Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance 701 SKYWALK TOWERS TANK LANE ORLEM MALAD WEST MUMBAI MAHARASHTRA 400064 | MUMBAI SUBURBAN | MAHARASHTRA | 400064 | ₹1.9 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical A304 SILVER BIRCH VASANT GARDEN MULUND WEST MUMBAI SUBURBAN MUMBAI MAHARASHTRA 400080 | MUMBAI SUBURBAN | MAHARASHTRA | 400080 | - | - | Rejected-Technical DUE TO SHORTFALL OF REQUISTE DOCUMENTS |
| 3 | Rejected-Technical | - | - | Rejected-Technical DUE TO SHORTFALL OF REQUISTE DOCUMENTS |
| Sl No | Description | Qty | Unit | AXENIC SYSTEMS L1 |
|---|---|---|---|---|
| 1.00 | WASHING AREA(60sq,mtr)
30mm Wall Cladding panel SS304 0.8mm & PPGI 0.5mm | 125 | sq.mtrs | 5,913.57 ₹7,39,196.25 Lowest |
| 1.10 | WASHING AREA(60sq,mtr)
50mm Wall Partition panel Both side SS304 0.8mm | 25 | sq.mtrs | 8,274.75 ₹2,06,868.75 Lowest |
| 1.20 | STERILE STORE AREA(93sq.mtr)
30mm Wall Cladding panel SS304 0.8mm & PPGI 0.5mm | 165 | sqmtrs | 5,913.57 ₹9,75,739.05 Lowest |
| 1.30 | STERILE STORE AREA(93sq.mtr)
50mm Wall Partition panel Both side SS304 0.8mm | 35 | sq.mtrs | 8,274.75 ₹2,89,616.25 Lowest |
| 1.40 | DIRTY STORE AREA(105sq.mtr)
30mm Wall Cladding panel SS304 0.8mm & PPGI 0.5mm | 155 | sq.mtrs | 5,913.57 ₹9,16,603.35 Lowest |
| 1.50 | DIRTY STORE AREA(105sq.mtr)
50mm Wall Partition panel Both side SS304 0.8mm | 65 | sq.mtrs | 8,274.75 ₹5,37,858.75 Lowest |
| 1.60 | CSSD OFFICE/PACKING AREA(85sq.mtr)
30mm Wall Cladding panel SS304 0.8mm & PPGI 0.5mm | 145 | sq.mtrs | 5,913.57 ₹8,57,467.65 Lowest |
| 1.70 | CSSD OFFICE/PACKING AREA(85sq.mtr)
50mm Wall Partition panel Both side SS304 0.8mm | 40 | sq.mtrs | 8,274.75 ₹3,30,990 Lowest |
| 1.80 | CSSD OFFICE/PACKING AREA(85sq.mtr)
50mm Ceiling panel SS304 0.8mm & PPGI 0.5mm | 340 | sq.mtrs | 7,412.76 ₹25,20,338.4 Lowest |
| 2.00 | S.S. 304 Coving & Connecting Profile
All joints between Panel to Panel, Wall to ceiling, Wall to Floor shall be covered with SS 304 coving section
• Minimum radius min.50 mm.
• Joint between coving and surface shall be sealed with silicon sealant. | 650 | rmt | 1,269.09 ₹8,24,908.5 Lowest |
Tender Value
₹2.4 Cr
EMD Value
₹4.8 L
Closing Date
23 Oct 2025, 4:00 pmClosed
Superintending Engineer, Mechanical Hospital Circ
Superintending Engineer, Mechanical Hospital Circ
UpGradation of Central Sterilization Supply Department at GMCH, Jammu.
2025_PWDJK_278044_3
MHCJ/Tech/e-NIT/2025-26/02
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
120 days
GMCH JAMMU
as per e nit
2 documents required · 2 mandatory
₹3,000
Superintending Engineer, Mechanical Hospital Circ
₹4.8 L
13 Dec 2025
8 Oct 2025
24 Oct 2025
8 Oct 2025
23 Oct 2025
11 Oct 2025
8 Oct 2025 - 18 Oct 2025
Amount
WASHING AREA(60sq,mtr) 30mm Wall Cladding panel SS304 0.8mm & PPGI 0.5mm
WASHING AREA(60sq,mtr) 50mm Wall Partition panel Both side SS304 0.8mm
STERILE STORE AREA(93sq.mtr) 30mm Wall Cladding panel SS304 0.8mm & PPGI 0.5mm
STERILE STORE AREA(93sq.mtr) 50mm Wall Partition panel Both side SS304 0.8mm
DIRTY STORE AREA(105sq.mtr) 30mm Wall Cladding panel SS304 0.8mm & PPGI 0.5mm
DIRTY STORE AREA(105sq.mtr) 50mm Wall Partition panel Both side SS304 0.8mm
CSSD OFFICE/PACKING AREA(85sq.mtr) 30mm Wall Cladding panel SS304 0.8mm & PPGI 0.5mm
CSSD OFFICE/PACKING AREA(85sq.mtr) 50mm Wall Partition panel Both side SS304 0.8mm
CSSD OFFICE/PACKING AREA(85sq.mtr) 50mm Ceiling panel SS304 0.8mm & PPGI 0.5mm
S.S. 304 Coving & Connecting Profile All joints between Panel to Panel, Wall to ceiling, Wall to Floor shall be covered with SS 304 coving section • Minimum radius min.50 mm. • Joint between coving and surface shall be sealed with silicon sealant.
Manual Hinged Door: MOC SS 304 Designed to fit flush into the wall panel system on both sides, fabricated from SS 304 Coated Sheets. • Thickness: Shutter has sheet thickness of 0.8mm and the frame of 1.2mm. Door Leaf thickness of 46mm • Width: Standard 50/60/80 mm panel has frame width of 50/60/80 mm and shutter width of 42mm. • Infill: PUF Insulation Handle on One side, Stainless Steel Push Plates on “Push” Side, Kick Plates, Automatic Bottom Drop Seal, Concealed Tower Bolt (only for Double door), • View Window: Double insulated glass flushed to the door faces, 6mm thick plain Toughened View Glass with Black border & Sealant • Door lock: Both side key operated locking arrangement • Door size: as per the site requirements. Door opening shall be as per requirements / space availability (5.0Ft W X 6.9Ft H )
Manual Hinged Door: MOC SS 304 Designed to fit flush into the wall panel system on both sides, fabricated from SS 304 Coated Sheets. • Thickness: Shutter has sheet thickness of 0.8mm and the frame of 1.2mm. Door Leaf thickness of 46mm • Width: Standard 50/60/80 mm panel has frame width of 50/60/80 mm and shutter width of 42mm. • Infill: PUF Insulation Handle on One side, Stainless Steel Push Plates on “Push” Side, Kick Plates, Automatic Bottom Drop Seal, Concealed Tower Bolt (only for Double door), • View Window: Double insulated glass flushed to the door faces, 6mm thick plain Toughened View Glass with Black border & Sealant • Door lock: Both side key operated locking arrangement • Door size: as per the site requirements. Door opening shall be as per requirements / space availability (3Ft W X 6.9Ft H )
Antistatic Conductive Flooring • Thickness: : 2.00mm
Ceiling Peripheral Lights / OT Luminaires: LED Type Clean Room Recessed Type Luminaires, IP-65 grade • Brightness: 1000 Lux illumination above 1 MTR floor level around the ICU Beds. • The light fixture will be hermetically sealed from top side (ceiling side) with bottom opening for repair & maintenance. • Size: 2ft. x 2ft. 46W
Ceiling Peripheral Lights / OT Luminaires: LED Type Clean Room Recessed Type Luminaires, IP-65 grade • Brightness: 1000 Lux illumination above 1 MTR floor level around the ICU Beds. • The light fixture will be hermetically sealed from top side (ceiling side) with bottom opening for repair & maintenance. • Size: 1ft. x 1ft. 26W
MEDICAL GRADE HVAC SYSTEM Ceiling flushed Supply and Return air diffuser Aluminum powder coated Diffuser with Manual VCD.
External Air Handling Unit (AHU) Supply installation, testing and commissioning of Horizontal type CEILING mounted Double Decker/Single Decker, Double Skin Air Handling Unit with 43±2 mm thick puf panel having puf density 38+/- 2 kg/m3 with thermal break extruded aluminum profile, The inner skin 0.6 mm (24G) plain GI & outer skin 0.63 mm (24G) pre coated GI construction with internal coving, Imported backward curved DIDW type centrifugal fan witth motor suitable for VFD/DOL,Air tight access door for mixing chamber, fan, filters & coil sections. Reqd. Port with silicon tubing for measuring differential pressure across all filters with help of magnehelic gauges with SS 304 box & nozzles. inlet, outlet,Bleed, FA shall have extruded aluminium opposed blade dampers with locking arrangement, SS 304 drain tray with threes die slop, DX type cooling coil, heaters for heating, limit switch, lamp for fan section, protective guard, and reqd. accessories. All filters are suitable for 60 deg c. Internal cabling with junction box, Drain U- traps,Temp. measurement sleeves. Sheet metal sectionalised cabinet type air handling unit in double skin construction fabricated from Al extruded section frame structure. The inner skin 0.6mm (24G) plain GI & outer skin 0.63 mm (24G) pre coated GI construction with 43±2 mm thick and density of 38 ± 2 kg/m3 PUF insulation panel, with internal coving and in thermal break construction. Pencil coving should be given on the inner frame of AHU. The coving should be an integral part of the frame and not applied separately. 12000CFM/125mmwg / 30.0TR Triple ckt / 18KW electric strip heater / 10+3+0.3 (Combi+HEPA)Mic Air filteration / 18HP VFD compatible Motor
External Air Handling Unit (AHU) Supply installation, testing and commissioning of Horizontal type CEILING mounted Double Decker/Single Decker, Double Skin Air Handling Unit with 43±2 mm thick puf panel having puf density 38+/- 2 kg/m3 with thermal break extruded aluminum profile, The inner skin 0.6 mm (24G) plain GI & outer skin 0.63 mm (24G) pre coated GI construction with internal coving, Imported backward curved DIDW type centrifugal fan witth motor suitable for VFD/DOL,Air tight access door for mixing chamber, fan, filters & coil sections. Reqd. Port with silicon tubing for measuring differential pressure across all filters with help of magnehelic gauges with SS 304 box & nozzles. inlet, outlet,Bleed, FA shall have extruded aluminium opposed blade dampers with locking arrangement, SS 304 drain tray with threes die slop, DX type cooling coil, heaters for heating, limit switch, lamp for fan section, protective guard, and reqd. accessories. All filters are suitable for 60 deg c. Internal cabling with junction box, Drain U- traps,Temp. measurement sleeves. Sheet metal sectionalised cabinet type air handling unit in double skin construction fabricated from Al extruded section frame structure. The inner skin 0.6mm (24G) plain GI & outer skin 0.63 mm (24G) pre coated GI construction with 43±2 mm thick and density of 38 ± 2 kg/m3 PUF insulation panel, with internal coving and in thermal break construction. Pencil coving should be given on the inner frame of AHU. The coving should be an integral part of the frame and not applied separately. Ductable Supply & Exhaust FDV Unit considering Blower,motor and Pre filters sections with necessary ducting and terminals etc for Washing area only
AIR DISTRIBUTION SYSTEM HVAC Ducting : 24 G As per SMACNA class ‘A’ (Qty may vary according to site condition) Supply, Installation and Testing of CNC machine fabricated G.S.S. Ducting should be complete with - • supports, with GI rivets, nut-bolts, with Epoxy painted MS angle Flanges, with 5mm thick neoprene gaskets duly installed between flanges. • Food grade silicon sealant shall be applied in the longitudinal length of a ducts & for all angle flanges.
HVAC Duct Insulation : (Qty may vary according to site condition) • Duct Insulation with site-glued, Aluminum foil faced, • Closed cell fire rated (FM approved) Nitrile Rubber Insulation of suitable density (40 - 60 kg / m³), • Class “O” insulation as per thickness specified, • All joints and corners should be finished with 50 MM wide cross linked oven type Aluminum Self Adhesive Tape. • Size: 19mm for Supply Air Ducts, 13mm for Return Air & Exhaust Air Ducts
Volume control damper for air balancing to be provide in duct
Fire damper with fusible link
CONDENSING UNITS (Outdoor Units) & REFRIGERATION PIPING Condensing Units / Air Conditioning ODU (11.5TR) Supply, Installation, Testing & Commissioning of Air-cooled condensing unit. • Outdoor unit should be completed with copper piping, filled with R410a refrigerant gase, • Including nitrile rubber Insulation, electrical cabling, thermostatic expansion valves, liquid line strainer, HP, LP switches, control panel along with all other required electrical • With supports, tray, MS stands etc. • Consider 15 meter length between AHU & Outdoor Unit. • Multiple circuits and components.
Refrigerant piping in compliance with Supply, Installation, Testing & Commissioning of copper piping with all necessary fittings for refrigerants • Copper tubing, Expansion Valve, Dryer Filter, Gas charging etc. refrigeration accessories
ELECTRICAL & INSTRUMENTATION AHU Sub Panels 18HP VFD ONLY • Supply, Installation, Testing & Commissioning of floor mounted local AHU panel • With VFD & with bypass arrangement • MOC - 16 gauge CRCA powder coated construction suitable to house VFD (with harmonic filter) for fan motor.
Power Cables for HVAC & Complete electricals Supply, Laying, Testing and Commissioning of Industrial Grade Flexible single core / multi-core cables as per site requirements Standards flexible braid power cables of various sizes as per the requirement. • Laying of Cables in horizontal/vertical formation on wire mesh cable trays, supported along RCC/steel structures if required, pipe racks and cable supports provided,
Main Distribution panel (3Phase O/P Feeder) Bus bar chamber with AMF meter Separate distribution boxes shall be provided for the separation of cabling from the CCSD room to the existing DG/Transformer of the hospital. Including Main Incomer MCCB,MCB o/p feeder for Sockets,Lights,3Phase Eqipments,HVAC etc.
Switchboards & Sockets, Internal Wiring for lights & sockets etc(6/16Amp 1P/3P Min. 30nos) Switchboards & Sockets with necessary number of modular box, polycarbonate front and rear plate, modular switches, switch sockets & blank plates. ▪ Switchboard points & Light points • Switchboard Wiring 3C x 2.5 Sq.mm Cu. PVC Flexible FR Cable including Termination at both ends.
OTHER ANCILLARY WORKS Ancillary Civil Work including Demolition All jobs such as demolition / breaking / reconstruction of doors / windows / walls/Pipes /existing CSSD equipments etc. required for work: installation / fitment of Doors / Windows / Scrub / Water proofing /civil foundation/Plumbing and drain etc. required for completion of the said modular CSSD setup.
Fabrication Work Fabricated structure / shed for AHU & Outdoor units, Supports / Stands / Ladders for Ducting, AHU, ODU, Electrical wiring etc.
CSSD Plumbing work required wherever necessary Includes Hot water,Cold water pipes with necessary fitting and valves etc.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
BOQ_936170.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .