Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.7 L+₹3.0 L (7.02%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹46.8 L+₹4.1 L (9.50%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹49.5 L+₹6.8 L (15.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹50.0 L
EMD Value
₹99,980
Closing Date
12 Jun 2025, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur, Po-Garhi, Pin-182121
Repair/Maint of fencing, drain, path, culvert and retaining wall, toe wall at GE (Utilities) AOR and internal wiring, light fitting, switch sockets, LED fittings along with connected accessories in CHNC and other areas under GE (Utilities) Udhampur
2025_MES_702514_2
GE/U-92/2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
As Per NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹99,980
18 Jul 2025
15 May 2025
16 Jun 2025
15 May 2025
12 Jun 2025
29 May 2025
Amount
Demolition of PCC in ground floors & pavings n exc 15 cm thickness below or above ground level, unreinforced and removing the rubbish out side MD land, complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engr-in-charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engr-in-charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precastconcrete articles, complete all as specified and directed by Engr-in-Charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge.
All as per item No 05 here-in-before, but except Bricks, complete all as specified and directed by Engr-in-Charge.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar 1:6 , complete all as specified and directed by Engr-in-Charge.
All as per item No 07 here-in-before, but except stone, complete all as specified and directed by Engr-in-Charge.
M&L for Precast cement concrete Block (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in bond stones set in cement mortor 1:6 all as specified and directed.
Extra over stone walling for hammer dressing with miximum depression on face from straight edge held against the dressed surface not exceeding 20 mm to face stones (Granite or Trap stone) and dressing of face beds and joints, as specified of random rubble walling, uncoursed or brought upto courses , complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4, type B-1 using 20mm graded stone aggregates as in coping, fixing angle iron etc (including necessary form work), complete all as specified and directed by Engr-in-Charge.
S&F PVC 110mm dia pipe in any length with rubber rings joints laid as in weep holes , complete all as specified and directed by Engr-in-Charge.
M&L for hand packing (any thickness) at back of wall over arches etc. and rising (or lowering) to the required labour , complete all as specified and directed by Engr-in-Charge.
M&L for Raised pointing to stone masonary wall in cement mortar 1:3 ,complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:3:6 type C1 (using 20 mm graded aggregate) in surafce channel and drains, complete all as specified and directed by Engr-in-Charge.
M&L for extra for forming fair finished drain or channel 45cm inner girth in cement concrete, using extra cement, incl forms moulds, mitered/stopped ends etc , complete all as specified and directed by Engr-in-Charge.
M&L for 300 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars , complete all as specified and directed by Engr-in-Charge.
M&L for 450 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars , complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete 1:4:8 type D2 (40mm graded aggregate) as in foundations, filling and mass concrete,(bedding, packing and haunching against the sides of pipes) , complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster including tiles of any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engr-in-charge.
Rendering 15mm thick in cement mortar 1:4 on faces of bricks work/stone work/concrete surface finished the surface even and smooth(without using extra cement) as on walls, complete all as specified and directed by Engr-in-Charge. Notes :- Plaster shall be carried out upto any height in patches and contractor shall have no claim for height and scaffolding what so ever is required to complete the work.
Rendering 15mm thick in cement mortar 1:6 on faces of bricks work/concrete surface finished the surface even and smooth(without using extra cement) as on walls, complete all as specified and directed by Engr-in-Charge. Notes :- Plaster shall be carried out upto any height in patches and contractor shall have no claim for height and scaffolding what so ever is required to complete the work.
M&L for preparation of new plastered surfaces of wall or concrete surfaces and applying two coats of cement based paint over one coat of primer, complete all as specified and directed by Engr-in-Charge.
Preparation of new plastered wall surfaces and applying two coat of white wash, complete all as specified and directed by Engr-in-Charge.
M & L two coat of cement base paint over a coat of alkali resistant priming paint over old plastered surfaces of wall including preparing surfaces after complete removal of existing treatment upto 5-10 m height from ground level and at all locations as directed including , scaffolding, cleaning and curing etc, complete all as specified and directed by Engr-in-Charge.
M&L for brushing neat cement slurry with 3.00kg of cement per sq.metre , complete all as specified and directed by Engr-in-Charge.
Precast reinforced cement concrete, (Nominal mix), Type B-1, 1:2:4 (using 20mm graded crushed stone aggregates) as in cover slab, manhole cover, shelves and similar articles with plain face, set and jointed in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge. (Note : Reinforcement shall be measured and paid separately)
RCC M-25 as in walls, basement wall,retaining wall of any thickness above top of footings incl attached pilasters & buttresses, complete all as specified and directed by Engr-in-Charge. Note : Reinforcement shall be measured and paid separately.
Form work to faces of walls, retaining walls, abutments, parapets & staircase railing and similar work with rough finished, complete all as specified and directed by Engr-in-Charge.
TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and directed by Engr-in-Charge.
TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and directed by Engr-in-Charge.
Dismantling of RCC post or struts of any section embedded in concrete or brick work,masonary etc., including taking out embedded portion and making good disturbed ground and its removal to store yard , complete all as specified and directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided ( FI, Angle posts, Round bars or TMT bars along chain link mesh etc. ) incl. its removal to store yard , complete all as specified and directed by Engr-in-Charge.
Dismantling fencing wire mesh, any type ( chain link mesh and barbed wire mesh ) incl. its removal to store yard , complete all as specified and directed by Engr-in-Charge.
Excavation in post holes (or similar holes) each n. exc 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not. exceeding 25 cm, watering and removing surplus soil to a distance not exc 50 m and making good surfaces in any type of soil , complete all as specified and directed by Engr-in-Charge.
Mild steel work for posts and struts in fencing includings cutting tops to shaps as directed, drilling holes, notching for wire etc: flat iron fillets (For securing wire mesh etc) incl all necessary drilling bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 , complete all as specified and directed by Engr-in-Charge.
M &L for cement concrete type B2 1:2:4 using 40mm graded stone aggregate in foundations, filling ,mass concrete and fdn of fencing posts etc, complete all as specified and directed by Engr-in-Charge.
PCC 1:3:6, type C-2, using 40 mm graded crushed stone aggregate as in fdns, filling, mass concrete and for embedding chain link mesh bottom , complete all as specified and directed by Engr-in-Charge.
Supply only Chain Link MS galvanised fencing ( Dia of wire 4mm) having mesh size of 50x50mm centre to centre , complete all as specified and directed by Engr-in-Charge.
Fixing only mild steel galvanized wire chain link fencing mesh of any size to any type of standard rails, straining bolts, including provision of binding wire , complete all as specified and directed by Engr-in-Charge.
Mild steel screw bolts ( Machine made ) 5 to 10mm dia of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends each screwed end to fitted with washers and one hexagonal or square nuts exc 5cm but not exc 10cm long fixed , complete all as specified and directed by Engr-in-Charge.
Galvanized, two strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire staples or steel pins etc , complete all as specified and directed by Engr-in-Charge. (Each line to be measured separately).
Mild Steel TMT bars 10 mm dia and over cut to length bent to shape required including cranking, bending, hooking for columns and binding with steel wire (annealed) not less than 0.9 mm dia or securing clips ( for chain link fencing ) , complete all as specified and directed by Engr-in-Charge.
Restraining and re-securing existing barbed wire of any description including making good staples , complete all as specified and directed by Engr-in-Charge.
Framed work such as grills, gates etc with ends of bars, shouldered or riveted or forged into spikes, framed guard bars, barred iron doors , ladders, framed balusteres: Walk ways, railing; framework of wateretank and similar work conforming to Fe 290 Gde E -165 , complete all as specified and directed by Engr-in-Charge.
Preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
Preparation of new steel surfaces not exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
S & F in repairs concentrina coil galvanised 60 cm dia ( spacing of coil wire @ 20cm c/c ) incl securing point in crossing and provn of galvanised mild steel wire staple or steel pin , complete all as specified and directed by Engr-in-Charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering , complete all as specified and directed by Engr-in-Charge.
M&L prepainted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of path/hardstanding, complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B-1, 75 mm thick using 20mm graded stone aggregate as in flooring finishing even and smooth without using extra cement , complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded aggregate) as in kerbs or mud stops,rounded or chemfered on edges, complete all as specified and directed by Engr-in-Charge.
Machine pressed precast concrete interlocking paver blocks any shape and size confirming to IS15658-2006 of 60 mm thick (M-35 Grade) with grey cement and no pigment , complete all as specified and directed by Engr-in-Charge.
Chequered cement concrete coloured tiles 30cmx30cmx25mm thick set over & including 20 mm thick screed in cement mortar (1:6) with neat cement and pointed in grey cement mixed with pigment to match the shade of tiles , complete all as specified and directed by Engr-in-Charge.
Fine sand filling under floor in layers not exceeding 25cm each layer including watering and well ramming , complete all as specified and directed by Engr-in-Charge.
M&L precast cement concrete jallies 25mm thick (measured solid set in cement mortar 1:4 incl all moulding and necessry form work, complete all as specified and directed by Engr-in-Charge.
M&L prepainted aluminium zink coating GI based plain steel sheet 0.50mm thick of colour having tensile strength 550 mpa in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge
E/M PORTION Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixture such as switches ceiling rose;holders; regulators, socket , ceiling fittings, bulk head fittings, tube light fittings etc removing material to store for keeping in safe custody for reuse or disposal by credit and marking good to disturbed surfaces of walls floors etc , complete all as specified and directed by Engr-in-Charge.
S&F in replacement sub main wiring with copper conductor cable (2 runs of cable) multistaranded FRLSH1.5 Sqmm PVC ISI marked with all insulated unsheathed in and including in existing surface/recessed/PVC conduit pipe 20/25mm dia medium grade fittings including 1.5 Sqmm copper conductor cable PVC insulated unsheathed multithreaded FRLSH using as continues earth wire connected to common earth and earth dolly , complete all as specified and directed by Engr-in-Charge.
S&F Sub main wiring with copper conductor cable (2 runs of cable) multistaranded FRLSH 2.5 Sqmm PVC ISI marked with all insulated unsheathed in and including PVC concealed conduit 25mm dia medium grade fittings including 2.5 Sqmm copper conductor cable PVC insulated unsheathed multithreaded FRLSH using as continues earth wire connected to common earth and earth dolly , complete all as specified and directed by Engr-in-Charge.
S&F Sub main wiring with copper conductor cable (2 runs of cable) multistaranded FRLSH 6.0 Sqmm PVC ISI marked with all insulated unsheathed in and including PVC concealed conduit 25mm dia medium grade fittings including 6.0 Sqmm copper conductor cable PVC insulated unsheathed multithreaded FRLSH using as continues earth wire connected to common earth and earth dolly , complete all as specified and directed by Engr-in-Charge.
S&F switch socket combination 2 in1 , 6 pin, 6 and 16 amp flush type, complete all as specified and directed by Engr-in-Charge.
S&F switch socket combination 2 in1 , 5 pin, 6 amp flush type , complete all as specified and directed by Engr-in-Charge.
S& F surface mounting plastic box 3 module size (11.7x8.9) cm , complete all as specified and directed by Engr-in-Charge.
S& F surface mounting plastic box 4 module size (15X9) cm , complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings , complete all as specified and directed by Engr-in-Charge. Make: Havells/Phillips/Bajaj
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size , complete all as specified and directed by Engr-in-Charge. Make: Havells/Phillips/Bajaj
Supply and fixing in replacement Intelligent, modular High Efficacy LED lights fitting 34W, 220V,AC 2x2 luminaire with integrated PIR Sensor which offersautonomous operation and provides soft-light and glare free symmetrical illuminationsuitable forArmstrong/Grid ceiling. THD<10% is suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size , complete all as specified and directed by Engr-in-Charge. Make: Havells Model No : VENUSNEOOHE2X2R34WLED830PIRSENSOR
Supply and fixing in replacement LED luminaire 600 mm x 300 mm, 30 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size , complete all as specified and directed by Engr-in-Charge. Make:-Phillips typeRC308B LED30S-6500 G5 L3W12 PSU OD /Havells/Bajaj
Supply and fixing in replacement round shape LED luminaire 15 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size , complete all as specified and directed by Engr-in-Charge. Make: Havells/Phillips/Bajaj
S&F Sheet metal enclosure factory made for DBs Triple pole and neutral single door 415 volts 16 way ,suitable for MCCBs and fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing, and commissioning and making good of wall, surfaces , complete all as specified and directed by Engr-in-Charge.
S&F Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 8 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces , complete all as specified and directed by Engr-in-Charge. Make:-Havells/Legrand/Schenider
S&F Sheet metal enclosure factory made for DBs single pole and neutral single door 240 volts 12 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing, and commissioning and making good of wall, surfaces , complete all as specified and directed by Engr-in-Charge. Make:-Havells/Legrand/Schenider
S&F RCBO double pole, 240 Volts , 50 Hz 10 Ka, 40 Amps, 30mA , complete all as specified and directed by Engr-in-Charge. Make:-Havells/Legrand/Schenider
S&F MCB single pole and neutral, 240 Volts , 50 Hz 10 Ka, 40 to 63 Amps, 30mA , complete all as specified and directed by Engr-in-Charge. Make:-Havells/Legrand/Schenider
S&F MCB single pole 240 Volts , 6 to 20 Amps , complete all as specified and directed by Engr-in-Charge. Make : avells/Legrand/Schenider
S&F MCB TPN, 240 Volts , 10 Ka, 40 to 100 Amps, complete all as specified and directed by Engr-in-Charge. Make:-Havells/Legrand/Schenider
S&F Plug top with indicator 16 amp , 3 pin, ISI Marked complete all as specified and directed by Engr-in-Charge. Make:-Havells/Anchor/legrand
Taking down ceiling fan sealing cable end etc and shifting to store complete and rehanging the same after overhauling and with white synthetic enamel paint(two coat) with the help of spray gun and connecting with three core flexible copper conductor cable 0.75 sq mm complete all as specified and directed by Engr-in-Charge.
All as per ser item No 79 here- in- before, but for exhaust/wall fans of any size/make, complete all as specified and directed by Engr-in-Charge.
S& F in repair PVC connection 15 mm size with PTMT nuts of length 300 mm , complete all as specified and directed by Engr-in-Charge.
Checking,servicing, oiling and greasing of fan of any size/type by using appropriate grade of oil /grease and replacing defective parts such as bush, bearing, split pin, rubber bush, hanging clamp and capacitor etc including cleaning, complete all as specified and directed by Engr-in-Charge. (Note-Parts/components will be measured and paid seperately under their respective items)
Rewinding of celling fan 1200/1400mm sweep, AC, 230 volts single phase with super enamelled copper winding wire of appropriate size including packing, insulating material, soldering, varnishing, reassembling and testing as required, making functional, complete all as specified and directed by Engr-in-Charge.
Nuts, bolts and washers of appropriate size for hanging of celling fan, complete all as specified and directed by Engr-in-Charge.
Top / botton canopy of required size with tightening screws, complete all as specified and directed by Engr-in-Charge.
Bearing of celling fans for 1200/1400mm sweep suitable for different makes /type of fans, complete all as specified and directed by Engr-in-Charge. Make :- NBC, SKF,
Ball bearing suitable for exhaust fan 300mmsweep of different make, complete all as specified and directed by Engr-in-Charge.
Split pins of galvanished iron 1/8" dia, 2" length, complete all as specified and directed by Engr-in-Charge.
Rewinding of exhaust fan 300mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , reassembling , testing and making functional, complete all as specified and directed by Engr-in-Charge.
Rewinding of exhaust fan 450mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , reassembling , testing and making functional, complete all as specified and directed by Engr-in-Charge.
Rewinding of wall mounting fan 400mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , reassembling , testing and making functional, complete all as specified and directed by Engr-in-Charge.
Condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD, complete all as specified and directed by Engr-in-Charge..
All as per ser item No 92 here- in- before, but for 3.15 MFD , complete all as specified and directed by Engr-in-Charge.
All as per ser item No 92 here- in- before but 4 MFD for Exhaust Fan, complete all as specified and directed by Engr-in-Charge.
Dismantling of geyser from its location, 25/35/50Ltrs capacity for checking, test and making leak proof by means of welding of tanks, replacement of parts, under item here in after and to make serviceable and re-assembling, including packing of glass wool properly, replacement of worn out nut, bolts, washers, screws as reqd, applying one coat of synthetic enamel paint including testing and re installation/ refixing, complete all as specified and as directed . Note : New items provided shall be meaured and paid under relevent item of Sch.
Apparatus plate heavy duty, rubber gasket suitable for 25/35/50 Ltr of geyser, complete all as specified and directed by Engr-in-Charge.
Geyser element 1.5 KW, ISI Marked, complete all as specified and directed by Engr-in-Charge.
Geyser element 2 KW, ISI Marked, complete all as specified and directed by Engr-in-Charge.
Geyser element 3 KW, ISI Marked , complete all as specified and directed by Engr-in-Charge.
Geyser thermostate switch ISI Marked, complete all as specified and directed by Engr-in-Charge.
Geyser indicator lamp red colour for heating and green colour for cut off, complete all as specified and directed by Engr-in-Charge.
Geyser Non return valve 15mm dia pipe CP brass, ISI marked, complete all as specified and directed by Engr-in-Charge.
Geyser Pressure release valve ISI marked, complete all as specified and directed by Engr-in-Charge.
Descaling of gyser tanks of capacity 25/35/50 Ltrs by using suitable powder/ chemical, up to the satisfication of engineer in charge, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH , complete all as specified and directed by Engr-in-Charge.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp AC 240Volts 'C' series incl dismantling old one, complete all as specified and directed by Engr-in-Charge.
S&F in repairs metal clad plug and socket for AC plug and geysers , complete all as specified and directed by Engr-in-Charge.
S&F in repairs LED building security light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant completewith driver, lamp, clamps, suitable bracket with impact and corrosion resitant including thermal management in multiple optics complete with IP 65/66 protection , complete all as specified and directed by Engr-in-Charge.
S&F radiant 07W LED Step light environmental friendly, new generation, energy saving, decorative rectangularshaped IP66 LED step light for wall recessed application , complete all as specified and directed by Engr-in-Charge. Make : Havells Model No RADIANTFTR07WLED830PSYMTOPC
VARDHMAN INTERNATIONAL (BID ID -3321183)
VIRINDER SINGH (BID ID -3313775)
RAMAN KUMAR (BID ID -3321440)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .