INTERNAL ELECTRIFICATION OF PANCHAYAT GHAR AT PYT HALQA DEDMURIBAGH BLOCK CHADOORA
2026_RDPR_305365_8
NIT_142_REW BUDGAM OF 2025-26_PG_ELECTRIFICATION
Open Tender
Civil Works
Percentage
30 days
CHADOORA
AS PER ENIT
3 documents required · 3 mandatory
₹200
Executive Engineer REW Budgam
₹6,930
13 Mar 2026
6 Mar 2026
13 Mar 2026
6 Mar 2026
12 Mar 2026
6 Mar 2026
Wiring for light point/ fan point/exhaust fan point with 1.5.sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in existing surface /recessed medium class PVC conduit ,with modular switch(Anchor roma urban /eq.make),base plate ,cover plate ,suitable modular GI box and earthing the point with 1.5 sq mm FRLS /HFFR PVC insulated copper conductor single core cable etc as required (Havells /Legrand/roma urban/Eq.make as par ISI Standard Note The GI boxes can be of different sizes of Modulues to hold the Modular Boxes and Modular Switches for lights/fans/exhaust fans and are included in the point rate
Supply ,fixing,drawing testing and commissioning of 3x2.5 sqmm FRLS/HFFR PVC insulated copper conductor (Havells/Anchor/Eq.make),single core cable in existing surface /recessed medium class PVC conduit. Note This includes Three wires (Phase , Neutral and earth ) and 1 Ckt meter is equivalent to 3 meters
Supply ,fixing,drawing testing and commissioning of 3x4 sqmm FRLS/HFFR PVC insulated copper conductor (Havells/Anchor/Eq.make),single core cable in existing surface /recessed medium class PVC conduit Note This includes Three wires (Phase,Neutral and Earth) and 1 Ckt meter is equivalent to 3 meters
Supply of fixing of 25 mm size PVC condute along with accessories(bends,sockets,iron staples/saddles/screws,pvc fastener etc) in surface /recess include in cutting the wall and making good the same by cement sand and paint in case of recessed /Surface condute as required for Walls
Supply of fixing of Suitable GI Box with Modular Plate and cover in front on surface or in recess including providing and fixing of 3 pin 5/ 6 amp and 15/16 amp /230 V AC modular socket and 15/16 amp modular switch(Anchor Ro urban/SSK NV/Havells /Eq.make)
Supply of fixing of Suitable GI Box with Modular Plate and cover in front on surface or in recess including providing and fixing of 3 pin 5/ 6 amp and 15/16 amp /230 V AC modular socket and 15/16 amp modular switch(Anchor Ro urban/SSK NV/Havells /Eq.make)
Supply installation testing and commissioning of 1200 mm dia sweep of standard make
Supply of fixing of 6 amp /230 V AC fan dimmer step type 2 module with cover plateAnchor Ro urban/SSK NV/Havells /Eq.make.
SITC of 230-250 mm dia Sweep Exhaust Fan with ceiling rose of standard make
S/F testing nd comm..of recessed /surface mounted 12 watt LED down lighters SMD type system Luman efficacy >= 100<120 lm/watt Philips /havalles /bajaj/Crompton make of eq. standards having alluminium body Commercial Type
SITC of 20 watt LED bulk lights of standard make (Complete Job)
Suppling and fixing of 16 way horizontal type single pole and neutral sheet steel,MCB distribution board ,240 V ,On surface /recess,complet with neutral bus bar,earth bar,din bar interconnection ,powder painted including earthing etc .as required .(But with out mcb/ Rccb/Isolator ):-Hager /Legrand /ssk/equt .standard
S/F testing and comm..of MCB of the below mentioned capacities in sub main control legrand C curve series 6-32 Amp SP MCB
S/F testing and comm..of MCB of the below mentioned capacities in sub main control legrand C curve series 40-63 Amp DP MCB
Supply ,laying partly overhead partly underground ,testing and commissioning of 16sqmm Two Core Al cable of standards make
SITC of 63 amp 4 way Connectror including Providing of 3x10sqmm FRLS cu wire(5 Ckt mtr) from Mains DB to Connector to be installed outside the building
Earthing with GI earth pipe 2.15 metre long (2Nos), 40mm dia including and providing Masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal/coke/salt as required along with 10 SWG GI wire /25/3 mm GI Strp upto the nearest point of earth to be supplied/drawn from main same (complete job) as per the directions of engineer incharge
stage.html
html • 0.03 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_991893.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .