Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC 1 3104 KUNJ GALI RAM NAGAR EXTN LONI ROAD SHAHDARA DELHI 32 | SHAHDARA | DELHI | 110032 | L1 | Accepted-AOC Restricted amount to Rs. 3,20,018/- only. | |
| 2 | L2₹4.5 L+₹2,199 (0.49%)Rejected-Finance A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | L2 | Rejected-Finance Not L1 |
Tender Value
₹4.5 L
EMD Value
₹9,050
Closing Date
17 May 2022, 12:00 pmClosed
EEE-II Shah(S)
OFFICE OF THE Ex. ENGINEER (ELECT)-II 2 nd Floor Technical Laboratory Near NH-24 Ghazipur Delhi
Repair and Renovation of E.I and fans at MandCW Vishwakarma park laxmi nagar in ward no13E under shd. South zone
2022_EDMC_115296_1
EE (Elect)-II//2022-23/1.1
Open Tender
Electrical Works
Item Rate
30 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹500
₹9,050
30 Jan 2024
9 May 2022
18 May 2022
9 May 2022
17 May 2022
9 May 2022
Amount
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group-C
supply and fixing of following sizes medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required a)25 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3x2.5 sq.mm
3x4 sq.mm
3x6 sq.mm
Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required.5/6 amps switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
supply of XLPE PVC Sheathed Al. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098(Part-I) of following sizes:2 x 10 sq.mm
4 x 25 sq.mm
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal)size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as require
supply and fixing of Metal box 180mm x 100 mmx 60 mm deep (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover infront including providing and fixing 6 pin 5/6 &15/16A socket outlet and 15/16A piano type switch ,connection painting etc as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker single pole suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 Amp rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required
S& F of compartment cubical type panel board duly powder coated made out of16 SWG MS Sheet with insulated aluminium bus bar i/c interconncetion copper wiring arrangment for mounting for switch gears, change over swichtes, MCCB i/c making the foundation brick work/ angle iron frame on floor/wall with proper locking arrangement etc. complete as required at site. Depth 30 to 60 cm
Providing and fixing following Rating and breaking capacity MCCB WithThermomagnatic release and Terminal Spreader in existing cubical panel board including drillingholes in cubical panel ,making connection etc as required.disconnector fuse switch unit inside the existing panel board with ISI Marked HRC fuses including drilling holes in cubile panel making connection etc as reqd. 200A,16KA,TPMCCB
100A ,16KA,TPMCCB
Providing and fixing following capacity TP&N disconnector fuse switch unit,sheet enclosure type with side handle operation , ISI mark, making connections, etc. as required.200A ,TP&N
Supply and fixing of 4.5 Kg DCP with COCO2 fire extinguisher (wall mounting type) gas cartridge fire extinguisher (conforming to IS: 2171 with cylinder fully charged)
SITC of 60W LED Flood Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd.. (b) Total system wattage =60 watt +/- 5% c) Luminaire Efficacy>=100 Lm/w d) Power Factor>=0.95s f) Protection IP-66
supply and fixing of 400mm single phase swing wall fan as reqd.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A
SITC of single phase/three phase monoblock pump set complete with allaccessories workable on 240/415V ,50HZ ac supply 2hp single phase pump set head from 12-30 meter suction and delivery 25*25mm
P&F of water/weather proof junction/pole box made out of 16 SWG MS sheet steel of size200x150x100mmdeep dully painted complete with one No SP-MCB(6to32Amp) and neutral link & locking arrangement etc as reqd.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.180 mm X 100 mm X 60 mm deep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
SITC of surface mounting LED luminaire suitable for 1X20 watt LED rating complete with extruded aluminium batten prewired with high efficient LEDs with the following: a) Total System Wattage 20 ±5% Watt b) Luminaries effucacy ≥ 100 lumens/watt c) Power factor ≥ 0.95
SITC of 45W LED street Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd... (a) Total system wattage =45watt +/- 5% b) Luminaire Efficacy>=100 Lm/w c) Power Factor>=0.95 d) Protection IP-66
Supply and fixing of 32 mm dia G. I pipe ( Medium class) 1 mtr long bracket 1/c wiring with 2.5 sq mm copper conductor wire as required.
supply and laying of 6 sq mm aluminium conductor PVC insulated flat twin core W/P wire complete as required
Supply of 15" (380mm) sweep 1400 rpm exhaust fan fan heavy duty complete with shutters, blades etc as reqd.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Providing and fixing of invertor of 2000 VA 2 Nos 150 AH Batteries with trolley suitable for keeping 2 Nos Battery and 1 no inverter i/c wiring & connections etc as reqd.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Rewinding of AC ceiling fan / Exaust fan of all sizes and make i/c oiling, greasing as required.
SITC of Desert cooler in metalic body of 18mm gauge ,12 inch deep capacity with fan of 18 inch size having 3 blades heavy duty motor with iron angle stand as per required size and design
SITC of 150 ltr water cooler with following specifications are:- a) Cooling Capacity ltrs /hr .b) Eco - Friendly ( Non CFC Refrigent) c) water tank sheet material and thickness .-Stainless Steel ( Grade AISI 3 04 ), Thickness >= 0.8 d) water tank cover and lid bottom sheet material - High Impact Polystrene (HIP) e) Conformity to IS : 1475 latest.
M/S. A.K. Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .