| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-Finance | ₹13.5 L | L1 | Accepted-Finance BQR Conditions Satisfied |
| 2 | L2₹16.0 LAccepted-Finance | ₹16.0 L | L2 | Accepted-Finance BQR Conditions Satisfied |
| Sl No | Description | Qty | Unit | Sangeetha Enterprises | SRI AYYAPPAN ENTERPRISES |
|---|---|---|---|---|---|
| 1.00 | Charges for loading and unloading of 400 NB M.S ERW pipe from store to workspot. | 6.2 | Ton | 20,460 ₹24,142.80 | 17,738.2 ₹20,931.08 |
| 2.00 | Charges for dismantling and re-erection of wornout, damaged punctured 400 NB (450/600) pipe in Bearing cooling water four distribution header from 600 Return header line near unit I cooling tower about 5 mtr height. (Each distribution header 6.500 mtr) (Rate per mtr). | 26 | mtr | 4,94,000 ₹5.8 L | 4,18,918.5 ₹4.9 L |
| 3.00 | charges for dismantling corroded and damaged 100 X 50 support channel in Bearing cooling water 400 NB distribution header line. | 448 | Kg | 7,168 ₹8,458.24 | 5,376 ₹6,343.68 |
| 4.00 | Charges for fabrication and erection of 100 x 50 support channel in bearing cooling waer 400 NB distribution line | 0.45 | Ton | 21,504 ₹25,374.72 | 18,697.28 ₹22,062.79 |
| 5.00 | Charges for providing necessary scaffolding arrangements for dismantling and erection of the 400 NB pipes at 5 mtr elevation from the ground and removing after completion of works. | 2 | Sets | 25,200 ₹29,736 | 22,048 ₹26,016.64 |
| 6.00 | ACW Return 400 NB distribution header pipe line Dismantling of worn out, damaged and punctured 1 no. 400 NB M.S spool pipe and 2 nos 400 NB M.S bend in cooling tower distribution return header line of unit I (4 sets of 24 mtr length) | 4 | Sets | 32,400 ₹38,232 | 27,868 ₹32,884.24 |
| 7.00 | Fabrication of 400 NB M.S bend by cutting the pipe to the required length, grinding, making V groove, joining and welding. | 4 | Sets | 56,000 ₹66,080 | 47,624 ₹56,196.32 |
| 8.00 | Erection of fabricated 400 NB M.S bend 2 nos and 1 no 400 NB MS pipe by welding, in cooling tower distribution header line (1 set = 3 nos, So 4 sets x 3 nos = 12 nos). | 12 | Nos | 48,000 ₹56,640 | 36,636 ₹43,230.48 |
| 9.00 | charges for fabrication/machining of 400 NB MS flanges by gas cutting the flange, drilling, surface finishing etc., including charges for T&P and cost of consumables etc.,of return distribution header pipe line (4 nos.) | 4 | Nos | 6,000 ₹7,080 | 5,020 ₹5,923.60 |
| 10.00 | Charges for fabrication of T piece 400 NB M.S ERW pipe having flange at one end and other end to be connected at 600 NB M.S ERW pipe including consumable and T & P Charges. | 4 | Nos | 32,000 ₹37,760 | 25,976 ₹30,651.68 |
Tender Value
Refer Docs
EMD Value
₹10,800
Closing Date
4 Mar 2026, 2:00 pmClosed
CE/TTPS
O/o CE/TTPS
TTPS Operation Circle CAD ACWPH Unit I Dismantling and Renewal of worn out, corroded and punctured pipe in cooling tower trough inlet 400 NB distribution header pipes 400 NB distribution pipes, 80 NB MS tapping spool pipes from 600 NB return header
2026_EB_660163_1
CE/SE/O/TTPS/Spec.No.307/25-26
Open Tender
Miscellaneous Works
30 days
TTPS
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹10,800
Yes
6 Mar 2026
18 Feb 2026
5 Mar 2026
18 Feb 2026
4 Mar 2026
18 Feb 2026
Charges for loading and unloading of 400 NB M.S ERW pipe from store to workspot.
Charges for dismantling and re-erection of wornout, damaged punctured 400 NB (450/600) pipe in Bearing cooling water four distribution header from 600 Return header line near unit I cooling tower about 5 mtr height. (Each distribution header 6.500 mtr) (Rate per mtr).
charges for dismantling corroded and damaged 100 X 50 support channel in Bearing cooling water 400 NB distribution header line.
Charges for fabrication and erection of 100 x 50 support channel in bearing cooling waer 400 NB distribution line
Charges for providing necessary scaffolding arrangements for dismantling and erection of the 400 NB pipes at 5 mtr elevation from the ground and removing after completion of works.
ACW Return 400 NB distribution header pipe line Dismantling of worn out, damaged and punctured 1 no. 400 NB M.S spool pipe and 2 nos 400 NB M.S bend in cooling tower distribution return header line of unit I (4 sets of 24 mtr length)
Fabrication of 400 NB M.S bend by cutting the pipe to the required length, grinding, making V groove, joining and welding.
Erection of fabricated 400 NB M.S bend 2 nos and 1 no 400 NB MS pipe by welding, in cooling tower distribution header line (1 set = 3 nos, So 4 sets x 3 nos = 12 nos).
charges for fabrication/machining of 400 NB MS flanges by gas cutting the flange, drilling, surface finishing etc., including charges for T&P and cost of consumables etc.,of return distribution header pipe line (4 nos.)
Charges for fabrication of T piece 400 NB M.S ERW pipe having flange at one end and other end to be connected at 600 NB M.S ERW pipe including consumable and T & P Charges.
Charges for dismantling and re-erection of wornout, damaged punctured 450 NB bearing cooling water quick filling line (Rate per mtr)
Charges for dismantling the 80 NB vertical distribution pipes without disturbing adjacent pipes and louvers cutting and removing the worn out punctured 80 NB MS tapping spool pipes from 400 NB header pipe in Cooling Tower including charges for T&P and Consumable
Charges for cutting the 80 NB MS Spool pipe to the required length, welding 80 NB MS flange with one end and other end welding with 400 NB header pipe. Refixing the 80 NB vertical distribution pipe on the cooling tower including charges for T&P Consumable
charges for hire charges for hydromac crane for leading and lifting of 400 NB distribution header line near cooling tower I area.
Material on Contractor Supply of MS Flange 80 mm
Material on Contractor Scope Supply of MS channel 100 x 50 x 5 mm thick
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_792089.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid