GEMC-511687794317189
Awarded to ARTEE FLOW CONTROLS PRIVATE LIMITED
₹36.3 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Supply of HC LEL Open Path Gas Detector along with all required interconnecting triad cables and glands, calibration kits, alignment kits, etc as per Data Sheet No B650-000-YD-DS-8105 | Honeywell / 02104-N-XSSA | 90271000 | 3 Nos | 479,603.92 | 1,438,811.76 |
| Supply of HC LEL Open Path Gas Detector along with all required interconnecting triad cables and glands, calibration kits, alignment kits, etc. as per Data Sheet No. B650-000-YD-DS-8105 | Honeywell / 02104-N-XSSA | 90271000 | 3 Nos | 479,603.92 | 1,438,811.76 |
| Supply of H2S Open Path Gas Detector along with all required interconnecting triad cables and glands, calibration kits, alignment kits, etc. as per Data Sheet No. B650-000-YD-DS-8105 | Honeywell / FGM-6300 + 2’’ Pipe mounting | 90271000 | 6 Nos | 90,510.72 | 543,064.32 |
| Supply of weatherproof IP65 field panel housing controller, vendor system, gas detector channels, hooter reset switches suitable for non-hazardous area per Data Sheet B650-000-YD-DS-8105 | Honeywell / GMC-SC-RS-A (12 No. Card)+ GMC-FRK-A + Prewired panel | 90271000 | 1 Nos | 186,023.46 | 186,023.46 |
| Supply of 2 nos. hooter with each hooter having different tone for HC and H2S leak detection shall be located on top of local panel of the gas detection system. | Sudhir/equi / Flame proof Hooter,24 VDC Supply,IIA/IIB LM6 Material with noise level of app. 110 db | 90271000 | 2 Nos | 12,390 | 24,780 |