| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.6 LAccepted-AOC PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | ₹59.6 L Quoted ₹60.2 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹69.8 L+₹9.6 L (16.0%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹69.8 L+₹9.6 L (16.0%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹71.4 L+₹11.2 L (18.7%)Rejected-Finance | ₹71.4 L+₹11.2 L (18.7%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹72.2 L+₹12.0 L (19.9%)Rejected-Finance HOUSE NO 89 BEHIND DD LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | ₹72.2 L+₹12.0 L (19.9%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹73.5 L+₹13.3 L (22.1%)Rejected-Finance SRIKONA POTAPOLA CHHAKA CHANDIPUR ROAD BALASORE ODISHA 756025 | BALASORE | BALESHWAR | ODISHA | 756025 | ₹73.5 L+₹13.3 L (22.1%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹62.9 L
EMD Value
₹1.2 L
Closing Date
6 Mar 2023, 6:00 pmClosed
GARRISON ENGINEER
GE I R and D Chandipur Post Chandipur PIN 756025
SPECIAL REPAIR TO BUILDING NO P 584 AT PXE CHANDIPUR
2023_MES_577889_1
8803/E8
Open Tender
Civil Works
Item Rate
180 days
Chandipur
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandipur
₹1.2 L
Yes
1 Aug 2023
30 Jan 2023
8 Mar 2023
30 Jan 2023
6 Mar 2023
24 Feb 2023
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' PART-I (B/R PORTION)
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. including brushing neat cement slurry with 3.0 kgs of cement per sqm all as specified and directed.
Providing and laying design mix cement concrete of M-30 grade prepared with batch maixing machine, as in floors for tanker movememnt, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Min Cement content considered in M-30 is @ 340 kg/cum.
Extra for providing and mixing hardening compound of approved quality as per manufacturer's specification in cement concrete complete all as specified and as directed.
Dismantling Asbestos Cement sheet roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of complete all as specified and as directed.
Dismantling G.S Sheet roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of complete all as specified and as directed.
Supply and fixing of pre-painted hot-dip galvalume aluminum-zinc alloy metallic coated trapezoidal profile steel sheet 0.50 mm thick (Total Coated Thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 4, coating class AZ150 of an approved colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as directed.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified and as directed.
Supply and fixing of pre-painted hot-dip galvalume aluminum-zinc alloy metallic coated plain steel sheet 0.50 mm thick (Total Coated Thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 4, coating class AZ150 of an approved colour having tensile strength of 550 Mpa as in ridges/facia and similar work, fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as directed.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete for Vally Gutter (600mm overall girth).
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete all as specified and as directed.
S&F Plates 6mm thick (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment of Fe-410-W(Gde-E-250)quality-A) complete all as specified and as directed
M & L for 2 coats painting with synthetic enamel paint of approved brand and manufacture to give an even shade of approved brand and manufacture on new steel galvanised iron/steel works complete all as specified and as directed.
Preparation of old painted surfaces of steel and applying two coats synthetic enamel paint to steel surfaces of any description not otherwise described over 10cm width or girth.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade over existing cement paint old surface (Two or more coats applied @ 1.43 ltr/ 10 sqm) over a coat of exterior primer inluding complete removal of ext treatment all as specified and as directed.
M&L for 15mm thick in CM 1:4 cement plaster on brick or concrete surfaces complete all as specified and as directed.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade on wall plastered/concrete surface (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Providing and fixing precast re-inforced cement concrete 1:1.5:3 (using 20mm graded stone aggrgate) as in drain cover slabs including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand) complete all as specified and as directed.
S & F TMT bars of grade Fe-500D or more for R.C.C. work including straightening, cutting, bending, placing in position and binding all as specified and as directed
S&F 40mm Unplasticised PVC pipes of pressure rating 10kg/cm2 laid in cover slab as wipe hole of cover slab.
M & L forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with Grade 'A' sealing compound complete all as specified and as directed.
M & L forming construction joints 30mm deep x 10mm wide filled with Grade 'A' Sealing compound complete all as specified and as directed.
Providing and fixing 12mm thick pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
Providing and filling in position rubberized bitumen hot sealing compound of grade 'A' conforming to IS:1834 for sealing of expansion joints in roads / cement conrete pavements all complete as per direction of the Engineer-in-Charge complete all as specified and as directed.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of nominal out dia of 200mm conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion complete all as specified and as directed
Demolishing brick work manually/ by mechanical means buit in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in cement mortar 1:4 complete all as specified and as directed.
Brick work with old bricks obtained from demolition in superstructure above plinth level up to floor five level in cement mortar 1:4 complete all as specified and as directed
Provoding and laying in position of cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) as in surface channel and drain complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm innner girth in cement concrete, using extra cement, including forms ,moulds, mi-tred/stopped.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and as directed.
Dismantling C.I. or asbestos/PVC rain water pipe of dia 200mm with fittings and clamps including stacking the material within 50 metres lead complete all as specified and as directed.
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes of dia 200m by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories (200mm dia Bend 87.5°) for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories (200mm dia Shoe (Plain)) for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
SCHEDULE 'A' PART-II (E/M PORTION)
Taking down carefully copper/aluminium point wiring including sunken MS boxes (light, fans,exhaust fan, call bell) complete, (fittings such as switches, ceiling roses,call bell, pendants, regulators, socket etc by unscrewing from board carefully and making good disturbed surfaces of walls, floors etc complete all as specified & directed.
Taking down carefully copper/aluminium wiring including sunken MS boxes for 5A and 16 A socket wiring complete, by unscrewing from board carefully and making good disturbed surfaces of walls, floors etc complete all as specified & directed.
M&L for point wiring for light point/fan point/exhaust fan point/call bell point with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1.5 Sqmm for earth continuity wire, to be drawn in and including PVC conduit medium duty with concealed wiring, MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick switch board with 5/6 A piano switch flush type one way 240 V and brass screws with cap washers for one light/Fan point controlled by one single way switch including all necessary wall cutting and making good disturbed surface complete.
M&L for Light/power plug for 05/15 A Independent switch socket board with PVC insulated unsheathed stranded FRLS copper conductor cable of size 2x4 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1x4 Sqmm for earth continuity wire, to be drawn in and including PVC conduit heavy duty with concealed wiring including all necessary wall cutting and making good disturbed surface
S& F metal boxes of size 75mm x75mmx 60mm deep of thickness 1.2mm on surface or recess with suitable size of phenolic laminated sheet cover of thickness 3mm in front including painting and making good of good disturbed surfaces
S& F metal boxes of size 150mm x75mmx 60mm deep of thickness 1.2mm on surface or recess with suitable size of phenolic laminated sheet cover of thickness 3mm in front including painting and making good of good disturbed surfaces
S&F Socket outlet 3 in 1, 5 pin, 5 Amps flush type 240 Volt .
S&F Socket Outlet, 5 in 1 ,3 pin 15/16 amps flush type 240 Volt
S&F Switch 5/6 Amps flush type 240 Volt .
S&F Switch 15/16 Amps flush type 240 Volt .
S&F Ceiling rose 5A, 3 terminal PVC/poly carbonate isolated body ON existing jucntion box including connectionsets as required
Taking down unserviceable sub main /Sub circuit wiring of any type and size including conduit, batten wiring for necessary repair/replacement
M&L Sub main wiring using two runs of FRLS grade PVC insulated, unsheathed ,stranded, copper conductor cable of size 2.5 Sqmm and one run of 2.5 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including at least 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures
M&L Sub main wiring using two runs of FRLS grade PVC insulated, unsheathed ,stranded, copper conductor cable of size 4x6.0 Sqmm and 2 x 6.0 Sqmm earth wire FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including at least 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures
M&L Sub main wiring using two runs of FRLS grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 4 Sqmm and one run of 4 Sqmm FRLS grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including at least 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures
S&F factory made sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug top and socket complete with one single pole MCB 20A (SPN) Amps on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. with taking down old U/S existing sheet metal enclosure.as required all as specified.
Supply and fixing in repair triple pole and Neutral 415 volts and earth enclosers with three pin with earth plug with socket complete sheet metal enclosure box with 20 Amps MCB (TP) 'C' series on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc with taking down old U/S existing sheetmetal enclosure.
Supply and fixing in repair designed to deliver optimum performance under harsh industrial enviroments to provide significant & sustained energy saving over the product life cycle resulting in enhanced productivity & safety 100 watt LED and including connecting up with two core 2.5 sqmm copper conductor cable including taking down old light fitting complete all as specified and directed. (Make /Model No :-LH21-162-060-57-XX(Radial UNO/LH21) of Wipro or equivalant model of make list as per Appex 'A'.
Supply and fixing in repair highly robust industrial Box type LED extruded Batten type indoor decorative type luminaire suitable for LED Tube 2x 16/20 watt (4ft ) complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fitting complete all as specified and directed. ( Make /Model No :-IGP162LT8-16( ECO-I ) of Crompton or equivalant model of make list as per Appex 'A'.
Supply and fixing in repair highly robust industrial Box type LED extruded Batten type indoor decorative type luminaire suitable for LED Tube 1x 16/20 watt (4ft ) complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fitting complete all as specified and directed. ( Make /Model No :-IGP161LT8-16( ECO-I ) of Crompton or equivalant model of make list as per Appex 'A'.
Supply and fixing in repair LED Polycarbonate T8 Tube with in built driver with metal heat sink double sided connection of capacity 1x 20 watts ,Make/Model No:-LT8-20-865-(2) ULTRON of Crompton or equivalant model of make list as per Appex 'A'.
Supply and fixing in repair high performance LED streeet light 150 watt , contemporary designed housing made of die-cast aluminium with street optic lens for uniform light distribution rated IP66, including provn of necessary connection complete including taking down olf building security light (Make/ Model:- LR02-182-XXX-57-G2 of Wipro or equivalant model of make list as per Appex 'A'.
Taking down old Feeder Pillar Box and Supply and install, testing & commissioning on repair CPRI approved LT panel board indoor type wall mounted CRCA made of sheet, factory made, suitable for 415 volts 3 phase 4 wire 50 Hz AC supply system of adequate size, open on both back and front side having hinger and locking arrangements having bubars chamber with aluminium bus bar with vertically arranged of 400 amps rating duly insulated by insulation of RYB colour mounted on porecelain insulators.The panel shall be made out of 3.15 mm thick CRCA sheet powder coated based on MS channel for arrangement of foundation of foundatiion nuts, bolts and washers (Make Universal switch gear control/C&S/Neptune/Power system & control) The panel should be protected with IP -54 in accordance with IEC 60529. The gasket materials shall be polyurethane white the materials shall be internally embeded the panel should be included with internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incomming and outgoing cable etc and supported on MS angle, LED indicating lamps, current transformer, terminal block for cables and including making of suitable size foundation as per manufacturer recommended and taking down old unserviceable panel/fidder pillers alongwith all accessories all as directed at site and to incorporte the following:- (A) INCOMMING (i) MCCB four pole 415 Volts AC Supply,DU250, 250 Amps, thermal magnetic release type 36 KA -01 Nos, Rotary handle 1 Nos,Seperator link Each set 1 Nos.,Make:- L&T,Cat No:- CM98065OOPO or equvt Cat of make list as per Appx 'A' (ii) Panel mounted multi function meter for measuring Voltage (0-500 Volts), Current(0-500 Amps) and frequency Make:- L&T,Ct No:-MFM4410LCDmeter Cl 1 with RS485 or equvt Cat of make list as per Appx 'A (B) OUTGOING (a) MCCB FP pole 415 Volts AC Supply,DU125H, 125 Amps, thermal magnetic release type 30KA - 04 Nos, Rotary handle 4 Nos, Seperator link Each set 4 Nos. Make:- L&T,Cat No:- CM90679OOLO or equvt Cat of make list as per Appx 'A (b) MCCB 4 Pole 415 Volts 18 kA 32 Amp rating thermal magnetic release type.-02 Nos Make:- L&T,Cat No:- CM9051700FO or equvt Cat of make list as per Appx 'A
Supply and fixing of VTPN DB double door,IK 09,IP43-Metal door, 4 way, made of CRCA sheet steel ,RAL 9003,powder coated with bus bar, neutral link, earth bar withprovision for DU125A MCCB,4 pole as incomer and SP/TP MCBs as Outgoings, including taking down old one.( Make/Model- DBVTL004DD of L&T or equivalant Cat part of make list as per Appx 'A'.
S&F MCCB 4 pole,200 Amps, for Incomer of VTPN with fixed thermal & magnetic release of breaking capacity 36kA, DU125H (Icu=30kA, Ics=50% Icu), 415 Volts.
Taking down serviceable / unserviceable switch fuse unit/MCB DB with MCB etc for necessary repair/replacement and reuse all as directed by Engineer in Charge.
S&F MCB DB double door made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and din rail of SPN 8 way, 240 Volts double door fixed in wall , making good disturbed surfaces, including taking out old DB with fiyyings & fixtures complete
S & F MCB 40 Amps SPN `C' series,Make:L&T,,Cat No-BB20400C or equivalant Cat part of make list as per Appx 'A'.
S & F MCB 40 Amps SP `C' series,Make:L&T,,Cat No-BB10400C or equivalant Cat part of make list as per Appx 'A'.
S & F MCB 06 to 32 Amps SPN `C` series.
Supply and fixing in repair of GI pipe Bracket of 40 mm dia light grade pipe bend to shape of approx length 1.5 Mtr including 2 no. MS Clamp of flat iron size 40x6 mm complete with nut, bolt, washers all as specified and directed. (Make of GI pipe- Jindal/Prakash/Tata)
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6.0 mm buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level ) connected to galvanized earth lead strip of size 25 mm x 5 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40 mm dia medium grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia of length 2.7 m, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with Masonary earth pit of size 300mm x300mm , mortar 1:6 with Common burnt clay F.P.S. (non modular) bricks class designation 7.5 and outer plaster with cement mortar 1:4 of 10cm thickness,CI/MS cover plate hinged to frame with Locking arrangement as pit cover including galvanised strip of size 25 mm x 5 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a disance not exc 50 mtr and necessary connection and testing complete including taking down old one , and all as directed and specified
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drwan in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc.as required 25x5 mm dia galvanised iron strip all as specified and directed.
national engineering
NARESH KUMAR BEHERA
M/S HIGHLAND ENGINEERING
bholanath bera
R.B.Construction
MS SUBHAM ENGINEERING AND CO
Bidder Name
national engineering
RANA ENTERPRISES
R.B.Construction
M/S HIGHLAND ENGINEERING
MS SUBHAM ENGINEERING AND CO
bholanath bera
NARESH KUMAR BEHERA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .