Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹30.8 L+₹2.7 L (9.50%)Rejected-Finance VILL JASSAI DISTRICT BARMER RAJ 344001 | JASSAI | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Highest | |
| 3 | L3₹32.8 L+₹4.7 L (16.8%)Rejected-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Highest | |
| 4 | L4₹33.0 L+₹4.9 L (17.5%)Rejected-Finance | L4 | Rejected-Finance Highest | |
| 5 | L5₹34.6 L+₹6.5 L (23.3%)Rejected-Finance NEAR RAILWAY STATION UTARLAI BARMER RAJASTHAN PIN 344001 | BARMER | RAJASTHAN | 344001 | L5 | Rejected-Finance Highest |
Tender Value
₹35.9 L
EMD Value
₹71,700
Closing Date
7 Jun 2022, 6:00 pmClosed
GE ARMY BARMER
Military Engineer Services, Jalipa Military Station, Garrison Engineer (Army), Barmer, PIN 344001
PROVN OF 08 ORDERLY NCOS ROOM ALONGWITH TOILET AND BATHROOM AND CULVERT ON RAINY SEASONAL NALLA AT JASAI MIL STN UNDER GE ARMY BARMER
2022_MES_521095_1
8616/E8
Open Tender
Civil Works
Works
180 days
GE ARMY BARMER
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹71,700
2 Aug 2022
30 Apr 2022
9 Jun 2022
30 Apr 2022
7 Jun 2022
17 May 2022
Amount
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in soft/loose soil.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out hard/dense soil.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out soft/disintegrated rock.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out hard rock.
M&L for cement concrete Type D2 1:4:8 (40 mm graded aggregate) in foundations, filling and mass-concrete.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; exceeding 200m thick (Horizontal or sloping) flat rough finished surfaces of concrete complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, rough finished surfaces of concrete complete all as specified and directed.
Formwork to Formwork to chullah hoods, chajjas, troughs and similar items including edges rough finished surfaces of concrete complete all as specified and directed.
M & L for RCC design mix M-25 (20 mm graded aggregates) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC design mix M-25 (20 mm graded aggregates) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like complete all as specified and directed.
M&L for RCC design mix M-25 (20 mm graded aggregates) in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC design mix M-25 (20 mm graded aggregates) in chajjas complete all as specified and directed.
M&L for RCC design mix M-25 (20 mm graded aggregates) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT steel bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No. 18 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for Brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
M&L for Brickwork with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4) complete all as specified and directed.
M&L for rendering 10mm thick plaster in CM (1:6) on faces of brick work or concrete surfaces, finished with 1mm thick sagol finish complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls, and applying three coats of white wash complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls, and applying two coats of oil emulsion distempering over a coat of interior wall primer complete all as specified and directed.
M&L for rendering 5mm thick plaster in CM (1:3) on faces of brick work or concrete on surfaces of ceiling, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces of ceiling, and applying three coats of white wash complete all as specified and directed.
M&L for rendering 15mm (in two layers 10mm+5mm) thick plaster in CM (1:4) on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. (Note : Water proofing compound shall be measured and paid separately.)
M&L for rendering 10mm thick CM (1:3) on roof slab top, mixed with water proofing liquid finished even and fair without using extra cement complete all as specified. Note: Water Proofing liquid shall be measured and paid separately.
M&L cleaning the newly plastered surfaces of concrete ( roof etc) with wire brushes and applying water proofing treatment as under :- i) Apply one coat of oil bound bituminous primer @ 0.40 kg/Sqm. ii) Providing and laying 3 mm thick APP modified water proofing membrane weighing not less than 3.5 Kg / Sqm reinforced with non woven polyester mat weighing not less than 160 gm/Sqm all as specified procured from any one of the approved manufacturer's iii) Apply one coat of solar reflective bituminous aluminium paint @ 0.15 Kg/Sqm over membrane over non assesble roof surfaces complete all as per manufacturer's instructions and as directed .
M&L for preparation of new plastered surfaces of walls and applying two coat of cement based paint over a coat of primer complete all as specified and directed.
Supply only Liquid water proofing compound.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated soil material exc. 1.5km and n exc 5.0km depositing where directed at a level n exc. 1.5 m above the starting point.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering complete all as specified and as directed.
M&L for Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and as directed .
M&L for Hardcore of broken stone or boulders of gauge n exc. 63 mm,deposited,spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for Glazed ceramic tiles of size 350mm x 250mm x 7mm/ 450mm x 350mm x 7mm thick (coloured) of superior quality fixed on vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry over 10mm thick backing coat in CM (1:4) and pointed in coloured cement to match complete all as specified and directed.
M&L for non skid ceramic tiles of size 7 to 8mm thick (coloured) (Square/rectangular) area of each tile exc 0.18 but n exc 0.38 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM (1:6) complete all as specified and directed.
All as per Sl item No 38 above but in skirting over 10mm thick backing coat in CM (1:4) complete all as specified and directed.
M&L for non skid ceramic tiles of size 7 to 8mm thick (coloured) (Square/rectangular) area of each tile exc 0.06 but n exc 0.11 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM (1:6) complete all as specified and directed.
S&F for vitreous china wash down water closet pan and trap (pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe with and including plastic water closet seat, white closed pattern with flat bottom, cover and mild steel hinges device complete all as specified.
S&F for Vitreous China Urinal, Half stall type, white, complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement, including waste pipe complete all as specified and as directed.
S&F for wash hand basins, vitreous china,of size 550x400mm (flat back, or angle back type) including cutting for and pinning in ends of brackets or erecting stand inclusive of fixing of supply and waste pipe etc complete all as specified and as directed.
S&F for vitreous china squatting Pan “Orissa” Pattern, of size 580mm x 440mm white with integral foot rests and trap (excluding flushing cistern and flush pipe) including trap and provn of cement concrete bedding complete as fixed complete all as specified.
S&F fpr 15mm bore fancy type, pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F for 15mm bore bib taps fancy type, cast copper alloy chromium plated, screwed down, and screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F for 15mm bore, 450mm long, PVC connections with brass unions internally threaded both ends complete fixed to iron pipe at both ends as fixed in repairs complete all as specified and as directed..
S&F for 15mm bore stop/angle valves, cast copper alloy, chromium plated fancy type screwed down, screwed both ends for iron pipe or for union complete all as specified and directed.
S&F for PVC valveless flushing cistern, low level white with inlet ball valve float and handle including brackets complete capacity of flush 10 ltrs complete all as specified and as directed.
S&F for new rotational moulded polythylene water storage tank (cylindrical/vertical with closte top) hoisted and fixed in position all as specified in SSR Part-I including providing and fixing ball brass valve high pressure with polythene float and fly nut, 20mm bore complete for following capacity of tanks :- 500ltrs
S&F for 20mm bore GI tubing medium grade with all fittings & fixed complete to walls /ceiling or laid in floors all as specified & as directed.
S&F for 25mm bore GI tubing medium grade with all fittings & fixed complete to walls /ceiling or laid in floors all as specified & as directed.
Supplying and laying of 16mm bore of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Cutting chases in brick wall, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth all as specified and as directed.
S&F for PVC (SWR) floor trap plain with grating including jointing with solvent cement of 75 mm dia complete all as specified and directed.
S&F for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F for Swivel shower of PTMT any colour for fixing with 15mm pipe (Minimum weight 40gms) complete all as specified and as directed.
S&F for Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) complete all as specified and as directed.
S&F for Toilet paper holder with flat recessed type stainless steel fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F for Gun metal gate valves 20 mm with iron wheel head screwd both ends for iron pipes complete all as specified and directed.
S&F for Gun metal gate valves 25mm with iron wheel head screwd both ends for iron pipes complete all as specified and directed.
S&F for 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall / floor complete all as specified and as directed.
S&F for 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall / floor complete all as specified and as directed.
S&F for 110mm bore PVC (SWR) bend any radius complete all as specified and directed.
S&F for 75mm bore PVC (SWR) bend any radius complete all as specified and directed.
S&F for 75mm bore PVC (SWR) bend with access door any radius complete all as specified and directed.
S&F for 110mm bore PVC (SWR) bend with access doorany radius complete all as specified and directed.
S&F for 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F for 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
M&L for 150x100mm size salt-glazed stone ware gully traps, square or round mouthed, type `P' complete all as specified and as directed.
S&F for110mm boe PVC (SWR) vent cowl complete all as specified and as directed.
S&F for PVC door frames of sizes 50x47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube in opening of suitable size complete all as specified and as directed.
S&F for Factory made solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail and bottom rail in either side and as gap insert for top rail and bottom rail pannelling of plain colour PVC sheet to be filled in the MS welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together wiht solvent and fixing in the frame at site as per specification and drawing complete all as specified and as directed.
S&F for steel ventilator fixed type with glazing bar complete all as specified and as directed
S&F for Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S&F for Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed.
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 all as specified and as directed.
M&L for sheet glass 4.0 mm thick ordinary quality and glazing with oil putty, in squares n. exc 0.5 Sq.M in each pane complete all as specified and as directed.
S&F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples complete all as specified and as directed. and directed.
M&L for Pressed steel frames of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed.
M&L for Pressed steel frames of size 165 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed.
S&F for 2nd class HW shutters 35mm thick, plain framed paneled shutter factory made (two panel) with lock rail & panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 complete all as specified and as directed.
S&F for 2nd class H.W. glazed & skeleton shutter 35mm thick factory made open rebated & prepared to receive glass gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass,gauge etc size of members of shutter as specified in SSR part-I , section 8, clause 8.24 (a) complete all as specified and as directed.
M&L for preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise, described, over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of New or previously untreated steel or iron surfaces of any description, not otherwise, described, over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F for 100mm long butt hinges medium weight cold rolled mild steel complete all as specified and as directed.
S&F for 150 mm long Aluminium anodizes barrel tower bolts of extruded section complete all as specified and as directed.
S&F for 150 mm size aluminium anodized handle complete all as specified and as directed.
M&L for 300 mm long aluminium alloy anodized sliding door bolts with Hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F for aluminium floor door stoppers double legged length 140mm with hard drawn steel spring fitted in floor complete all as specified and as directed.
S&F for mild steel ordinary rat tail rod pattern spring 300mm size including roller & roller plate and incl welding complete all as specified and as directed.
S&F for Drapory rod 25mm dia alluminium alloy powder coated fixed with fancy type matching pair of bracket not less than 75 grams each fixed with screw complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection including making joint at every 3 mtr interval and at corner and filled with mixture of bitumen and sand and finished even and fair and laid in alternate bays complete all as specified and as directed.
M&L machine pressed precast cement conctete interlocking paver block Rubber Moulded of any shape and size confirming to IS 15658-2006, M-35 Grade, 60 mm thick, with grey cement and pigments, over and including sand cushioning of 40mm thick complete all as specified and as directed.
M&L Cement concrete 100mm th type B-2, 1:2:4 (40mm graded aggregate).
M&L Pre-cast cement C-1 1:3:6 (20mm Agg ) CM 1:6 concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete.
Removing excavated soil material soil exc 50m and n exc 250m and depositing where directed at level n.exc 1.5m above starting point complete all as specifed and directed
M&L for 150 mm dia RCC Hume pipe, class NP-2 ,ISI marked laid and jointed with collar in cement motar (1:1) complete including dismantling the existing drain/sewage pipe all as specified .
M&L for concrete bed in cement concrete 1:4:8 type D-2 (40 mm graded stone aggregate )to drain pipes including packing under and haunching against the sides of pipes after they are tested for 150mm dia SWG/NP-2, pipe all as complete.
M&L for Construction of Soakage Pit for 50 User and Excavation is on any type of soil/Rock as per TD Drawing CEJZ/STR/STD/16/2016 DTED 31 March 2015 set No 1/1. Note : Depth of freeboard (Bottom level of RCC slab & Top level of Fluid) shall be (0.50+0.15)m or depth of Outlet invert level Of Septic Tank+0.20m from GL, which ever is more irrespective of what ever is shown on drawings.
M&L for Construction of Septic Tank for 50 User and Excavation is on any type of soil/Rock as per TD Drawing CEJZ/STR/STD/12/2016 DTED 31 March 2015 set No 1/1 and 1/2. Note : Depth of freeboard (Bottom levet of RCC slab & Top level of Fluid) shall be 0.75m or depth of last man hole invert level+0.20m from GL, which ever is more irrespective of what ever is shown on drawings.
M&L for walling of random rubble brought up to course, coursed, well bonded, bedded and solidly hearted, built in cement mortar in 1:4 complete all as specified and directed.
Excavating over areas, n exc 1.5m deep and getting out soft/loose soil.
Excavating over areas, n exc 1.5m deep and getting out in hard/dense soil.
Excavating over areas, n exc 1.5m deep and getting out soft/disintegrated rock.
Excavating over areas,n exc 1.5m & and getting out hard rock.
M&L for forming embankment including raising (or lowering) earth, spreading in layers not exc, 30cm thick, watering remmining/rolling and finishing to reqd size, shape etc, not exc 1.5mtr height from base all as specified and directed
M&L for preparation of new or previously untreated surfaces of any description wood, steel, iron, concrete, brick, stone, etc exceeding 10cm in width or girth and applying two coats of black bituminous paint complete all as specified and directed
M&L Providing reinforced cement concrete design mix M-30 as in roof slabs supported on walls surfaces of concreate all as specified and directed.
M&L for 75mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring/wearing coarse complete all as specified and directed.
M&L for boulder pitching, laid dry, hand packed tightly and grouted with cement and sand mortar 1:6 complete all as specified and directed.
M&L for RCC (Nominal mix) type B1 1:2:4 (20 mm graded aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Extra over lime or sand stone walling for hammer dressing with maximum depression 20mm on face from straight edge held against the dressed surface n exc to face stones and dressing or face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed
M&L for 75mm thick Cement concrete type B1 1:4:8 (20mm graded aggregate) as in flooring/wearing coarse complete all as specified and directed
M&L Point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor, nominal cross-sectional area is 1.5 sq mm , single core, PVC insulated and sheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including drawn through and including in PVC rigid conduit with all accessories complete concealed in wall/roof/floor etc, ISI marked with1.6mm thick mild steel/prestressed steel sunken/concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light/ bell point controlled by one, one way switch including for making good to disturbed surfaces of walls, floors etc. complete all as specified and directed . Note :- surface conduit shall be laid in ceiling portion only. One light point controlled by one switch 5 Amps one way.
All as per serial item No 116 above but for One fan point/exhaust fan point controlled by one , oneway switch 5Amps.
All as per serial item No 116 above but for 5 Amps socket point on independent board.
All as per serial item No 116 above but for 5 Amps socket on same board with other switches.
All as per serial item No 116 above but for 15 Amps socket point on independent board with 2.5 Sqmm PVC insulated FRLS multi-stranded copper conductor with 2.5 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire,complete all as specified and as directed.
S&F switch piano 5 Amp flush type single pole one way with ISI marked,complete all as specified and as directed.
S&F socket outlets 5 Amps 2-in-1, 3 pin 230 V AC flush type, complete all as specified and as directed.
S&F of ceiling rose, surface bakelite, 65 x 50 mm, three terminals, 230 Volts complete all as specified and as directed.
S&F socket outlet, multipurpose, 2 in 1, 5 and 15 Amps, flush type, universal ,230 Volts controlled by one switch complete all as specified and as directed.
S&F switch piano flush type 15 Amps single pole one way with ISI marked complete all as specified and as directed.
S&F of lamp Holder, insulated body, B22 base suitable for LED bulb & CFL Bulb, 230 Volts complete all as specified and as directed.
S&F of LED Lamp 09 Watt 230 Volts complete all as specified and as directed.
S&F Electronic fan regulator, stepped type, 100 W, AC, 230 Volts, fixed on existing laminated sheet complete all as specified and as directed.
S&F LED Tube light fitting 20W with frame ( integrated driver), 6500K colour temp, decorative type with all accessories internally pre wired and connectiong up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed Make : Crompton /Philips / Wipro.
M&L for MCB DB SPN 8 way double door concealed in wall IP 43 protection with MCB SPN ‘C’ Curve type 40 amps 01 No and MCB SP ‘C’ Curve type 6 to 32 amps 06 Nos including necessary connection lugging with copper lugs pin/Ring type making good disturbed surfaces to match with existing surface / wall.
S & F in repair LED light of 25W pressure die caast aluminium housing with heat resisitant toughened glass & IP65 protection.CAT REF No:- LSTP-25-CDL of CG or Equivalentor Equivalent make of Philips/GE/havelss
S&F for ceiling fan of size 1200 mm sweep AC, 230 Volts complete all as specified and as directed.
S&F for exhaust fan 250 mm sweep including testing complete all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrodes 60cm×60cm× 6mm thick thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing lead wire 4.0 mm by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erection of poles, struts/stays, leveling of yard, taking out existing pipe etc not exceeding 10 M² on plan and not exceeding 1.5 m in depth and getting out in Soft/loose soil.
Removing of excavated soil not exc. 50 M and depositing where directed at a level n. exc 1.5 M above the starting points all as specified and directed
Material and labour for sand cushioning to underground cable screened un-washed river sand and punning for cushioning to cable all as directed.
Material and labour for stone slab(patti), roughly hammer dressed stone, 40 to 50 mm thick, 25 to 30 cm wide and not less than 60 cm long laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over underground cables for protection.
M&L for Earthing complete with galvanized steel earth plate electrodes 60cm×60cm× 6mm thick thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site.
S & F tubes, medium grade (ISI marked), galvanized iron with and including all fitting (ISI marked) laid in trenches/fixed to wall/fixed on pillars etc complete all as specified and as directed of following sizes :- (a) 20 mm (3/4”) dia.
All as per Srl Item No 141 above but 25 mm (1”) dia.
Supply and fixing gun metal gate valves with iron wheel head, screwed both ends for jointing iron pipe, non rising forged brass spindle class I complete all as specified and as directed suitable for following sizes (Make : Lakshmi/Zolota) (a) 20 mm (3/4”) dia pipe.
All as per Srl Item No 143 above but 25 mm (1”) dia pipe.
M& L for Construction of brick masonry valve Pit of size 50x 50 x 75 cm (internal dimension) including MS sheet cover fabricated from 3 mm thick MS sheet and frame angle iron 40 mm x 40 mm x 6 mm with fixing arrangement, hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer including necessary earth work 150 mm thick PCC 1:4:8 type P-2 using 40 mm stone aggregate as in foundation brick work in CM 1:4 all as directed and indicated by Engr-in-Charge.
M&L for making connection of GI pipe line from existing any size GI/CI/DI pipe line by cutting/ tapping/ drilling of bore of suitable size including clamps, bolts etc. and checking of flow complete all as directed and specified.
m/s jogaram sujaram
National Rewinding Works
m/s sai construction company,bijarar
M/S TANUSHREE CONSTRUCTION COMPANY
M/s Malinath Electricals
Devi Engineeing
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .