Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.0 LAccepted-AOC | 1 | Accepted-AOC Awarded being L1 | |
| 2 | 2₹25.5 L+₹45,714.42 (1.83%)Rejected-Finance 3RD FLOOR 105 NAGDEVI STREET MASJID BUNDER WEST MUMBAI MAHARASHTRA 400003 | MUMBAI | MAHARASHTRA | 400003 | 2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | 3₹26.0 L+₹95,356.80 (3.81%)Rejected-Finance 80 G HIMMATGANJ PRAYAGRAJ U P PIN 211016 | PRAYAGRAJ | UTTAR PRADESH | 211016 | 3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | 4₹26.6 L+₹1.6 L (6.26%)Rejected-Finance | 4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | 5₹26.7 L+₹1.7 L (6.60%)Rejected-Finance | 5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
23 Feb 2022, 6:00 pmClosed
Garrison Engineer (P) Allahabad
Garrison Engineer (P) Allahabad New Cantt Allahabad
PROVN OF 02 X TOILET BLOCK, BOUNDARY WALL For 600 SEATER AUDITORIUM CUM CINEMA HALL AT NEW CANTT ALLAHABAD
2021_MES_496254_2
8254/P/E8
Open Tender
Civil Works
Item Rate
270 days
NEW Cantt Allahabad
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
Garrison Engineer (P) Allahabad
₹59,000
Yes
26 Apr 2022
2 Feb 2022
25 Feb 2022
2 Feb 2022
23 Feb 2022
9 Feb 2022
Amount
Excavating in trenches n. exc 1.5 m width and n. exc 1.5 m in depth for foundation etc or for shafts, wells,cesspits , manholes , pier holes etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed.
M&L for PCC 1:4:8 type D2, using 40mm graded stone aggregate, as in foundation filing,sub base of floor complete all as specified and as directed
M & L Brick work with fly Ash old size bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6 complete all as specified.
M & L for brickwork with Fly ash bricks straight or curved on plan To Any Radius in half brick thick wall built in (1:4) cement mortar all as specified.
Returning filling in ,including spreading ,levelling,watering and well ramming in layers n exc 25 cm soft/ loose soil complete all as specified and as directed.
Spreading and levelling of soil in layers n exc. 25 cm thick with well ramming including watering as required for filling under floor complete all as specified.
Removing excavated material exc 250 m but n exc 500 m distance and depositing as directed.
M & L 100 mm thick PCC (1:4:8) type D-2, using 40mm graded stone agg as in sub base of flooring all as specified.
Supply only integral water proofing compound.
M & L for DPC in PCC (1:2:4) type B-0 to horizontal or vertical surfaces including necessary formwork 40mm thick.
M & L Rendering 12 mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on other than fair faces of brick or concrete surface finished even and smooth complete without using extra cement.complete all as specified and directed.
M&L for 5 mm thick rendering in CM 1:3 on ceiling surface finished even and smooth complete without using extra cement.complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed
Form work to sides and soffit of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc rough finished complete all as specified and as directed
Formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surface complete all as specified and as directed
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed .
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. (Note for item No 18, 19, 20 & 21 : Steel reinforcement shall be measured and paid seprately)
M&L TMT bars of 10mm dia and over in reinforcement cut to length bent to shape required including cranking bending and binding with mild steel annealed wire not less than 0.90 mm dia or securing with clips and as straight in groves complete all as specified and directed.
M&L for Mild steel bars (TMT bars) 5mm dia and over upto and including 10mm dia in strriups,spaces,nibs and binders complete all as specified and as directed.
M&L for hardcore of gauge n exc. 63 mm,of broken stone deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate in plinth protection finished even and smooth without using extra cement including necessary formwork and cutting of joints complete all as specified.
Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
M& L for Preparation of newly plaster surface of wall and applying two coats of oil bound distemper over a coat of 3 mm wall putty complete all as specified and directed.
M& L for Preparation of newly plaster surface of wall and applying two coats of cement base paint including one coat of alkali resistant primer complete all as specified and directed.
Material & labour for preparation of new plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
S & F steel ventilators with top hung shutter including hinges steel peg stay complete all as specified and directed.
M & L for Glazed ceramic coloured , any pattern tiles 7 to 8 mm thick area of tile exceeding 0.13 and n.exc 0.18 Sqm in skirting, dados, risers to steps etc and jointed in neat cement slurry and painted in coloured cement to match tiles over and including 10 mm thick rendering or backing layer in cement mortar 1:4 complete all as specified and directed.
M & L for joint free non skid, ceramic coloured, any pattern tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm thick, in floor, shelves etc, set and jointed in neat cement slurry & pointed in colour of cement to match the shade of tiles over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete of item all as directed.
S & F 100 mm dia sand cast iron soil waste and vent pipes sand cast in any length with or without laid in trenches or in floor with cement joints all as specified and directed.
S & F 100mm dia cast iron floor trap with grating including to waste pipe in run lead complete all as specified and as directed.
All as per ser item No 34 here in before but with oval access door.
S&F for SGSW gully trap type 'P' 150 x 150 mm size complete all as specified and directed.
M & L for 15 mm dia steel tube medium grade galvanized with all fittings and fixed complete in wall, ceiling or laid in floor complete all as specified and directed.
M & L for 20 mm dia steel tude medium grade, galvanised with all fitting and fixed complete to wall, ceiling or laid in floor complete all as specified and directed.
M & L for 25 mm dia steel tude medium grade, galvanised with all fitting and fixed complete to wall, ceiling or laid in floor complete all as specified and directed.
Cutting chases, pinning in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cuttings chases for concealed water tubing and making good, cutting not exc 10 cm girth.
S & F 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
S & F 20 mm bore Gun-metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F 25 mm bore Gun-metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed.
S & F fancy type bib taps two in one 15 mm bore cast copper alloy Chromium Plated Hindware Cat Part NO F400003 or equivalent with wall flange screwed for iron pipe or brass ferrule all as specified & directed .
S & F pillar cock for WHB, cast copper alloy with half/ quarter turn, Hindware Cat No F320001 OR EQUIVALENT fancy type, chromium plated, screwed down high pressure, long screwed shanks and fly nuts, screwed for iron pipe 15 mm bore complete.
S & F angular stop cock 15 mm bore fancy type, chromium plated with long shank and cup of Hindware Cat Part No F320006 or equivalent complete all as specified and directed.
S & F Brass chromium plated bottle traps 32 mm bore for wash basins with inlet and outlet srewed for pipe or connection including necessary packing union and cap and fixed.
S & F Brass chromium plated bottle traps 40 mm bore for Urinals with inlet and outlet srewed for pipe or connection including necessary packing union and cap and fixed.
S & F PVC connection 15 mm size with PTMT nuts of length 450 mm of approved quality all as specified and directed.
S & F PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality all as specified and directed.
Supply and fixing viterous china wash down water closet pan (pedestal pattern) white and trap Hindware Cat Part No 20058 (P-15.5) or equivalent including connection to drain (or outgoing pipe) and to fluhsing pipe, antisyphonage pipe, cover etc complete all as specified and directed.
S & F vitreous china urinals bowl, flat back large of size 260x310x415 mm pastel Hindware cat part No 60011 with sensor Hindware Cat Part No 500963, or equivalent grating and union for discharge pipe complete including providing and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with and including 60 mm long brass screws pointing around urinal back in cement complete all as specified.
S & F vitreous china table top wash hand basin, flat bottom of size 600x430x130mm pastel suitable for mounting on granite slab at Hindware cat No 91098 or equivalent square/ rectengular shape as approved including 32mm dia chromium plated waste coupling complete all as specified and directed. Make- Hindware
S & F wall mounted liquid Soap dispensor Glass bottle with brass fittings complete Jaguar Cat No ACN-CHR-1135N or equivalent of appoved quality all as specified and directed.
S & F Tubular Towel rails of 20 mm dia, 600 mm long of Stainless Steel fixed with CP screws and wooden cleats complete all as specified and directed.
S & F frameless looking mirror 6 mm thick glass of slected quality bevelled edge fixed with SS Screws/Stud with nead of screw not less than 20 mm complete all as specified and directed.
S & F 500 litre capacity rotational moulded poyethylene water storage, tanks (Cylindrical, vertical with closed top) hoisted and fixed in position including all fittings all as directed.
Cutting into existing manhole/ Septic tank for connecting new drain making good to pipe and rendering cutting out existing bending in cement 1:2:4 type B1 smooth finished and reforming benching as required all as specified and directed.
M & L concreting bed to drain pipe including packing under and haunchig againt the sides of pipes after they are laid and tested PCC 1:4:8 type D2 for 150 mm bore pipe complete all as specified and dirtected.
M & L SGSW drain pipes of 150 mm bore pipes laid and jointed all as specified and directed.
M & L for rendering 15 mm thick in 1:4 on fair faces of brick work or concrete surfaces mixing WPC @ 3% by wt of cement finished even and smooth using extra cement. (Note : WPC will be measured & paid separatly.)
Providing Precast cement concrete (1:2:4) type B-1, using 20 mm graded crushed stone aggregate as in manhole /drain cover slabs etc and set in cement mortar 1 : 4 complete all as specified and directed.
Providing PCC (1:2:4) type B-1 using 20 mm graded crushted stone aggregate as in coping including weathering, slightly rounded of chamfered angles and throating including necessary form work complete all as specified and as directed.
Extra over for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitered/stopped ends all as specified & directed. (NOTE: Inner girth shall be measured)
Add or deduct on item No 64 above for each 25 mm girth or part there of over or under 30 cm girth.
M & L for Plain Cement concrete type C-2 (1:3:6 (using 40 mm graded stone aggregte) as in foundation filling and mass concrete sub base of footpath complete all as specified and directed.
M & L for laying of 60 mm thick M-35 grade factory made coloured rubber moulded machine pressed precast concrete interlocking paver block (glossy type) in approved design and colour conforming to IS-15658-2006 with grey cement and pigment as approved laid over and including 25 mm thick sand cushion and joints filled with sand complete as specified and directed.
S & F 4 mm thick sheet figured glass , pin head type and glazing with oil putty in squares n.exc. 0.50 sqm in each pane complere all as specified and directed.
S & F Health faucet including pipe 1.00 m long with brass nuts for EWC fixed complete all as specified and directed of make Hindware Cat Part No F160068 or equivalent as approved.
S & F white Toilet paper holder box type all as specified and directed.
S & F Solid PVC Double door frame of size 50 mm x 95 mm made out of 5 mm single side prelam PVC sheet reinforced with MS tube suppling & fixing in opening as per specification.
S&F 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and jointed at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickenss. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm ( + 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by insering horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as specified by the manufacturer and as per directions of Engineerin- charge.
S&F 250 mm aluminium alloy, anodised sliding doorbolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sictions and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete.
S&F 100mm size Butt hinges extruded aluminium alloy with galvanized mild steel hinges pin anodized and fixed type C-21 complete all as specified and directed.
S&F 150mm size aluminium anodized barrel tower bolt of extruded section and fixed
S&F 150mm size aluminium cast type anodized handle all as specified and directed.
S&F Tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and staining bolts conforming to Fe 290 Gde-E-165 all as specified and directed.
S& F Framed brackets of angles or tees with web and flanges cut to shape, drilled and contersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel')
S&F steel work in tubular trusses, Rafters and purlins including special shaped washer etc. complete using washer etc. complete using ERW or induction butt weided tubes sonforming to I.S. 1161-1979 grade St-240
M&L preparation of newly steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Pre-painted galvalume aluminum zink coating GI based of mangular pattern designed steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & F wall-mounted ABS Plastic High Speed 1800 W European Automatic hand Dryer with blowing volume not less than 150m3/h brushed type motor DOLPHY Cat No. DETUAMHDRY001_B or equivalent complete all as specified.
S & F sheet glass shelf assembly with chromium plated bracket guard of Hindware Cat Part NO F870011 or equivalent as approved by GE complete all as specified.
M&L for 10mm thick plaster in CM 1:3, mixed with liquid water proofing compound @ 200 ml per bag of cement when concrete is green,finished even and smooth without using extra cement complete all as specified and directed. (Note:- Liquid water proofing compound to be measured and paid separately)
M&L for normal water proofing treatment on roof slab consisting with following operation (i) Existing surface shall be cleaned of all dust, fungus, moss and other foreign material etc by using wir brush & dusting, Apply a layer of bituminous primer conforming to IS 3384 @ 0.4 Lit/m2 on the surface.Applying hot blown grade 85/25 bitumen as per IS 702-1988@ 1.2 Kg/Sqm over bituminous primer. Laying 3mm thick APP membrane habing non-woven polyester matt at core and under surface coated with plastic polythene film. Laying shall be done using butane torch maintaining 100mm ie overlap & 150mm end overlap, sealling all overlaps complete including treatment at all junctions & corners. The membrane shal be tucked into groove on vertical plane and groove sealed with cement mortar. The treatment shall be provided upto 200mm height above finished floor (Note- The membrane shall have tensile strength of 700N/5cm in longitudinal direction and 450N/5cm in transverse direction at 23 degree celcius, Flow resistance>120 degree celcius, dimensional stability, < 0.5% when tested as per ASTM D 5147. The laying of the membrane shall be done through authorized applicator of the manufacturers' (ii) Applying two coats of bituminous aluminium paint @ 0.30 L/m2 over the APP membrane indicated above.
Supply only Liquid water proofing compound (ISI marked) complete all as spesified and directed.
Point wiring complete for One light /Fan /Exhaust fan point controlled by one switch with PVC insulated and unsheathed ,FRLS cable 1.5 sqmm (nominal area) ,ISI marked,multi-stranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and MS conduit in roof/ floor slab, pressed GI concealed termined boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC ,FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories complete all as specified and directed.
Point wiring complete for One 5 pin 5 Amp switch socket out let point on an independent board with PVC insulated and unsheathed ,FRLS cable 1.5 sqmm (nominal area) ,ISI marked,multi-stranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and MS conduit in roof/ floor slab, pressed GI concealed termined boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC ,FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories complete all as specified and directed
Point wiring complete for One 5 pin 5 Amp switch socket out let point on same board with PVC insulated and unsheathed ,FRLS cable 1.5 sqmm (nominal area) ,ISI marked,multi-stranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall / roof/ floor slab,pressed GI concealed termined boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC ,FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories complete all as specified and directed
Point wiring complete with PVC insulated and unsheathed,FRLS cable 2.5 sqmm (nominal area) ,ISI marked,multi-stranded copper conductor single core including ISI marked 20mm dia PVC conduit medium grade concealed in wall and MS conduit in roof / floor slab, pressed GI concealed termined boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm,FRLS cable PVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories complete for one 3 pin socket out let 15 Amps independent, all as specified and directed.
S&F Modular switch 1 way 6A, 1 module complete all as specified and directed
S&F Modular switch 1 way 16A, 1 module complete all as specified and directed
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed
S & F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed
S & F Metal flush box 6 module complete all as specified and directed
S & F Metal flush box 4 module complete all as specified and directed
S & F White cover plate with frame, 6 module complete all as specified and directed
S & F White cover plate with frame, 4 module complete all as specified and directed
M&L ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as specified and directed
M&L for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed
S&F MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure double door type complete all as specified and directed
Supply and fixing SPN 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified & directed.
Supply and fixing SP 6 To 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified & directed.
Submain wiring with Two single core 6 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- Two run of 6 sqmm copper conductor, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit.
Supply and fixing LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed.
Supply and fixing LED motion sensor lights fitting 1x 10W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed.
Supply and fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified & directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed.
M&L for Earthing complete with GI wire 4 mm dia with galvanized cast iron earth plate electrode of size 600x600x6.00mm buried in ground vertically to a depth not less than 2.25 mtrs below ground level, earth plate shall be packed on all side with charcoal mixed with salt to thickness of 150 mm connected to GI earth wire, 4 mm dia (8 SWG) protected by GI pipe 15 mm bore light grade and watering pipe 20 mm dia light grade 2.25 mtr long including necessary earth work and disposal of surplus soil to a distance not less than 50 m, chamber of PCC (1:4:8) type D2 using 40 mm graded stone aggregate coping shall be of PCC (1:3:6) type C1 using 20 mm graded stone aggregate with 50 mm thick precast RCC cover (1:2:4) type B1 (using 20 mm graded stone aggregate) reinforced with 8mm dia TMT bars @ 80mm c/c both ways including of CI pit cover and angle iron frame including frame funnel, wire mesh GI earth wire, 8 SWG under the earth and on the pole up to a height og 1.5 m shall be protected by 15 mm dia GI pipe (light grade) GI pipe to be fixed with pole by means of 2 Nos falt iron clamps 25 x 3 mm size complete with nuts, bolts and washers etc all as specified and shown in electrical plate No. 5 Note:- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
S&F LED bulb 10 Watt for B22 holder complete all as specified and directed Make:- Havells/Philips/Wipro
Supply,laying,jointing,testing and commissioning of LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 Core marked laid in trenches/duct/fixed to pole/walls/laid under road rossing / paths / drains / culvert or encased in GI pipe complete all as specified and directed.
Sand cushioning (dry sand) to under ground cable for cable protection in layers of 23cm thick ( 8 cm thick before laying of cable and 15cm thick after laying of cable) in trenches complete all as specified & directed. Note:- Only puned layers shall be measured.
Supply and laying sub class 'B' brick old size laid flat in trenches across the length for protection of cable as cable cover complete all as specified and directed .
S&F 25 mm dia Galvanised steel tubing light grade with all necessary fittings laid in trenches, fixed to walls, poles, under road/ floor etc for cable protection, complete all as specified and directed.
Supply and laying pipe galvanised iron medium class including all fittings 25 mm dia laid in trenches complete all as specified and directed.
M&L for construction of bricks masonary valve pit chamber of size 450 x 450 x 450 mm (internal dimensions) including necessary excavation and earth work and MS sheet cover 3mm thick and angle iron 50x50x6 mm frame including locking arrangements with lock and key of 50 mm lock duly painting of steel surface in two coat of synthetic enamal paint over one coat of red oxide primer complete all as specified and directed
S&F gun metal gate valve of 25 mm dia with iron wheel head screwed both end ISI marked complete all as specified and directed.
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia of 20 mm complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surface finished even and smooth complete without using extra cement.complete all as specified and directed.
M&L for exterior ceramic coloured tiles in vertical surface area of each tile exc 0.13 and n exc 0.18 Sqm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface over 10mm thick backing coat in cement mortar 1:4 all as specified and directed.
M& L for Preparation of newly plaster surface of wall and applying two coats of cement base paint including one coat of alkali resistant primer complete all as specified and directed.
BALAJI INDUSTRIAL CORPORATION
Raghvendra Enterprises
Technological Associates
Siddhi Constructionn
SK ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .