| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-AOC PLOT NO HIG 7 CHUNVATI LANE GOPALGAN BALASORE 756001 | BALESHWAR | ODISHA | 756001 | ₹3.0 Cr | L1 | Accepted-AOC AOC HAS BEEN AWARDED TO THE L1 FIRM. |
| 2 | L2₹3.3 Cr+₹25.5 L (8.49%)Rejected-Finance | ₹3.3 Cr+₹25.5 L (8.49%) | L2 | Rejected-Finance Not Being the Lowest Bidder |
| 3 | L3₹3.3 Cr+₹29.9 L (9.98%)Rejected-Finance | ₹3.3 Cr+₹29.9 L (9.98%) | L3 | Rejected-Finance Not Being the Lowest Bidder |
Tender Value
₹3.0 Cr
EMD Value
₹6.0 L
Closing Date
6 Jan 2020, 2:00 pmClosed
Chief Construction Engineer R and D East
Chief Construction Engineer R and D East napier Road,Po-Hastings, Kolkata - 700022 West Bengal.
Special Repairs to Transit Facility (Sagar Darshan) at Chandipur, Balasore.
2019_DRDO_523970_1
CCE R and D EAST/ENQ-72/CIV/BLS/2019-20
Limited
Civil Works
Item Rate
365 days
Chandipur
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,000
Yes
CCE (R and D)East
₹6.0 L
Yes
14 Feb 2020
4 Dec 2019
7 Jan 2020
4 Dec 2019
6 Jan 2020
17 Dec 2019
6 Dec 2019 - 3 Jan 2020
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) 300 mm dia piles
Extra for provding richer mixes at all floor level. Providing M-30 grade of Concrete instead of M-25 Grade. Note- Cement Containt considered in M-30 is @ 340 kg/Cum.
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately) All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
(ii) Chemical Grouting. Providing and fixing Chemical grout Drilling 20mm dia holes in sheet rock upto a depth of 0.5m, including labour and machinery all complete.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 800x800 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete Size of Tile 800x800 mm
Mat Finished Non Skid Floor Tiles 600x600mm
Mat Finished Non Skid Ceramic Floor Tiles 400x400mm
Mat Finished Non Skid Floor Tiles 600x600mm or 300x300mm Non Skid Vitrified Tiles
Mat Finished Non Skid Ceramic Floor Tiles 400x400mm or 600x600mm
Glossy Ceramic Wall Tile 300x600
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture ofsize 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanizing @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid,
including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/ mK.
12.5 mm thick Wooden False Ceilling
Providing afitting and fixing Sal wood choukath for doors and windows of 150 x 65 with MS hold fast and painted with bituminous paints on back side , etc. including cost of conveyance , royalities and taxes of all materials and cost of labour T&P required for the work etc. complete as per drawing design and direction of Architect/Engineer-in-charge.
Supplying and fixing 35mm thick flush door Shutter both side veneer furnished with polished
French spirit polishing 35mm thick flush door Shutter
Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive
Providing and fixing in position aluminum composite panel paneling with PVDF coating & LDPE core Altobond /Alukbond exterior grade 4 m thick with composite of (0.5 mm – 3 mm – 0.5mm) including fabrication for the same with aluminum section, required hardware, silicon sealant (Dow corning 789) masking tape necessary scaffolding etc, as detailed in drawing complete in all respect.
Grinding of existing kota stone floor to achieve mirror polished quality
Grinding for existing kota stone skriting to achieve mirror polished quality
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing wall with one coat of premium exterior paint (Apex or Excel total) on old grit wash and over priming coat of priming coat.Complete in all respects as per the direction of the Engineer-in-charge.
Cleaning of Grit Wash shall be paid by separate Item.
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Credit for Steel of above item.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Credit for doors & windows as (steel or wood) of above item.
Dismantling of Cup Board
Providing and fixing of Cup Board made of 19 mm block board / BWR grade ply of depth 600 mm, all external surface finished with 1 mm thick laminate of approved shade and pattern as per directions of Enigneer-in-Charge. (Front elevation area to be measured for payment purpose)
Providing and fixing of Cup Board
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead For thickness of tiles above 25 mm and up to 40 mm
Dismantling of Wash basin
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge
Dismantling of CP Fittings
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge In cement mortar
Credit for brick work in Nos. of above item.
Providing and fixing EWC White colour vitreous china S type water closet (Hindware Cat No. 92094 (S-30)) Modena or (Hindware Cat No. 92093 (S-30)) Twilight or equivalent
Providing and fixing under counter wash basin with MS/C.I. brackets, 15 mm C.P. basin mixture,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :(Basin - Hindware, Cat. no : Zen 10049 size 560x450mm & Pillar cock make - Jaquar, Cat. no:FLR-5011 or Basin mixture make - Jaquar, Cat. no:FLR-5167NB. )
Providing and fixing Bottle Trap 32mm Size With 250mm Cat no- ALD-CHR-769 of Jaquar/Equivalent.
Providing ,fitting and fixing C.P. Brass wall mixer of Make Jaquar continental, or equivalent. (Jaquar Cat No. FLR-5281N)
Providing and fixing 1200X1000 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
Providing and fixing of 5 mm thick mirror on existing wall including fabrication as per directions of Enigneer-in-Charge complete in all respect.
Providing and fixing 5mm thk beveled edge mirror of superior glass (of approved quality) fixed with teak wood beading size 50 x 20mm with French Spirit polish, 6 mm thick water proof ply wood on back of the mirror complete with two or more coats of black bitumeneous paint at the back of ply.
Providing and fixing toilet paper holder : CAT No- ACN-CHR-1151N of Jaquar/Equivalent.
Providing, fitting & fixing of Hand Shower (Health Faucet) with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook-Cat no-ALD-CHR-573
Providing and fixing 15 mm nominal bore C.P. brass short body two way bib cock of approved quality conforming to IS : 8931 .make of Jaquar cat no-FLR-5041 N/equivalent
Providing fixing C.P. brass towel rack of size 600 mm long fixed to wooden cleats with CP brass Screws complete as per instructions of the engineer-in-charge .Cat No- AKP-35781PS of Jaquar make/ Equivalent design & make.
Providing and fixing approved type SS coat hooks with concealed type screws of approved make. Jaquar ACN-1161N or equivalent)
Supplying & Fixing C P Soap Dish of approved make complete as directed Make :- Jaquar or equivalent) Catno-ACN-1131 N
Providing and fixing Angle Stop Cock with wall flange Make Jaquar FLR-5053N
Providing and fixing Shower Rose with Shower Arm Make Jaquar OHS-1843 and Make Jaquar SHA-483
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall 20 mm nominal outer dia Pipes
Providing and fixing 12 mm thick frameless toughened glass panel of approved brand and manufacture, including providing and fixing ss channel at top including silicon sealent at joints and bottom , ect all complete as per direction of Engineer-in-charge.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25mm thickness
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
(b) Fabricating and supplying serrated M.S. hot dip galvanised /Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of ressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of above item
For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Providing and fixing colour Hollow profile polycarbonate sheet 10mm on existing frame with complete bubber gasket nut bolt etc all complete as per direction of the engineer in charge.( Size and colour approved by client)
Supplying and fixing testing and commisioning 6A modular type switch including junction box modular plate & all fixing accessories. (Make - Wipro A0110)
Ceiling fan controlled by One No. 6A switch & Electronic Regulator of 300 Watts step type and Concealed MS fan hook box.
One 5A Plug Skt. Controlled by one 6A switch ( independent)
Supplying and fixing of 15A/5A 6 pin sockets with 15A switches of the combination modular type, in GI switch box front plate in PVC existing conduit of 2 mm thickness & of minimum size 25 mm dia with the same size of conductors.
Supplying and fixing of 20amps, 240volts, SPN Industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps 'C'series SP MCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc.as required .
Supply & fixing of 1400mm sweep Ceiling Fan including down rod, necessary wiring, ceiling rose etc all complete.
Decorative fan Crompton HS Decora/Aura/Aventure
8 Way double door SPN DB for incomer, 1nos. 32A DP MCB and outgoing 6nos 6 to 32 A SPN MCB (without MCB)
Light Fixtures Supply, installation and testing of following types of LED light fixtures directly on wall / ceiling/false ceiling of building with all accessories such as perpex sheet cover,down rod etc complete assembly and making connection from the suitable point outlet as per the direction of Engineer-in-charge. Ceilling Light 18W round type Make Wipro Cat No. LD80-171-XXX-60-XX
Tube Light 20W Make Wipro Cat No. LM34-251XXX-57DCT
Tube Light 20W Make Wipro Cat No. LM34-251XXX-57DD
Bracket Light Camp E-14 LED 4Wx1 Make Jaquar Cat No. WBR-CHR-MB12021192A
Mirror light 31W (Make - Wipro LW04-411-XXX-57-XX 5700)
Cove Light Make Wipro Cat No. LS06-015-120-WW-50
Ceilling Light 36W for Corridor 608x608mm Make Wipro Cat No. CRCO10RO38HP57GL
Down Light 18W (Make - Wipro LD80-171-XXX-60-SM)
Outdoor type Light 26W (Make - Wipro CRDL11S033HP57)
Gate Light 45W (Make - Wipro LP02-501-XXX-57-XX 5700)
AREA LIGHTING. Supply, delivery, instalation, testing & commissioning of following types of street light luminaire shaped single piece for improved aesthetic lamp etc including 1.5 sqmm copper wires as complete wiring etc complete as required with all materials including 9.00 meter height stepped die cast aluminium pole, PVC loop in loop out box, concrete foundation for pole etc. all complete as per direction of Engineer - in -charge.80W LED street light fittings, GI pipe medium grade 40 mm dia bent to shape for fixing street light fitting, one pair of MS clamp, bolt, nuts, washer etc all as directed. (Make - Wipro LR02-981-xxx-57-xx)
VASTU SHOBHA
S. R. ASHOK & ASSOCIATES PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .