Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC 41 BIDHANGARH SOUTH KOLKATA 700066 | KOLKATA | KOLKATA | WEST BENGAL | 700066 | L1 | Accepted-AOC Quoted Lowest Rates | |
| 2 | L2₹16.1 L+₹2.5 L (18.2%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L2 | Rejected-Finance Quoted Higher Rates | |
| 3 | L3₹18.8 L+₹5.2 L (38.0%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L3 | Rejected-Finance Quoted Higher Rates | |
| 4 | L4₹19.0 L+₹5.4 L (39.8%)Rejected-Finance 0 KALIKAPUR KALIKA PUR CHAMPAHATI SOUTH 24 PARGANAS WEST BENGAL 743330 | 24 PARAGANAS SOUTH | WEST BENGAL | 743330 | L4 | Rejected-Finance Quoted Higher Rates | |
| 5 | L5₹19.4 L+₹5.7 L (42.1%)Rejected-Finance | L5 | Rejected-Finance Quoted Higher Rates |
Tender Value
Refer Docs
EMD Value
₹31,100
Closing Date
25 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ SWAPNESH KOLI GE I CG P KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
AUGMENTATION OF PERIMETER SECURITY AND STREET LIGHTING AT SSB DIAMOND HARBOUR AND PROVISION OF UNDERGROUND ELECTRIC CABLE FOR POWER SUPPLY OF NEW SENTRY POST AND PROVISION OF SPLIT ACs AT NAVAL EXCHANGE AT INS NETAJI SUBHAS UNDER GE (I) (CGP) KOLK
2020_MES_392943_1
8877/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KOLKATA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE I CG P KOLKATA
₹31,100
Yes
31 Dec 2020
5 Nov 2020
27 Nov 2020
5 Nov 2020
25 Nov 2020
19 Nov 2020
60 days
Amount
Excavation in trenches, n. exc. 1.5m wide and n. exc. 1.5m in depth; for laying of cable, n. exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point
M&L fine sand, filling in trench for cable cushioning and gently punned down by manually with hands complete all as specified and directed.
Material and labour Brick protection cover to LT underground cable with Sub Class 'B' over burnt laid dry and flat abutting each other with gaps between adjacent bricks not exceeding 10 mm complete specified and directed
M&L PCC 1:2:4 type B-1 type (using 20 mm graded crushed stone aggregate) as in coping including necessary form work complete all as specified and directed.
M&L PCC 1:3:6 type C-2 type (using 40 mm graded crushed stone aggregate) as in pole/LT panel foundation complete all as specified and directed.
Supply and laying tubes 40 mm dia steel water tube light grade galvanised with all fittings laid in trenches complete all as specified and as directed.
Excavation in trenches, n. exc. 1.5m wide and n. exc. 1.5m in depth; for laying of cable, n. exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard rock soil.
M&L for road cutting for laying of LT UG cable / galavanised iron pipe and making good disturbed surface complete all as as specified and directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 10 Sqmm 4 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 16 Sqmm 4 core complete all as specified and as directed.
M&L for wiring with two runs of 2.5 sqmm (Nominal area) single core PVC insulated multistranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through and including PVC RIGID CONDUIT with all fittings fixed to pole incl one run of 1.5 sqmm (nominal area) single core, PVC insulated multistranded unsheathed FRLS copper conductor as earth wire complete all as specified and directed. (Note :-(i) One run of PVC conduit, two runs of 2.5 sqmm single core cable, one run of 1.5 sqmm earth continuity wire to be measured as one length).
M&L for Steel tubler swaged poles complete with cast iron base plate finial taper plug, bolts, nuts and screws,with two holes for drawing conductor between pole box to street light fitting all as specified type 410 SP-31 of height 9M including painting with two coats of aluminium paint over one coat of primer including Zebra marking with synthetic enamel paint and applying black bituminious paint to the buried surfaces in ground. NOTE: Earth work,PCC will be measured and paid separtely under relevent item of this Schedule.
Supply and fix MS Bracket made of 50mm dia MS pipe medium grade 1.5mtr long suitable for street light on steel / RCC pole as per site requirement including suitable nut,bolt and clamps complete accesseries all as specified and directed .
Supply and fixing of LED street light 120 W IP 66 with all fittings accessories complete all specified and directed. Make: CG cat part No LSTP-120-CDL-M or equivalent Havells /Bajaj/philips
Supply and fixing FRP street light box size - 300x200 x125 mm with DIN rail for MCB including 4 Pole PVC connector with all fittings complete all specified and directed.
Supply and fix MCB SP 240V, 6-32 Amps capacity complete all as specified and directed. (Make : Legrand cat No 4085 87-95 or equivalent in Schneider/GE )
Supply, Install, design, testing and commissoning outdoor floor mounted pannel of size 1200mm x 800mm x 600mm cubical size . Panel made of 3.15 mm thick MS CRCA sheet and angle iron structure 40 x 40 x 6 mm, CPRI approved varmin proof compartmentalized double door, type of size as required including loking arrangement and two coat of powder coated paint over a coat of red oxide primer, fixed in floor with MS angle iron 40 x 40 x 6 mm frame structure and grouted with PCC M-15 (Nominal mix) using 20 mm graded stone aggregate with and including 2.5 /4.0 sqmm single core copper FRLS/HRFR wired connection, brass cable gland for cable entry etc. having following accessories :- (a) LED lamps 03 Nos (R, Y, B) - 1 Set (b) Digital Voltmeter 0-500 Volts - 01 No (c) Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed,industrial multistrand copper cable 1100 V grade cable , including provision of lugs/thimbles on either ends of cable. (d) Digital Ammeter - 01 No. (e) Inter connection of MCCBs with bus bar with suitable size copper strip/PVC insulated, unsheathed , multi stranded copper conductor cable, 1100 volts grade. INCOMING :MCCB 63 Amps 4 Pole, 25 KA Braking Capacity- 02 Nos Make: Legrand Cat No. 4200 53 or equiv in Siemens/Schneide . OUTGOING : (1) MCB TPN 32 Amps - 01 Nos, Make : Legrand cat No 4086 80 (2) MCB DP 10 Amps - 02 Nos, Make : Legrand cat No 4086 31 (3) MCB SP 10 Amps - 03 Nos, Make : Legrand cat No 4085 90 (4) Contactor ML-2 - 01 Nos (5) street light timer FM1 / Quartz Daily 240V AC Base/DIN Mounting analogue type - 01 Nos Make : L & T Cat no. AUTS01ANA00 or equivalent of
M & L earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected with 4mm dia GI wire by means of bolts washers and protected by 15mm bore, medium grade GI pipe, funnel with 20mm bore GI medium grade watering pipe, wire mesh, copper lugs including concrete pit in PCC 1:3:6 type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350X350X50 mm, reinforced with 8mm dia deformed bars @15 cm C/C both direction and 10mm MS handle of suitable size, charcoal or coke and salt in alternate layers, necessary earth work in soft/loose soil, all as shown in Electrical Plate No 3 of MES Schedule Part-I and testing, complete all as specified and as directed.
Supplying, Installation Testing & Commissioning hi wall Split type AC unit (both indoor & out door units) complete with cordless remote control with in built air ioniser and Plasma filter for better indoor air quality, rotary compressor 5 star rating, 1.5 TR capacity, copper condenser along with supply & connection of copper tube, electric cable & insulating cover, 15 mm dia flexible heavy duty PVC pipe for water drainage of AC, supply & fixing of suitable size MS angle iron bracket /clamps with nuts bolts duly painted for setting outdoor unit including necessary drilling in wall for passing of copper tube & drainage pipe & making good the disturbed surfaces of wall including necessary electric connection between indoor & out door unit complete all as specified and as directed. (Make Hitachi/ LG / Samsung / Blue Star /Hitachi)
Supply and fix voltage stablilizer for autmatic operation , single phase naturally air cooled indoor with wall mounting type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy +-2.5% and capacity 5.0 KVA complete all specified and directed.
S&F for Power unit 6M flush type with AC starter, 20Amps MCB & 20Amps Plug top with indicator, 6module plate including connection complete all as specified and as directed . Make : Northwest Cat No ACPU6M-FT or equivalent.
M&L point wiring with 4.0 Sqmm (nominal area), PVC insulated, stranded single core unsheathed HRFR / FRLS copper conductor cable 1100 Volts grade drawn through with and including PVC conduit medium duty (ISI marked) not less than 20 mm dia and all fittings and accessories (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 4.0 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core HRFR / FRLS copper cable as earth continuity wire connecting to common earth point including 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for three pin 15 Amp socket outlet on independent board complete all as specified and directed.
MS AP CONSTRUTION AND CO
M A ENTERPRISES
GHOSH ENTERPRISE
UJJAL ELECTRIC
MS HORIZEN
RANJIT KUMAR HALDER
CHOWDHURY SMALL INDUSTRIES
R R ENTERPRISE
M/s Santosh Industrial Corporation
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .