| 1 | L1₹14.7 LAccepted-AOC R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC DUE TO BEING L1 AND REASONABLE | |
| 2 | L2₹27.7 L+₹10.3 L (59.5%)Rejected-Finance | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 3 | L3₹20.2 L+₹2.8 L (16.0%)Rejected-Finance | L3 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
7 Feb 2023, 6:00 pmClosed
GE (SOUTH) AKHNOOR
GE (SOUTH) AKHNOOR C/O 56APO
REPAIR TO CEILING FAN , EXHAUST FAN ,GEYSER, ELECTRIC METERS AND CONNECTED WORKS IN OTM AND MD ACCN AND REPAIR/ REPLACEMENT OF INTERNAL WIRING, FITTINGS , FIXTURES AND CONNECTED ITEMS IN OTM ACCN AT AKHNOOR WITHIN AOR OF AGE E/M UNDER GE (SOUTH) AK
2023_MES_574070_1
GES/AKH-30/2022-23
Open Tender
Civil Works
Item Rate
240 days
GE (SOUTH) AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE WITH CATEGORY b(i)
9 documents required · 9 mandatory
₹500
GE (SOUTH) AKHNOOR
₹70,000
20 Feb 2023
10 Jan 2023
9 Feb 2023
10 Jan 2023
7 Feb 2023
24 Jan 2023
Amount
M & L for disconnecting electric supply, taking down fan, cealing cable ends, dismantling blades carefully after unscrewing nuts and bolts of ceiling fan of any make from existing position and bringing to AGE E/M store yard for repairs, overhauling, oiling, greasing and cleaning all dusts all as specified and as directed by EIC. complete all as specified and as directed by EIC. Note : Store like ball bearing, gun metal bush, capacitors and canopy required for repair/over hauling shall be measured and paid separately under relevant item of this schedule.
M & L for painting of ceiling fans (1200 mm/ 1400 mm) complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts including writing of MES Nos in black paint all as specified and as directed by EIC.
Dismantling of worn out/burnt out ceiling fans 1200 mm sweep and re-winding the ceiling fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut , complete all as specified and directed by Engineer in charge
Description all as per serial item No 03 here in before but for Ceiling fans of 1400 mm sweep.
Supply and fixing in replacement of ball bearing suitable for ceiling fans of any make, type and size. Make: - SKF, NBC, and TATA
Supply and fixing in replacement of bush made out of Gun metal suitable for ceiling fans of any make, type and size.
Supply and fixing in replacement of capacitors 2.5 MFD suitable for ceiling fans of any make, type and size. Make: - Usha, Universal, Tipcon, Epcos.
Supply and fixing in replacement of canopy suitable for ceiling fans of any make, type and size. Make: - Usha/Khaitan/ Bajaj.
Suply and replacement of down rod suitable for ceiling fans of any type and size. Make Usha or equivalent.
Supply and fixing in replacement of clamp with nuts & bolts & locking pin suitable for ceiling fans of any make, type and size. Make: - Usha/Khaitan/ Bajaj.
Supply and fixing in replacement rubber reels suitable for ceiling fans of any make, type and size. Make: - Usha, Universal, Tipcon, Epcos.
Supply and fixing in replacement of aluminium blade for ceiling fan of 1200 mm sweep complet all as specified and directed by Engr-in-Charge.
M & L for hanging the repaired ceiling fan (dismantling as per item No. 1 above) and connecting up including provision of cables from ceiling rose or connector to fan all as specified and as directed by EIC.
S & F 0-4 step-1, electronic fan regulator flush type on the existing phenolic laminated sheet including taking down the old unserviceable regulator all as specified and as directed by EIC.
Taking down carefully existing exhaust fans of any make and sizes from wall , cleaning externally, opening for examination and overhauling complete by opening , cleaning of bearing ,stator ,rotor winding , providing new fresh clean proper grade lubricants oil/grease and re assembling after replacement of split/safety pins, MS nuts and bolts , including replacement of old existing flexible cord connected from ceiling rose to fan including re-writing MES/ SL No. with black synthetic enamel paint , refixing the same in position complete all as specified and directed by Engineer in charge. Note:-Store like ball bearing, gun metal bush and capacitors required for repair/overhauling shall be measured and paid separately under relevant item of this schedule complete all as specified and directed by Engr-in-Charge.
Dismantling of worn out/burnt out Exhaust fans 275 mm to 375 mm sweep and re-winding the exhaust fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, rusted nut ,bolt and washer complete all as specified and directed by Engineer in charge.
Description all as per serial item No 16 here in before but for Exhaust fans of size above 375 mm but up to 450 mm sweep complet all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of ball bearing suitable for exhaust fans of size from 275 mm to 375 mm sweep. Make: - SKF, NBC, and TATA.
Supply and fixing in replacement of ball bearing suitable for exhaust fans of size above 375 mm to 475 mm sweep. Make: - SKF, NBC, and TATA.
Supply and fixing in replacement of capacitors suitable for exhaust fans of size 275 mm to 375 mm sweep. Make: - Usha, Universal, Tipcon, Epcos.
Supply and fixing in replacement of capacitors suitable for exhaust fans of size above 375 mm but up to 475 mm sweep. Make: - Usha, Universal, Tipcon, Epcos.
M & L for painting of Exhaust fans of size 275 mm to 375 mm sweep complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts all as specified and as directed by EIC.
Description all as per serial item No 22 here in before but with grey paint for exhaust fans above of size 375 mm to 450 mm sweep.
Supply and fixing in replacement of louvers shutters complete with nuts, bolts and washers suitable for exhaust fans of size 275 mm to 375 mm sweep complete all as specified and directed by Engineer in charge.
Supply and fixing in replacement of louvers shutters complete with nuts, bolts and washers suitable for exhaust fans of size above 375 mm and up to 450 mm sweep complete all as specified and directed by Engineer in charge.
Supply and fixing in replacement PVC Exhaust fan 250 mm sweep with louvers complete all as specified and directed by Engineer in charge. Make Havells or equivalent in HPL Bajaj Crompton
Supply and fixing in replacement Exhaust fan 300 mm sweep with louvers complete all as specified and directed by Engineer in charge. Make Havells or equivalent in HPL Bajaj Crompton
M&L for making hole on masonary wall/ Wodden Panel of size suitable for exhaust fan complete incl finishing and making good as per existing all as specified and directed by Engineer in charge.
Labour only to find out defects and for testing geysers of any capacity of vertical and horizontal geysers for proper functioning by checking the thermostat, heating elements, indication lamps, cable cords and connections, 15 Amps socket and top, inlet and out let water pipes etc complete all as specified and as directed. Note : If any defects observed during testing shall be repaired in respected item of Sch 'A' which is measured and paid separately and spares required to be changed shall be measured and paid separately complet all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of geyser elements I.5 KW as per existing pattern fitted in the geyser all as specified and directed. Make: Toshiba, Comet, Hot max or as approved by Engr-in-charge
Description all as per item No 30 above but 2.0 KW complete all as specified.
Supply and fix in replacement of lamp indicater red/green all as per site requirement and specified.
S & F PVC connection with PTMT nuts of length 450 mm as inlet for cold water including taking down the old unserviceable PVC connection pipe complete all as specified and as directed by EIC.
S & F PVC connection, spirally reinforced with stainless steel wire inside the pipe for outlet hot water pipe connection, with brass nuts at both ends of length 450 mm including taking down the old unserviceable PVC pipe all as specified and as directed by EIC.
Supply and fixing in replacement of inner tank of 25 ltr capacity of tinned/ copper of approved make all as specified and directed as per site requirement.
Supply and fix in replacement of inner tank of 35 Ltrs capacity geyser of tinned /copper of approved Make all as per site requirement and as directed.
Supply and fix in replacement of inner tank of 50 Ltrs capacity geyser of tinned/ copper of approved Make all as per site requirement and as directed or indicated.
Supply and fix in replacement of glass wool/mineral wool same as (Thermal insulation) for 25 ltrs capacity geyser all as directed.
All as per item No 38 above but for 35 ltr capacity geyser complete all as specified.
All as per item No 38 above but for 50 ltr capacity geyser complete all as specified.
Supply and fix replacement of thermostat (Thermal cut out) suitable for geyser to be repaired as per approved make and capacity 25/50 ltrs complet all as specified and directed by Engr-in-Charge.
Supply and fix replacement of pressure release valve suitable for 25/50 ltrs capacity geyser of approved make and type all as site requirement.
Supply and fix in replacement of 3 core multi strand copper conductor PVC insulated cable 2.5 Sqmm1100 volts grade complete all as specified and directed by Engr-in-Charge.
S & F switch socket combination multi purpose three pin 5/15 amps flush type on new laminated sheet top cover, 3 mm thick including taking down old unserviceable 15 Amps switch socket combination all as specified and as directed by EIC.
S & F 3 pin plug top 15 Amps, 240 volts including taking down old unserviceble 3 pin plug top 15 amps all as specified and as directed by EIC.
Material and labour for painting the geysers of 25 ltr capacity with two coats of synthetic enamel paint white with spray gun including preparation of surfaces area of geyser,filing cavities with filler after cleaning all dust complet all as specified and directed by Engr-in-Charge.
All as per item No 46 above but of 35 ltr capacity geyser complete all as specified.
All as per item No 46 above but of 50 ltr capacity geyser complete all as specified.
Supply and fix in replacement of 15mm dia gun metal stop cock complet all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of 20mm dia gun metal stop complet all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of GI union 15mm complet all as specified and directed by Engr-in-Charge.
All as per item No 51 above but of 20 mm dia complet all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of GI socket 15mm dia complet all as specified and directed by Engr-in-Charge.
All as per item No 53 above but 20mm dia complet all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of GI elbow 15mm dia complet all as specified and directed by Engr-in-Charge.
All as per item No 55 above but 20mm dia complet all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of GI reducing socket 20mmx15mm dia all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of Tee equal 15 mm dia complet all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of GI Nipple 15mm dia, 100 mm long complet all as specified and directed by Engr-in-Charge.
All as per item No 59 above but 20mm dia, 100 mm long complet all as specified and directed by Engr-in-Charge.
Supply and replacement of internal water tubing assembly for 25 Ltr cap geysers including synthetic rubber gasket of suitable size matching with existing holes and tightening all as directed by Engr-in-Charge.
All as per item No 61 above but 35 ltr capacity complete all as specified.
All as per item No 61 above but 50 ltr capacity complete all as specified.
S&F in replacement of Ceiling fan, mettalic, sweep 1200mm, with BLDC Motor, high speed, inclduing necessary fitting/fixtures such as Hook and clamps etc including connectig wire of suitable size and length from ceiling rose to fan connector, having BEE Star Rating- 5 Star, Rated Power Input in Watt 28±10%, Rated Speed in RPM 345±10%, Rated Air Delivery in CuM/ Min- 220 Minimum, Service Value CMM/W 7.85 Minimum No of Speed 5 , Insulation Class- E, Temperature Rise @ Rated Voltage 25 degree Celcius (Max) by winding resistance measurement at an ambient 30 degree Celcius, High Voltage Test Withstands 1.5KV, Insulation resistance Above 2 MΏ, Type of Ball Bearings Single row deep groove ball bearings of 6202 sizes Top & Bottom Cover should be of aluminium, Type of Lubricant Used Lithium Based – Shell Alvania RL3, Material of Blade Aluminium, BEE Certification, Material of Canopies- Polypropylene, complete all as specified and as directed. Make: BAJAJ Model No Energos 28 or Equivalent Makes in Havells / Crompton Greaves/ Usha / Orient Note: Old Ceiling fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt.”
S&F in replacement of Water heater storage type (geyser), wall hanging, capacity 25 Litres, Energy saving high density PUF insulation, BEE rating Five (5) Star, 230 Volts, single-phase, 50 Hz AC, rated power input not less than 1000Watt, complete all as specified. Make: Havells/Bajaj/Jaquar/Racold Note: Old Geyser taken out from the existing place and shall be deposited at Store Yard of MES and shall be the property of Deptt.”
Disconnection the electric connection and taking down old unserviceable electric meter from existing location and deposited in AGE E/M store yard.
S & F Single Phase Electric Meter with LCD display, tamper proof, with accuracy class 1.0 as per IS: 13779, with CT Rating capacity 10-40 Amps having anti tempter feature with transperent pilfer proof meter box complet all as specified and directed by Engr-in-Charge.
M & L for fixing of pvc insulated FRLS cable with multistranded copper conductor 1100 volt grade of size 6 Sqmm for connection from MCB to Elect Meter by using clips in Meter box all as specified and as directed by Engineer-in-Charge. Note : two runs of cable shall be measured as one unit length complet all as specified and directed by Engr-in-Charge.
Point wiring (concealed to surfaces) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 69.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 69.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Description all as per serial item No- 69.00 here-in-before but for point wiring controlled by two way switches.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination 2-in-1, 3-pin and 5 pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 32 Amps, 240 volts complete all as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
Point wiring (in existing conduits concealed to surface) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in existing conduit of any type and any dia including making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 79.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Description all as per serial item No- 79.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 79.00 here-in-before but for point wiring controlled by two way switches.
Point wiring (in existing conduits concealed to surface) for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in existing conduit of any type and any dia including making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, two way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 5-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination 2-in-1, 3-pin and 5 pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.
Bell push switch, single pole, one way, flush type, 5-Amps, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Door bell, AC, 230 Volts, single pole, ding-dong type sound, complete all specified and as directed by Engineer-In-charge.
Electronic dimmers, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd, complete all specified and as directed by Engineer-In-charge.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings inlcuding retrofit LED lamp of 9 Watt, complete all as specified and as directed by Engineer-In-Charge.
Bed light fittings fancy type with back plate suitable for mounting on wall with LED light of capacity 3 watt complete all as specified and directed by Engineer-in-Charge
Point wiring (in new concealed conduits to surfaces), modular type for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate.
Description all as per serial item No- 93.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 93.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Point wiring (in new concealed conduits to surfaces), modular type, for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate.
Modular stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
Modular bell push switch, single pole, one way, 5-Amps, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Modular socket outlet, 2-in-1, 3-pin, 5-Amps, complete all as specified and as directed by Engineer-In-Charge.
Modular switch piano, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Modular Socket 6Amps/ 16Amps, 2/3-pin combined, 2-module,, complete all as specified and as directed by Engineer-In-Charge.
Modular switch piano, single pole, one way, 15 Amps, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of 4 feet highly engineered plastic body suitable with fully diffused diffuser for general lighting in areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an outstanding solution efficacy of atleast 100 lumen/watt and maximum system wattage of 20 Watts. The electronic driver used shall have a power factor >0.95 and THD <20% with 4 KV internal surge protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Bajaj cat part No BCLSB 20 WH Bajaj /Crompton cat part No BLDL-20-WW or Equivalent makes in Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S&F in replacement of LED mirror light, environmental friendly, ultra modern, energy saving, including LED lamp capacity 10 Watt, 2 feet long, connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified, complete all as specified and as directed by Engineer-In-Charge. Make: Havells/ Philips/ Bajaj/ Crompton.
Replacement of old unserviceable/ damaged Industrial Bulkhead luminaire environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LED 10 Watt and fixing matrials such as clamps, nuts, bolts, washers etc completed including taking down old unserviceable fittings, complete all as specified and as directed by Engineer-In-Charge. Make: Havells Cat Part No- HEXAFT10WLED857SSYMBOPC or equivalent in Philips/ Bajaj.
S&F in replacement of Surface Mounted Ceiling Light LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of both 4000K / 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and an outstanding solution efficacy of atleast 100 lumen/watt and maximum system wattage of 36 Watts.The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% with 3 KV internal surge protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Bajaj cat part No BZSSQL 36L LED WH GX//Crompton cat part No LCTLSNE-36-F0-CDL or Equivalent makes in Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S&F in replacement of Surface Mounted ceiling Light LED 300x300mm luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 1800 nominal lumens and an outstanding solution efficacy of atleast 100 lumen/watt and maximum system wattage of 18 Watts.The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% with 3 KV internal surge protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Bajaj cat part No . BZSSQL 18L WH LED / Crompton cat part No LCTLSNE-18-F0-WW or Equivalent makes in Wipro/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Decorative, wall light fixture made up of Polycarbonate, suitable for 9 W retrofit LED lamp B22 base., including LED lamp of 9 Watt, complete all as specified and as directed by Engineer-In-Charge. Make: Havells ordering cat part No-LHDL02160099 or equivalent in Bajaj/ Philips/ Wipro/ Crompton.
Decorative, 1 N x 9 W LED Lamp wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base including LED lamp of 9 Watt. Make: Havells ordering cat part No-LHFOAJE1TN1I060 or equivalent in Bajaj/ Philips/ Wipro/ Crompton.
Replacement of old unserviceable/ damaged Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 110.00 here-in-before but for sub main wiring (in new conduits concealed to surfaces) alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts.
Sheet metal enclosures in repair for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed.
Sheet metal enclosures in repair for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed.
MCB, Triple Pole and Neutral, 63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, Single Pole and Neutral, 40 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart Including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates reduced by (-40%). (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
SPECIAL NOTE FOR AC, WATER COOLER AND CEILING FAN, EXHAUST FAN REPAIRS : The contractor will submit a scanned copy of Memorandum of under standing from OEMs ( or authorized dealers) for the respective E/M equipments. The details of OEMs are as under:- (a) AIR CONDITIONER (i) HITACHI (ii) BLUE STAR (iii) VOLTAS (iv) DAIKEN (b) FREEZER/DEEP FREEZER (i) LG (ii) SAMSUNG (iii) VOLTAS (C) EXHAUST FANN & CEILING FAN (i) BAJAJ (ii) CROMPTON (iii) HAVELLS (iv) ORIENT (D) WATER HEATERS/GEYSER (i) BAJAJ (ii) HAVELLS (iii) RACOLD
Amount of Schedule of credit of for Rs 2,65,510.00 shall be deducted from quoted amount.
RAJINDER ELECTRICAL WORKS
M/S DC CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .