Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | MS FORWARD BUILDERS E 32/10/KKD L2₹29.9 L+₹60,318 (2.06%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹29.9 L+₹62,197 (2.12%)Rejected-Finance PO BUD BUD DIST BURDWAN WEST BENGAL PIN 713 403 | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L3 | Rejected-Finance Higher rate quoted | |
| 4 | L4₹31.8 L+₹2.5 L (8.55%)Rejected-Finance | L4 | Rejected-Finance Higher rate quoted |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
21 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_509795_1
8400-780/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
PANAGARH
Class D, Cat b (i)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹70,000
Yes
27 Apr 2022
22 Feb 2022
23 Mar 2022
22 Feb 2022
21 Mar 2022
7 Mar 2022
60 days
Amount
Air Conditioner M&L for taking down window type Air Conditioner of 1.0 TR/1.5 TR / 2.0 TR, cleaning completely the cooling coil initially with hand blower, spraying with soap water solution and finally clean with clear water and refixing at same location with complete testing all as directed by the Engr-in-Charge.
Dismantling covers of out-door and in-door units of split type Air Conditioner of capacity 1.0TR/1.5TR/2.0TR, cleaning completely the condenser coil and cooling coil initially with hand blower, spraying with soap water solution and finally clean with clear water, re-fixing the covers in same position complete as directed by the Engineer-in-Charge.
Carrying out pressure leak test by Nitrogen gas pressure for detecting leak in condensing unit refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging as per existing and and transporting & carrying out T&P required at site for work of following capacity ACs, water coolers & refrigerators complete all as specified and directed. Note :- The rate under mentioned items included for transpotation of AC to & from work shop as approved by Engr -In -Charge. (a) Window type AC of capacity up to 2.0 TR
(b) Split type AC of capacity of capacity up to 2.0 TR.
(c) Refrigerator of capacity up to 340 ltr
(d) Water cooler of capacity 40 Ltr to 150 ltrs
Dismantling of blower fan motor cutting burnt coils and taking out from the AC unit, cleaning and rewinding using supper enameled copper wire of existing size and gauge including insulation materials change of bush (front and rear) made out of gun metal and reassembling all accessories and testing complete all as directed for the following :- (a) Window type AC of capacity 1.0 TR/1.5TR/2.0TR
(b) Split type AC of capacity 1.0 TR/1.5TR/2.0TR
Labour only for collecting the complaints of various wards/departments etc pertains to split/window type Acs of any capacity/make from concern JE of AGE E/M, attendending these at site to asses the actual fault after opening of ACs and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE all as directed. (Note: Spare parts shall be measured and paid separately under appropriate items)
(a) Running capacitor 40/36 mfd
(b) Running Capacitor 4/6 mfd
(c) Capillary Tube (copper) as per existing size.
(d) Filter strainer
(e) Starting relay 1622
(g) Air filter made of plastic frame and nylon net
(h) Thermostat switch make - Shriram/Ranutral/Indfos or equivalent
(i) Contactor relay for split type AC.
(j) Running capacitor 45/50 Mfd + 6 MFD up to 2 ton split type AC
(k) Blower motor for window/Split Type AC upto 2 Ton capacity (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
(l) Remote suitable for window/Split AC
(m) Front grill (as per existing make such as Blue Star, carrier, Usha, Voltas,LG, Amtrex etc)
(n) PCB Board for split type AC
(o) Rubber bushing for blower motor
(p) Swing motor for split type AC of capacity 1.0 TR/1.5TR/2.0TR.
(q) Display assembly for spilit type AC
(r) Starting capacitor 100/120 mfd (Universal/ SARADA or equivalent)
(s) Sensor for Indoor unit.
(t) Copper made cooling/condensor coil 5/8 inch
(u) Modular pin top 20 Amps (Make:- havells/Anchor or equivalent)
(v) Standard outer cover
(w) Fan blade set
(x) Brand new fan motor 1/5 HP Make:-Frogmaster/Free flow of equivalent
S&F in repair sealed unit Compressor rotary type for window/split AC upto 1.5 Ton capacity complete all as specified and directed. Make : Samsung/Kirloskar/Emarson compland/ Wirlpool.
S&F in repair sealed unit Compressor rotary type for window/split AC upto 2.0 Ton capacity complete all as specified and directed Make : Samsung/Kirloskar/Emarson compland/ Wirlpool.
S&F in repair flexible drain pipe for split type AC complete all as specified and directed.
Complete painting to the unit by two coats of spray paint with enamel painting as directed after cleaning the unit assembly incl with castic soda wash for the evaporator and condensor for window type air conditioners all as directed by Engr- In -Charge.
M&L for servicing ,cleaning, greasing, oiling , checking of electric wiring,relay,contactor etc and replacement of defective wiring of any make by Window/Split AC all as directed.
S&F in repair of PCB board suitable for 1.5/2 Ton Window/Split Ac complete all as directed.
M&L in repair of voltage stablizer of 4 KVA Cap range between 130 to 280 Volt sutable for 1.5 Ton window/split AC complete all as specified and directed
S&F in repair of voltage stablizer of 5 KVA Cap range between 130 to 280 Volt sutable for 2 Ton window/split AC complete all as specified and directed
M&L for scrapping out old bubbled paint ,cleaning the surface,levelling,spray painting with one coat of synthetic enameled paint over one coat of primer as per existing colour to Window/Split AC/Water cooler/Deep fridger/Refrigerator/Geyser of any make and type at site including writing MES/SM/SL No with black enameled paint complete all as specified and directed. Note:- Paint will be carried out at site by bringing compressor machine rate quated deemed to be included complete.
M&L for opening/cutting hole in brick wall sutable for window type AC 1.5/2 Ton and making good disturbed surface area complete with cement plaster and masonary work reqd at site and made air tight to opening with the thermocoal material all round the window AC etc complete all as specified and directed by Engr-in-charge.
Disconnecting and taking out existing defective MCB of any description & in any make and suppling and fixing new MCB ,single pole, 240 v ,32 Amps, 'B' series all as directed. Make:-Havells/L&T/Schneider or eqvt
Disconnecting and taking out existing defective MCB of any description & in any make and suppling and fixing new MCB ,single pole, 240 v ,20 Amps, 'B' series all as directed. Make:-Havells/L&T/Schneider or eqvt
S&F split out door fins type aluminium condensor of capacity 2 Ton complete all as specified and as directed. Make:-Samsung/Hitachi/Voltas/LG etc.
S&F PVC sheathed copper conductor cable of size 4 sqmm x 3 core, 1100 volt, ISI marked complete all as directed. Make:- Havells/L & T/Stranded/Polycab.
S&F PVC sheathed copper conductor cable of size 6 sqmm x 3 core, 1100 volt, ISI marked complete all as directed. Make:- Havells/L & T/Stranded/Polycab.
Refrigerator Labour only for collecting the complaints of various wards/departments etc pertains to Refrigerators of any capacity/make from concern JE of AGE E/M, attendending these at site to asses the actual fault after opening of refrigerator and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE all as directed. (Note: Spare parts shall be measured and paid separately under appropriate items. The rate under mentioned items included for transpotation of refrigerator to & from work shop as approved by Engr -In -Charge.
(a) Condenser coil for upto 340 Ltrs cap
(b) Pin/Thread type lamp holder
(c) Bulb 15 watt (Pin/Thread type). Make:- Philips
(d) Ice tray
(e) Open type relay with overload protector
(f) Thermostat auto defrost. Make:- Indofoss/Renutrol
(g) Capillary tube (copper) as per existing.
(h) Chill tray
(j) 3 Pin 15 Amps plug top 240 Volt
(k) Ice Chamber up to 340 Ltr.
(l) Vegetable box
(m) Bimetal Relay
(n) Frost free fan motor
(o) Timer
(p) Relay 1/6 HP Make:- Whirlpool/Kevinator/Godrej
(q) Relay box type
(r) Over load protector 1/6 HP Make:- Whirlpool/Kelvinator/Godrej
(s) Refrigerator door lock with key
(t) Door megnatic gasket for upto 340 Ltrs cap
(u) Light switch upto 340 Ltrs cap
(v) Cooling coil for upto 340 ltrs
(w) Brand new fan motor 1/5 HP Make:- Frogmaster/Free flow or equivalent
(x) Compressor as per existing upto 220 Ltrs. Make:- Tecumsesh/Kirlosker/Emarson
(xi) Compressor as per existing upto 340 Ltrs. Make:- Tecumsesh/Kirlosker/Emarson
Water Cooler Labour only for collecting the complaints of various wards/departments etc pertains to water coolers of any capacity/make from concern JE of AGE E/M, attendending these at site to asses the actual fault after opening of water coolers and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE all as directed. (Note: Spare parts shall be measured and paid separately under appropriate items. The rate under mentioned items included for transpotation of water cooler to & from work shop as approved by Engr -In -Charge).
(a) Push type tap copper alloy chromium plated 15/20 mm bore.
(b) Rubber lining for top cover gasket (3 metre approx each cooler)
(c) Starting relay suitable for 5/8 HP motor make SHRIRAM or equivalent
(d) Starting capacitor 80/100 mfd (Make Universal/ SARADA or equivalent)
(e) Thermostat (Make : Indofons/shriram/or equivalent
(f) Float valve Brass with fly nut screwed as per existing.
(g) Over load protector Make : SHRIRAM or equivalent
(h) Capilary tube as per existing size (Copper).
(j) Blower motor as per existing.
(k) CP Basin tray.
(l) Running capacitor 15 mfd (Make Universal/ SARADA or equivalent).
(m) Running capacitor 10 mfd (Make Universal/ SARADA or equivalent).
(n) Running capacitor 36 mfd (Make Universal/ SARADA or equivalent).
(o) Fan blade assembly as per existing
(p) Wiring kit
(q) Drain stainless steel tray with drain elbow and connector
(r) PVC hose connection pipe both ends having brass coupling threaded for 15mm bore
(s) PVC drain hose pipe of size 32mm dia
(t) Compressor as per existing upto 120/150 Ltrs. Make:- Tecumsesh/kirloskar/Emarson
Supply and charging refrigeration gas R-22 for Split/window AC/water cooler/Deep fridger/AC plant of cap 7.5 TR, testing leak in system and commissioning all as specified and directed. Make: Mafron or equivalent
Supply and charging refrigeration gas R-134A for Split/window AC, testing leak in system and commissioning all as specified and directed. Make: Mafron or equivalent
Supply and charging refrigeration gas R-410 for Split/window AC, testing leak in system and commissioning all as specified and directed. Make: Mafron or equivalent
S&F in repair for sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 Amps 240 volt. (Make: Havells/Legrand/L&T).
Taking down out door unit of 1.5TR/2.0 TR capacity removing unserviceable AC stand/angle iron bracket fixing new AC stand/angle iron bracket in repair fixing to wall by foundation bolts refixing the out door unit connection the suction and discharge line complete testing and running all as directed by the Engr-in-charge.
Dismantling and taking out voltage stabllizer transformer unit, auto transformer varier, electric circult board, all cable connections, including repairing/replacement of push on switch, transistor, capacitor, relay transistor, diode, condenser, voltmeter, PVC connector, indicator lamp, cutout, MCB complete parts along with testing commissioning and trasportation charges from site to workshop all as directed. :-
(a) Upto 2 KVA capacity
(b) 03 KVA to 5 KVA capacity
Replacement of following spare parts for 1 KVA to 2 KVA capacity stabalizers (a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
Replacement of following spare parts for 4 KVA to 5 KVA capacity stabalizers (a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
Geyser Taking down geyser of 50/35/25 ltrs capacity from its position after disconnecting connection , opening of geyser to take out inner tank , soldering at two to three places to stop leakage and also scraping , brushing down old paint with emery paper and apply two coats of white paint using spray machine spray painting and complete all as specified and as directed.
Dismantling of exist unserviceable apparatus plate and S&F in repair new steel tank match to the existing one with rubber gasket suitable for 35 ltrs geyser, complete all as specified and as directed.
All as per item No 107.00 mentioned here-in-above but for 25 ltrs capacity complete all as specified and directed.
S&F in repair glass wool suitable for geyser, complete all as specified and as directed.
Dismantling of exist unserviceable heating element triangular from geyser and S&F in repair new heating element of 1.5/2.0 kw 230 volt at including testing and complete connection all as specified and as directed.
Dismantling of exist unserviceable heating element round from geyser and S&F in repair new heating element of 1.5/2.0 kw 230 volt at including testing and complete connection all as specified and as directed.
Dismantling of existing old unserviceable thermostat 60 degree C to 90 degree C for diffrent type geyser and S&F in repair new thermostat matching to exist one including all connection,testing etc. complete all as specified and as directed.
S&F in repair PVC Connection pipe 15 mm dia with two Nos brass chromium plated union alongwith Hexagonal nuts adoptor,rubber washer etc for water line all as directed. (Make - Sona or equivalent as approved by GE) (a) 450mm long
(b) 600mm long
S&F in repair PVC Connection pipe heavy pipe (sutable to hold 60 to 100 degree C temprature Hot water) of 15 mm dia with brass flexible tube along with CP Hexagonal nuts adoptor,rubber washer etc for water line all as directed. (Make - Sona or equivalent as approved by GE) (a) 450mm long
(b) 600mm long
S&F fusible plug for geysers melting at 95 degree C ( any special required for fixing plug shall be supply without any financial implication after taking down old unserviceable fusible plug complete all as directed.
S&F indicators lamp Red/ Green, round /rectangular type after taking down old unserviceable indicator lamp complete all as directed.
S&F insulated flexible multi strand copper conductor nominal area 2.5 Sqmm, 3 core after taking out old inserviceable cable complete all as directed. (Make -Havells/HPL/Polycab or equivalent ISI Mark).
Taking down stop valve and S&F new stop valve CP and fixed of 15 mm bore complete all as specified and directed.
Taking down old rusted clamp,nut,bolt,washer complete set and S&F new clamp, nut, bolt, washer complete set for hanging of geyser complete all as specified and directed
Deep Fridger Labour only for collecting the complaints of various wards/departments etc pertains to deep fridger of any capacity/make from concern JE of AGE E/M, attendending these at site to asses the actual fault after opening of deep fridger and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE all as directed. (Note: 1. Spare parts shall be measured and paid separately under appropriate items 2. The rate under mentioned items included for transpotation of deep fridger to & from work shop as approved by Engr -In -Charge).
(a) Over load relay and capacitor
(b) Fan motor set 4"size
(c) Fan motor set 6" size
(d) Thermostate
(e) Filter
(f) Compressor reciprocating upto 300 Ltrs. Make:-Tecumsesh/kirloskar/Emarson compland/Whirlpool.
(g) Compressor reciprocating upto 425 Ltrs. Make:-Tecumsesh/kirloskar/Emarson compland/Whirlpool.
Dismantling of fan motor of any size and any make from the deep fridger, cleaning and rewinding using super enameled copper wire of existing size and gauge incl insulation materials change of bush( front and rear) made out of gun metal and reassembling all as accessories and testing complete all as directed.
COLD STORAGE / PACKAGE TYPE /WALK-IN-COOLER PLANTS of CAPACITY 7.5TR Labour only for collecting the complaints of various wards/departments etc pertains to cold storage/package type/walk in cooler plant of cap 7.5 TR of any capacity/make from concern JE of AGE E/M, attendending these at site to asses the actual fault after opening of deep fridger and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE all as directed. (Note: 1. Spare parts shall be measured and paid separately under appropriate items) 2. The rate under mentioned items included for transpotation of cold storage/package type/walk in cooler plant of cap 7.5 TR to & from work shop as approved by Engr -In -Charge).
(a) Condenser fan motor with blower set blade of 7.5 TR capacity for cold storage all as directed
(b) Copper pipe 5/8" suitable for 3 ton capacity sealed compressor of cold storage plant of 7.5TR
(c) Insulation Thermo vax 100mm thick for 7.5 TR capacity for cold storage all as directed
(d) Single phase preventor Model : VSP Make : L&T
(e) Timer control assembly for cold storage plant 7.5 TR
(f) Expansion valve CP-100 make : Sporlan or equivalent for cold storage plant 7.5TR
(g) LP and HP Cut out make : Indfoss or equivalent for cold storage plant 7.5TR
(h) Evaporator coil for fan motor complete with blade set suitable for cold storage plant 7.5TR
(j) Service valve Model scroll type for cold storage plant 7.5TR
(k) Suction valve for cold storage plant 7.5TR
(l) Discharge valve for cold storage plant 7.5TR
(m) Thermostat for cold storage plant 7.5TR
(n) Air break (Power) contactor 3 TF 3200-OA AC 11 rating -16 Amps capacity Make : SIEMENS or equivalent
(o) Electronic timer series ETR-350,240v AC 50/60 HZ Contact 240v AC/28VDC 5 A (Resistive) Star-Delta 3.30 second and 6-60 second .Make : L & T or equivlanet
(p) Door lock and assembly for cold storage plant Make :- Blue Star of 7.5TR by new one all as directed
(q) Fuse 20 Amps
(r) Condenser fan motor.Make: GE or equivalent for package type AC plant 7.5TR
(s) Solenoid valve and cutout switch with N2 testing for cold storage / package type 7.5 TR capacity air conditioning all as directed
(t) Drier core Make Danfoss for package type A/C plant 7.5TR
(u) Pillar block bearing for AHU blower motor of package type 7.5 TR capacity air conditioning
(v) liquid line filters, driers Type IDK 083 of package type 7.5 TR capacity air conditioning
(w) 'V' belt for blower of package type AC plant
(x) Fan blade heavy duty suitable for package type AC plant 7.5 TR
(y) Starting relay 30 A of range 3.5 to 5 Amps. Make: Siemens or equivalent
(z) Sealed type compressor . MAKE:- COPELAND/KIRLOSKAR/ TECUMSHAH/CARRIER/ SRIRAM (inclusivee of cutting ,transporting, reconnecting and testing the compressor and commssioning at site).
M&L for rewiring of control panel complete, providing inter lock system and serving of electronic PCB Board and display for package type AC plant Make : Blue star 7.5TR
S&F for gasket entire door of walk in cooler capacity of 7.5 TR etc complete all as speci fied and as directed.
S&F single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete Make Standard Cat part No. DSDPUSN 020 or equivalent with and incluidng single pole MCB 20 Amps Make Standard "B Series Cat No. DSMSBPF006-032 or equivalent for incoming and out going control. Make Standard or equivalent
S&F in repair wiring for circuit/submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed as required 2x6.0 sqmm + 1x4.0 sqmm earth wire in concealed PVC condute complete all as directed. Note:- Two run of cable considered as One RM.
S&F in repair wiring for circuit/submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed as required 2x6.0 sqmm + 1x4.0 sqmm earth wire in concealed PVC casing caping complete all as directed. Note:- Two run of cable considered as One RM.
S&F in repair wiring for circuit/submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed as required 2x4.0 sqmm + 1x2.50 sqmm earth wire in concealed PVC condute complete all as directed. Note:- Two run of cable considered as One RM.
S&F in repair wiring for circuit/submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed as required 2x4.0 sqmm + 1x2.50 sqmm earth wire in concealed PVC casing caping complete all as directed. Note:- Two run of cable considered as One RM.
MS FORWARD BUILDERS E 32/10/KKD
ROY ENTERPRISE
M/S BISWAS AND KUNDU CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .