cement
CERAMIC TILES B) ON WALLS Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). a) Normal range Somany/ Orient/Nitco/Asian Make ii) Of size 200mmx300mm and above
VITRIFIED TILES A) ON FLOOR Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 8 mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above
c) Delux range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make i) Of size 1000mmx1000mm and above
KOTA STONE SLAB/ SAND STONE FLOORING Kota-stone slab flooring of 18 mm thick over 20mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (1) 550mm x 550mm
Kota stone slab of 18 mm thick in riser of steps, skirting, dado and pillars laid with 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete. (1) 550mm x 550mm
18 mm thick marble stone tiles in flooring including risers and treads of steps, skirting, dado, walls, pillars laid with 10 mm thick base of cement plaster in prop. 1:3 ( I cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing complete with marble tiles of specified quality and shade at all levels. (a) With 18mm thick marble stone tiles of size 600mm x 600 mm (iv) Rajnagar Marble
GRANITE WORK Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
ANTISKID TILES Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (A) CERAMIC i)Normal range (Sizes 300 mm x 300mm and above) (a)Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate
CEMENT PLASTERING 10 mm thick Cement plaster in single coat on fair side of brick/ concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
CEMENT PLASTERING 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
Extra over item no 35 & 36 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed. i) 10 mm thick plaster b) In cement mortar 1:4
Extra over item no 35 & 36 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed. ii) 15 mm thick plaster b) In cement mortar 1:4
Extra over item no 35 & 36 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 35 & 36 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. a) On Single coat plaster
Extra over item no 35 & 36 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. a) On Single coat plaster
Extra over item no 35 & 36 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed. a) On Single coat plaster
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (i) Thickness = 1.5 mm thick
m) Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after throughly brooming the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth. (i).Priming coat with distemper primer
(ii). Top coat
q) Extra over item no 44 & 45 above for distempering with oil bound distemper of approved brand and manufacture on celing and sloping roof.
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra over item no 47 above for painting with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on celling and on sloping roof. (i).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Applying priming coat over new wood based surfaces up to 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) Dyna roof / Durakolor /Wonder Roof / JSW Steel/ Spectrum or equivalent as directed by the Departement (iv) 0.60 mm thick
Providing and laying machine made clay roof tiles on sloping roof and chajjas over 20mm thick base of cement mortar 1:3 and jointed with grey cement slurry and joints flush with mortar 1:3 complete.
ROOF TREATMENT Grading roof for water proofing treatment with (a) Cement concrete 1:2:4 (cement: 2 coarse sand: 4 graded stone agg. 20 mm nominal size)
Providing and application of Insultech safeguard coating for heat reflecting and waterproofing of approved colour as per direction of engineer in charge
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C. C or brick masonry wall including supplying, fitting and fixing with M. S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C. C and masonry as directed and specified. (b) With 1st class timber (Bonsum/ Sundi)
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. II Ornamental grill (b) Fixed to steel frames
PARTITION WALLS WITH DOORS Providing, fitting and fixing anodised aluminium framed glazed doors with partition walls partly glass and partly prelaminated board with anodised aluminium frame made of 100mm x 43mm x 2mm sections of approved brand with doors style of size 81mm x 43mm x 2mm, top rails 46mm x 43mm x 2mm, lock rails 81mm x 43mm x 2mm, fitting with glazing clip, special rubber type gusket complete including hydraulic floor spring pivot aluminium door handle lock angles cleat etc. complete as directed by the Architect at all levels. (v) Prelaminated Board
CURTAIN WALL, CURTAIN GLAZING, STRUCTURAL GLAZING Providing, fitting and fixing aluminium curtain wall on the exterior face of building fitting to concrete member by drilling hole fixing by brass screw fabricated with coloured anodised aluminium section of approved brand of size 101mm x 44. 50mm by providing aluminium jointing angles including providing 6mm thick coloured reflectory type glass fitted with aluminium at all levels. (iv) 6mm coloured glass
Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2. 5mm section with door style of size 88mm x 45mm x 2. 5mm, top rails 50mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2. 5mm fitted with glazing clip, special type rubber gasket complete etc complete as specified and directed by the Architect at all levels. (a) with 12 mm thick toughened glass
Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) b) 29mm thick
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. c) One face decorative and other face nondecorative type and block board core. (ii) 35 mm thick .
Supplying and installing uPVC- Casement Door made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC sections of wall thickness 2.4mm, multichambered with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including glazing bead, folding gasket, glazing gasket, locking arrangement, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. (a) Single leaf Side hung Door using uPVC section of size 58mm x 69mm x 2.4mm thick wall for frame, 58mm x 109mm x 2.4mm thick wall for glass sash, Aluminium threshold at bottom (WINSTA KOMMERLING/ FINESTA/ ENCRAFT) ii) Using 5mm clear toughened glass
ALUMINIUM FITTINGS Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) Tower bolts 300mm x 12mm
Door handles 150 mm
Door stopper with rubber stopper
Sliding door bolts 300mm x 16mm
Mortice lock vertical type 100 mm (Godrej) with handle (6-lever)
Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I. S. Code for R. C. C. work/ R. B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/ SAIL/ Esser Steel/ Jindal steel/ Shyam steel/ RINL (ii) Super Ductile (SD) TMT reinforcement bars
Extra over item 70 for each subsequent floor or part thereof above first floor level.
BEAMS AND JOISTS Structural steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4. 6m height) from plinth level including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. a) In beams and joists fitted independently without connecting plates.
BEAMS AND JOISTS Structural steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4. 6m height) from plinth level including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. b) In flat up to 25mm thickness
BEAMS AND JOISTS Structural steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4. 6m height) from plinth level including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. c) In M. S. angles, channels, Tees etc.
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
Providing, fitting and fixing powder coated pressed steel door frame made of 1. 25mm/ 1. 6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1. 25mm thick. Frame to be filled up with 1:4:8 P. C. C. after fitting the frame with brick/ concrete works etc. complete as directed by the department for all levels. (P. C. C. to be measured and paid for seperately). 1. 25mm thick sheet (ii) Size 105mm x 60mm (Single rebate)
Providing and fixing Stainless Steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i. e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment, only weight of Stainless Steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
Providing plinth protection with bricks laid on edge and grouted with cement mortar 1:4 and finishing with cement pointing in prop. 1:1 complete.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
MACHINE DRIVEN PILES Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 82) C) UNIFORM PILE (II) Concrete Grade M25 v) Pile dia 500 mm
MACHINE DRIVEN PILES Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 82) C) UNIFORM PILE (II) Concrete Grade M25 vii) Pile dia 600 mm
REINFORCEMENT Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor... etc) (A) TMT bar made of Primary producer (From Primary producer)
PILE TESTS Routine test for test loading to 1. 5 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
Initial test for test loading to 2 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
WATER PROOFING OF CHAJJAS, ROOF SLABS, TERRACES, SUNKEN SLABS, SEPTIC TANK, OH TANK, RAFT SLAB IN BASEMENT, WALLS ETC. Providing and laying modified bituminous water proofing membrane system in roof, Polymod-AP of choksey Chemicals, 3mm thick APP modified waterproofing membrane by torch on method using LPG torch flame after applying a coat of Bituminous primer "Primer Polymod-SB" @ 0. 2kg/ sq. m. complete as specified and directed by the Architect followed by : Supplying, providing, mixing and laying of concrete screed of average 75mm thick in proportion 1:2:4 (1cement : 2fine aggregate : 4coarse aggregate) (by volume) with 12mm and down well graded aggregates and admixed with a normal plasticizer like Master Plast PL-1 of Choksey Chemicals/ Dr. Sealkit Normal Plast (Asian Chemicals) @ 0. 3% by weight of cement after making the concrete fibre reinforced for reducing the effect of thermal expansion by mixing concrete with Recron 3S @ 1. 25kg per bag of cement and/ as specified and directed by the Architect.
Providing and applying over sunken slab etc., two coats of waterproofing slurry prepared with neat cement, water and modified Styrene Butadiene Rubber based polymer by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Architect complete.
Surface dressing of ground including removing vegitation and/ or undulation of ground not exceeding 150mm deep and disposal of rubbish outside the periphery and lift up to 1800mm in all kinds of soil.
Expansion Joint Filler Board Providing and fixing Duraboard HD-100 premoulded compressible filler board at all heights and depths of minimum density 95kg/ cum, non-staining having less than 1% water absorption, compression recovery of 93% (minimum) as per manufactured specification with polysulphide sealant to seal the expansion joint including preparation of surface, Polymer Modified Mortar (PMM) (Proportion 1cement: 3 sand:1 acrylic polymer) nozing, carriage of materials, cutting and placing to the required size complete at all levels as per drawings and direction of Engineer-in-Charge. (d) 50mm wide
PRE CONSTRUCTION ANTI - TERMITE TREATMENT Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26. 1. 3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Architect complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i. e. 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4. 5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Architect complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i. e. 1% solution.
Supplying and installing uPVC- Casement Windows made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC sections of wall thickness 2.4mm, multichambered with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including glazing bead, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets,bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. b) Double leaf Side hung Window with a fixed Mullion (2 Panels) using uPVC profile size of 58mm x 57mm x 2.4mm thick wall for frame, 58mm x 68mm x 2.4mm thick wall for glass sash, 58mm x 74mm x 2.4mm thick for mullion. With 5mm clear float glass
Supplying and installing uPVC- Sliding Windows made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass (a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash having 1.5mm thick reinforcement, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FINESTA/ ENCRAFT) (i) 2-Panel with 5mm clear float glass
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P. V. C. sheet 1mx 1mx 400 micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge and making and finishing the outlet complete.
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material,, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 Plant mix method (with Mechanically crushed stone only) Grading-IV Material
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD.
Cast in Situ Cement Concrete M20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundationcon crete laid manually, all complete as per clause 409)
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement:3 sand:6 coarse aggregate by volume
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
Deep Tube well (130. 00 m depth) Labour for test boring with 40mm (internal) dia G. I. Pipes including keeping surplus of earth and every 2. 00m after first 3. 00m depth and delivering the same in nearest P. W. D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. v) Bore hole of 175mm diameter
Supplying, fitting and fixing pipes plain/ bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. 1)G. I. pipe a) TATA/ SAIL (Medium) socket should be welded to the pipes. (vi) 150mm diameter
Supplying, fitting and fixing suction pipes plain/ bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. 1)G. I. pipe a) TATA/ SAIL (Medium)socket should be welded to the pipes. (vii) 100mm diameter
Supplying fitting and fixing GI filter 2. 00 metre long.
Supplying fitting and fixing check valve (non return valve) including thread to pipes. vii) 100mm diameter
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Flushing, clearing, washing and watering of the tube well
Supplying fitting and fixing G. I. Pipes of following sizes, with all necessary 'R' brand or similar approved G. I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H. W. clamps etc. complete at all levels including below G. L. as directed and specified. (A) Exposed on walls b) 40 mm dia (Medium) i) Using Tata make
Supplying fitting and fixing G. I. Pipes of following sizes, with all necessary 'R' brand or similar approved G. I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H. W. clamps etc. complete at all levels including below G. L. as directed and specified. (A) Exposed on walls b) 40 mm dia (Medium) d) 25 mm dia (Medium) i) Using Tata make
Supplying & Installation of suitable Hp submersible pump B. S or K. S. B or equivalent make with finolex cable 1x3x2. 5 squmm(upto 75mtr) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as MCB of 0-25Amp (Havell or Indocopp or MDS make), Volt & Ampere meter (AE make), single phase preventer (Minilac or VSP -1 make) starter (L&T or BCH make) etc of approved make, 40mm Pipe (25 mtr) and all accessories complete as per requirement of site.
POT PLANTING Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed. (Mixing of different ingredients of soil media to be made in presence of Deptt. official/ Specialist concerned) (A) With Aeirides (I) Using earthen pot of 30 cm dia.
POT PLANTING Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed. (Mixing of different ingredients of soil media to be made in presence of Deptt. official/ Specialist concerned) (B) With Dendrobium (Hybrid) (I) Using earthen pot of 30 cm dia.
POT PLANTING Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed. (Mixing of different ingredients of soil media to be made in presence of Deptt. official/ Specialist concerned) (C) With Mokara (I) Using earthen pot of 30 cm dia.
POT PLANTING Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed. (Mixing of different ingredients of soil media to be made in presence of Deptt. official/ Specialist concerned) (D) With Vanda (hybrid) (I) Using earthen pot of 30 cm dia.
Supplying and planting of house plants in required size of pot including filling the pot to the top surface with appropriate soil media of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed. (Mixing of different ingredients of soil media to be made in presence of Deptt. official/ Specialist concerned) (A) With Fancy leaf caladium/ Coleus (i) Using earthen pot of 30 cm dia.
Supplying and planting of house plants in required size of pot including filling the pot to the top surface with appropriate soil media of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed. (Mixing of different ingredients of soil media to be made in presence of Deptt. official/ Specialist concerned) (B) With Indian rubber plant/ Prayer plant (i) Using earthen pot of 30 cm dia.
Supplying and planting of house plants in required size of pot including filling the pot to the top surface with appropriate soil media of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed. (Mixing of different ingredients of soil media to be made in presence of Deptt. official/ Specialist concerned) (C) With Fragrant dracaena/ Silver net leaf/ Philodendron/ Devil's back bone/ Peperomea/ Croton (i) Using earthen pot of 30 cm dia.
Supplying and planting of house plants in required size of pot including filling the pot to the top surface with appropriate soil media of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed. (Mixing of different ingredients of soil media to be made in presence of Deptt. official/ Specialist concerned) (G) With English Ivy (I) Using earthen pot of 30 cm dia.
Supplying and planting of house plants in required size of pot including filling the pot to the top surface with appropriate soil media of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed. (Mixing of different ingredients of soil media to be made in presence of Deptt. official/ Specialist concerned) (H) With Iron Cross Begonia (I) Using earthen pot of 30 cm dia.
Supplying and planting of seasonal flower in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed. (Mixing of different ingredients of soil media to be made in presence of Deptt. official/ Specialist concerned) (I) Using earthen pot of 30 cm dia.
HEDGE PLANTING/ EXTERNAL HEDGE Supplying and planting of suitable plant materials for preparation protective/ external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (A) ADOPTING SINGLE ROW PLANTING METHOD (i) With Duranta
HEDGE PLANTING/ EXTERNAL HEDGE Supplying and planting of suitable plant materials for preparation protective/ external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (A) ADOPTING SINGLE ROW PLANTING METHOD (ii) With Kamini
HEDGE PLANTING/ EXTERNAL HEDGE Supplying and planting of suitable plant materials for preparation protective/ external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (A) ADOPTING SINGLE ROW PLANTING METHOD (iii) With Chinese Bamboo
HEDGE PLANTING/ EXTERNAL HEDGE Supplying and planting of suitable plant materials for preparation protective/ external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (A) ADOPTING SINGLE ROW PLANTING METHOD (iv) With Thuja/ Ixora
TREE PLANTING Supplying and planting of ornamental trees (1'-0" height sapling) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. SHADE TREE (A) Neem/ Mahaneem/ Beef wood/ Bakul/ Acacia/ Siris/ Devils tree/ Kadam/ Palash/ Pink Cassia/ peepal/ Silver oak/ Simalu/ Ajar
SHRUB PLANTING Supplying and planting of ornamental shrub ( below 1'-0" height ) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (A) Radhachura/ Krishnachura/ Rat ki rani/ Ixora/ Jetuka
SHRUB PLANTING Supplying and planting of ornamental shrub ( below 1'-0" height ) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (B) Allmanda/ Khorika zai/ May flower/ Kamini/ Kathanda/ Tecoma/ Acalypha/ Bougainvillea/ Dracaena/ Togor/ Nilakantha/ Mussaenda
SUBHEAD-I (A) : SANITARY INSTALLATIONS Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1. 8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth White Agaria Marble Stone
Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately (B) Nirali (iv) Grace Deluxe Jumbo (Bowl Size - 610 x 460 x 254) Glossy
Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately (B) Nirali (vi) Grace Deluxe Medium (Bowl Size - 445 x 368 x 190) Glossy
Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified. (i) Continental toilet paper holder (Cat. No. ACN-1151N)
Providing fitting and fixing Vitreous china wall hang water closet (European type W. C pan 400mm high) with seat and lead, CP brass hinges and rubber buffers, CI/ MS brackets, 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) a) White (viii) Wall mounted Closet Dove (inclusive of seat cover and fittings)
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) B) Hindware make a) White (viii) Water closet UNIVERSAL "P (Cat.No.20012) (inclusive of seat cover)
Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make a) White (iv) Deluxe Dual Flush (Cat No.C8110)
Providing and fixing 8 mm dia C. P. / S. S. Jet with flexible tube upto 1 metre long with S. S. triangular plate to Eureopean type W. C. of quality.
Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe
Supplying fitting and fixing Chrome Plated (C. P. ) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) (i) Overhead rose shower with revolving joint & 150mm long shower arm with wall flange
Providing, fitting and fixing CP soap tray/ soap dish complete as directed and specified.
Supplying, fitting and fixing Chrome Plated (C. P. ) wall mixer complete as directed. iii) Wall mixer 3 in 1 system with provision for both telephonic shower and overhead shower complete with wall flange with 115mm long bend pipe
Supplying fitting and fixing C. P. bib cock 15mm dia of approved brand as directed and specified. (G. I. & C. P pipes will be measured separately) ii) Bibcock long thread
Supplying fitting and fixing C. P. bib cock 15mm dia of approved brand as directed and specified. (G. I. & C. P pipes will be measured separately) (iii) 2-Way bib cock
Providing vitreous China wash basin with CI/ MS brackets, C. P brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Wall Hang Basin
Supplying, fitting and fixing Chrome Plated (C. P. ) basin mixer complete as directed. a) Florence i) Central hole basin mixer without pop-up Cat No. 21051 for wash basin
Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (v) Senso Urinal
Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified.
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (i) 32mm (HT/ FT)
Supplying and fitting fixing Sensors of complete as directed. (For VIP use only. Prior approval of Chief Engineer PWD (Bldg) must be taken before use) b) Sensotronic Sensor Faucet for wash basin
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified. (i) Continental towel ring square
Providing, fitting and fixing CP towel rail complete as directed and specified. (i) Continental 300mm for wash basin
Supplying, fitting and fixing Chrome Plated (C. P. ) sink mixer complete as directed. a) Continental/ Clarion i) Sink mixer with swinging casted spout (wall mounted model)
Providing fiting & fixing C. I. Grating to the floors complete as directed and specified. (a) 110mm dia
Supplying, fitting and fixing I. S. I marked or similar approved H. C. I pipe including bolts and nuts and other fittings as required and complete at all levels including below G. L as directed and specified. a) In exposed surfaces or in trenches. (i) 150mm dia.
Supplying, fitting and fixing I. S. I marked or similar approved H. C. I pipe including bolts and nuts and other fittings as required and complete at all levels including below G. L as directed and specified. a) In exposed surfaces or in trenches. (ii) 100mm dia.
Supplying, fitting and fixing I. S. I marked or similar approved H. C. I pipe including bolts and nuts and other fittings as required and complete at all levels including below G. L as directed and specified. b) Concealed by chiselling or breaking brick wall/ C. C. / R. C. C and making good to the damages. (i) 150mm dia.
Supplying, fitting and fixing I. S. I marked or similar approved H. C. I pipe including bolts and nuts and other fittings as required and complete at all levels including below G. L as directed and specified. b) Concealed by chiselling or breaking brick wall/ C. C. / R. C. C and making good to the damages. (ii) 100mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/ cm2 (Supreme/ Prince) or other ISI approved including joining, fitting and fixing wiyh clamps etc. as necessary complete at all levels including below G. L as directed and specified. (v) 63 mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/ cm2 (Supreme/ Prince) or other ISI approved including joining, fitting and fixing wiyh clamps etc. as necessary complete at all levels including below G. L as directed and specified. (vi) 50mm dia
Providing fitting and fixing 50mm dia. HCI cowel with cement caulking complete as directed and specified.
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/ c fixing the pipe with clamps at 1. 00m spacing. This includes jointing of pipe (A)) Exposed or in trenches 15 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/ c fixing the pipe with clamps at 1. 00m spacing. This includes jointing of pipe (A)) Exposed or in trenches 20 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/ c fixing the pipe with clamps at 1. 00m spacing. This includes jointing of pipe (A)) Exposed or in trenches 25 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/ c fixing the pipe with clamps at 1. 00m spacing. This includes jointing of pipe (A)) Exposed or in trenches 32 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/ c fixing the pipe with clamps at 1. 00m spacing. This includes jointing of pipe (A)) Exposed or in trenches 40 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/ c fixing the pipe with clamps at 1. 00m spacing. This includes jointing of pipe (A)) Exposed or in trenches 50 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/ c fixing the pipe with clamps at 1. 00m spacing. This includes jointing of pipe (B) Concealed pipe with cutting chases & making good the walls 15 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/ c fixing the pipe with clamps at 1. 00m spacing. This includes jointing of pipe (B) Concealed pipe with cutting chases & making good the walls 20 mm nominal outer dia pipes
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed b) For roof level iii) 25mm diameter
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed b) For roof level iv) 32 mm diameter
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed b) For roof level v) 40 mm diameter
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed b) For roof level vi) 50mm diameter
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed b) For roof level vii) 65mm diameter
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed b) For roof level viii) 80mm diameter
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. d) 20mm dia
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. c) 25 mm dia
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. b) 40mm dia
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. a) 50mm dia
Supplying fitting and fixing check valve (non return valve) including thread to pipes. iv) 50mm diameter
Supplying fitting and fixing check valve (non return valve) including thread to pipes. vi) 80mm diameter
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G. I. & C. P. pipes will be measured and paid separately) (ii) 20mm dia
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G. I. & C. P. pipes will be measured and paid separately) (iii) 25mm dia
Supplying & Fixing,cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc (IS:13095) of following size complete as reqd. (MAKE:KOLEY/KALPANA/AUDCO). 65 nominal bore
Supplying & Fixing,cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc (IS:13095) of following size complete as reqd. (MAKE:KOLEY/KALPANA/AUDCO) 80 nominal bore
Supplying & Fixing,cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc (IS:13095) of following size complete as reqd. (MAKE:KOLEY/KALPANA/AUDCO) 100 nominal bore
Making connection of GI distribution branch with GI main of 50-80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete.
Supplying and fitting ball valve as specified and directed.. 20 mm dia nominal bore
Supplying and fitting ball valve as specified and directed.. 25 mm dia nominal bore
Constructing brick masonry manhole with F. P. S. bricks in cement mortar 1 : 4 (1 cement : 4 coarse sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size) ; foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete as per standard design Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimension total wt. of cover & frame to be not less than 38 kg (wt. of cover 23 kg and wt. of frame 15 kg)
Extra for depth for manhole with F. P. S. bricks size 90 X 80 cm
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing square mouth SW gully trap grade ‘A’ complete CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13. 00 kg and frame to be not less than 5 kg. as per standard design. (COVER MIN. 4. 5 KG & FRAME MIN. 2. 7 KG) 180x150 mm size P type With FPS bricks
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement cincrete 1:2:4 mix (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete for pipes 100 to 230mm dia.
Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage) 150 mm dia RCC pipe
Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage) 300 mm dia RCC pipe
Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage) 450 mm dia RCC pipe
Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:5 (1 cement : 5 fine sand) including 500 x 450 mm (heavy duty) precast RCC horizontal grating with frame complete as per standard design: With FPS bricks
RAINWATER HERVESTING SYSTEM For R. C. C Roofing Providing, Fixing, testing &Commissioning of Rain water Hervesting system for 100 Sqm roof area with 110 mm uPVC pipe of Class-3 conforming to IS:4985-200 (with uptodate amendment) with extra UV ray protection by Titanium Dioxide (TiO2) directing the Rainwater to Rainy filter/ Pop-up raintap filter (Excluding Civil Works)
For GI sheet Roofing Storage of Rainwater Supplying, fitting and fixing of Water storage tank ISI Marked, conforming to IS:12701/ 1996 (with uptodate amendment). (Excluding Civil Works)
For Overflow pipe Supplying, fitting and fixing PVC pipes of 6 Kg/ cm2 (Supreme/ Prince) or other ISI approved including joining, fitting and fixing wiyh clamps etc. as necessary complete at all levels including below G. L as directed and specified. b) Concealed by chiselling or breaking brick wall/ C. C. / R. C. C and making good to the damages. (i) 160mm dia.
FIRE PUMPS - ELECTRICAL Supply, installation, testing and commissioning of horizontal single stage centrifugal type factory assembled fire pumps suitable for autometic operation at synchoronous speed of 2900 rpm, TEFC conforming to IP-55 & flexible coupling gaurd mounted on a common structural base plate with 150mm dia gun metal pressure gauges with isolation cock and piping, suitable vibration elimination pads of approved design for pump foundation, motor to be suitable for 415 volts, 3 phase 50 cycles AC. Capacity 2280 LPM at 7. 0 Kg/ cm2 delivery pressure for Fire Hydrant Network.
FIRE PUMPS - ELECTRICAL Supply, installation, testing and commissioning of horizontal single stage centrifugal type factory assembled fire pumps suitable for autometic operation at synchoronous speed of 2900 rpm, TEFC conforming to IP-55 & flexible coupling gaurd mounted on a common structural base plate with 150mm dia gun metal pressure gauges with isolation cock and piping, suitable vibration elimination pads of approved design for pump foundation, motor to be suitable for 415 volts, 3 phase 50 cycles AC. Capacity 180 LPM at 7. 0 Kg/ cm2 (Jockey Pump).
Electric Motor Driven Hose Reel Pump (Location - Roof) Supplying, installing, testing and commissioning of Fire authority approved Electrical driven fire pump suitable for automatic/ manual operation consisting of the following: Horizontal mounted split casing type fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 900 LPM against a total head of 35 M while running at 1400 RPM complete with mechanical seal pressure gauge with GM cock on the delivery side of pump and including 50 mm by pass arrangement (with 50 mm valve and up to 5 meter GI class 'B' pipe) for periodical testing of working of pumping test. Squirrel cage, induction motor TEFC type suitable for 415 + 10%V, 1 phase, 50 Hz, AC supply, of suitable HP rating for the above pump with synchronous speed of 1400 RPM with flexible coupling and coupling guard. Common bed plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with heavy duty Anti Vibration pads (4 Nos., heavy duty). Coupling and coupling guard for direct coupling of pump and motor. Drain Pipe with Valve (50 mm dia) Hose Reel Pump Discharge : 900 LPM App. Head : 35 m App. HP : 15. 0 PANELS: Supply, installation, testing and commissioning of followingintegrated, cubicle type, dead front, extensible, sheet steel control panel. The panel shall be suitable for 440 volts, 50 cycles, 4 wire supply The following components and accessories shall be mounted with ineach control panel. One no 100 amps TP incoming MCCB with the following: 0-500 volts 96 x96 square mm voltmeter with slector switch and control fuses- 1 SET 0-100 amps 96 x96 square mm ammeter with CT's and slector switch- 1 SET Phase indicating lamp with toggle switches. Indication lamps for ON/ OFF/ TRIP status Outgoing Feeders/ Starters as below: 100 ATP MCCB with star/ delta as starter suitable for 30 HP motor for Downcomer Pump - 1 Set Provision in control panel to connect flow switch for autmatic operation of roof fire pumps.
FIRE PUMPS - DIESEL Supply, installation, testing and commissioning of horizontal single stage centrifugal pumping set with CI volute and bronze impeller with mechanical seals directly coupled to automatic Diesel Engine complete with all accessories like self starting by means of Battery powered electric starter motor, Paper Filter type air cleaner, exhaust silencer etc. complete in all respects. The engine & the pump will be mounted on common base plate on anti-vibration mountings. Capacity 2280 LPM at 7. 0 Kg/ cm2 delivery pressure for Fire Hydrant & Sprinkler Network.
Exhaust piping Providing & fixing 150 mm diameter M. S. Class 'C' diesel pump exhaust pipe includings all fittings, like bends, tees etc. clamps/ structural steel supports. The pipe shall be provided with 75mm thick fiberglass insulation & covering the insulation with 500 g polythene sheet giving proper overlaps & sealing the joints with suitable adhesive compound. The pipe shall be provided with 24 gauge aluminium sheet cladding
Providing, erection, Testing & Commissioning of Pressure Switch
Supply, fabrication (as per code), installation, testing and commissioning of Pressure vessels 250mm diameter and 1200mm high fabricated from 8-10mm M. S. plate with accessories inside painting with epoxy paint and outside with enamel.
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8. 8 Kg/ cm2 and test pressure 14 Kg/ cm2 for :- 150 mm dia
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8. 8 Kg/ cm2 and test pressure 14 Kg/ cm2 for :- 100 mm dia
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8. 8 Kg/ cm2 and test pressure 14 Kg/ cm2 for :- 80 mm dia
Fire Hose Cabinet Providing & fixing of weather proof hose cabinets fabricated from 16 S. W. G. M. S. Sheet with centre opening full front glass door and locking arrangement, suitable to accommodate one landing valve (Yard Hydrant), 2nos. 15M long hoses and 1 no. Branch pipe with nozzle. The cabinet shall be painted with one coat of primer and 2 or more coats of synthetic enamel paint of approved make & shade and shall be suitably mounted on a raised masonry platform complete as reqd. b) 2000 X 1200 X450
Fire Hose Cabinet Providing & fixing of weather proof hose cabinets fabricated from 16 S. W. G. M. S. Sheet with centre opening full front glass door and locking arrangement, suitable to accommodate one landing valve (Yard Hydrant), 2nos. 15M long hoses and 1 no. Branch pipe with nozzle. The cabinet shall be painted with one coat of primer and 2 or more coats of synthetic enamel paint of approved make & shade and shall be suitably mounted on a raised masonry platform complete as reqd. a) 900X600X450
Providing, Fixing, testing &Commissioning of Single Headed Gun Metal ISI Marked oblique pattern Hydrant Landing Valve with 80 mm dia, flanged inlet & 63 mm dia instantaneous type female outlet complete with cap and chain, twist release lug and all accessories as per IS:5290-19833 (Type-'A') and specifications complete as reequired.
63mm dia twin outlet GM landing valve IS marked with suitable size bolts, nuts, washers and gaskets. Landing valve shall be TAC Approved Make.
Supplying, Installation, Testing & Commissioning of First Aid Hose reel drawn with 30 Mtrs. Long rubber hose and G. M shut off nozzle, 25mm dia Gate valve, Union pipe complete set confirming to IS: 884.
Providing RRL Hose with ISI Marked (IS:636) 63 mm dia X15 M long complete with instantaneous type Gun Metal 3 mm dia ISI Marked male & female couplings (IS:903) bound & riveted to hose pipes with copper rivets and copper wire complete as reqd.
Providing & Fixing of Gun Metal 63 mm dia Short Branch Pipe with 20 mm dia nozzle, ISI marked (IS:903) complete as required.
Providing & Fixing of Fire Axe
Supply, installation, testing and commissioning ss orifice plates in pipelines to reduce pressure from 8 kg. to 3. 5 kg/ sq. cm.
Providing & Fixing of Gun Metal fire Brigade Connection (inlet collection head) consisting of 63mm instantaneous type male coupling with built in check valves and 150 mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904-1983 complete as reqd. b) 04 way
Providing & fixing of Gun Metal fire Brigade connection (withdrawl connecting head) consisting of 63mm instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904-1983 complete as reqd. a) 2 way
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1. 5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete. 1:1. 5:3 (1 cement : 1. 5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Constructing masonary chamber 90 x 90 x100 cm. inside with 75 class designation brickwork in cement mortar 1:5 (1 cement : 5 fine sand) for sluice valve with CI surface box 100 mm top dia. 180 mm bottom dia. And 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1 :5 :10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size and inside plastering with 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design with FPS bricks
Providing, Fixing, Testing & Commissioning of air Release Valve b) 50 mm dia
Providing, Erection, Testing & Commissioning of Cast Iron Sluice Valve/ Gate Valve confirming to IS:14846/ 2000 complete with matching flanges, rubber insertion, nuts, bolts and washer etc of following size complete as required (b) 150 mm dia
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled/ hot water circulation including insulation as specified. 150 mm dia.
Supplying & Fixing Cast iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. 80 mm dia
Supplying & Fixing Cast iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. 100 mm dia
Supplying & Fixing Cast iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. 150 mm dia
Supplying & Fixing, cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc (IS:13095) of following size complete as reqd. 150 mm dia
Supplying & Fixing, cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc (IS:13095) of following size complete as reqd. 200 mm dia
Providing, erection testing & commissioning of pressure gauge 100 mm dia (0-10Kg/ cm2)
Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. complete with all fittings (butt welded) viz flanges, bends, tees, elbows, reducers etc including excavation (upto 1. 5 m Deep), back filling and removal of surplus soil & providing anti corrosive treatment (coating and wrapping) as per IS:10221 with 4 mm thick tape complete as reqd. for under-ground pipe. 150 nominal bore (class C)
Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. complete with all fittings (butt welded) viz flanges, bends, tees, elbows, reducers etc including excavation (upto 1. 5 m Deep), back filling and removal of surplus soil & providing anti corrosive treatment (coating and wrapping) as per IS:10221 with 4 mm thick tape complete as reqd. for under-ground pipe. 100 nominal bore (class C)
Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. a) 200 mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. b) 150 mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. c) 100 mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. d) 80 mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. e) 65 mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. f) 50 mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. g) 40 mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. h) 32 mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe. i) 25 mm dia
Supply, installation, testing & commissioning of 150 mm dia installation control valve assembly comprising of vertical wet alarm valve, hydraulic alarm motor & gong, 15 mm dia Test Valve, 50 mm dia, Drain Valve and all necessary trimming connections including 02 nos. pressure gauge as per manufacturers catalogue complete as reqd.
Supply, installation, testing and commissioning of 150 mm dia Zonal Control Valve inclusive of 1 nos 150 mm dia butterfly valve, 150mm diam. non return valve, Flow Switch, water pressure gauges & 25 mm dia. Auxillary Drain valve with sight glass with necessary GI (H) piping with threaded fittings of required sizes complete 150 mm dia butterfly valve 150mm diam. non return valve Flow switches in 150 mm. dia M. S. Pipe pressure gauges Pressure gauges in the M. S. Pipe Line including connection etc. as required. 25 mm dia. Auxillary Drain valve Sight glass
Supplying, Installation, Testing & Commissioning of 15 mm dia quartzoid Bulb Type G. M. Sprinkler Head sutable to operate at 68* C complete as reqd.
Providing, erection testing, Commissioning of Cast Iron Foot Valve/ Stainer confirming to IS:4038/ 1538 complete with flanges, nuts, bolts and washer etc as required (b) 150 mm dia
Supply, Installation, Fixing of CARBON DIOXIDE Fire Extinguisher confirming to IS: 2878 with ISI Mark. (4. 5 LITERS)
Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built – In pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle As per IS:13849 with ISI mark (05 kg capacity)
Supply, Installation, Fixing of MECHANICAL FOAM (AFFF) Fire Extinguisher confirming to IS: 10204 with ISI Mark and CO2 Cartridge will be confirming to IS: 4947 with ISI mark, (AFFF) will be confirming to IS: 4989 with ISI Mark. (50 LITERS)
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (Extinguisher will be TROLLEY MOUNTED) (75 KG)
Wiring for light/ fan/ call bell point with 2x1. 5 sq. mm. P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (as approved. ) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit complete Short point upto 3. 00 metre length.
Wiring for light/ fan/ call bell point with 2x1. 5 sq. mm. P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit complete Medium point upto 6. 00 metre length.
Wiring for light/ fan/ call bell point with 2x1. 5 sq. mm. P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit complete Long point upto 10. 00 metre length.
Wiring for circuit wiring with P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (make as approved) in surface/ recessed ISI marked steel conduit pipe wiring system. With 3 x 1. 5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P. V. C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts in surface/ recessed PVC 2 mm thick conduit wiring system. With 2 x 2. 5 sq. mm. + earth continuity with 1x1. 5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P. V. C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts in surface/ recessed PVC 2 mm thick conduit wiring system. With 2 x 4 sq. mm. + earth continuity with 1x2. 5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P. V. C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts in surface/ recessed PVC 2 mm thick conduit wiring system. With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P. V. C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts in surface/ recessed PVC 2 mm thick conduit wiring system. With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P. V. C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts in surface/ recessed PVC 2 mm thick conduit wiring system. With 4x 6 sq. mm. + earth continuity with 2x4 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P. V. C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts in surface/ recessed PVC 2 mm thick conduit wiring system. With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P. V. C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts in surface/ recessed PVC 2 mm thick conduit wiring system. With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring to 5 a pin 6 Amps plug point with 1. 5 sq. mm P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit wiring system including earth continuity with 1. 5 sq. mm. cable to third pin of the plug socket etc. as required complete. Short point upto 3. 00 metre length.
Wiring to 5 a pin 6 Amps plug point with 1. 5 sq. mm P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit wiring system including earth continuity with 1. 5 sq. mm. cable to third pin of the plug socket etc. as required complete. Medium point upto 6. 00 metre length.
Wiring to 5 a pin 6 Amps plug point with 1. 5 sq. mm P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit wiring system including earth continuity with 1. 5 sq. mm. cable to third pin of the plug socket etc. as required complete. Long point upto 10. 00 metre length.
Wiring for 5/ 6 pin 16 Amps power plug point with 4 sq. mm. P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed conduit wiring system including earth continuity with 2. 5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit Short point upto 3. 00 metre length.
Wiring for 5/ 6 pin 16 Amps power plug point with 4 sq. mm. P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed conduit wiring system including earth continuity with 2. 5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit Medium point upto 6. 00 metre length.
Wiring for 5/ 6 pin 16 Amps power plug point with 4 sq. mm. P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed conduit wiring system including earth continuity with 2. 5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit Long point upto 10. 00 metre length.
Wiring for twin control light point with 1. 5 sq mm P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit including 6 amp flush type 2 way switch GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose etc. complete Short point upto 3. 00 metre length.
Wiring for twin control light point with 1. 5 sq mm P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit including 6 amp flush type 2 way switch GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose etc. complete Medium point upto 6. 00 metre length.
Wiring for twin control light point with 1. 5 sq mm P. V. C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit including 6 amp flush type 2 way switch GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose etc. complete Long point upto 10. 00 metre length.
Supply and fixing of 19 mm dia 1. 50mm to 2. 00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit on surface system including painting etc as required:
Supply and fixing of 25 mm dia 1. 50mm to 2. 00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit on surface system including painting etc as required:
Supplying and fixing of following Metal Boxes in surface/ recessed system complete as per direction of Architect. 1-2 Module Type Metal
Supplying and fixing of following Metal Boxes in surface/ recessed system complete as per direction of Architect. 3 Module Type Metal
Supplying and fixing of following Metal Boxes in surface/ recessed system complete as per direction of Architect. 4 Module Type Metal
Supplying and fixing of following Metal Boxes in surface/ recessed system complete as per direction of Architect. 6 Module Type Metal
Supplying and fixing of following Metal Boxes in surface/ recessed system complete as per direction of Architect. 8 Module Type Metal
Supplying and fixing of following Metal in surface/ recessed system complete as per direction of Architect. 12 Module Type Metal
Supplying including installation of socket outlet 6/ 10/ 13 Amps INTERNATIONAL SOCKET including making necessary connections as per direction of Architect.
Supplying with fitting and fixing of 16 amp one way modular clip in switch, including making necessary connections as per direction of Architect.
Supplying with fitting and fixing of 6 amp one way modular clip in bell push including making necessary connections as per direction of Architect.
Supplying with fitting fixing of 6/ 10 amp one way modular clip in switch, including making necessary connection as per direction of Architect.
Supplying with fitting and fixing of 6/ 10 amp two way modular clip in switch, Including making necessary connections as per direction of Architect.
Supplying and fixing following modular switch/ socket on the existing modular plate & plate switch box including connections but excluding modular plate etc. as required 6 Pin 15/ 16 A socket outlet
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting SPN MCB DB incorporated with bus-bar, Neutral link, Earth Bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified & directed. 6 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting SPN MCB DB incorporated with bus-bar, Neutral link, Earth Bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified & directed. 8 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting SPN MCB DB incorporated with bus-bar, Neutral link, Earth Bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified & directed. 12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting vertical per phase isolation (PP) DB incorporated with bus-bar 125A, Neutral link, Earth Bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified & directed. 6 way TPN (8+6+18) double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting vertical per phase isolation (PP) DB incorporated with bus-bar 125A, Neutral link, Earth Bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified & directed. 8 way TPN (8+6+24) double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting vertical per phase isolation (PP) DB incorporated with bus-bar 125A, Neutral link, Earth Bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified & directed. 12 way TPN (8+6+36) double door
Supplying with fitting and fixing single pole 10KA 240/ 415V 50Hz MCB of the following capacity complete with making necessay connection as approved, specified and directed. C Series 6 to 32A
Supplying with fitting and fixing DP 10KA 240/ 415V 50Hz MCB of the following capacity complete with making necessary connection as approved, spcified and directed. C Series 6 to 32A
Supplying with fitting and fixing DP 10KA 240/ 415V 50Hz MCB of the following capacity complete with making necessary connection as approved, spcified and directed. C Series 40A
Supplying with fitting and fixing 4P 10KA 240/ 415V 50Hz MCB of the following capacity complete with making necessary connection as approved, spcified and directed. C Series40A
Supplying with fitting and fixing 4P 10KA 240/ 415V 50Hz MCB of the following capacity complete with making necessary connection as approved, spcified and directed. C Series63A
Supplying with fitting and fixing 4P 10KA 240/ 415V 50Hz MCB of the following capacity complete with making necessary connection as approved, spcified and directed. C Series6 to 32A
Supplying with fitting and fixing 30/ 100/ 300mA sensitivity 240/ 415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, spcified and directed. 30mA sensitivity DP RCCB 40A
Supplying with fitting and fixing 30/ 100/ 300mA sensitivity 240/ 415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed. 30mA sensitivity 4P RCCB 25A
Supplying with fitting and fixing 30/ 100/ 300mA sensitivity 240/ 415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed. 30mA sensitivity 4P RCCB 40A
Supplying with fitting and fixing 30/ 100/ 300mA sensitivity 240/ 415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed. 30mA sensitivity 4P RCCB 63A
Cross over/ Junction box Supplying including fitting and fixing of TV SOCKET, including making necessary connections as per direction of Architect.
Supplying including fitting and fixing of following star rated A. C. ceiling fan complete with all accessories like down rod, canopy etc of following sweeps with making necessary connection cable as approved etc as required complete and as directed by the Architect as required complete etc. (Without regulator). Energy efficient 5-star 1200 mm sweep.
Providing and fixing circular/ hexagonal G. I. box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1. 5 mm thick G. I. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the G. I. box by means of 3. 3mm dia round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M. S. bar bent to shape as required.
Supplying with fitting and fixing of 120 watt electronic modular STEP speed control 2 - module type including making necessary connection as per direction of Architect. 120 watt electronic modular step speed control 2 - module type
Supplying with fitting and fixing of electronic chime including making necessary connection as per direction of Architect.
Supply and laying of following size solid aluminium conductor up to 10 sq. mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/ armour (Aluminium for single core up to 70 sq. mm balance Aluminium strip, Galvanized for cables up to 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm balance all galvanized steel strip), extruded PVC ST2 sheathed, 650/ 1100 V grade as per IS 7098 (Part1) 1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the Architect. Core-3. 5 (A2XFY) 35 sq. mm 3 and 1/ 2 core armoured cable
Supply and laying of following size solid aluminium conductor up to 10 sq. mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/ armour (Aluminium for single core up to 70 sq. mm balance Aluminium strip, Galvanized for cables up to 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm balance all galvanized steel strip), extruded PVC ST2 sheathed, 650/ 1100 V grade as per IS 7098 (Part1) 1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the Architect. Core-3. 5 (A2XFY) 50 sq. mm 3 and 1/ 2 core armoured cable
Supply and laying of following size solid aluminium conductor up to 10 sq. mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/ armour (Aluminium for single core up to 70 sq. mm balance Aluminium strip, Galvanized for cables up to 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm balance all galvanized steel strip), extruded PVC ST2 sheathed, 650/ 1100 V grade as per IS 7098 (Part1) 1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the Architect. Core-3. 5 (A2XFY) 95 sq. mm 3 and 1/ 2 core armoured cable
Supply and laying of following size solid aluminium conductor up to 10 sq. mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/ armour (Aluminium for single core up to 70 sq. mm balance Aluminium strip, Galvanized for cables up to 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm balance all galvanized steel strip), extruded PVC ST2 sheathed, 650/ 1100 V grade as per IS 7098 (Part1) 1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the Architect. Core-3. 5 (A2XFY) 120 sq. mm 3 and 1/ 2 core armoured cable
Supply and laying of following size solid aluminium conductor up to 10 sq. mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/ armour (Aluminium for single core up to 70 sq. mm balance Aluminium strip, Galvanized for cables up to 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm balance all galvanized steel strip), extruded PVC ST2 sheathed, 650/ 1100 V grade as per IS 7098 (Part1) 1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the Architect. Core-3. 5 (A2XFY) 185 sq. mm 3 and 1/ 2 core armoured cable
Supply and laying of following size power/ control copper cables, solid copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/ armoured (Galvanised for cable up to 10x1. 5 sq. mm, 8x2. 5 sq. mm, 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm, balance all all galvanised steel strip), extruded PVC ST2 sheathed, 650/ 1100 V grade as per IS 7098 (Part1) 1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the Architect. 4 Core-4, 2XWY, 2XFY 10 sq. mm four core armoured cable
Supply and laying of following size power/ control copper cables, solid copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/ armoured (Galvanised for cable up to 10x1. 5 sq. mm, 8x2. 5 sq. mm, 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm, balance all all galvanised steel strip), extruded PVC ST2 sheathed, 650/ 1100 V grade as per IS 7098 (Part1) 1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the Architect. 4 Core-4, 2XWY, 2XFY 16 sq. mm four core armoured cable
Supplying Fitting and Fixing of Single compression brass gland heavy duty. Single Compression Brass Gland Heavy Duty. Size:1''
Supplying Fitting and Fixing of Single compression brass gland heavy duty. Single Compression Brass Gland Heavy Duty. Size:1-1/ 4''
Supplying Fitting and Fixing of Single compression brass gland heavy duty. Single Compression Brass Gland Heavy Duty. Size:1-1/ 2''
Supplying Fitting and Fixing of single compression brass gland heavy duty. Single Compression Brass Gland Heavy Duty. Size:1-3/ 4''
Supplying Fitting and Fixing of Single compression brass gland heavy duty. SINGLE compression BRASS GLAND HEAVY DUTY Size: 2"
Supplying Fitting and Fixing of Single compression brass gland heavy duty. Single Compression Brass Gland Heavy Duty. Size:2-1/ 4''
Supplying Fitting and Fixing of Single compression brass gland heavy duty. Single Compression Brass Gland Heavy Duty. Size:2-3/ 4''
Supplying Fitting and Fixing of Single compression brass gland heavy duty. SINGLE compression BRASS GLAND HEAVY DUTY Size: 3 - 1/ 4"
Perforated RM30 Medium Duty Return Flange Cable Tray with Nos Splice RM 30 8-M6 X Gutter Bolt & Nuts upto 300mm and 3 Nos Splice, RM30 12 -M6 X Gutter Bolt & Nuts Above 300mm including stand off bracket. Size of Tray (in mm) 150
Perforated RM30 Medium Duty Return Flange Cable Tray with Nos Splice RM 30 8-M6 X Gutter Bolt & Nuts upto 300mm and 3 Nos Splice, RM30 12 -M6 X Gutter Bolt & Nuts Above 300mm including stand off bracket. Bend 150
Perforated RM30 Medium Duty Return Flange Cable Tray with Nos Splice RM 30 8-M6 X Gutter Bolt & Nuts upto 300mm and 3 Nos Splice, RM30 12 -M6 X Gutter Bolt & Nuts Above 300mm including stand off bracket. Inter/ Exter Bend 150
Perforated RM30 Medium Duty Return Flange Cable Tray with Nos Splice RM 30 8-M6 X Gutter Bolt & Nuts upto 300mm and 3 Nos Splice, RM30 12 -M6 X Gutter Bolt & Nuts Above 300mm including stand off bracket. Tee 150
Perforated RM30 Medium Duty Return Flange Cable Tray with Nos Splice RM 30 8-M6 X Gutter Bolt & Nuts upto 300mm and 3 Nos Splice, RM30 12 -M6 X Gutter Bolt & Nuts Above 300mm including stand off bracket. 4 Way 150
Perforated RM30 Medium Duty Return Flange Cable Tray with Nos Splice RM 30 8-M6 X Gutter Bolt & Nuts upto 300mm and 3 Nos Splice, RM30 12 -M6 X Gutter Bolt & Nuts Above 300mm including stand off bracket. 4 Way 300
Perforated RM30 Medium Duty Return Flange Cable Tray with Nos Splice RM 30 8-M6 X Gutter Bolt & Nuts upto 300mm and 3 Nos Splice, RM30 12 -M6 X Gutter Bolt & Nuts Above 300mm including stand off bracket. STAND OFF BRACKET150
Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department.LGLZ0 1 X 020XC / LGLZ0 1 X 020XCN /LGLZ0 1 X 020XCW (20 W)
Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department.BN 021C LED 20 S PSU CW GR S2
Supplying, installation, testing and Commission of the following indoor Decorative Recess mounted LED down lighter luminaries of model no-LESP01R009XC / LESP01R009XN /LESP01R009XW / L00957R000 / L00940R000 / L00930R000 /LD90-111 - XXX-65-XX complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Jaquar / LT / Wipro make).
Supplying fitting & fixing of LED Kubik Batten tube light fitting 300mm length as required and as directed by the department ( Jaquar or eqvt. make).kubik Series Batten tube fitting 10W
Supplying, installation, testing and Commission of the following indoor Decorative Surface mounted 2' x 2' LED down lighter luminaries of model no-SM365C LED 32 -6500 PSU OD GR / SM365C LED 32 -6500 PSU OD GH / SM365C LED 32 -6500 PSU OD GR /SM365C LED 32 -6500 PSU OD WH/ LSVR01S036SC / LSVR01S0365SN / LSVR01S0365SW/ CRCO10S038HP57G1 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / Jaquar / Wipro make).
Supplying fitting & fixing of LED Bulb non-dimmable in the existing batten / angle holder as required and as directed by the department ( Jaquar or eqvt. make) Prima Series Bulb 12W
Supplying fitting & fixing of LED Bulb non-dimmable in the existing batten / angle holder as required and as directed by the department ( Jaquar or eqvt. make).Prima Series Bulb 9W (for Lift well)
Supply, installation, testing & commissioning of 5 Loop Intelligent/ Analogue Addressable Fire Alarm Panel Microprocessor based character display Network option built in Alarm, Trouble & supervisory relays LPCB listed.
Supply, Installation, Testing & Commissioning of Microprocessor based fire Alarm control panel suitable for wall mounted type with audio visual indication zone i. e. rectifier and charger circuit and maintenance free battery of 2X12 volt with suitable Ampere hour capacity complete (02 Zone panel)
Supply, installation, testing & commissioning of intelligent plug in photo electric Smoke Detectors having features like integral communication, dual LED for 360° viewing angle, walk test with address display etc. UL/ LPCB
Supply, installation, testing & commissioning of Control Module. UL/ LPCB approved, with housing box Model:200e-SMD.
Supply, Installation, Testing & Commissioning of rate of rise & fixed temperature resettable heat detector with mounting base.
Supply, Installation, Testing & Commissioning of Manual Call box made of M/ s. Aluminium dia cast with epoxy coated paint with hammer & chain.
Supply, installation, testing & commissioning of Response Indicator to give visual indication of detection of smoke - RED colour LED for indication.
Supply, Installation, Testing & Commissioning of Fire Alarm hooter with audible range of 25 metre 80 bb output complete.
Supply & fixing of 2X1. 5sq. mm. PVC insulated copper Armoured Cable on surface/ recess/ above false ceiling etc. as required. (ISI marked))
Supply, installation, testing & commissioning of Vertical Electrolytic Copper Lighting Arrester of 16 mm dia, 1000 mm long with Gun Metal base plate.
Supply, installation, testing & commissioning 8 mm round aluminium conductor for horizontal lightning protection - run in roof.
Supply, installation, testing & commissioning of roof conductor holder for 8 mm round aluminium conductor made of Gun Metal for horizontal installation. The distance between each holder should be min of 1 mtr.
Supply, installation, testing & commissioning of T connector for connecting of 8 mm Al round conductor. The connector should be of Gun Metal with SS nuts and bolt.
Supply, installation, testing & commissioning of Cross connector for connecting of 8 mm Al round conductor. The connector should be of Gun Metal with SS nuts and bolt.
Supply, installation, testing & commissioning of Expansion piece along with connector to compensate the expansion of round 8 mm Al conductor when temperature variation. Connection should be in every 20 mtr.
Supply, installation, testing & commissioning GLUE- Glue is used to fix roof conductor holder on roof.
Supply, installation, testing & commissioning of 8 mm round aluminium conductor as a down conductor mounted in the surface of wall which will carry the lightning current to earth pit.
Supply, installation, testing & commissioning of Down conductor holder for 8 mm round aluminium conductor of min distance between the wall to the conductor will be of 85 mm. The distance between each holder should be min of 1 mtr.
Supply, installation, testing & commissioning of straight connector for connecting of 8 mm Al round conductor. The connector should be of Gun Metal with SS nuts and bolt.
Supply, installation, testing & commissioning of 6 digit lightning strike counter.
Supply, installation, testing & commissioning of Test Joint Point for 8 mm round aluminium conductor, the size should be of 25 x 3 x 150 mm copper in ABS boxes.
Supply, installation, testing & commissioning of UL approved low carbon high tensile steel rod with copper coating of min 254 micron JK Chemrode - 0110 CBR the dia should be 25 mm with length of 10 feet (3000 mm). The rod shall be as per IEC 62561-2 and approved by UL 467. The rod shall be tested from NABL lab for current discharge not less then 50kA peak. The Chemrode shall be surrounded with 25 kg (1 bag) of Earth enhance materiel JK Reslow according to IEC 62561-7 and the Chemical resistance value shall not increase more then 0. 067 Ωm and same will be tested from NABL lab. along with earth pit chamber made up polyplastic. Size of -254x330x260 MM
Supplying and laying 25 mm X 5 mm G. I strip at 0. 50 metre below ground as strip earth electrode, including connection/ terminating with G. I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G. I. nut bolt & spring washer spaced at 50mm)
Seminar hall 200 Capacity Supply, Installation, Testing & Commissioning of Projector Single 0. 7" DLP® Technology having Resolution WUXGA (1920 x 1200), Brightness - 6000 ANSI Lumens and Contrast Ratio -2000:1, Lamp Life and Type -1, 500/ 3, 500 hours (Normal/ Eco Mode) 370W/ 280W, Projection Lens -F = 2. 46 - 2. 56 f = 22. 82 - 28. 49mm (std lens), Zoom Ratio -1. 25x (std lens) Aspect Ratio -4:3 Native, 16:10 and 16:9 Compatible, Display Port connector for digital audio and video signals, Built-in 12V trigger for external wireless module connection, Audio ready with 2x3W stereo speakers.
Supply, Installation, Testing & Commissioning of Motorised front Projection Screen, wide (8ft) X hight (6ft) with Remote Control.
Supply Installation Testing & Commissioning of 8" Two-Way System in a Trapezoidal Enclosure; 250W @ 8 ohm Continues Power, 500W program, Frequency 40Hz to 20KHz sensitivity 96dB 1W/ 1M, SPL 125dB, Coverager: 80 (V) & 60 (H) with 1, 4"Compressed treble unit x 1
SITC of 80W 8" + 2 " two way wall mounted speaker with following features:- Built-in 100/ 70 V Variable wattage tappings of 5W/ 10W/ 20W/ 40W/ 80W Watt, SPL 1W/ 1m = 94dB, SPL@Full power = 113dB, EASE/ CATT/ ULYSSYS DLL read, Frequency Response 100 Hz - 17 kHz, Speaker Drive - 8" + 1. 5 ". Complete with all Mounting Accessories.
SITC of digital power amplifier having 2X250Watt @8ohm & 2X350W @4ohm. The amplifier shall provide with short to ground, short circuit detection & line impedence survellience up to 0. 5% deviation. It should have frequency response: 20Hz-20Khz, Slew rate: 30V/ us, damping factor: >100, output circuit class AB, signal to noise ration: >85dB, cross talk: >65dB, THD + N: <0. 05%, input impedance: 0. 8V with short circuit, thermal, over load, chip limiter, Dc voltage protection. complied with EN54 standard.
Supply, Installation, Testing & Commissioning of handheld Wireless Mic system set with two transmitters dynamic microphone, Frequency Response 40Hz-15, 000 Hz, Surge mode PLL Phase lock, Dynamic Range >90dB, THD < 0. 5%, S/ N ratio > 90dB, Carrier frequency range 720 - 830 MHz, Power Consumption < 85mA..
Supply Installation Testing & Commissioning of 8-channel Phantom Power Microphone/ Line input, 8- channel circuit Output; Loudspeaker Management System Frequency Response 20Hz ~ 20KHz, THD <0. 003%, Channel Seperation >92dB, Seperate Mute Control each channel, CMRR>80dB, 8 independent parametric EQ, adjustable gain range up to 20dB, With, RS232 and internet to connect PC, High-speed processing DSP Chip, the new generation of AFC algorithm to eliminate the feedback faster and make system more stable. Application includes Auto Mixer (Limiter threshold and Gain), Routing, Audio Processing and special signal extension Processing.
Supply, Installation, Testing & Commissioning of Lapel Wireless Mic system set with two transmitters dynamic microphone, Frequency Response 40Hz-15, 000 Hz, Surge mode PLL Phase lock, Dynamic Range >90dB, THD < 0. 5%, S/ N ratio > 90dB, Carrier frequency range 720 - 830 MHz, Power Consumption < 85mA.
Supply Installation Testing & Commissioning of 24 channels Mixing console with Mono Input 24 Channel, Stereo Input 4 group, Mono Insertion Channel 24 Channel, output channel main output; 4 output group; 2 CH aux output; 2 CH CD/ TAPE auxiliary output; 2 CH effect output; Phantom power 48V, Frequency Response 20Hz - 20kHz, Channel Crosstalk less than 90dB, S/ N Ratio 83 dB, Gain difference between Channel less than 2 dB, Distortion degree less than 0. 02%, 21 Kind of DSP Effects.
Supply, Installation, Testing & Commissioning of 8X8 HDMI Matrix switcher.
Supply, Installation, testing and commissioning of2x1. 5sqmm speaekr cable
Supply, Installation, testing and commissioning of Shielded 2x1. 5sqmm Microphone
SITC of HDMi/ VGA cable with connectors
Supplying & Fixing of Floor Standing Rack network Rack - 24U/ 600w/ 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top & Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 22U/ 800d Front MS Door perforated honeycomb 22U/ 600w Rear MS Door (Fully Perforated - Mesh) 22U/ 600w Fan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Cable manager 1U MS with Loops Shelf, Stationery 475mm N/ W PDU 7Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Vertical Cable Channel 50mmW 22U.
Video Conference room 50 Capacity Supply, Installation, Testing & Commissioning of Projector Single 0. 7" DLP® Technology having Resolution WUXGA (1920 x 1200), Brightness - 6000 ANSI Lumens and Contrast Ratio -2000:1, Lamp Life and Type -1, 500/ 3, 500 hours (Normal/ Eco Mode) 370W/ 280W, Projection Lens -F = 2. 46 - 2. 56 f = 22. 82 - 28. 49mm (std lens), Zoom Ratio -1. 25x (std lens) Aspect Ratio -4:3 Native, 16:10 and 16:9 Compatible, DisplayPort connector for digital audio and video signals, Built-in 12V trigger for external wireless module connection, Audio ready with 2x3W stereo speakers.
Supply, Installation, Testing & Commissioning of Motorised front Projection Screen, wide (8ft) X hight (6ft) with Remote Control.
SITC of Full HD Video Conferencing end point with Full HD 1080p60 camera, codec, Microphone Array, cables, and remote control, support long extension twisted cable for Camera and Codec connectivity till 60mtr, Video Standards and Resolutions:It should support H. 323, SIP standards for communications, It should support H. 261, H. 263, H. 264 AVC/ SVC, H. 264 High Profile/ H. 265, It should support 1080p 60 fps, 1080p 30 fps, 720p 60 fps and 720p 30fps, It should support content sharing using standard based H. 239 and BFCP over SIP. It should transmit both people and content both simutaneously to the far end location at 1080p 30fps, Audio Standards and Features:
Supply Installation Testing & Commissioning of Intelligent conference system, Flush mount Gooseneck delegate microphone unit, speaking button, LED for the indication and with Frequency Response 40Hz - 16KHz, Sensitivity -42dB±2dB, Reference sound-receiving distance 20-120cm.
Supply Installation Testing & Commissioning of Intelligent conference system, Flush mount Gooseneck Chairman microphone unit, speaking button and LED for the indication, With president priority key, Chairman microphone should having highest priority and should be able to terminate all microphone. Frequency Response 40-16KHz, Sensitivity -42dB±2dB, Reference sound-receiving distance 20-120cm.
Supply Installation Testing & Commissioning of Intelligent conference system it can support 60 units delegate and chairman microphone, it could be extended upto 200 units microphone by adding more Extension power supply unit, suitable for government, restaurants, conference rooms, training and education, the board of directors of the company meeting room with Frequency response 100 Hz - 16000 Hz, Input Voltage 18V, Limit Switch and Free speech
Supply, Installation, Testing & Commissioning of one Set handheld and one lapel Wireless Mic system set with two transmitters dynamic microphone, Frequency Response 40Hz-15, 000 Hz, Surge mode PLL Phase lock, Dynamic Range >90dB, THD < 0. 5%, S/ N ratio > 90dB, Carrier frequency range 720 - 830 MHz, Power Consumption < 85mA.
Supply Installation Testing & Commissioning of 5"+1. 5" Coaxial Ceiling speaker with ABS cover, 30W, 100V, cutout 185mm, ABS baffle & back cover, metal grille. The Speaker shall have Max SPL > 102 dB, Frequency Response 90-20kHZ. The Speaker shall have Multiple tapping.
Supply Installation testing and comisioning of 250W RMS Dual Channel Class-D Digital Power Amplifier with Switch power technology for power electricity saving, Separate PFC Design for highest reliability, Separate Power Supply System. Amplifier shall have 250W RMS per Channel, Amplifier Output 100V, Supply input AC 220 +/ - 10% - 50/ 60Hz, Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. THD <0. 1%, Frequency Response 40Hz - 20kHz, AC & DC Fuse, SNR >80dB.
Supply, Installation, testing and comissioning of fully programmable 8 IN/ 8 OUT DSP Audio processor with following features:-Excellent sound quality min 96kHz sampling rate, 8 control inputs & 8 remote General purpose TTL outputs, RS232 port for third party control, DSP based feedback killers.
Supply, Installation, Testing & Commissioning of Cable Cubby with HDMI, VGA Input as per technical specification.
Supply, Installation, Testing & Commissioning of 8X8 HDMI Matrix switcher.
Supply, Installation, testing and commissioning of required cable of HDMI, VGA, Audio, power, speaker, Microphone and conenctors as per site requirement etc complete required.
Supplying & Fixing of Floor Standing Rack network Rack - 24U/ 600w/ 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top & Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 22U/ 800d Front MS Door perforated honeycomb 22U/ 600w Rear MS Door (Fully Perforated - Mesh) 22U/ 600w Fan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Cable manager 1U MS with Loops Shelf, Stationery 475mm N/ W PDU 7Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Vertical Cable Channel 50mmW 22U.
Supply, Installation, Testing & Commissioning of Elevator as per Technical Specifications stipulated above including 12 months warranty RESIDENCE BLOCK Type of Elevator (PASSENGER) No of Elevators (Units) (2) Capacity (Pax) (13) Load (Kg) (884) Speed (mtr/ sec) (1) Drive (V3F) Location of Machine Room (Top of Lift Shaft) Travel (mtr) (21) No of Stops (6) Serving Floors (G+5) Shaft Dimension (W x D) (mm) (1900 X 2500) Car Dimension (W x D x H) (mm) (1650 X 1465 X 2100) Pit Depth (mm) (1600) Head Room (mm) (4500) Traction Unit (Permanent Magnet Synchronous Gearless Traction Machine) Main Power Supply (415 Volt 3 Phase 50 Hz AC) Auxiliary Power Supply (220 Volt Single Phase 50 Hz AC) Car Enclosure Details () - Car Ceiling (SS Hairline Finish) - Car Panels (SS Hairline Finish) - Car Flooring (20 mm Recess to be provided (Granite Flooring By Customer)) - Car Illumination (Direct LED Lights) - Car Ventilation/ Fan (Indirect Ventilation) No of Entrance (One Location – Front) Car Entrance (Automatic 2-Panel SOPD SS Hairline Finish) Landing Entrance (Automatic 2-Panel SOPD – SS Hairline Finish) Clear Door Opening (W x H) (mm) (900 x 2100) Door Safety (Full Height Infra Red Curtain) Elevator Control (Duplex) Indication () - Car Indicator (LED Display) - Landing Indicator (LED Display) Features- Direction & Position Indicator in Car- Emergency Alarm- Fireman Switch in Ground Floor- Hands-free Press & Speak Dedicated Intercom- Full Height Infra Red Light Safety Curtain- Pit Ladder- Signal Fixtures in SS Finish- Emergency Light with Rechargeable Battery- Micro Movement LED Based Buttons- Overload Sensor & Indication- Automatic Rescue Device (ARD) - SS Handrail in Car (Rear)
Supply, Installation, Testing & Commissioning of Elevator as per Technical Specifications stipulated above including 12 months warranty BOYS HOSTEL Type of Elevator (PASSENGER) No of Elevators (Units) (2) Capacity (Pax) (16) Load (Kg) (1088) Speed (mtr/ sec) (1) Drive (V3F) Location of Machine Room (Top of Lift Shaft) Travel (mtr) (21) No of Stops (6) Serving Floors (G+5) Shaft Dimension (W x D) (mm) (2150 X 2500) Car Dimension (W x D x H) (mm) (1550 X 1580 X 2100) Pit Depth (mm) (1800) Head Room (mm) (4800) Traction Unit (Permanent Magnet Synchronous Gearless Traction Machine) Main Power Supply (415 Volt 3 Phase 50 Hz AC) Auxiliary Power Supply (220 Volt Single Phase 50 Hz AC) Car Enclosure Details () - Car Ceiling (SS Hairline Finish) - Car Panels (SS Hairline Finish) - Car Flooring (20 mm Recess to be provided (Granite Flooring By Customer)) - Car Illumination (Direct LED Lights) - Car Ventilation/ Fan (Indirect Ventilation) No of Entrance (One Location – Front) Car Entrance (Automatic 2-Panel SOPD SS Hairline Finish) Landing Entrance (Automatic 2-Panel SOPD – SS Hairline Finish) Clear Door Opening (W x H) (mm) (1000 x 2100) Door Safety (Full Height Infra Red Curtain) Elevator Control (Duplex) Indication () - Car Indicator (LED Display) - Landing Indicator (LED Display) Features- Direction & Position Indicator in Car- Emergency Alarm- Fireman Switch in Ground Floor- Hands-free Press & Speak Dedicated Intercom- Full Height Infra Red Light Safety Curtain- Pit Ladder- Signal Fixtures in SS Finish- Emergency Light with Rechargeable Battery- Micro Movement LED Based Buttons- Overload Sensor & Indication- Automatic Rescue Device (ARD) - SS Handrail in Car (Rear)
Supply, Installation, Testing & Commissioning of Elevator as per Technical Specifications stipulated above including 12 months warranty ADMIN BLOCK Type of Elevator (PASSENGER) No of Elevators (Units) (2) Capacity (Pax) (13) Load (Kg) (884) Speed (mtr/ sec) (1) Drive (V3F) Location of Machine Room (Top of Lift Shaft) Travel (mtr) (21) No of Stops (4) Serving Floors (G+3) Shaft Dimension (W x D) (mm) (1900 X 2500) Car Dimension (W x D x H) (mm) (1650 X 1465 X 2100) Pit Depth (mm) (1600) Head Room (mm) (4500) Traction Unit (Permanent Magnet Synchronous Gearless Traction Machine) Main Power Supply (415 Volt 3 Phase 50 Hz AC) Auxiliary Power Supply (220 Volt Single Phase 50 Hz AC) Car Enclosure Details () - Car Ceiling (SS Hairline Finish) - Car Panels (SS Hairline Finish) - Car Flooring (20 mm Recess to be provided (Granite Flooring By Customer)) - Car Illumination (Direct LED Lights) - Car Ventilation/ Fan (Indirect Ventilation) No of Entrance (One Location – Front) Car Entrance (Automatic 2-Panel SOPD SS Hairline Finish) Landing Entrance (Automatic 2-Panel SOPD – SS Hairline Finish) Clear Door Opening (W x H) (mm) (900 x 2100) Door Safety (Full Height Infra Red Curtain) Elevator Control (Duplex) Indication () - Car Indicator (LED Display) - Landing Indicator (LED Display) Features- Direction & Position Indicator in Car- Emergency Alarm- Fireman Switch in Ground Floor- Hands-free Press & Speak Dedicated Intercom- Full Height Infra Red Light Safety Curtain- Pit Ladder- Signal Fixtures in SS Finish- Emergency Light with Rechargeable Battery- Micro Movement LED Based Buttons- Overload Sensor & Indication- Automatic Rescue Device (ARD) - SS Handrail in Car (Rear)
INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted/ Cassette type units with panel and inbuilt drain pump/ slim Ceiling Mounted duct type/ Ceiling Mounted Built in type/ Ceiling Mounted Ductable type units VRV Air Conditioners with cordless/ corded remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating Ceiling Mounted Cassette Unit282-360 CFM/ 0. 63-0. 8 TR, Size 540x540
INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted/ Cassette type units with panel and inbuilt drain pump/ slim Ceiling Mounted duct type/ Ceiling Mounted Built in type/ Ceiling Mounted Ductable type units VRV Air Conditioners with cordless/ corded remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating Ceiling Mounted Cassette Unit400-460 CFM/ 0. 85-1. 0 TR
INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted/ Cassette type units with panel and inbuilt drain pump/ slim Ceiling Mounted duct type/ Ceiling Mounted Built in type/ Ceiling Mounted Ductable type units VRV Air Conditioners with cordless/ corded remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating Ceiling Mounted Cassette Unit500-600 CFM/ 1. 2-1. 3 TR
INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted/ Cassette type units with panel and inbuilt drain pump/ slim Ceiling Mounted duct type/ Ceiling Mounted Built in type/ Ceiling Mounted Ductable type units VRV Air Conditioners with cordless/ corded remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating Ceiling Mounted Cassette Unit565-812 CFM/ 1. 55-1. 6 TR
INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted/ Cassette type units with panel and inbuilt drain pump/ slim Ceiling Mounted duct type/ Ceiling Mounted Built in type/ Ceiling Mounted Ductable type units VRV Air Conditioners with cordless/ corded remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating Ceiling Mounted Cassette Unit750-830 CFM/ 2. 0-2. 1 TR
INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted/ Cassette type units with panel and inbuilt drain pump/ slim Ceiling Mounted duct type/ Ceiling Mounted Built in type/ Ceiling Mounted Ductable type units VRV Air Conditioners with cordless/ corded remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating Ceiling Mounted Cassette Unit800-865 CFM/ 2. 3-2. 5 TR
INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted/ Cassette type units with panel and inbuilt drain pump/ slim Ceiling Mounted duct type/ Ceiling Mounted Built in type/ Ceiling Mounted Ductable type units VRV Air Conditioners with cordless/ corded remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating Ceiling Mounted Cassette Unit1100-1165 CFM/ 3. 0-3. 2 TR
INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted/ Cassette type units with panel and inbuilt drain pump/ slim Ceiling Mounted duct type/ Ceiling Mounted Built in type/ Ceiling Mounted Ductable type units VRV Air Conditioners with cordless/ corded remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating Ceiling Mounted Ductable Unit 1370-1400 CFM/ 3. 5-4. 10 TR
INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted/ Cassette type units with panel and inbuilt drain pump/ slim Ceiling Mounted duct type/ Ceiling Mounted Built in type/ Ceiling Mounted Ductable type units VRV Air Conditioners with cordless/ corded remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating Ceiling Mounted Ductable Unit 1600-1625 CFM/ 4. 5- 4. 55 TR
INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted/ Cassette type units with panel and inbuilt drain pump/ slim Ceiling Mounted duct type/ Ceiling Mounted Built in type/ Ceiling Mounted Ductable type units VRV Air Conditioners with cordless/ corded remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating Ceiling Mounted Ductable Unit 2000-2100 CFM/ 5. 48-6. 36 TR
INDOOR UNITS Supply, installation, testing and commissioning of following Wall Mounted/ Cassette type units with panel and inbuilt drain pump/ slim Ceiling Mounted duct type/ Ceiling Mounted Built in type/ Ceiling Mounted Ductable type units VRV Air Conditioners with cordless/ corded remote controller. Fully Factory assembled, wired and tested Indoor Units as per specifications ans as required to make the system complete. Aluminum fins within the IDU (evaporator unit) shall be coated with polysiloxane based coating Ceiling Mounted Ductable Unit 2542 -2825CFM/ 8. 01- 8. 20 TR
Accessories SITC of Control cum Expansion Kit Required for the above AHU to make the system complete
REMOTE CONTROLLERS Supply, installation, tesing and commissioning of Imported Remote controllers (Corded) for operation of ductable indoor units and AHU's.
REMOTE CONTROLLERS Supply, installation, tesing and commissioning of Imported Remote controllers (Cordless) for operation of Hiwall/ Cassette/ Ceiling Concealed indoor units (For Cassettes Units Only).
Touch screen controller for indoor units controller - VRV Supply, installation, testing and commissioning of touch screen controller (Which is controlled 45 nos. indoor units in terms of ON/ Off Status, temp. Status, Fan Speed, ODU On/ Off Status etc. ) with all accessories and controls.
REFNUTS/ Y-JOINTS Supply, installation, tesing and commissioning of Imported fittings Y-joints insulated, distributer and headers for all Indoor units at both the ends floors layout as per layout drawings.
REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (13/ 19mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers and all external piping with UV coating shall run in cable tray. All interconnecting Copper piping, joints, U bends with polysiloxane based coating shall run in cable tray. (Note: Ref. Piping Length may be review as per site routing) 06. 35 mm with 13 mm thick nitrile rubber insulation
REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (13/ 19mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers and all external piping with UV coating shall run in cable tray. All interconnecting Copper piping, joints, U bends with polysiloxane based coating shall run in cable tray. (Note: Ref. Piping Length may be review as per site routing) 09. 52 mm with 13 mm thick nitrile rubber insulation
REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (13/ 19mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers and all external piping with UV coating shall run in cable tray. All interconnecting Copper piping, joints, U bends with polysiloxane based coating shall run in cable tray. (Note: Ref. Piping Length may be review as per site routing) 12. 70 mm with 13 mm thick nitrile rubber insulation
REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (13/ 19mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers and all external piping with UV coating shall run in cable tray. All interconnecting Copper piping, joints, U bends with polysiloxane based coating shall run in cable tray. (Note: Ref. Piping Length may be review as per site routing) 15. 88 mm with 13 mm thick nitrile rubber insulation
REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (13/ 19mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers and all external piping with UV coating shall run in cable tray. All interconnecting Copper piping, joints, U bends with polysiloxane based coating shall run in cable tray. (Note: Ref. Piping Length may be review as per site routing) 19. 05 mm with 13 mm thick nitrile rubber insulation
REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (13/ 19mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers and all external piping with UV coating shall run in cable tray. All interconnecting Copper piping, joints, U bends with polysiloxane based coating shall run in cable tray. (Note: Ref. Piping Length may be review as per site routing) 22. 22 mm with 19 mm thick nitrile rubber insulation
REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (13/ 19mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers and all external piping with UV coating shall run in cable tray. All interconnecting Copper piping, joints, U bends with polysiloxane based coating shall run in cable tray. (Note: Ref. Piping Length may be review as per site routing) 28. 58 mm with 19 mm thick nitrile rubber insulation
REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (13/ 19mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers and all external piping with UV coating shall run in cable tray. All interconnecting Copper piping, joints, U bends with polysiloxane based coating shall run in cable tray. (Note: Ref. Piping Length may be review as per site routing) 31. 8 mm with 19 mm thick nitrile rubber insulation
REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (13/ 19mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers and all external piping with UV coating shall run in cable tray. All interconnecting Copper piping, joints, U bends with polysiloxane based coating shall run in cable tray. (Note: Ref. Piping Length may be review as per site routing) 34. 92 mm with 19 mm thick nitrile rubber insulation
REFRIGERANT PIPING Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with (13/ 19mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers and all external piping with UV coating shall run in cable tray. All interconnecting Copper piping, joints, U bends with polysiloxane based coating shall run in cable tray. (Note: Ref. Piping Length may be review as per site routing) 41. 30 mm with 19 mm thick nitrile rubber insulation
TRANSMISSION & CONTROL WIRING Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1. 5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller. 2C x 1. 5 Sqmm Cu Cable
TRANSMISSION & CONTROL WIRING Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1. 5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller. Perforated GI Tray with hangers & supports for copper piping (250 mm wide)
Refrigerant-410a Supply, charging & Leackage testing of refrigerant -410a in additional copper piping circuit.
Air Cooled Hi-Wall Split units Providing and fixing of Air Cooled Split airconditioners each comprising an outdoor unit consisting of hermetic Invertor scroll compressor, air cooled condensing unit, Condenser fan etc. with outer casing and indoor fan coil unit (s) consisting of centrifugal fans, fan motor, DX cooling coil, outer casing, filter, control and power panel with corded/ cordless remote control, stablizer etc. both inter connected with copper refrigerant pipe (Compressor capable Approx. 30-40 mtr. copper piping) and drain pipe of required length as given, cabling and wiring, insulation with cross linked polyethelene foam, full charge of refrigerant gas and oil, M. S. base frame, supports etc. complete as per specifications and drawings. The cost shall also include angle iron stands for outdoor units. If A common Servo oil type stablizer than not required stablizer. 2. 0 TR Hi-wall Unit with ref. circuit and approx 30-40 meter of ref. and drain piping & Cabling with sequencing controller (4 Working + 3 Standby) as per specifications & Drawing, For Server/ UPS & Battery Room
SITC of Automatic Voltage stabilizer complete with HI-LOW voltage cut out, TDR and Power wiring from Stabilizer to Unit as per the design & specifications and approval/ instruction of the consultant - 5KVA
Supply, Installation, Testing and Commissioning of Control cum Transmission wiring (4C x1. 5sqmm. ) in suitable conduits between indoor & outdoor units including supply of screened wires, supports, installation, saddles, ties, tags, ferrules, lugs, nuts/ bolts/ hardware etc. complete in all respects as per specifications and any other item required to make the system complete.
SITC of Interconnected Copper Piping (Soft/ Hard both) (1/ 2", 1 1/ 8", 5/ 8", 7/ 8", 9/ 8") For Cassette/ Split Air conditioners, the piping duly insulated with Nitrile insulation tubes of respective sizes and control cabling from Indoor to Outdoor units.
SITC of Power Cabling/ Wiring of Condensing Units of Split Air-conditioners- from Isolators to Condensing Units, including supply of all materials complete in all respects as per specifications and any other item required to make the system complete. 3Cx2. 5 Sqmm.
Supplying with fitting and fixing of angle iron framing made 50MMx50MMx5MM size angle iron for accommodation of 1. 0 TR to 2. 0 TR Window/ Split Type A. C. Machine
DRAIN PIPING Providing & fixing rigid PVC piping complete with fittings, supports as per specifications and pre insulated with 6mm thick closed cell elastomeric nitrile rubber tubular insulation. 25 mm dia
DRAIN PIPING Providing & fixing rigid PVC piping complete with fittings, supports as per specifications and pre insulated with 6mm thick closed cell elastomeric nitrile rubber tubular insulation. 32 mm dia
DRAIN PIPING Providing & fixing rigid PVC piping complete with fittings, supports as per specifications and pre insulated with 6mm thick closed cell elastomeric nitrile rubber tubular insulation. 40 mm dia
Supply, Installation, Testing and commissioning of doble layer canvas connection with fire rating.
Propeller fan Supply, installation, testing and commissioning of Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver & bird screen. 150 mm dia propeller fan, with single phase motor
Propeller fan Supply, installation, testing and commissioning of Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver & bird screen. 300 mm dia propeller fan, with single phase motor
Propeller fan Supply, installation, testing and commissioning of Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver & bird screen. 450 mm dia propeller fan, with single phase motor
Tube Axial Flow fans SITC of Long case Tube axial flow fans, as per specifications and approved makes suitable for three phase operation at 960/ 1450 RPM respectively Normal/ Smoke case. SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M. S. contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/ hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet and fire retardent flexible connections at inlet/ outlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `H' insulation. Motor shall be of high temperature resistance "Class H Smoke Spill" 250° C for 2 hrs. Fan shall be EN 12101-3 Certified & CE/ UL Listed for high temprature. Fan efficiency should not be less than 70 %, noise level should not be more than 80 db @ 3 m distance when measured in hemisperical reverberant room conditions for Normal mode Fans and noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions for Emergency mode Fans. Fans should be as per specification and drawings (As per Vent. Fan Schedule). Normal/ Smoke Exhaust fans at St. Press. of 30 mmWG 7500 CFM smoke extract
SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M. S. contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/ hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet and fire retardent flexible connections at inlet/ outlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `F' insulation. Fan efficiency should not be less than 70 %, noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions. Fans should be as per specification and drawings. (As per Vent. Fan Schedule) (Makeup Air & Pressurization Fans with St. Press. of 40 mmWG/ Make Up Air Fan at 30mm WG) 6500 CFM for Liftwell pressurization, 40 mm S. P.
Evaporative air cooler (Air Washer) Supply, Install, test and commission double skin Evaporative air washer as per specifications, suitable for the following capacity given below at 90% efficiency of evaporative medium. The fan shall be of DIDW centrifugal construction. Packaged Type 4500 CFM, 40 mm (WG) static pressure, Floor/ ceiling mounted (For Kitchen at UG Blocks), Cost to be inclusive of unit isolator
Air Scrubber (DRY Type) DIDW FAN :Kitchen Exhaust Supply, installation, testing and commissioning of DIDW Backword curved horizontal floor mounted fan unit comprising of accurately cut scroll & side plates, heavy gauge with all welded construction, sheet steel fabricated impeller, drive with blower pulley, motor pulley, V-belts, squirrel cage motor complete as per specification (fan-motor efficiency exceeding ASHRAE 90. 1-2007 Criteria). (The bidder shall submit fan performance curves for all fans). The item should be all complete in line with relevant standards, technical specifications of the standards and direction of engineer incharge. 5000 CFM/ 75 mm WG SP (For Kitchen at UG Blocks), Cost to be inclusive of unit isolator
DRY SCRUBBER : Kitchen Exhaust Supply, Installation, Testing and Commissioning of Dry Scrubber comprising of extract air intake section, electrostatic precipitation technology, dry type air cleaner to remove odour, smoke and fumes from exhaust air. Electrostatic section shall be made of 16 gauge galvanised sheet, high bake epoxy powder coated, washable type aluminium mesh filters, stainless steel spiked ionizers to create high voltage DC field, Stainless Steel 316 collector plates which should be alternatively charged positive and negative with large collecting area with 14" deep cell, to work as magnet for charged smoke and oil particles. Average efficiency of 95% and more in single pass as per DOP test method. Electrostatic Precipitator should be able to charge particles from 0. 01 micron to 10 microns through solid state power supply. The system should be fitted with interlock switch for safety. The system should allow connection to a fan section to achieve 500 FPM velocity across the air cleaner. 5000 CFM/ 75 mm WG SP (For Kitchen at UG Blocks), Cost to be inclusive of unit isolator
Site Fabricated Duct - GI Sheet Metal duct Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter, vanes, hangers, Gripple supportsetc. ) in accordance with the approved shop drawings and specifications, and shall also confirm to the BIS specifications. The duct shall be fabricated at site for to suit pieces. 0. 63mm (24 gauge) GSS
Site Fabricated Duct - GI Sheet Metal duct Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter, vanes, hangers, Gripple supportsetc. ) in accordance with the approved shop drawings and specifications, and shall also confirm to the BIS specifications. The duct shall be fabricated at site for to suit pieces. 0. 8 mm (22 gauge) GSS
Factory Fabricated Duct - GI duct Supply, Installation, balancing and commissioning of factory fabricated GSS sheet metal ducts (rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter, vanes, hangers, Gripple supportsetc. ) in accordance with the approved shop drawings and specifications, and shall also confirm to the BIS specifications. The duct shall be fabricated at site for to suit pieces. 0. 63mm (24 gauge) GSS
Factory Fabricated Duct - GI duct Supply, Installation, balancing and commissioning of factory fabricated GSS sheet metal ducts (rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter, vanes, hangers, Gripple supportsetc. ) in accordance with the approved shop drawings and specifications, and shall also confirm to the BIS specifications. The duct shall be fabricated at site for to suit pieces. 0. 8 mm (22 gauge) GSS
Supply, Fabrication, Installation and testing of Insulated Al. Flexible ducts in accordance with the approved shop floor drawings and specifications and shall also confirm to the BIS specifications. 200 mm Dia.
Supply, Fabrication, Installation and testing of Insulated Al. Flexible ducts in accordance with the approved shop floor drawings and specifications and shall also confirm to the BIS specifications. 150 mm Dia.
Grilles/ Diffusers Supplying and fixing of Extruded aluminium supply and return air grilles/ diffusers/ louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. Aluminium supply air grilles with damper.
Grilles/ Diffusers Supplying and fixing of Extruded aluminium supply and return air grilles/ diffusers/ louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. Aluminium return air grilles without damper.
Grilles/ Diffusers Supplying and fixing of Extruded aluminium supply and return air grilles/ diffusers/ louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. Linear air grilles (150 MM wide)
Grilles/ Diffusers Supplying and fixing of Extruded aluminium supply and return air grilles/ diffusers/ louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. Aluminium supply air collar damper
Grilles/ Diffusers Supplying and fixing of Extruded aluminium supply and return air grilles/ diffusers/ louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. AI Volume control dampers for ducts
Fresh Air/ Exhaust Air Louvers Supplying and fixing of extruded aluminium louvres with frame bird screeen, mounting arrangement etc. as per specifications and drawings. Fresh Air/ Exhaust Louvers
MOTORIZED FIRE AND SMOKE DAMPERS Supplying, fixing, Testing and commissioning of fire dampers in suppy air duct/ main branch and return air path as and where required of required size i/ c control wiring, the damper shall be motorized combination fire and smoke damper (spring return type) of approved make of atleast 120 minute fire rating and as per the specifications as detailed earlier in the relevant sections. The fire damper shall be complete with electronic temperature sensor and electrically operated actuator. The fire dampers shall be located in the supply/ return air ducts, at all fire rated crossovers (shafts/ walls etc. ) The control panel will be such located that the reset can be easily done These combination smoke and fire dampers shall be interlocked with the building management system for fire detection/ HVAC and shall trip/ close in the event of fire/ smoke in the respective zone. Bare Fire Dampers with 400 mm sleeve
MOTORIZED FIRE AND SMOKE DAMPERS Supplying, fixing, Testing and commissioning of fire dampers in suppy air duct/ main branch and return air path as and where required of required size i/ c control wiring, the damper shall be motorized combination fire and smoke damper (spring return type) of approved make of atleast 120 minute fire rating and as per the specifications as detailed earlier in the relevant sections. The fire damper shall be complete with electronic temperature sensor and electrically operated actuator. The fire dampers shall be located in the supply/ return air ducts, at all fire rated crossovers (shafts/ walls etc. ) The control panel will be such located that the reset can be easily done These combination smoke and fire dampers shall be interlocked with the building management system for fire detection/ HVAC and shall trip/ close in the event of fire/ smoke in the respective zone. Control panel actuator, including Electrical, spring type actuator, remote indication of the fire damper position.
MOTORIZED FIRE AND SMOKE DAMPERS Supplying, fixing, Testing and commissioning of fire dampers in suppy air duct/ main branch and return air path as and where required of required size i/ c control wiring, the damper shall be motorized combination fire and smoke damper (spring return type) of approved make of atleast 120 minute fire rating and as per the specifications as detailed earlier in the relevant sections. The fire damper shall be complete with electronic temperature sensor and electrically operated actuator. The fire dampers shall be located in the supply/ return air ducts, at all fire rated crossovers (shafts/ walls etc. ) The control panel will be such located that the reset can be easily done These combination smoke and fire dampers shall be interlocked with the building management system for fire detection/ HVAC and shall trip/ close in the event of fire/ smoke in the respective zone. Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers.
MOTORIZED FIRE AND SMOKE DAMPERS Supplying, fixing, Testing and commissioning of fire dampers in suppy air duct/ main branch and return air path as and where required of required size i/ c control wiring, the damper shall be motorized combination fire and smoke damper (spring return type) of approved make of atleast 120 minute fire rating and as per the specifications as detailed earlier in the relevant sections. The fire damper shall be complete with electronic temperature sensor and electrically operated actuator. The fire dampers shall be located in the supply/ return air ducts, at all fire rated crossovers (shafts/ walls etc. ) The control panel will be such located that the reset can be easily done These combination smoke and fire dampers shall be interlocked with the building management system for fire detection/ HVAC and shall trip/ close in the event of fire/ smoke in the respective zone. Sealing the openings around the sleeve of the fire dampers with approved fire sealant, as per the recommendations of the manufacturer and specifications.
Supply, Installation, Testing and commissioning of doble layer canvas connection with 1/ 2 hr. fire rating as per specification.
INSULATION WORKS THERMAL INSULATION: SITC of Thermal insulation material for Duct insulation shall be closed cell cross linked polyethylene foam. Thermal conductivity of the insulation material shall not exceed 0. 032 W/ moK at an average temperature of 25oC. Density of the material shall be 25-30 Kg/ m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6: 1989 for fire propagation test and as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability as per DIN 52615 shall not exceed 0. 15ng/ Pa. Sec. m. 32 mm thick insulation with 2 layesr coat 7 mile cloth insulation or starbond insulation (for exposed duct)
INSULATION WORKS THERMAL INSULATION: SITC of Thermal insulation material for Duct insulation shall be closed cell cross linked polyethylene foam. Thermal conductivity of the insulation material shall not exceed 0. 032 W/ moK at an average temperature of 25oC. Density of the material shall be 25-30 Kg/ m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6: 1989 for fire propagation test and as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability as per DIN 52615 shall not exceed 0. 15ng/ Pa. Sec. m. 13 mm thick insulation (Supply Air Ducts)
INSULATION WORKS THERMAL INSULATION: SITC of Thermal insulation material for Duct insulation shall be closed cell cross linked polyethylene foam. Thermal conductivity of the insulation material shall not exceed 0. 032 W/ moK at an average temperature of 25oC. Density of the material shall be 25-30 Kg/ m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6: 1989 for fire propagation test and as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability as per DIN 52615 shall not exceed 0. 15ng/ Pa. Sec. m. 9 mm thick insulation (Return Air Duct)
ACOUSTIC LINING IN THE SUPPLY/ RETURN DUCTS Supply and Application of acoustic lining within the supply air duct Nitrile Rubber/ Insusound material as per specifications and drawings. 15mm thick (For Duct)
Exposed Roof Insulation Supply, application of under deck insulation of roof exposed to direct sun, with Thermal insulation material for Under-deck insulation shall be closed cell cross linked polyethylene foam. Thermal conductivity of the insulation material shall not exceed 0. 032 W/ moK at an average temperature of 25°C. Density of the material shall be 25-30 Kg/ m3. The product shall have temperature range of –40 °C to 105°C. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6: 1989 for fire propagation test and as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability as per DIN 52615 shall not exceed 0. 15ng/ Pa. Sec. m. 13 mm thick Under deck insulation as per the specifications detailed above in the section
AHU/ Fan Panel Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following LT panels fabricated out of 14 guage CRCA sheet steel in cubical formationwith reinforecment of suitable size angle iron and channel T iron flats. All steel material used in the construction of panels shall be powder coated. A solid busbar shall be provided at the bottom of the panel with two connecting eyes for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase, 4 wire supply system. All the hardware used in the fabrication of the panel shall be galvanized with zinc passivation. The panel shall be compartmentalized to accommodate one feeder in each compartment. A vertcal cable alley of suitable width shall be provided to serve on or two vertical feeder sections. Also the opening between the busbar chamber and the feeder section shall be shrouded with bakelite/ hylam sheet with min. 3 mm thickness. The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/ NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire. All smoke/ vent. fan panel the starters shall have suitable facility to operate with fire sensing control modules. HVAC AHU/ Fan Panel MCC-01, 02 Incoming/ Outgoing 1 no. 6-10 A, TP MPCB (with DOL starter) Phase indicating lights with control fuses. Breaker ON/ OFF/ TRIP indicating lights. The base frame shall be 75 mm x 5 mm. (Optional) Panel as described above and in drawings.
HVAC Ahu/ Fan Panel MCC-03 Incoming 1 no. 50 amp MCB Phase indicating lights with control fuses. Breaker ON/ OFF/ TRIP indicating lights. Bus Bars 80 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves. Outgoings 2 nos. 6-10 A, TP MPCB (with DOL starter) incl. 1 no. MPCB Spare 2 nos. 4-6. 3 A, TP MPCB (with DOL starter) incl. 1 no. MPCB Spare The base frame shall be 75 mm x 5 mm. Panel as described above and in drawings.
HVAC Ahu/ Fan Panel MCC-04 Incoming 1 no. 50 amp MCB Phase indicating lights with control fuses. Breaker ON/ OFF/ TRIP indicating lights. Bus Bars 80 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves. Outgoings 2 nos. 6-10 A, TP MPCB (with DOL starter) The base frame shall be 75 mm x 5 mm. Panel as described above and in drawings.
Supply, installation, testing & commisioning of Copper conductor cables PVC sheathed/ XLPE Insulation, armoured cables of 1. 1 KV grade with termination glands and GI earthing, identification tags, clamps and saddles etc. 3Cx04 Sqmm
Supply, installation, testing & commisioning of Copper conductor cables PVC sheathed/ XLPE Insulation, armoured cables of 1. 1 KV grade with termination glands and GI earthing, identification tags, clamps and saddles etc. 4Cx06 Sqmm
Supply, installation, testing & commisioning of Copper conductor cables PVC sheathed/ XLPE Insulation, armoured cables of 1. 1 KV grade with termination glands and GI earthing, identification tags, clamps and saddles etc. 4Cx04 Sqmm
Supply, installation, testing & commisioning of Copper conductor, PVC insulated, PVC sheathed/ XLPE armoured cable of 1. 1 KV grade (Which is Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers & Touch screen controller). 8C x 1. 5 Sqmm
Supply, installation, testing & commisioning of cable termination of above cables with copper lugs & flameproof brass compression glands on both the ends with inhibting compound etc. complete as required. 3Cx04 Sqmm
Supply, installation, testing & commisioning of cable termination of above cables with copper lugs & flameproof brass compression glands on both the ends with inhibting compound etc. complete as required. 4Cx06 Sqmm
Supply, installation, testing & commisioning of cable termination of above cables with copper lugs & flameproof brass compression glands on both the ends with inhibting compound etc. complete as required. 4Cx04 Sqmm
Supplying and installing following size of perforated G. I. cable trays, G. I. bends with perforation not more than 17. 5%, joined with connectors, suspended from the ceiling with suitable suspenders including G. I. bolts & nuts, painting of suspenders etc. complete as required. 101 mm. Width x 50mm. Depth x 1. 6mm. Thickness.
Supplying and installing following size of perforated G. I. cable trays, G. I. bends with perforation not more than 17. 5%, joined with connectors, suspended from the ceiling with suitable suspenders including G. I. bolts & nuts, painting of suspenders etc. complete as required. 152 mm. Width x 50mm. Depth x 1. 6mm. Thickness.
Providing and fixing following size of G. I. wire on surface or in recess for loop earthing alongwith the existing surface/ recessed conduit/ submain wiring/ on cable tray/ on surface including G. I. clamps etc. complete as required. 6 SWG G. I. wire
Any addl. Item whenever required will be from the Assam P.W.D. SOR for Civil ,Sanitary & water supply and Electrical works for 2013-14. Rate to be quoted in amount for any addl. item not included in the above items. Estimated Amount Rs. 6,13,885.00
Shree Gautam Construction Co Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid