Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-Finance | ₹37.5 L | L1 | Accepted-Finance Lowest |
| 2 | L2₹37.8 L+₹29,680 (0.79%)Accepted-Finance | ₹37.8 L+₹29,680 (0.79%) | L2 | Accepted-Finance Other than Lowest |
| 3 | L3₹38.8 L+₹1.3 L (3.55%)Accepted-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹38.8 L+₹1.3 L (3.55%) | L3 | Accepted-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
15 Jul 2021, 6:00 pmClosed
GE (U) Chandimandir
GE (U) Chandimandir Chandimandir Cantt Panchkula (HR)
GE(U)/CHM-20/2021-22- PROVN OF REPAIRS CUM MAINTENANCE AND PREVENTIVE MAINTENANCE OF LT PANELS, FEEDER PILLAR BOXES AND OTHER CONNECTED ACCESSORIES AND ALLIED WORKS AT VARIOUS SUB STATIONS AT CHANDIMANDIR
2021_MES_452125_1
GE(U)/CHM-20/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Chandimandir Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (U) Chandimandir
₹80,000
Yes
24 Jul 2021
16 Jun 2021
17 Jul 2021
16 Jun 2021
15 Jul 2021
1 Jul 2021
Amount
Excavation in trenches for foundations, laying / taking out of cables, erecting of poles etc, in any type of soil, not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr in width and getting out, complete all as specified and as directed.
Returning, filling in soils, in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed
Removing excavated soils to a distance exceeding 50 metres and not exceeding 100 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point.
Dry course sand , filled in trenches under and over underground cables as cushioning to cable complete all as specified and as directed.
Supplying and laying unreinforced precast concrete cable cover (ISI marked), class LV, type I, flat, size 250mm x 150mm x 40mm, in trenches over sand as protection to cable complete all as specified and as directed.
40mm bore (internal dia) steel water tubing, galvanized light grade, laid in trenches /fixed to wall/ along pole or laid in trenches or under roads etc as protection to cable, with all fittings and fixtures like mild steel flat iron clamps of appropriate size and shape, nuts, bolts and washers as approved by Engineer-in-Charge complete all as specified and as directed, with and including taking up/down old damaged steel pipe and removing from site of work complete all as directed.
All as per the description of serial item-6 here-in-above but of 80mm bore (internal dia)
MCCB four pole 400Amps, 415 volts, 50HZ breaking capacity not less than 36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics = 100% of I cu, in replacement (taking down old damaged MCCB) complete all as specified and as directed. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-8 here-in-above but of 320 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-8 here-in-above but of 250 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-8 here-in-above but of 200 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-8 here-in-above but of 160 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-8 here-in-above but of 125 Amps. Make : L&T/ABB/Schnieder/Siemens
All as per the description of serial item-8 here-in-above but of 100 Amps. Make : L&T/ABB/Schnieder/Siemens
Change over switch ON LOAD type, 415 volt, 50 Hz, AC 4 pole, in steel metal enclosure, capacity 600 Amps rated current manually operated conforming to IS : 13947 or latest edition with high thermal and dynamic strength to withstand short circuit current level of 80 KA rms, in replacement, (taking down old damaged change over switch) complete all as specified and as directed.
Straight through joint (jointing kit) heat shrinkable for XLPE/PVC insulated and sheathed aluminium conductor underground cable, 1100 volts 3.5/4 core 400 sqmm, supplied, jointed and tested, below normal ground in trenches or any other location including necessary earthwork as required, complete all as specified and as directed.
All as per the description of serial item-16 here-in-above but for cable 240 Sqmm to 300 Sqmm
All as per the description of serial item-16 here-in-above but for cable 185 Sqmm
All as per the description of serial item-16 here-in-above but for cable 95 Sqmm to 120 Sqmm
All as per the description of serial item-16 here-in-above but for cable 50 Sqmm to 70 Sqmm
Disconnecting and taking out old damaged/defective LT cable from trenches or taking down from poles or taking out from pipes below or above ground level, or for rerouting of cable aluminium conductor 1100 volts grade, size 400 sqmm 3.5 core testing for serviceability of cable cutting and segregating serviceable portion of the cable to be reused/incorporated vide serial item No 29 herein after and removing unserviceable cable from site of work including taking out cable cover and pipe, complete all as specified and as directed. NOTE : Excavation and earth work shall be measured and paid for separately.
All as per the description of serial item-21 here-in-above but for of size 300 sqmm 3.5 core testing for serviceability of cable cutting and segregating serviceable portion of the cable to be reused/incorporated vide serial item No 30 herein after. NOTE : Excavation and earth work shall be measured and paid for separately.
All as per the description of serial item-21 here-in-above but for of size 240.00 sqmm 3.5 core testing for serviceability of cable cutting and segregating serviceable portion of the cable to be reused/incorporated vide serial item No 31 herein after. NOTE : Excavation and earth work shall be measured and paid for separately.
All as per the description of serial item-21 here-in-above but for of size 185.00 sqmm 3.50 core testing for serviceability of cable cutting and segregating serviceable portion of the cable to be reused/incorporated vide serial item No 32 herein after. NOTE : Excavation and earth work shall be measured and paid for separately.
All as per the description of serial item-21 here-in-above but for of size 150.00 sqmm 3.50 core testing for serviceability of cable cutting and segregating serviceable portion of the cable to be reused/incorporated vide serial item No 33 herein after. NOTE : Excavation and earth work shall be measured and paid for separately.
All as per the description of serial item-21 here-in-above but for of size 120.00 sqmm 3.50 core testing for serviceability of cable cutting and segregating serviceable portion of the cable to be reused/incorporated vide serial item No 34 herein after. NOTE : Excavation and earth work shall be measured and paid for separately.
All as per the description of serial item-21 here-in-above but for of size 95.00 sqmm 3.50 core testing for serviceability of cable cutting and segregating serviceable portion of the cable to be reused/incorporated vide serial item No 35 herein after. NOTE : Excavation and earth work shall be measured and paid for separately.
All as per the description of serial item-21 here-in-above but for of size 70.00 sqmm 3.50 core testing for serviceability of cable cutting and segregating serviceable portion of the cable to be reused/incorporated vide serial item No 36 herein after. NOTE : Excavation and earth work shall be measured and paid for separately.
Laying only, jointing and testing LT cable PVC insulated armoured, heavy duty 1100 volts grade with aluminium conductor of size 400.00 Sqmm 3.50, in trenches or thorugh ducts/ pipes or fixed to poles or walls through pipes under road, jointing to OH conductor, LT panle, main swithces etc, serviceable cable as retrieved vide serial item No 21here in above complete all as directed. NOTE : (i) Unit rate quoted is inclusive of cuttin chases,if any in wall or under floor. (ii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-29 here-in-above but of size 300.00 sqmm 3.50 core, serviceable cable as retreived vide serial item No 22 herein above NOTE : (i) Unit rate quoted is inclusive of cuttin chases,if any in wall or under floor. (ii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-29 here-in-above but of size 240.00 sqmm 3.50 core , serviceable cable as retreived vide serial item No 23 herein above. NOTE : (i) Unit rate quoted is inclusive of cuttin chases,if any in wall or under floor. (ii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-29 here-in-above but of size 240.00 sqmm 3.50 core , serviceable cable as retreived vide serial item No 24 herein above. NOTE : (i) Unit rate quoted is inclusive of cuttin chases,if any in wall or under floor. (ii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-29 here-in-above but of size 150 sqmm 3.50 core, serviceable cable as retreived vide serial item No 25 herein above NOTE : (i) Unit rate quoted is inclusive of cuttin chases,if any in wall or under floor. (ii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-29 here-in-above but of size 120 sqmm 3.50 core, serviceable cable as retreived vide serial item No 26 herein above NOTE : (i) Unit rate quoted is inclusive of cuttin chases,if any in wall or under floor. (ii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-29 here-in-above but of size 95.00 sqmm 3.50 core, serviceable cable as retreived vide serial item No 27 herein above NOTE : (i) Unit rate quoted is inclusive of cuttin chases,if any in wall or under floor. (ii) Excavation and earth work if required shall be measured and paid for seperately.
All as per the description of serial item-29 here-in-above but of size 70.00 Sqm, 3.50 core, serviceable cable as retreived vide serial item No 28 herein above NOTE : (i) Unit rate quoted is inclusive of cuttin chases,if any in wall or under floor. (ii) Excavation and earth work if required shall be measured and paid for seperately.
Supply, laying , jointing and testing LT underground electric cable XLPE insulated, PVC sheathed armoured heavy duty 1100 volts grade heavy duty multystranded aluminium conductor laid in trenches / ducts or passing through under road or fixed to poles or walls complete all as specifed and as directed of following size :-- NOTE : Excavation and earth work if required shall be measured and paid for seperately.
Cross sectional area 70.00 sqmm 3.50 core
Cross sectional area 95.00 sqmm 3.50 core
Cross sectional area 120.00 sqmm 3.50 core
Cross sectional area 150.00 sqmm 3.50 core
Cross sectional area 185.00 sqmm 3.50 core
Cross sectional area 240.00 sqmm 3.50 core
Cross sectional area 300.00 sqmm 3.50 core
Cross sectional area 400.00 sqmm 3.50 core
Material and labour for cutting existing bituminous/cement concrete road/hard standing/pavement of size 30 cm x 30cm for passing through the cables/pipes and surrounding /filling the entire cut space with cement concrete 1:3:6 type C-I after laying of pipe/cable and finishing the top surface fair and even complete all as specified and as directed.
Electric panel doors fabricated out of mild steel sheet of thickness as directed by Engineer-in-Charge, made to shape and size as per existing with proper closing/opening arrangements including necessary welding/ fabrication as required and fitted/fixed in position including taking down old damaged / defective panel doors and removing from site of work, with and including two coats of aluminium paint over a coat of red oxide/zinc chrome primer, complete all as specified and as directed.
Aluminium bus bar of different size and capacity as per site requirement and as directed by Engineer-in-Charge including PVC insulating materials and cutting, welding as required, making holes and fixed in position including taking down old bus bar and removing from site of work, all as directed.
Earthing complete with galvanized iron or steel plate electrode 600mm X600mm X 6.0 mm burried directly in ground vertially in a pit of depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth of not less than 1.50m below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to with and including GI/ Steel strip of size 32mmx6mm upto a length of 7.50 metre by means of bolts, nuts, check nuts & washers of galvanized iron /steel, earth strip protected by and including galvanized steel pipe light grade of bore 40 mm (internal dia) & connected to main control board / switch board or any other electrical equipment complete all as shown in electrical plate No : 3 MES SSR including necessary excavation & earth work, disposal of surplus soil not exceeding 50m, in any type of soil. (The rate also includes for cost of charcoal & salt in alternate layers of 15 cm thickness, 20 mm bore internal dia GI/steel pipe light grade) for watering, funnel, wire mesh, PCC chamber in cement concrete (1:3:6) type C-1, 40mm thick RCC(1:2:4) type B-0, reinforced with XPM of weight not less than 4.00 kg/Sqm and mild steel frame of angle 50mmx50xxx6mm and testing on competion including dismantling / taking out existing earthing and removing dismantling / taken out materials outside the defence land complete all as directed.
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 1000 Amps 415 Volts, 50 Hz, four pole mannual draw out microprocessor based, with LCD display with complete set of LSIG protection with self power release with fault indication and with 20 trip history with time stamping suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed Make : ABB/Schnieder/L&T/Siemens
All as per the description of serial item-42 here-in-above but of 800 Amps -ditto- Make : ABB/Schnieder/L&T/Siemens
Supply, installation, testing and commissioning of out door type LT feeder pillar/ distribution boards thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08.
The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel. These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit including 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6 mm for grouting purpose in PCC 1 :2:4 type B1 [ using 20 mm graded stone aggregate). The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) 4 Nos heat shrink insulated bus bar of 1.5 times of incoming MCCB including all connection with aluminum strip. (b) Incoming :- MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu -01 Nos Make : ABB/Schnieder/L&T/Siemens. (c) Outgoing :- MCCB four pole 415 Volts ,50 HZ, 160Amps microprocessor based withLIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 05 Nos . Make : ABB/Schnieder/L&T/Siemens. (d) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (e) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear to be used in the panel will be of same make.
Supply, installation, testing and commissioning of out door type LT feeder pillar/ distribution boards thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel.
These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit including 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6 mm for grouting purpose in PCC 1 :2:4 type B1 [ using 20 mm graded stone aggregate for foundation). The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories:- (a) 4 Nos heat shrink insulated bus bar of 1.5 times of incoming MCCB including all connection with aluminum strip. (b) Incoming:- MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu -01 Nos Make : ABB/Schnieder/L&T/Siemens. (c) Outgoing :- (i) MCCB four pole 415 Volts ,50 HZ, 100Amps microprocessor based withLIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 03 Nos . Make : ABB/Schnieder/L&T/Siemens. (ii) MCCB four pole 415 Volts ,50 HZ, 125 Amps microprocessor based withLIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 02 Nos . Make : ABB/Schnieder/L&T/Siemens. (iii) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (iv) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear to be used in the panel will be of same make.
Supply, installation, testing and commissioning of out door type LT feeder pillar/ distribution boards thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel.
These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit including 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6 mm for grouting purpose in PCC 1 :2:4 type B1 [ using 20 mm graded stone aggregate for foundation). The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) 4 Nos heat shrink insulated bus bar of 1.5 times of incoming MCCB including all connection with aluminum strip. (b) Incoming :- MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu -01 Nos Make : ABB/Schnieder/L&T/Siemens. (c) Outgoing :- (i) MCCB four pole 415 Volts ,50 HZ, 250 Amps microprocessor based withLIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 02 Nos . Make : ABB/Schnieder/L&T/Siemens. (ii) MCCB four pole 415 Volts ,50 HZ, 125 Amps microprocessor based with LIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 03 Nos . Make : ABB/Schnieder/L&T/Siemens. (d) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (e) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear to be used in the panel will be of same make.
Supply, installation, testing and commissioning of out door type LT feeder pillar/ distribution boards thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel. These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit including 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6 mm for grouting purpose in PCC 1 :2:4 type B1 [ using 20 mm graded stone aggregate for foundation).
These accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit including 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6 mm for grouting purpose in PCC 1 :2:4 type B1 [ using 20 mm graded stone aggregate for foundation). The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) 4 Nos heat shrink insulated bus bar of 1.5 times of incoming MCCB including all connection with aluminum strip. (b) Incoming:- MCCB four pole, 415 Volts, 50 HZ, 400 Amps microprocessor based with LIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu -01 Nos Make : ABB/Schnieder/L&T/Siemens. (c) Outgoing :- (i) MCCB four pole 415 Volts ,50 HZ, 160 Amps microprocessor based with LIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 03 Nos . Make : ABB/Schnieder/L&T/Siemens. (ii) MCCB four pole 415 Volts ,50 HZ, 100 Amps microprocessor based withLIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu - 03 Nos . Make : ABB/Schnieder/L&T/Siemens. (d) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (e) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear used in the panel will be of same make.
Supply, installation, testing and commissioning of out door type LT feeder pillar/ distribution boards thermoplastic polycarbonate IP 65 in accodance with EN 60 529, dust proof, rust proof, water proof & weatheproof, metering panel shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extinguishing, UV resistant, Silica and halogen free recyclable material, glow wire tested at 9600 C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total insulated with system. The manufacture of boar/panel shall submit a copy of CPRI test report of degree of ingress protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane ; while the gasket shall be internally embedded. The manufacture of board/ panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC60439-1. The report shall mention the following tests performed and passed out satisfactory:- (a) Degree of protection. (b) Temperature rise. (c) Dielectric Properties. (d) Short circuit withstand current. (e) Effectiveness of protective circuits. (f) Clearance & creepage distance. (g) Mechanical operation. Polycarbonate enclosure shall be fire retardant & self extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 part 3,UL subject 94 for Flammability V-2. It shall be tested at Glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures/ boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. The lid closing and opening shall be done by quick fastering spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel.
The board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. Each board shall have individual routine test report of the manufacture & the panel board will have the following accessories. (a) 4 Nos heat shrink insulated bus bar of 1.5 times of incoming MCCB including all connection with aluminum strip. (b) Incoming:- MCCB four pole, 415 Volts, 50 HZ, 320 Amps microprocessor based with LIG&LSIG protection and fault indication on MCCB, breaking capacity 36 KA with Ics = 100% Icu -01 Nos Make : ABB/Schnieder/L&T/Siemens. (c) Outgoing :- (i) MCCB four pole 415 Volts ,50 HZ, 160 Amps microprocessor based withLIG&LSIG protection and fault indication on MCCB breaking capacity 36 KA with Ics = 100% Icu - 02 Nos . Make : ABB/Schnieder/L&T/Siemens. (ii) MCCB four pole 415 Volts ,50 HZ, 100 Amps microprocessor based withLIG&LSIG protection and fault indication on MCCB breaking capacity 36 KA with Ics = 100% Icu - 02 Nos . Make : ABB/Schnieder/L&T/Siemens. (iii) MCCB four pole 415 Volts ,50 HZ, 63 Amps microprocessor based withLIG&LSIG protection and fault indication on MCCB breaking capacity 36 KA with Ics = 100% Icu - 02 Nos . Make : ABB/Schnieder/L&T/Siemens. (e) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three) (f) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed. Note :-All the switchgear to be used in the panel will be of same make.
Supply, installation testing and commissioning of out door type LT feeder piller box CPRI approved openable from front & rear double door type,dust and vermin proof, fabricated out of 3.15 mm CRCA sheet of size 0.75 x 0.50 x 0.50 duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and MS channel frame of ISMC 75 at base of panel only and 04 Nos legs of not less than 50 cm long each below the base of panel made of angle iron 50 x 50 x 6mm for grouting purpose and grouted in PCC 1:2:4 type B1( using 20 mm graded stone aggregate) alongwith incoming MCCB four pole, 415 volts, 25 KA, 50 Hz, 200 amps - 01 Nos including 4 Nos heat shrink insulated 200 Amps rated aluminum bus bar suitable for 4 Nos outgoing 25 sqmm to 35 sqmm 3.5/4 core XLPE armoured cable complete all as specified and directed by Engr-in- charge, including dismantling / taking out old feeder pillar box and removing from site of work, complete all as directed. Make : ABB/Schnieder/L&T/Siemens.
Double wall corrugated HDPE duct pipe of 100mm outer dia conforming to IS:14930 Pt-II with antirodant and non flame propergating properties of make and colour as approved by Engineer-in-Charge with fittings as protection to cable, laid in trenches or fixed to poles/walls complete all as specified and as directed.
Supply and fix in replacement multimeter flush mounitng type, digital type,0 -500 volts and 0-750 amp, 50 Hz, 96 x 96 mm complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement godreg type lock for LT panel matching with the existing complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement APFC panel relay 8 steps, 415 volts, complete all as specified and directed. Make : L&T, Cat No- CS909020000 or equivalent as approved by GE.
Supply and fix in replacement APFC panel relay 12 steps, 415 volts, complete all as specified and directed. Make : L&T, Cat No - CS909030000 or equivalent as approved by GE.
Suppy and fix in replacement capacitor duty connector MO C12.5, 440 volt, 3 Ph, 50 Hz, detatching type early make contacts, seprate termination for damping resistors, encapsulated damping resistor assembly, built in surge suppressor, low pick up VA consumption complete all as specified and directed by Engr-in- Charge. Make : L&T, Cat No - CS96321 or equivalent as approved by GE.
Suppy and fix in replacement capacitor duty connector MO C25, 440 volt, 3 Ph, 50 Hz, detatching type early make contacts, seprate termination for damping resistors, encapsulated damping resistor assembly, built in surge suppressor, low pick up VA consumption complete all as specified and directed by Engr-in- Charge. Make : L&T, Cat No - CS96322 or equivalent as approved by GE.
Supply and fix in replacement heavy duty capacitors cylindrical series 12.5 kVAr rating, 440 volt complete all as specified and directed by Engr-in-Charge. Make : L&T or equivalent as approved by GE .
Supply and fix in replacement heavy duty capacitors cylindrical series 25 kVAr rating, 440 volt complete all as specified and directed by Engr-in-Charge. Make : L&T or equivalent as approved by GE.
Supply and fix in replacement MCB 40 Amps, D curve 3 pole, 415 volt complete all as specified and directed by Engr-in-Charge. Make : L&T or equivalent as approved by GE.
Supply and fix in replacement MCB 32 Amps, D curve 3 pole, 415 volt complete all as specified and directed by Engr-in-Charge. Make : L&T or equivalent as approved by GE.
Supply and fix in replacement MCB 63 Amps, C curve 4 pole, 415 volt complete all as specified and directed by Engr-in-Charge. Make : L&T or equivalent as approved by GE.
M&L in repair for GI strip 32 x 6 mm for earthing complete all as specified and directed by Engr-in-Charge.
M&L for drawing out of LT ACB 4 pole 415 volts of capacity 630/800/1000/1200 amps form the LT panel and servicing/ repair the same for proper functioning, lightening the loose hardware part and loose connection and lubricating the all mechanism, clean all contacts with fine emery paper and CRC, replacement of burnt/defective parts applying petroleum jelly on the contacts, refixing in the original position and checking for proper functioning complete all as specified and directed by Engr -in-Charge. Note - Defective parts will be measured and paid seprately under the respective items.
Supply only fixed contacts as per sample suitable for 630/800/1000/1200 amps capacity of LT ACB of any make complete all as specified and directed by Engr-in-Charge.
Supply only moving contacts as per sample suitable for 630/800/1000/1200 amps capacity of LT ACB of any make complete all as specified and directed by Engr-in-Charge.
Supply only spring charging and operating mechanism as per sample suitable for 630/800/1000/1200 amps capacity of LT ACB of any make complete all as specified and directed by Engr-in-Charge.
Supply only shunt trip coil 240 volts as per sample suitable for 630/800/1000/1200 amps capacity of LT ACB of any make complete all as specified and directed by Engr-in-Charge.
Supply only CT as per sample suitable for 630/800/1000/1200 amps capacity of LT ACB of any make complete all as specified and directed by Engr-in-Charge.
Material & Labour for entire process of welding exising hings of LT panel to make panel door functional properly (opening & closing) and painting of LT Panel (Outdoor/Indoor) completely with one coate of synthetic enamel, spray paint of shade and tint or colour to match the eixisting or as approved by GE, on front, rear, sides, top outside and front shutter inside and marking / writing panel No of pattern, size and colour as approved by Engineer-in-Charge complete all as specified and as directed. Average Area of one panel to be painted 8.00 Sqm to 10.00 Sqm
Note: Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit Revised in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
Vasudeva Trading Co.
R D Bansal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .