| 3 | L3₹8.8 L+₹32,015 (3.76%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹9.0 L+₹52,175 (6.13%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹9.1 L+₹59,784 (7.03%)Rejected-Finance WARD NO 07 WARD NO 07 THANA PARA NALHATI BIRBHUM WEST BENGAL 731243 | BIRBHUM | WEST BENGAL | 731243 | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
16 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF SINGARSI
AGE I AF SINGARSI
Repairs to AC Sheet Roof ceiling and parking sheads to certain building at AF Stn Singarsi Under AGE I AF Singarsi
2020_MES_355528_1
C/8481/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹17,000
Yes
14 Aug 2020
24 Jun 2020
18 Jul 2020
24 Jun 2020
16 Jul 2020
27 Jun 2020
30 days
Amount
Demolition of cement concrete in ground floors and pavings nexc 15cmm thickness belowor abve level complete all as specified and as directed by Engineer-in-Charge.
M & L for PCC type B0 1:2:4 (12.5 mm Graded stone aggregate) as in roof padding complete all as specified and as directed by Engineer-in-Charge.
M & L for PCC 1:2:4 type - B1 (using 20 mm graded crushed stone aggregate), 100 mm thick as in hard standing complete all as specified
M&L for precast factory made rectified designer paving tiles of size 300mmx300mmx25mm, glazed top portion complete made with grey cement and pigment, different colour and pattern set in joint in neat cement slurry over and including 20mm screed bed or bedding layer in CM 1:4 (colour and pattern as approved all as specified and directed.
M&L for PCC 1:2:4 type B1 (20mm graded aggregate) as in kerbs or mud stops, rounded or chamfered edges, etc
Taking down cement plaster of any description on brick or stone walls or from concrete surface incl raking out joints, hacking for key,scrubbing down with water and removing unserviceable material outside cantt area all as specified and directed by Engr-in-Charge.
M&L rendering 15mm thick on fair faces of brick work / concrete surfaces in CM 1:4 finished even and smooth without using extra cement and mixing with WPC as per manufacturers instruction complete all as specified and as directed by Engineer-in-Charge. Note:- WPC will be measured and paid separately.
Cleaning the roof surfaces and applying bitumen primer @ 0.30 kg/sqm, providing and laying 3mm thick APP modified water proofing membrane weighing not less than 3.00 kg/sqm reinforced with non woven polyester mat weighing not less than 160 gm/sqm, having softening point not less than 800 N /Sq cm, tearing strength of 180N, with minimum of 10 cm side laps and 15cm end laps, laying by application of torch, and applying industrial bitumen 85/25 @ 1.2 kg/sqm on top surface complete all as specified and as directed by Engineer-in-Charge.
Supply only liquid water proofing compound.
Dismantling PVC water storage tanks of capcity exc. 250 litres & n. exc. 500 litres and removing from site complete all as specified and as directed by Engineer-in-Charge.
S&F for 1000 Ltrs rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of multi-layer, hoisted and fixed in position all as specified in SSR Part-l, after dismantling of old water tank (PVC) and removing from site.
Disconnecting existing tanks (exc 250 & n exc 500 ltrs capacity),setting aside for repairs,cleaning,etc and hoisting if required reconnecting and re-fixing in position.(Cleaning repairing,etc measured separately)
S&F for 15mm dia GI tubes (medium grade) with all fitting and fixed complete to walls and ceilings or laid in floors after taking up or down old unserviceable tubing and connections.
S&F for 20mm dia GI tubes (medium grade) with all fitting and fixed complete to walls and ceilings or laid in floors after taking up or down old unserviceable tubing and connections.
S&F for 15mm bore stop valve , fancy type, chromium plated with long shank and cup (concealed type) cast copper alloy screwed down high pressure, with cruth or butterfly handle, screwed both ends for iron pipe as in repair all as directed.
S&F for 15mm dia bib taps, cast copper alloy chromium plated with crutch or handles screwed down, screwed for iron pipes as in repairs.
S&F for PTMT ball valves high pressure with apoxy coated aluminium rod & high density plastic ball screwed for 20mm dia pipes all as specified and directed as in repair, (minimum weight 210 gms)
Dismantling old AC sheet ceiling/eves boards, any description, fixed in any position with nails including wooden scantling complete all as specified and as directed by Engineer-in-Charge.
S & F 6 mm thick asbestos cement plain building boards in ceiling fixed to timber framework with screws fixed in repairs complete all as specified and as directed by Engineer-in-Charge.
S&F anodised aluminium snap grid size 605X 605mm frame work for false celling allas specified
S&F for 15mm thick 2nd class hard wood boards eves board clean sawn butt joints fixed with nails or screws/ nut and bolts in any situations and in any conditions complete all as specified and as directed by Engineer-in-Charge.
M&L 2nd class hardwood Plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails forframework sectional area exc 13 sq cm and n'exc 25sq cm complete all as specified and as directed by Engineer-in-Charge.
M&L Preparing new AC sheet ceiling surfaces and applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge.
M&L Preparing old AC sheet ceiling surfaces and applying one coats of white wash complete all as specified complete all as specified and as directed by Engineer-in-Charge.
Preparation of new Surfaces of any description with one coat of pink primer and two coats of synthetic enamel paint, not otherwise described , over 10 cm width or girth complete all as specified and as directed by Engineer-in-Charge.
S&F PVC(SWR) pipes in repairs 110mm dia for rain water pipes in single socketed in any length with rubber ring joints fixed to walls with including MS/PVC bracket complete all as specified and as directed by Engineer-in-Charge.
S&F PVC (SWR) bends 110mm dia in any radius complete all as specified and as directed by Engineer-in-Charge.
Cutting chases, pinning in, Brick/stone walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps cills, sunshades, shelves,lintels etc; and cutting chases for inserted AC/Steel sheet in walls and making good, cutting exc.10CM but n'exc20CM girth complete all as specified and directed by Engineer-in-Charge.
M/S AMARNATH AGARWALLA
P .BANERJEE AND CO
M/S Subhadip Enterprise
M/S New Builders Corporation
M/S KUMAR AVINASH
M/S AWDHESH KUMAR CO AND BROS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .