| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-Finance | ₹18.3 L | L1 | Accepted-Finance Responsive |
| 2 | L2₹20.6 LAccepted-Finance | ₹20.6 L | L2 | Accepted-Finance Responsive |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
| Sl No | Description | Qty | Unit | Health Imaging Pharmaceuticals L2 | TITANIC ENGINEERING SERVICES L1 |
|---|---|---|---|---|---|
| 1.00 | 15 KW High Frequency Fixed X-Ray Machine (300 mA) | 1 | complete job | 20,55,200 ₹20.6 L | 18,25,550 ₹18.3 L |
| 1.01High Frequency X-Ray Machine suitable for general radiography X-RAY GENERATOR: High Frequency X-Ray generator having frequency of 100 KHz or more should be provided. Power output of generator should be not more than 15 KW. Radiography KV range should be : 40 to 125 KV with 1 KV Step mA range (RAD): 50- 300 mA or more in 9 Stations or more mA Stations : 50,63,80,100,125,160 for small focus & 200 & 300 large focal mAs range ( RAD) 1 to 300 mAs in 30 Steps or more Exposure time (Rad.) 3.3 ms to 6 Sec. Machine must give 300 mA at 50 KV of 0.1 Sec. Generator should offer 3 Point technique & user should have mA, KV & mAS. parameters selection range. | |||||
| 1.02CONTROL : A very compact feather touch control panel having following function & Indications should be provided. The panel can be supplied in floor mount with spill proof design. Following feature should be available on the control panel: Machine on/Off Switch. 12 cm LCD Digital Display of KV, mA & mAs. KV, mA & mAs Increase and decrease Switches. Ready & X-Ray On switch. Bucky selection switch. Tube focal spot selection is automatic. Depending on applied mA. Collimator lamp on /off switch at control panel & collimator. Self-diagnostic Programme with indicators for :- Earth Fault Error, Filament Error, Inverter Error, Rotor Error ,Tube head Thermal overload. Anatomically Programming Radiography (i.e. APR) should be provided in which KV, mA & mAs are automatically selected depending upon the physically of the patient and part of the body to be X-Rayed. Anatomical programming of minimum 220 programmes should be provided. APR program for Baby, Small, Medium, Large & Extra Large patient. X-RAY TUBE : ( Make & Model of Tube should be mention) One no. Dual focus Rotating Anode X-Ray tube thermally protected. Small Focus is 1.0 mm & large focus is 2.0 mm Anode heat storage capacity of tube should be 150 KHU One pair of 6 meter H.V Cable. One no. Double slot Manual Collimator with auto shut off facility should be provided. | |||||
| 1.03HV TANK : A very compact H.V Tank filled with high dielectric transformer oil should be provided. The H.V Tank should contain H.V transformers Filament, Transformers, H.V rectifies & H.V cable receptacles. TUBE STAND : Floor to ceiling stand with counter balanced tube head (rotatable ± 90 °) 180° rotatable mounted on floor ceiling rails for convenient movement should be provided. TABLE : Manual Multi position Table should be provided. Table Height is 860 mm, Table width is 830 mm & length 1970 mm. Tilting angle '-15°, 0° , 30° , 60° & 90° The Table should consist of motorized reciprocating Bucky with imported grid of size 17¼” x 18¾” & of Ratio 8:1-85 Lines/inch. The Bucky should cover the entire length of the table and should be locked at any desired position by an Electromagnetic lock. The table should be made of low radiation absorption, waterproof material. Table Accessories like stainless steel cassettes tray should be provided. Bucky should accept cassettes up to 14”x 17” POWER REQUIREMENT : The unit should be operable on 3 Phase, 440 Volts AC, 50 Hz 15 Amps with line –resist less than 0.4 ohms. Line regulation ± 10%. | |||||
| 1.04APPROVALS: 1. The quoted model should be approved by AERB & BIS. 2. Company should have ISO 9001:2015, ISO 13485:2016, EN ISO 14971:2012 and ICMED 13485 certificate. Also have MD 9 License to Manufacture Medical Devices from CDSCO of quoted model. 3. Quoted X-Ray tube should be registered with quoted X-Ray machine model. 4. X-ray manufacturer is registered in MSME & NSIC. 5. Manufacturer didn’t have blacklisted /debar from any State Govt/ PSU/Central Govt institute in past Ten Years. No stay order and pending debar case is pending in Indian Penal Court. 6. Manufacturer is having 100 Nos. installation of X-Ray machines in Govt. sector in last One Year. 7. X-Ray manufacturer is having Testing & Calibration Lab with NABL approved and compliance with ISO/IEC 17025:2017 standard. | |||||
| 1.05Flat Panel Detector 1. The detector should be both wired and wireless for data communication. 2. The detector should be a flat panel detector with Cesium Iodide Scintillator 3. The size of the detector should be 35 cm x 43cm (14”x17”) or more 4. Should have spatial resolution of 3 lines pair / millimeter or better 5. Pixel Pitch should be 150 micron or less 6. Detector Quantum Efficiency (DQE) should be 70% or more @ Zero lines pairs (near zero) & MTF minimum 80% at 1 cyc 7. The active-matrix size should be 2.3K x2.3K or more 8. Should have a minimum grey scale of 16 bits/ pixel 9. Detectors should be supplied with two external batteries and the supplied charger should be able to charge two batteries at a time. Detector with inbuilt battery should not be quoted. 10. The detector should be able to work without the battery also under wired mode. 11. Detector should be light weight (< 3kg) 12. Detector should have software which corrects the effect of scatter radiation on acquired image by processing, without the need of physical grid. It should be quoted as optional. 13. Withstand Load: Point Load – 100 kg or more, Surface Load – 300 kg or more 14. Detector should be CE or USFDA approved | |||||
| 1.06Acquisition Workstation: 1. Should have a high resolution TFT/LCD monitor of minimum 17” size or more 2. The Console or Acquisition Workstation PC to be supplied should be of latest generation with at least 4GB RAM. 3. Operating console should have facility for patient identity entry, viewing and processing images. | |||||
| 1.07DRY IMAGER SYSTEM 1. The system must have a laser printer without need of any wet chemistry. 2. It must be DICOM compatible allowing multiple modalities to be connected at a time. 3. The system must be able to print at least 70 films/ hr. of the 14" X 17" size. 4. The imager must have spatial resolution of 500 dpi minimum. 5. The system must have contrast resolution of 12 bits/ pixel or more. 6. The imager should be equipped with 2 tray on line. 7. Time Required for Startup Approx. 15 minutes under 25 o C room temperature conditions. Approx. 10 minutes under 25o C room temperature conditions in Power Saving Mode | |||||
| 2.001. Note:- The rates quoted by the bidder/s shall be final and inclusive of taxes, carriages of all materials (Mechanical/Manual) and all extra charges till the Installation, Testing of equipment/s is complete in all respects. | |||||
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
27 Mar 2025, 6:00 pmClosed
DSW-SKUAST-K
Shalimar
Procurement of 15 KW High Frequency Fixed X-Ray Machine (300 mA) Under Development Grant at Medical Unit, Main Campus Shalimar, SKUAST-K.
2025_SKUST_274719_1
E-NIT02of2025
Open Tender
Laboratory and scientific equipment
3 days
main campus shalimar
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Assistant comptroller
₹20,000
16 Dec 2025
22 Mar 2025
28 Mar 2025
22 Mar 2025
27 Mar 2025
22 Mar 2025
Amount
15 KW High Frequency Fixed X-Ray Machine (300 mA)
HV TANK : A very compact H.V Tank filled with high dielectric transformer oil should be provided. The H.V Tank should contain H.V transformers Filament, Transformers, H.V rectifies & H.V cable receptacles. TUBE STAND : Floor to ceiling stand with counter balanced tube head (rotatable ± 90 °) 180° rotatable mounted on floor ceiling rails for convenient movement should be provided. TABLE : Manual Multi position Table should be provided. Table Height is 860 mm, Table width is 830 mm & length 1970 mm. Tilting angle '-15°, 0° , 30° , 60° & 90° The Table should consist of motorized reciprocating Bucky with imported grid of size 17¼” x 18¾” & of Ratio 8:1-85 Lines/inch. The Bucky should cover the entire length of the table and should be locked at any desired position by an Electromagnetic lock. The table should be made of low radiation absorption, waterproof material. Table Accessories like stainless steel cassettes tray should be provided. Bucky should accept cassettes up to 14”x 17” POWER REQUIREMENT : The unit should be operable on 3 Phase, 440 Volts AC, 50 Hz 15 Amps with line –resist less than 0.4 ohms. Line regulation ± 10%.
APPROVALS: 1. The quoted model should be approved by AERB & BIS. 2. Company should have ISO 9001:2015, ISO 13485:2016, EN ISO 14971:2012 and ICMED 13485 certificate. Also have MD 9 License to Manufacture Medical Devices from CDSCO of quoted model. 3. Quoted X-Ray tube should be registered with quoted X-Ray machine model. 4. X-ray manufacturer is registered in MSME & NSIC. 5. Manufacturer didn’t have blacklisted /debar from any State Govt/ PSU/Central Govt institute in past Ten Years. No stay order and pending debar case is pending in Indian Penal Court. 6. Manufacturer is having 100 Nos. installation of X-Ray machines in Govt. sector in last One Year. 7. X-Ray manufacturer is having Testing & Calibration Lab with NABL approved and compliance with ISO/IEC 17025:2017 standard.
Flat Panel Detector 1. The detector should be both wired and wireless for data communication. 2. The detector should be a flat panel detector with Cesium Iodide Scintillator 3. The size of the detector should be 35 cm x 43cm (14”x17”) or more 4. Should have spatial resolution of 3 lines pair / millimeter or better 5. Pixel Pitch should be 150 micron or less 6. Detector Quantum Efficiency (DQE) should be 70% or more @ Zero lines pairs (near zero) & MTF minimum 80% at 1 cyc 7. The active-matrix size should be 2.3K x2.3K or more 8. Should have a minimum grey scale of 16 bits/ pixel 9. Detectors should be supplied with two external batteries and the supplied charger should be able to charge two batteries at a time. Detector with inbuilt battery should not be quoted. 10. The detector should be able to work without the battery also under wired mode. 11. Detector should be light weight (< 3kg) 12. Detector should have software which corrects the effect of scatter radiation on acquired image by processing, without the need of physical grid. It should be quoted as optional. 13. Withstand Load: Point Load – 100 kg or more, Surface Load – 300 kg or more 14. Detector should be CE or USFDA approved
Acquisition Workstation: 1. Should have a high resolution TFT/LCD monitor of minimum 17” size or more 2. The Console or Acquisition Workstation PC to be supplied should be of latest generation with at least 4GB RAM. 3. Operating console should have facility for patient identity entry, viewing and processing images.
DRY IMAGER SYSTEM 1. The system must have a laser printer without need of any wet chemistry. 2. It must be DICOM compatible allowing multiple modalities to be connected at a time. 3. The system must be able to print at least 70 films/ hr. of the 14" X 17" size. 4. The imager must have spatial resolution of 500 dpi minimum. 5. The system must have contrast resolution of 12 bits/ pixel or more. 6. The imager should be equipped with 2 tray on line. 7. Time Required for Startup Approx. 15 minutes under 25 o C room temperature conditions. Approx. 10 minutes under 25o C room temperature conditions in Power Saving Mode
1. Note:- The rates quoted by the bidder/s shall be final and inclusive of taxes, carriages of all materials (Mechanical/Manual) and all extra charges till the Installation, Testing of equipment/s is complete in all respects.
Health Imaging Pharmaceuticals (BID ID -2352158)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_847306.pdf
boq_comp_chart.xlsx
xlsx