| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC OLD HASIMARA DISTT JALPAIGURI WEST BENGAL PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹27.7 L+₹3.8 L (16.0%)Rejected-Finance OLD HASIMARA PO HASIMARA DISTT ALIIPURDUAR WB PIN 735215 | HASIMARA | ALIPURDUAR | WEST BENGAL | 735215 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹27.9 L+₹4.0 L (16.8%)Rejected-Finance HAMILTONGANJ NETAJI PALLY NEAR ICE FACTORY DISTT ALIPURDUAR WEST BENGAL 735 214 | ALIPURDUAR | WEST BENGAL | 735214 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹28.1 L+₹4.2 L (17.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹28.7 L+₹4.8 L (20.1%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
29 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) HASIMARA
GE (AF) HASIMARA PO HASIMARA DIST ALIPURDUAR PIN 735215
REPAIR / REPLACEMENT OF RUSTED WATER SUPPLY LINE AT AFS UNDER GE (AF) HASIMARA
2020_MES_357649_1
C/8405/20-21/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹54,000
Yes
27 Aug 2020
2 Jul 2020
30 Jul 2020
2 Jul 2020
29 Jul 2020
16 Jul 2020
60 days
Amount
SCHEDULE 'A' PART-I Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Taking up 80 mm bore cast iron pipes (including all fittings) with spigot and socket end and lead joints including burning out lead joints and recovering lead complete and keeping serviceable pipes in safe custody for re-use in the work and removing remaining pipes with fittings from site of work complete all as specified and directed by the Engineer-in-Charge. (Note: Excavation and earth work work shall be measured and paid seperately)
All as per serial item No. 04 above but 100 mm bore complete ditto
M & L for Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 80/100/150mm complete all as specified and directed.
M & L for 80 mm bore, ductile iron pipe (K-7), socket and spigot end as per IS:8329 with internal cement mortar linning and external bitumen coating for potable water supply with rubber ring joints including cost of rubber rings as per IS:5382 (1985), giving satisfactory hydraulic field testinbg and commissioning as per technical specification etc laid in trenches complete all as specified and directed by the Engr-in-charge. (Note : Excavation and earth work shall be measured and paid separately under respective items in this schedule).
All as per serial item No. 07 above but for 100 mm bore of pipe complete ditto
M & L for ductile iron fittings for spigot and socketed pipe, such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and pigot) collars, caps and plugs etc upto 200mm bore complete all as specified and directed.
M & L for Rubber gasket tyton joint for ductile iron spigot and socket pipe of 80 mm bore complete complete all as specified and directed.
M & L for Rubber gasket tyton joint for ductile iron spigot and socket pipe of 100 mm bore complete complete all as specified and directed.
Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 25mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 40mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 50mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Supply, laying, connection and testing, 25mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
Supply, laying, connection and testing, 32mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
Supply, laying, connection and testing, 63mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed
Supply, laying, connection and testing, 25mm outer dia 3- layer PP-R Polypropylene random copo-lymer) concealed pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors etc complete all as specified and directed
Supply, laying, connection and testing, 32mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors etc complete all as specified and directed
Supply, laying, connection and testing, 50mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors etc complete all as specified and directed
S & F in repair 25 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
S & F in repair 32 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
S & F in repair 40 mm outer dia, PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
S & F 80mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket including taking out existing one complete all as specified and directed.
S & F 100mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket including taking out existing one complete all as specified and directed.
M & L for construction of brick masonry valve pit of size 50 cm x 50 cm x 50 cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation & earth work in soft/loose soil and demolition of existing one complete as specified and directed all as per relevant TD drawing. (Note : Drawing not attached with the tender document. However, the same can be seen in GE/AGE E/M office during working hours)
All as per serial item No. 27 above but of size 90cmx90cmx90cm (Internal) complete ditto.
All as per serial item No. 27 above but of size 120cmx120cmx120cm (Internal) complete ditto.
M & L for Rubber gasket or fibre board gasket joint suitable for 100 mm bore CI flanged pipe & fittings with necessary nut, bolts, washer etc complete all as specified and directed.
M & L for run lead joint for CI spigot and socket pipes & fittings, 100mm bore with new lead complete all as specified and directed
M/S BIJAY KUMAR SHIVA
MAJUMDER ENTERPRISE
M/S BISHAL ENTERPRISES
SHRI D P AGARWAL
M/S ANIL KUMAR BAUL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .