| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC NO 22 2 ND STREET ARVIND NAGAR MADAMPAKKAM CHENNAI TAMIL NADU 600126 | CHENGALPATTU | TAMIL NADU | 600126 | L1 | Accepted-AOC L1 for Item No 7 | |
| 2 | L1₹7.7 LAccepted-AOC 503 VEERABOYAR COLONY DR NANJAPPA ROAD COIMBATORE 641 018 | COIMBATORE | TAMIL NADU | 641018 | L1 | Accepted-AOC L1 for item No.2, 4, 5, 6 and item No.3 rejected | |
| 3 | L1₹66.0 LAccepted-AOC 32 FIRST FLOOR SAPTHAGIRI NAGAR PUZHUDIVAKKAM KANCHIPURAM TAMIL NADU 600091 | CHENNAI | TAMIL NADU | 600091 | L1 | Accepted-AOC L1 for item No 1 | |
| 4 | H₹69.5 LRejected-Finance D 55 A FIRST FLOOR NORT EAST EXTN THILLAI NAGAR 6 CROSS TIRUCHIRAPALLI 620018 | TIRUCHIRAPALLI | TIRUCHIRAPPALLI | TAMIL NADU | 620018 | H | Rejected-Finance Rejected | |
| 5 | Not Admitted-Fee/PreQual/Technical 10 14 E K GURU STREET NEAR VEPERY HIGH ROAD SBI BANK PERIAMET CHENNAI 3 | CHENNAI | TAMIL NADU | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
8 Jun 2023, 3:00 pmClosed
CE, JJM, Chennai
No.31, Kamarajar Salai, Chepauk 05.
Procurement of instruments for 31 Dt labs NABL reg for sub Dt Labs .
2023_TWAD_319854_1
IFB.001/F.Instr/CWA/TWAD/2023
Open Tender
Laboratory and scientific equipment
Item Wise
20 days
CE, JJM
As per bid document
3 documents required · 3 mandatory
₹0
₹82,000
Yes
CE, JJM, Chennai
22 Aug 2023
29 May 2023
9 Jun 2023
29 May 2023
8 Jun 2023
29 May 2023
1 Jun 2023
Lab Instruments:
Analytical Semi Micro Balance-Conformity to IS 9281, Part - III, 1981 specification with latest amendments there on. Analytical balance, 4 decimal sensitivity, integral draft shield, compact body of high durability with a spacious weighing chamber and quality exterior case. Accuracy supported internal calibration. Easy setting best fit to weighing application expanded piece counting function, Specific gravity mode, Formulation mode, Stability maintenance by full digital control i.e Digital, LCD, LED Display, Conformation to International Standards, Stainless Steel Pan 90 mm, Capacity - 220g, Accuracy-0.1 mg, Weighing Mechanism- Uniblock, Monoblock, Doors open wide in 3 directions, Level gauge provision at easiest visual position, Optional battery operation, NABL calibration certificate as per ISO 17025, 2017 with latest amendments there on, Power supply AC 220V, 50-60 Hz, Warranty min - 1 year.
Thermocouple Thermometer Digital with RTD or K type probe with cable(Digital)-IS 7358 , 1984 specification with latest amendments there on, Highly accurate thermometer precise measurements, Capacity Max. 600°C, 3½’’ digit liquid crystal display LCD or LED with a maximum reading of 1999, Operating Environment - 0°C to 50°C i.e.32°F to 122°F, less than 80% Relative Humidity, Storage Environment - minus 20°C to 60°C i.e. -4°F to 140°F, less than 80% R.H. with battery operated meter, Accuracy 1°C- Stated accuracy at 23°C ±5°C, less than 75% R.H. Battery - 1.5V x 4pcs AAA size, Dimensions- L241.3 mmX W157.98 mm XH76.2mm i.e. 9.5 X 6.22 X3 in, RTD or K type thermocouple OD-6mm, Length – 3 meter cable ,plug and socket. NABL calibration certificate. Warranty 1 year.
Microcontroller based Electrical Conductivity meter -Digital 4 ½ inch LED or LCD display, bench model, different measuring ranges 0-20, 0-200, 0-2000, 0-20000, 0-200000 micro mho per cm, with automatic temperature compensation arrangement, Resolution-0.01micro S, accuracy ± 1% mid scale, conductivity cell of 0.1 cell constant, with holder and clamp, TDS range-0-200ppt, AC operated. calibration up to 3 points. warranty min 1 year.
Microcontroller based pH meter -Digital, 4 ½’’ LED or LCD display, bench model, range 0-14 pH, accuracy - sensitivity 0.01 pH, with automatic temperature compensation with combined glass electrode, electrode holder, 3 point calibration for pH, MV-0 to 1999 MV, Slope-90% to 110%, 220V AC operated. warranty min 1 year.
Turbidity meter -Digital, Range 0-2000 NTU, Resolution 0.01 NTU for 0 - 100 NTU, 0.1 NTU for 100 - 1000 NTU, 1 NTU for 1000-2000, Repeatability ± 3%, Source-Projector lamp, Detector- Photodiode., calibration up to 3 points, including sample vials. Warranty min. -1 year.
Flame Photometer -Digital, dual channel - simultaneous display for both Na & K, capable of measuring 4 elements with single aspiration i.e. Na, K, Li and Ca with filters for Na, K, Li and Ca, 3 digit, Full scale sensitivity – Na-2 ppm, K-1 ppm, Li-1 ppm and Ca-30 ppm, operated on LPG supply, with compressor. warranty min 1 year.
THE I.L.E.CO.
THE PRECISION SCIENTIFIC CO CBE
Microtek Technologies
THE PRECISION SCIENTIFIC CO CBE
Shriram Enterprises Pvt. Ltd.,
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .