Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹35.7 L+₹95,682.90 (2.75%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹35.8 L+₹1.0 L (2.93%)Rejected-Finance KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹35.8 L+₹1.1 L (3.04%)Rejected-Finance F A ROAD MACHKHOWA PO PS BHARALUMUKH DIST KAMRUP M ASSAM GUWAHATI 781009 | KAMRUP METRO | ASSAM | 781009 | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹36.6 L+₹1.8 L (5.10%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹35.6 L
EMD Value
₹71,200
Closing Date
13 Feb 2023, 6:00 pmClosed
GE 872 EWS
GE 872 EWS, C/O 99 APO
SPECIAL REPAIRS TO ROOFING CEILING CERTAIN MISC ITEMS IN BLDG NO T-96 OF IFSU SPECIAL REPAIRS TO BLDG NO T-20 OF INF BDE CAMP PROVN OF VEH PARKING SHED FOR VEHS PARKING NEAR BLDG NO T-460 OF IFSU AND PROVN OF CERTAIN MINOR WORKS AT ALONG MIL
2023_MES_575130_1
8476/T-76/E8
Open Tender
Miscellaneous Works
Works
183 days
ALONG
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹71,200
Yes
31 Mar 2023
16 Jan 2023
14 Feb 2023
16 Jan 2023
13 Feb 2023
1 Feb 2023
16 Jan 2023 - 21 Jan 2023
Amount
B/R SERVICES/WORKS
Demolition Cement Concrete (Un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and Removing Debris, etc. to a Distance exc. 50.00 Metre and not exc. 100.00 Metre, complete all as specified and as directed.
Demolition Brick Work or Pre-cast Concrete Block Masonry, built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc., complete all as specified and as directed.
Dismantling Timber Scantlings 40 Sq Cm and Over in Section in Unframed Work, complete all as specified and as directed.
Dismantling Timber Fillets, Rails, Posts, Rafters, Purlins, etc. Under 40 Sq Cm in Section in Unframed Work, complete all as specified and as directed.
Taking down Chowkat or Frame of any description (without Taking Off Shutter from the Frame) not exc. 1.50 Square Metre Each, complete all as specified and as directed.
Taking down Chowkat or Frame of any description (without Taking Off Shutter from the Frame) of any description, exc. 1.50 Square Metre but not exc. 4.00 Square Metre Each, complete all as specified and as directed.
Taking down/out Unserviceable Rusted/ Worn out Wire Cloth/Netting of any description, fixed with Beads, etc., complete all as specified and as directed.
Dismantling Wrought Iron or Mild Steel Work of any description not otherwise provided for, complete all as specified and as directed.
Dismantling Structural Steel Work of any description and from any Situations, complete all as specified and as as directed.
Dismantling Plain or Corrugated Steel Sheeting of any gauge and thickness, Segregating the Serviceable Plain or Corrugated Steel Sheeting and Stacking properly at Sites and Keep in Safe Custody for re-use, complete all as specified and as directed.
Dismantling Ceiling Frame (Snap Grid) with Hangers (but except Boards) of any descriptions, complete all as specified and as directed.
Dismantling Wall and Ceiling Boards (Fibre, Pulp, Insulation, etc.) or Insulation Boards/ Slabs/ Blankets of any descriptions including Cover Fillets, complete all as specified and as directed.
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and Removing Debris, etc. to a Distance exc. 50.00 Metre and not exc. 100.00 Metre, complete all as specified and as directed.
Taking down Cement Plaster including Raking out Joints, Hacking for Key, Scrubbing down with Water and Removing Debris, etc. to a Distance exc. 50.00 Metre and not exc. 100.00 Metre, complete all as specified and as directed.
Surface Excavation not exc. 30 Cm Deep and ave. 15 Cm Deep and getting out in Soft/ Loose soil, complete all as specified and as directed.
Excavation in Trenches not exc. 1.50 Metre Wide and not exc. 1.50 Metre in Depth for Foundation etc. or for Shafts, Wells, Cess Pits, Manholes, Pier Holes, etc. not exc. 10.00 Sqm on Plan and not exc. 1.50 Metre in Depth and getting out as in Soft/ Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering and Well Ramming in layers not exc. 25 Cm, in Soft/Loose Soil, complete all as specified and as directed.
Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
Excavating in Post Holes (or Similar Holes) in Soft/Loose Soil, Each not exc. 0.50 CUM, getting out and Removing Surplus Soil to a distance not exc. 50.00 Metre and Making Good Surfaces, complete all as specified and as directed.
M&L Sand Gravel (as approved) Filling under Floors, Foundations, etc. including Spreading and Levelling, etc., complete all as specified and as directed.
M&L Hardcore Broken Stone or Boulders, gauge not exc. 63mm, deposited, Spread and Levelled in layers not exc. 15 Cm thick, Watered and Well Rammed to a True Surface, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregates) in Lintels upto 1.50 Metre Clear Span, Cills, Steps; Seismic and Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets and Railings upto 600mm in Height, Copings, Kneelers, Apex Stones, Bed Plates, Water Troughs and the Like including Weathering, Slightly Rounded or Chamfered Angles and Throating, Finishing all Exposed Faces of Concrete including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed. NOTE : Cost of Formwork will deemed to be included in the Quoted Unit Rate.
M&L Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregates) Columns, Pillars, Piers, Posts and Struts, etc., complete all as specified and as directed. NOTE : Cost of Formwork will deemed to be included in the Quoted Unit Rate.
M&L Cement Concrete 1:4:8 (40mm graded aggregates) in Foundations, Filling and Mass Concrete, etc. including necessary Formwork, complete all as specified and as directed. NOTE : Cost of Formwork will deemed to be included in the Quoted Unit Rate.
M&L Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregates) in Foundation including Raft, Footing, Foundation Beam for Column Basement Slab, under reamed Piles, complete all as specified and as directed. NOTE : Reinforcement & Formwork will be Measured and Paid for separately under appropriate Items.
M&L Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregates) Columns, Pillars, Piers, Posts and Struts, etc., complete all as specified and as directed. NOTE : Reinforcement & Formwork will be Measured and Paid for separately under appropriate Items.
M&L Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregates) in Slabs supported on Walls, Beams and Columns; in Floors, Roofs, Landings Balconies, Deck Slabs, Canopies and in Shelves and the like, complete all as specified and as directed. NOTE : Reinforcement & Formwork will be Measured and Paid for separately under appropriate Items.
M&L Formwork to Sides of Concrete Foundations, Footings, Bases of Columns, Raft and Raft Beams, Sides and Soffits (if any) of Foundation and Plinth Beams; and Similar Work; Vertical or to Batter, Flat, Rough Finished surfaces of Concrete, complete all as specified and as directed.
M&L Formwork to Sides Pillars, Posts, Struts, Piers, Columns and Stanchions and Similar Work; Rough Finished surfaces of Concrete, complete all as specified and as directed.
M&L Formwork to Soffits of Suspended Slabs such as Roof Slabs, Floor Slabs, Landings and Similar Works; not exc. 200mm thick (Horizontal or Sloping), etc., Rough Finished surfaces of Concrete, complete all as specified and as directed.
M&L Pre-cast Cement Concrete Block Masonry with Solid Blocks of Size 300x200x200mm or 300x200x100mm, having Compressive Strength of not less than 100 Kg/ Sq Cm (as per IS-2185) in Cement Concrete 1:3:6 (20mm graded stone aggregates), exc. 10 Cm in Width and Setting in Cement Mortar 1:6, complete all as specified and as directed.
M&L Cutting Holes in Brick/ Pre-cast Concrete Block Walling, not exc. Half Brick thick, built in Cement Mortar for inserting of Holdfasts, Lugs, etc. and Making Good to Dismantled portion with Cement Concrete 1:2:4 (20mm graded stone aggregates) or Cement Mortar 1:3 (as required) and Adjoining Surfaces in Cement Mortar 1:4, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Plain Fillets, Wrought, Square, Rectan-gular or Triangular in Section, secured with Nails, Cross Sectional Area exc. 6.00 Sq Cm but not exc. 13.00 Sq Cm, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Plain, Solid, Straight, Chowkats and Frame, Wrought, Framed rebated on the Solid, Rounded or Chamfered, put together with Glue pinned at Joints, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Panelled Shutter 35mm thick (any number Panels) Plain, Framed with Lock Rails, having Panels of 12mm thick BWP, Commercial Ply or 12mm thick Veneered Particle Board Medium density, Wood Particle Board with Commercial Face Veneers and fitted to Chowkat, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Panelled Shutter 30mm thick (any number Panels) Plain, Framed with Lock Rails, having Panels of 12mm thick BWP, Commercial Ply or 12mm thick Veneered Particle Board Medium density, Wood Particle Board with Commercial Face Veneers and fitted to Chowkat, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Glazed and Skeleton Shutter 30mm thick, Open Rebated and Prepared to receive Glass, Gauze, etc. (without Sash Bars), Edges of Framing plain, chamfered or rounded. fitted with cut and mitred Beads for securing glass, etc.; sizes of Members of Shutters as specified in SSR Part-I, Section 8, Clause 8.24(a) and fitted to Chowkat, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Glazed and Skeleton Shutter 30mm thick, Open rebated and prepared to receive Glass, Gauze, etc., Divided into Squares, with plain, chamfered or rounded, mitred and rebated Sash Bars (any numbers), fitted with cut and mitred beads for Glass, Gauze, etc., Sizes of Members of Shutters as specified in MES Schedule Part-I, Section 8, Clause No. 8.24(b) and fitted to Chowkats, complete all as specified and as directed.
M&L Anodised Aluminium Powder Coated (Thickness of Powder Coating not less than 50 micron) Frame for Doors, Windows, Ventilators with One or More Rebates including Joining Cleat for fixing, etc., complete all as specified and as directed.
M&L Anodised Aluminium Powder coated (Thickness of Powder Coating not less than 50 micron) Door Shutters, Aluminium Section weighing not less than 0.55 KG/RM including necessary Joining Cleats, Glazing Clips, Rubber/ Neoprene Packing, Handles (as approved) - 2 No. in Each Door, Stainless Steel Hinges of Size as ordered, Anodised Aluminium Snap Beading, Screws, etc, complete all as specified and as directed. NOTE : Cost of Aluminium Fittings/ Builders Hardware as metioned here-in-above will deemed to be included in the Quoted Unit Rate.
M&L Anodised Aluminium Powder coated (Thickness of Powder Coating not less than 50 micron) Window and Ventilator Shutters, Side Hung type, Without Sash Bars, Aluminium Sections weighing 0.55 KG/RM including necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Anodised Aluminium Fittings such as Peg Stay 150mm long (01 No.), Hinges Type B-21 100mm long (02 No.), suitable Handle (01 No.). in Each Shutter, etc, complete all as specified and as directed. NOTE : Cost of Aluminium Fittings/ Builders Hardware as metioned here-in-above will deemed to be included in the Quoted Unit Rate.
S&F Anodised Aluminium Powder coated (Thickness of Powder Coating not less than 50 micron) Door/ Window/ Ventilator Frame and Side/ Top Hung or Multi-Track Sliding Shutter complete and fixed with Fittings, One or More Rebates including Jointing Cleat, Glazing Clips, Rubber Neoprene Packing, Aluminium Snap Beading, Screws, Anodised Aluminium Fittings, Rollers, Locking System, etc. complete all as specified and as directed. NOTE :- (a) Sheet Glass, Particle Board, Hinges, Handle, Floor Spring, Hydraulic Door Closer will be Measured and Paid separatly under approprate Items. (b) Aluminium Frame with Shutters shall be fixed in Position in the Wall Opening as required according to Site Conditions including all Fastening Arrangemennts, etc (c) The Gap shall be Sealed Externally with Polysulphide Sealant and Finished Flush with the Surface.
S&F Solid PVC Door Frame of size 50x47mm made out of 5.0mm thick plain colour PVC Sheet reinforced with Mild Steel Square Tube and fixing in Opening as per Specification and Drawing of MES Schedule, complete all as specified and as directed.
S&F Factory Made Solid Panel PVC Door Shutter 30mm thick (Style) consisting of Frame made out of Mild Steel Tubes for Top & Bottom Rails, Mild Steel Frame shall be covered with Heat Moulded Plain Color PVC ‘C’ Channel having a PVC Strip of 20mm width stuck inside with Solvent Cement for Stiles & Plain Color PVC Sheets for Top Rail, Lock Rail & Bottom Rail on Either Side & Gap insert for Top Rail & Bottom Rail, Paneling of Plain Color PVC sheet to be fitted in the Mild Steel Frame, welded/sealed to the Stiles & Rails with suitable PVC Sheet Beading & jointed together with Solvent Cement and fixing in the Frame with Butt Hinges as per Site as per Specification and Drawing of MES Schedule, complete all as specified and as directed. NOTE : Butt Hinges will be Measured and Paid under appropriate Item(s).
S&F Aluminium Anodised Barrel Tower Bolt of Size 125mm long, Extruded Section, complete all as specified and as directed.
S&F Aluminium Anodised Barrel Tower Bolt of Size 150mm long, Extruded Section, complete all as specified and as directed.
S&F Mild Steel Sliding Door Bolt 300mm long, Plate type, Stove Enamelled Black, with Bright Bolt not less than 12mm dia with and including a minimum of 6 Bolts and Nuts, Four on Bolt Plate and Two on Staple Plate, complete all as specified and as directed.
S&F Aluminium Alloy, Anodised, Sliding Door Bolt 300mm long with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminium Alloy, complete all as specified and as directed.
S&F Stainless Steel Butt Hinge 75mm in size, complete all as specified and as directed.
S&F Mild Steel Butt Hinge 100mm in Size, Medium Weight, Cold Rolled, complete all as specified and as directed.
S&F Stainless Steel Butt Hinge 100mm in size, complete all as specified and as directed.
S&F Aluminium Handle 125mm, Cast type, Anodised, complete all as specified and as directed.
S&F Aluminium Handle 150mm, Cast type, Anodised, complete all as specified and as directed.
S&F Mild Steel Ordinary Rat Tail Rod Pattern Spring 300mm for Door Shutter including Roller and Roller Plate, fixing to Chowkats with Welding or Screws as per Site requirement and Fixed-in-repairs, complete all as specified and as directed.
S&F Brass Mortice Lock of Size 100mm, 2 Levers, Vertical type, complete all as specified and as directed.
S&F Floor Door Stopper of Aluminium Alloy Body and Tongue, Anodised, with Hard Drawn Steel Spring, Overall length of Cover Plate 150mm, fixing in Floor, complete all as specified and as directed.
S&F Door Closer, Hydraulically Regulated, Aluminium (Extruded Section) Body, Designation No. 3, Universal type, suitable for Door Shutters of 851mm to 1000mm in Width and of Weight between 61.00 KG to 80.00 KG, complete all as specified and as directed.
S&F Nylone Fly-Proof Net (as approved) in Aluminium Frame Work of Windows, etc., complete all as specified and as directed.
S&F Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average Width of Aperture 1.40mm and fixed with Stainless Steel Wire Staples, complete all as specified and as directed.
S&F Sheet Glass 3.0mm thick, Plain, Ordinary quality and Glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane, complete all as specified and as directed.
S&F Sheet Glass 5.5mm thick, Plain, Ordinary quality and Glazing in Aluminium Frame Work with necessary Jointing Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, complete all as specified and as directed. NOTE : Jointing Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, etc. will be Measured and Paid separatly under BOQ Item No. 1.040 to 1.042 here-in-before.
S&F Solar Control Film 25 Micron Reflective Type Sticked to Glass Panes of any Size and thickness as per Instructions of Manufacturers, complete all as specified and as directed.
M&L TMT Bars 10mm dia and Over, Cut to length, Bent to Shape required including Cranking, Bending Spirally for Hooping for Columns, hooking Ends and Binding with and including Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed.
M&L TMT Bars 8.0mm dia, Cut to length, Bent to Shape required including Cranking, Bending Spirally for Hooping for Columns, hooking Ends and Binding with and including Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed.
M&L TMT Bars 8.0mm dia in Stirrups, Spacers and Binders, Cut to length, Bent to Shape required including Cranking, Bending Spirally for Hooping for Columns, hooking Ends and Binding with and including Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed.
M&L Mild Steel Bands, Straps, Supports or Stays for Rain Water, Ventilating Pipes including Bolts (if required), Heavy Hooks (Stay) for Large Gates; Hook and Pintle Hinges, Large Hasps and Staples; Chains; Hand Made Sliding Bolts; Clamps; Holdfasts (Flat Iron 25x4.0mm); Wall Ties; Hooks for Hanging Fans; Plain Angle Cleats for securing Purlins to Wood Trusses or Rafters; Knee Piece inserts; 2-way and 3-way Straps, Plate Washers and Similar Small Articles, conform to Fe-290 Gde-E-165, complete all as specified and as directed.
M&L Mild Steel Chimney Bars (straight or camber); Bearing Bars; Tongues or Water Bars for Window Frames; Window Guard Bars, plain, let in and fixed Independently in Wooden Frames, L or T Section Supports for Shelves, etc. and Similar Articles conforming to Fe-290 Gde-E-165, complete all as specified and as as directed.
M&L Mild Steel Framed Works such as Grills, Gratings, etc. with Ends of Bars shouldered and/or riveted or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walkways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as specified and as directed.
M&L Rolled Mild Steel Framed Work in Doors or Gates of Angle or Other Section with Gusset Plates, Rails, Braces, etc., complete, drilled for fixing of Steel Sheeting or Other Covering. Doors, etc. to be prepared for Hanging or Sliding with and including either Hooks and Hinges or Steel Hanging Door Fittings (Exclusive of Steel Sheeting or Other Covering, Running Rails and Guides) and Hanging; also Fastening and Fixing, conforming to Fe-290 (Gde E-165), complete all as specified and as directed.
M&L Rolled Mild Steel Sections in Joist, Channel, Angle, or Tee Sections in Vertical Post, fixed independently, without Connecting Plates, etc. (cut to ordinary Lengths i.e. within 20mm of the Length indicated), conforming to Fe-410-W (Gde E-250) Quality 'B', complete all as specified and as directed.
Re-fixing only Rolled Mild Steel Sections in Joist, Channel, Angle, or Tee Sections (Serviceable Steel Sections obtained from BOQ Item No. 1.010 here-in-before) in Vertical Post, fixed independently, without Connecting Plates, etc. (cut to ordinary Lengths i.e. within 20mm of the Length indicated), complete all as specified and as directed.
M&L Rolled Mild Steel Sections in Main and Cross Beams, Hip & Jack Rafters, Purlins where connected to Common Rafters, Running Rails and Guides for Sliding Doors, conforming to Fe-410-W (Gde E-250), Quality 'A', fixed with Angle Cleats or Other Connecting Plates, complete all as specified and as directed.
M&L Mild Steel Tubular Trusses including Special Shaped Washers, etc. complete using ERW or Induction Butt welded Tubes, confirming to IS:1161-1979, Grade St-240, complete all as specified and as directed.
M&L Plate Girder or Single Stanchions, built up of One Beam or Channel Section with Flange Plates, Caps, Bases, Splices, Angle Brackets, Cleats and Other Connections, conforming to Gde Fe-410-W (Gde E-250) Quality 'A', complete all as specified and as directed.
S&F Corrugated Mild Steel Sheeting 0.63mm thick, Galvanised @ 120 Gram Per Sqm with Two Corrugation Side Lap, fixing with and including L-type or J-type Cranked Hook Bolts with Washer, etc., complete all as specified and as directed.
Re-fixing only Corrugated Mild Steel Sheeting (except Sheets, Serviceable Sheet obtained from BOQ Item No. 1.011 here-in-before) with Two Corrugation Side Lap, fixing with and including providing L-type or J-type Cranked Hook Bolts with Washer, etc., complete all as specified and as directed.
S&F Plain Mild Steel Sheeting 0.80mm thick, Galvanised @ 120 Gram Per Sqm in Ridges, Hips, Valley Gutters, etc., fixing with and including L-type or J-type Cranked Hook Bolts with Washer, etc., complete all as specified and as directed.
Re-fixing only Plain Mild Steel Sheeting (except Sheets, Serviceable Sheet obtained from BOQ Item No. 1.011 here-in-before) with Two Corrugation Side Lap, fixing with and including L-type or J-type Cranked Hook Bolts with Washer, etc., complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Corrugated Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Plain Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Ridges/ Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
M&L Exposed Suspended False Ceiling System with Powder Coated Anodised Aluminium Sections Snap Grid/ Frame Work of Size 605x605mm, all as per Specifica-tion and Drawing of MES Schedule (except Hangers), complete all as specified and as directed.
S&F GI Frame Work for Seamless Ceiling, Size of Grid 605x605mm, comprising of GI Perimeter Channel 0.55mm thick with 2 Unequal Flanges of 20mm & 30mm and Web of 27mm fixed to surrounding Wall using Nylon Sleeves and Screws at 450mm Centre to Centre/ Intermediate Channel 0.9mm thick having Equal Flanges of 15mm Each and Web of 45mm Suspended from Soffit at approx 900mm Centre to Centre with GI Cleat and Steel Expansion Fasteners with and including Ceiling Section (not exc 1.20 Metre Length) of 0.55mm thickness having Kurled Web of 50mm and Flange of 26mm Each with Lips of 10.5mm fixed to the Intermediate Channel at 457mm Centre to Centre, complete all as specified and as directed.
S&F Hangers 4.0mm dia GI (upto 1200mm length) for adjusting Level, fixed to Roof Slabs by means of Ceilling Cleats made out of GI Flat 40x3.0mm in Size, 60mm long and Expansion Hold Fasteners 12.5mm dia, 40mm long, complete all as specified and as directed.
S&F HSPC Non-Asbestos Fibre Cement Building Board 595x595x6.0mm thick, Pre-primed, Self Embossed, Textured Designer Boards, Water Resistant, Termite Resistant, Fire Resistant for insulation, fixed or laid/ inserted to Snap Grid Frame Work with Screws, complete all as specified and as directed.
S&F Plywood 6.0mm thick, BWR Grade, Type BB, fixed with Screws to Timber Frame Work, complete all as specified and as directed.
S&F Particle Board 9.0mm thick, Medium density, Flat Pressed, Single Layer Yype or Three Layer Type, BWR Type Adhesive, fixed with Screws to Aluminum Frame Work, complete all as specified and as directed. NOTE : Jointing Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, etc. will be Measured and Paid separatly under BOQ Item No. 1.040 to 1.042 here-in-before.
M&L Non-skid Ceramic Coloured Tiles, Joint Free (1st quality and as approved) 7.0-8.0mm thick (Square/ Rectangular), Area of Each Tile exc. 0.18 Sqm but not exc. 0.38 Sqm in Floors, Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Cement Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed will deemed to be included in Quoted Unit Rate.
M&L Non-skid Ceramic Coloured Tiles, Joint Free (1st quality and as approved) 7.0-8.0mm thick (Square/ Rectangular), Area of Each Tile exc. 0.18 Sqm but not exc. 0.38 Sqm in Vertical Surfaces i.e. Dado, Skirting, etc., set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile fixing over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed NOTE : Cost of Cement Screed Bed will deemed to be included in Quoted Unit Rate.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregates) 75mm thick in Plinth Protection, etc., Laid in Alternate Panels, finished Concrete Surfaces Even and Smoooth without Using Extra Cement, complete all as specified and as directed.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) 75mm thick in Sub-base to Floor, etc., complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick in Hardstanding, etc., Laid in Alternate Panels, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L Rendering 10mm thick in Cement Mortar 1:6 on Brick/ PCC Blocks or Concrete Works, finished Plastered Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L Rendering 15mm thick on Bricks/Pre-cast Blocks or Concrete Works consisting in 2 layers, Backing/Under layer of 10mm thick in Cement Mortar 1:4 and Float/Top layer 5.0mm thick in Cement Mortar 1:4 including mixing WPC to Float/Top layer, finished Fair and Even, complete all as specified and as directed. NOTE : Integral Water Proofing Compound (WPC) will be Measured and Paid separately under appropriate Item.
Supply only Water Proofing Compound (as approved), conforming to IS:2645-2003, complete all as specified and as directed.
M&L Preparing Newly Plastered Surfaces of Walls and applying Three Coats of White Wash, complete all as specified and as directed.
M&L Preparing New Plastered Surfaces of Walls and applying Wall Care Putty 1.5mm thick on Plastered Surfaces of Walls including Cutting and Rubbing down to obtain an Even and Smooth Surface, complete all as specified and as directed.
M&L Applying Two Coats of Distemper Oil Emulsion (as approved) over a Coat of Chalk Whitening (Priming Coat) on Putty Finished Surfaces, complete all as specified and as directed.
M&L Preparing Old Distempered and Painted Surfaces of Walls by Washing, Rubbing down and Stopping of Surfaces and Applying One Coat of Distemper Oil Emulsion (of approved Tint), complete all as specified and as directed.
M&L Preparing Newly Plastered Surfaces of Walls and applying Two Coats of Cement Based Paint (of approved Tint) Over a Coat of Alkali Resistant Priming Paint, complete all as specified and as directed.
M&L Preparing New Wooden Surfaces of any description, over 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of as approved Tint) over a Coat of Pink Primer, complete all as specified and as directed.
M&L Preparing Old Wooden Surfaces of any description, over 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint), complete all as specified and as directed.
M&L Preparing New Wooden Surfaces of any description, not exc. 10 Cm in Width or Girth when unconnected with Other Painting or when Painted in Different Tint and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint) over a Coat of Pink Primer, complete all as specified and as directed.
M&L Preparing Steel and Iron Surfaces of any descriptions, over 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M&L Preparing Old Painted Steel and Iron Surfaces of any description, over 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint), complete all as specified and as directed.
M&L Preparing Previously Untreated Surfaces of Wood and Wood Based Materials, of any description and girth not otherwise described and Treating with Tar or Coal Tar Black Paint to Backs of Chowkats, etc. Area tarred exc. 0.10 Sqm but not exc. 0.50 Sqm Each including Sanding with Clean Sharp Sand after tarred, complete all as specified and as directed.
M&L Preparing Previously Untreated Surfaces of any description and girth not otherwise described and Treating with Tar or Coal Tar Black Paint to Holdfast or similar Small Items, Area tarred not exc. 0.10 Sqm Each including Sanding with Clean Sharp Sand after tarred, complete all as specified and as directed.
E/M SERVICES/WORKS
M&L Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) complete from in any Position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets but excluding Light Fittings of any descri-ption, Making Good Disturbed Surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 including providing Surface Treatment (White/Colour Washing, Distempering, Painting, etc.) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded single core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable Size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable Size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/ FAN/ BELL POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Wire for ONE 3/5 PIN SOCKET OUTLET 6 AMP POINT on SAME BOARD, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable Size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable Size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SWITCH SOCKET COMBINATION 6 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable Size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable Size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SWITCH SOCKET COMBINATION 6/16 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed.
S&F PVC Casing Capping (ISI Marked) of Size 25mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc., including Taking down/ out Unserviceable PVC Casing Cappin, complete all as specified and as directed.
S&F Rigid Non-metallic PVC Conduit of Size 20mm (External Dia) Exclusive of Boxes (Junction/ Terminal) but inclusive of all Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends and Fixing Accessories such as Couplers, Lock Nuts, Saddles, Pipe Hooks, etc., complete all as specified and as directed.
S&F Rigid Non-metallic PVC Conduit of Size 20mm (External Dia) Exclusive of Boxes (Junction/ Terminal) but inclusive of all Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends and Fixing Accessories such as Couplers, Lock Nuts, Saddles, Pipe Hooks, etc. including Taking down/ out Unserviceable PVC Conduit Pipe, complete all as specified and as directed.
S&F PVC Rectangular Board of Size 350x300x50mm deep, Closed Recessed with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out Unserviceable PVC Board, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Single Pole, Flush type, 1-way, 230 Volt AC and Connecting up, complete all as specified and as directed.
S&F Socket Outlet 6 Amp, 5 Pin, Flush type, 230 Volt AC and Connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 6 Amp, 3 Pin, 2-in-1, Flush type, 230 Volt AC and Connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 6/16 Amp (3 Pin & 3 Pin), Multi-purpose type, 2-in-1, 230 Volt AC and Connecting up, complete all as specified and as directed.
S&F Lamp/Angle Holder PVC/ Polycarbonate type with Back Plate suitable for Batten Fitting and Connecting up, complete all as specified and as directed.
S&F Ceiling Rose 65x50mm, 3 Terminals, Surface Bakelite suitable for 230 Volt AC and Connecting up, complete all as specified and as directed.
S&F Decorative LED Light Fitting 1x10 Watt Bulkhead Luminaires including LED Light, Driver, Holder and Connecting up with suitable Length and Size 3 Core Twisted Flexible Copper Conductor Cable including Taking down/ out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Tube Light Fitting 1x20 Watt, T-08 complete with 20 Watt T-8 LED Batten/ Rod and mounted on 2 No. PVC Box suitable for fixing of Tube Light Fitting and Connecting up with suitable Length and Size 3 Core Twisted Flexible Copper Conductor Cable including Taking down/ out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Luminaire 600x600mm 35/36 Watt, (3000K to 6000K), 220 Volt AC, Recessed type with High Efficiency PMMA Diffuser Soft Glare Free Light complete with Driver, Holders and LED Lamp suitable for Roof Ceiling and Connecting up with suitable Length and Size 3 Core Twisted Flexible Copper Conductor Cable including Taking down/ out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Light Fitting 45 Watt, 5700K, of PANEL Size 2'x2', Enviromentaly Friendly, New Generation, Ultra Modern Recess mounting/ Grid Celing mounted with Electronic Driver with High Brightness SMD LEDs as Light Source, complete with all Accessories, Pre-wired and Connecting up with suitable Size 2/3 Core Twisted Flexible Copper Conductor Cable including Taking down/ out Unserviceable Light Fitting of any description, complete all as specified and as directed.
Taking down Ceiling Fan/ Exhaust Fan of any Make/Model/Sweep from any Height after disConnecting Electric Connection and Keep in Safe Custody for Re-hanging/ Re-fixing and Repairing, complete all as specified and as directed.
M&L Opening Body of Ceiling Fan 1200mm Sweep in presence of JE-in-Charge, Checking for Repair Works involving, Transporting Ceiling Fan from AGE E/M Store Yard at ALONG to nearest Workshop, Taking out carefully burnt out Winding of any type from the Fan of any Make, Cleaning of Slots, Rewinding Fan Motor with Super Enamalled Copper Wiinding Wire of suitable Gauge and Weight (not less than 350 Gram) providing New Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Preparing Old Painted Surfaces of Ceiling Fan/ Exhaust Fan including Cleaning, Washing, Rubbing and Filling Cavities with Filler, applying One Coat of Synthetic Enamelled Paint (as approved) with Spray Painting Machine and Writing MES No. with Black Paint, complete all as specified and as directed.
M&L Hanging only Ceiling Fan or Fixing only Exhaust Fan (Ceiling Fan/ Exhaust Fan obtained from BOQ Item No. 2.020 here-in-before after repaired) and Connecting up with and including suitable Size Copper Conductor Cable from Ceiling Rose to Connector of the Fan, complete all as specified and as directed.
S&F MCB Single Pole 6 Amp to 32 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and Connecting up including Taking down/out Unserviceable MCB of any description, complete all as specified and as directed.
S&F MCB Single Pole & Neutral 10 Amp to 32 Amp, 'B' Series, 50 Hz, 10 kA, 240 Volt and Connecting up including Taking down/out Unserviceable MCB of any description, complete all as specified and as directed.
S&F MCB 40 Amp Double Pole, 'C' Series, 50 Hz, 10 kA, 240 Volt and Connecting up, complete all as specified and as directed.
S&F RCBOs 32 Amp, 30 mA, Double Pole for Earth Leakage, Overload & Short Circuit Protection and Connecting up including Taking down/out Unserviceable RCBOs of any description, complete all as specified and as directed.
S&F Sheet Metal Enclosure for DB's when MCBs to be used SPN 2-way, 240 Volt AC, Single Door, IP-43 Protected, Epoxy Based Powder coated, without Bus-bars and Connecting up, complete all as specified and as directed.
S&F Sheet Metal Enclosure for DB's when MCBs to be used SPN 8-way, 240 Volt AC, Double Doors, IP-43 Protected, Epoxy Based Powder coated suitable for mounting MCB DP/ SPN as Incomer and MCB SP as Out-goings with 200 Amps rated Bus-bar, Neutral Bar, Earth Bar, Connecting Cable Links and Connecting up including Taking down Unserviceable Sheet Metal Enclosure of any description, complete all as specified and as directed.
Supply, Installation & Commissioning of Water Cooler, Fully Stainless Steel Body, Electric Driven, Single Phase, BEE 5 Star rated and as approved, having approx Storage and Nominal Cooling Capacity 150/150 LITRE, complete all as specified and as directed.
S&F PVC Drain Pipe 20mm bore (dia) for draining out Water from Watter Cooler, including Providing necessary Connections, complete all as specified and as directed.
Supply & Installation Voltage Stabilizer 5.0 KVA Capacity, suitable for Automatic Operation, Single Phase, Naturally Air Cooled, Indoor type and Designed for Input Variation between 170 Volt to 250 Volt with Output Voltage stabilized at 230 Volt with accuracy of +2.5% and Testing, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of Size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing including Taking down/out Old Unserviceable Earthing of any description, complete all as specified and as directed.
Disconnecting & Taking down/out Unserviceable LT Cable of any Size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable (if any) Cables, Bricks/Cable Protection Cover, etc., complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Water Pipe Line, Electric Cable Line, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Water Pipe Line, Electric Cable Line, etc. with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Supplying, Laying & Testing LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed, Heavy duty, Armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998 having Cross-sectional Area 10 Sqmm, 2 Core, laid in Trenches, Ducts or through Pipes, etc., complete all as specified and as directed. NOTE : Earth Works, Protection Pipes/ Bricks or Pre-cast Concrete Cable Covers, etc. will be Measured and Paid separately under relevent Items.
M&L HDPE Double Wall Corrugated (DWC) High density Polythene Pipes of Outer dia 40mm and Inner dia 32mm, cut to length/Size as per Site requirement having Corru-gation on the Outer Wall and Plain Surface on the Inner Wall, confirming to IS:14930 (Part I & II) for Protection of Under Ground Cable/ in PCC with and including all Fittings as required at Site including Cutting Floor and Making Good the same to match the Existing/ Adjoining Surfaces, etc., complete all as specified and as directed. MAKE : REX POLY EXTRUSIONS (ELDREX) or equivalent (ISI marked). NOTE : The Cost of All Accessories for fixing of DWC Pipe along the Wall/ Roof/ Cable Trays will deemed to be included in the Quoted Unit Rate.
ANZ CORPORATION
M/S CHANDAN ENTERPRISE
M/S RAJA CONSTRUCTION
MOINUL HOQUE CHOUDHURY
B S ENTERPRISE
M/S JUBARAJ GOGOI
M/S Raju prasad
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .