Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
O/o the EE, POWER DEPTT, K.E.E.D. KURSEONG, GTA.
CONSTRUCTION OF SHELTER HOUSE FOR TRUCK DRIVERS WITH IN TRUCK STAND AT DARJEELING MORE, SILIGURI. (ELECTRICAL WORKS)
2025_GTA_978119_3
9/NIET/EE/PD/KEED/GTA of 2025-26 (3rd Call)
Open Tender
Electrical Work/ Equipment
Percentage
30 days
DARJEELING MORE
AS PER NIET
5 documents required · 5 mandatory
₹750
₹9,520
Yes
22 Dec 2025
22 Dec 2025
27 Jan 2026
22 Dec 2025
23 Jan 2026
22 Dec 2025
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing capping and Switch board both on surface]
b) Average run 6 mtr
c) Average run 8 mtr
(a) On Board
(d) Average Run 3 mtr.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
(b) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
(c) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works
25x10mm Size
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
Legrand Make 2+4 way
Legrand Make 6-32A SP
Legrand Make 40A DP
Supply & fixing sheet steel main switches on angle frame on wall 32A 240V (Havells Make)
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Fixing only bulk head ceiling fitting on wall/ceiling by screws etc.
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required
Fixing exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing 2 * 1/1. 40 P.V.C. insulated and sheathed wire and making connection for exhaust fan of dia:-
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Supplying only
(101) 6A Modular type Switch
(103) 6A Modular type 5 pin Plug Socket
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (a) By ISI-Medium GI pipe
Connecting the equipments to earth busbar including supplying and fixing 20 mm X 3 mm galvanised (hot dip) MS flat on walll/ floor with gi saddles as required and connections to equipments incl. drilling holes, with bolts, nuts, washers etc.
Supplying & fixing 50mm dia x 5.24 metre long (incl. bends) GI pipe vertical type service bracket on wall for carrying 2 wires and an earth wire complete with Galv. MS clamps for stay, insulators and earth wire, 7/14 SWG stranded GI (Hot Dip) Stay wire with 230x31 mm dia straining screws, 75x88 mm porcelain shackle insulators with Galv. (Hot Dip) strips, bolts, bush etc. incl. painting
Supply only 20W LED Tube Light (Make - Havells/Philips)
Supply only 12W LED Bulb (Make - Havells/Philips)
Supply only 50W LED street light (Make - Havells/Philips)
Supply only bulkhead light of ((Make - Havells/Philips)
Supply only Ventilating fan (Havells - Ventil Air DX HS white)
Supply only Octane Led round Surface Light
Supply only Wall fan (Havells - Sameera white)
Supply only 2 core 10 sqmm aluminium unarmoured cable
WBSEDCL formalities for new service connection
Add GST @ 18%
Add Labour Cess @ 1%
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.13 MB
Tendernotice_2.pdf
PDF • 0.78 MB
BOQ_2383813.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .