Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹44.2 L+₹2.4 L (5.83%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Neither lowest nor competitive | |
| 3 | L3₹46.0 L+₹4.3 L (10.2%)Rejected-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC Neither lowest nor competitive | |
| 4 | L4₹46.5 L+₹4.8 L (11.5%)Rejected-AOC C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L4 | Rejected-AOC Neither lowest nor competitive | |
| 5 | L5₹49.9 L+₹8.2 L (19.5%)Rejected-AOC 216 UGF RAM VIHAR ANAND VIHAR DELHI 110092 | SHAHDARA | DELHI | 110092 | L5 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
11 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-I AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
2020_MES_404196_1
GE/C-62/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt
₹98,000
Yes
23 Jan 2021
16 Dec 2020
13 Jan 2021
16 Dec 2020
11 Jan 2021
30 Dec 2020
16 Dec 2020 - 30 Dec 2020
60 days
Amount
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose soil complete all as specified by Engineer-in-Charge.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone agg as in foundations, filling and mass concrete complete all as specified by Engineer-in-Charge
M&L for brick work with sub class 'B' bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1 : 6 . complete all as specified by Engineer-in-Charge
Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified by Engineer-in-Charge
M&L for 100 mm thick cement concrete 1:4:8 type C-2 (using 40 mm graded stone aggregate) as in floors laid in panels and finishing top surfaces of cement concrete even and smooth complete all as specified by Engineer-in-Charge
M&L for Non-skid ceramic colour tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thickscreed bed or bedding layers in cement mortar(1:6) complete all as specified by Engineer-in-Charge
Glazed ceramic tiles in vertical surface 300x200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl 10mm thick backing coat or bedding layers in cement mortar(1:3) complete all as specified by Engineer-in-Charge
M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in floors laid in panels and finishing top surfaces of cement concrete even and smooth complete all as specified by Engineer-in-Charge
S&F frame work such as grills, frame, gates,gratings etc ends of bars shouldered and/or riveted, welded or forged into spikes, framed guard bars and work conforming to Fe 410-0 complete all as specified by Engineer-in-Charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified by Engineer-in-Charge
Removing excavated meterial n exc 50m and depositing where directed at a level n exc 1.5m above the starting point in soil complete all as specified by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in l;ayers not exc 25 cm in soft and loose soil complete all as specified by Engineer-in-Charge
M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with colour choice by Engr-in-Charge and pigment and 100 mm thick cement concrete type D-2 1:4:8 using 40mm graded stone aggregate incl sand filling complete all as specified by Engineer-in-Charge
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out soft/loose soil complete all as specified by Engineer-in-Charge
M&L for 200mm sail-glazed stoneware drain pipes laid in trenches and jointed mplete complete all as specified by Engineer-in-Charge
M&L for cement concrete 1 : 4 : 8, type D2, using 40mm graded stone aggregates incl beding, packing under and haunching against the sides for 200mm internal dia of pipes, after they are laid and tested complete all as specified (thickness of concrete bed 100mm) complete all as specified by Engineer-in-Charge.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section) in cement concrete 1 : 2 : 4 type B1 using 20mm graded stone aggregate finished smooth and reforming benching as required for 150mm dia pipes complete all as specified by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified by Engineer-in-Charge.
M&L for coloured ceramic tiles (600x300mm)x7mm thick on vertical surfaces on skirting dados and risers to steps etc including 10mm thick cement mortar redering CM 1:4 complete all as specified by Engineer-in-Charge
S&F Chromium plated shower roses with or without swivel joints, 100mm X100 mm size, including fixing to steel pipe or union complete all as specified by Engineer-in-Charge
S&f in Toilet paper holder of vitreous china fixed to wall with chromium plated brass screws complete all as specified by Engineer-in-Charge
S & F in Brass CP wall mixer for mixing hot & Cold water screwed down for iron pipe and fixed complete all as specified by Engineer-in-Charge
S & F in Brass CP wash hand basin mixer for mixing hot & Cold water screwed down for iron pipe and fixed complete all as specified by Engineer-in-Charge
S&F in Towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/Plastic cleats.(Minimum weight 190gms) complete all as specified by Engineer-in-Charge
S&F in vitreous china wash down water closet pan (pedestal pattern white including fixing bolt flushing cistern and flush pipe and including plastic water closet seat black closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified by Engineer-in-Charge.
S & F in vitreous china wash basin white flat back size 630x450mm excluding taps but including waste chain and plug and porcelam sotpper but including brackets complete all as specified by Engineer-in-Charge.
S & F in CP bib taps fancy type cast copper alloy with crutch or butterfly handle screwed down screwed for Irom pipe or for brass ferrule in repairs and 15mm bore complete all as specified by Engineer-in-Charge
S & F in 15mm bore angle valve fancy type chromium plated cast copper alloy high pressure with crutch or butterfly handle screwed ends for iron pipe or for union and fixed complete all as specified by Engineer-in-Charge
S & F two way angle valve chromium plated with long shank and cup complete all as specified by Engineer-in-Charge
S & F grating round 140mm size of PTMT(minimum wt 50 gms) complete all as specified by Engineer-in-Charge
S & F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified by Engineer-in-Charge
S&F Glass shelf assembly 450mm long 150mm wide complete all as specified and as directed
S &F Health foucet, CP brass with 1.50mm long flexible pipe including two way angle cock complete all as specified by Engineer-in-Charge
S&F Glass Corner Shelf 8mm thick including CP railing radius 300mm complete all as specified and directed by the Engineer-in-Charge.
M & L for Granite 20mm thick machine cut, bedded and jointed with grey cement over including 15mm thick screed bed in CM 1:6 complete all as specified by Engineer-in-Charge
M&L for Prelalminated particle board 18/19mm thick, exterior grade prelaminated both sides with decorative choice laminations in Kitchen cuboards and shutters of Kitchen cupboards / almirahs complete all as specified by Engineer-in-Charge
S&F continous (piano hinges, mild steel bright finish or electro galvanized width of flap 30mm when open complete all as specified by Engineer-in-Charge
S&F 40mm dia cup board knob fixed with nut screw and washer of mild steel bright finish complete all as specified by Engineer-in-Charge.
S & F (Fe 410-W(Gde-E250)quality-A) Framed work as in Doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing and painting complete all as specified by Engineer-in-Charge
S & F Pre-painted galvalume aluminum Zinc coating GI based Corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified by Engineer-in-Charge
Excavation any type of soil in foundation, post holes (or similar wks) each n.exc 0.50 cum, getting out returning/filling and removing earth or broken boulders and ramming earth around in layers n.exc 25 cms in any type of soils complete all as specified by Engineer-in-Charge.
M & L for PCC in fdn filling and mass conc 1:3:6 type C-2 (40 mm graded stone aggregate) complete all as specified by Engineer-in-Charge
S&F Powder coated 50 micron,anodised aluminium windows and ventilator shutters, fixed type without sash bars, etc;aluminium section weighing 0.55 kg/m includingnecessary joining cleats glazing clips rubber packing aluminium anodised snap beading screws etc ccomplete all as specified by Engineer-in-Charge
S&F Powder coated 50 micron,anodised aluminum frame for windows/ventilators with one or more rebates incl incl grills, jointing cleats for fixing etc complete all as specified by Engineer-in-Charge
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed stainless steel wire staple, complete all as specified by Engineer-in-Charge
Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified by Engineer-in-Charge
Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on Aluminium Frame as per specifications and drawing complete all as specified by Engineer-in-Charge
M& L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in near cement slurry in floors including 15mm thick screed bed in floor complete all as specified by Engineer-in-Charge
M & L for rendering 15mm thick in cement plaster 1: 4 on fair faces of brick work or concrete surfaces complete all as specified and as directed by the Engineer-in-Charge
Taking up or down 15 mm dia GI tubing and connections including cleaning for re-fixing or new pipes, complete all as specified and as directed Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 and the two GI lines should be minimum 5 cm apart from each other with or without using GI clamps (GI clamps inclusive in this item only and nothing extra should be paid for clamps)
S&F 15mm dia GI tubing medium grade with all fitting and fixed to wall and ceiling or laid in floors etc incl scaffolding, cutting chases in wall where ever required etc and then making the surface smooth by plastering wall with CM 1:4 complete all as specified directed by Engineer-in-Charge Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+4 and the two GI lines should be minimum 5 cm apart from each other with or without using GI clamps (GI clamps inclusive in this item only and nothing extra should be paid for clamps)
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in foundation including rafts, footing, foundation beams, plinth beams, lintel band, bases for columns, etc and mass concrete complete all as specified directed by Engineer-in-Charge
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified directed by Engineer-in-Charge
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in beams, cantilevers, bressumers, lintels etc complete all as specified directed by Engineer-in-Charge.
M&L for RCC Design mix M-25 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies,desk slaby and in shelves and the like complete all as specified .
M & L for mild steel bar 10mm dia and over cut to length,bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified directed by Engineer-in-Charge. .
Ditto as per item descriped in above but 6mm to 8mm dia as in stirrups and binders complete all as specified directed by Engineer-in-Charge. .
M&L formwork to sides of concrete foundation, footing, bases of columns, rafts and raft beams, sides and plinth beams; and similar work; vertical or to batter, rough finised surface of concrete complete all as specified directed by Engineer-in-Charge. .
M&L for formwork to side and soffits of floor or roof beam, lintel, fair finished flat surface of concrete complete all as specified directed by Engineer-in-Charge. .
M&L for formwork to sides of pillars, posts, columns, fair finished, rectangular, square or polygonal surface of concrete complete all as specified directed by Engineer-in-Charge. .
M&L for formwork to soffits of suspended slabs such as roof slabs,floor slabs, landings and similar work; n.exc 200mm thick fair finished concrete surface complete all as specified directed by Engineer-in-Charge. .
M&L for sand filling in floors or pavings, laid in layers n.exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified directed by Engineer-in-Charge. .
M&L for rendering 15mm thick in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces firnished een and smooth without using extra cement with using water proofing compound complete all as specified directed by Engineer-in-Charge.
M&L for rendering 15mm thick in CM 1:6 on fair faces or other than fair faces of brick work or concrete surfaces of walls firnished een and smooth withoutusing extra cement complete all as directed
M & L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement incl scafolding etc, complete all as specified.
M&L for cement concrete 75mm thicktype C-2 1:3:6 (40mm graded aggregate)as in plinth protection and paths laid in alternative panel.
Supply only integral water proofing compound complete all as specified and as directed.
S&F Cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access doors for 100mm bore pipe complete all as specified directed by Engineer-in-Charge. .
S&F Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors or fixed to walls all as directed for 100mm bore pipe of sand cast complete all as specified directed by Engineer-in-Charge. .
S&F Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame and fixing with ancher bolts complete all as specified directed by Engineer-in-Charge.
S&F 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames complete all as specified directed by Engineer-in-Charge. .
S&F MS butt hinges medium weight 100 mm size fixed with screws complete all as specified directed by Engineer-in-Charge. .
S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws complete all as specified directed by Engineer-in-Charge. .
S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with MS screws complete all as specified directed by Engineer-in-Charge. .
Supply and fix steel ventilator with top hung shutter including hinges, steel peg stay, complete half fixed glazed and half openable glazed complete all as specified and directed (Glass shall be measured and paid separately).
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified directed by Engineer-in-Charge. .
S&F Sheet glass pin head type, 3.0mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified directed by Engineer-in-Charge. ..
S&F in vitreous China squatting pan, 'orissa' pattern WC size 580 x 440 mm white with integral foot rest complete all as specified directed by Engineer-in-Charge. ..
S&F in 100 mm dia CI 'P' or 'S' trap complete all as specified directed by Engineer-in-Charge.
S&F in 10 Ltr PVC valveless, syphonic action type flushing cistern low level with inlet, ball valve, float and handle including brackets and PVC out let sutaible for IWC complete all as specified directed by Engineer-in-Charge.
Supply and fix galvanized steel tubing, 20 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed
Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-O(using 12.5 mm graded aggregate) as required for conceled water tubing etc cutting exceeding 10cm girth but not exc. 20 cm all as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specifed as direted by Engr-in-charge.
Material and labour for rotational moulded polyethylene water storage tanks 1000 lts capacity, double layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description complete all as specified directed by Engineer-in-Charge. .
Supply and fixed Ball valves, high pressure of brass with epoxy coated aluminium rod and high density plastic ball screwed for 20mm bore GI pipe of having minimum weight 210gms complete all as specified directed by Engineer-in-Charge.
S & F in vitreous china wash hand basin (flat back) white of size 550x400mm long incl fixing waist pipe and chromium plated brass waist fitting and a pair of mild steel angle iron brackets of suitable size complete all as specified
Supply only 15 mm dia pillar taps, fancy type brass with capstan head chromium plated screwed down high pressure with or without lettered “hot/cold” with long screwed shank and flynut screwed complete all as specified
Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 compolete all as specified and directed.
M&L for roof treatment as per the description below including dismantling/taking down existing roof treatment complete:- a) preparation of roof surfaces by removing all loose material /dust extra for carrying out water proofing treatment. b) Apply bituminous primer @ 0.3 ltr/Sqm (conforming to IS-3384) on prepared surfaces. After drying of primer apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm of prepared surfaces. c) Laying APP (Atatic Polypropylene) modified five layered membrane 3 mm thick and weighing not less than 4 Kg/Sqm with centre core 160 GSM/ Sqm ; core reinforced and laid with 75 mm side overlap and 150 mm end lap. The membrane shall be laid with LPG torch application and overlaps sealed and finished neatly as per the manufacturer specification apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm and apply two coat of silver shield bitumestic aluminum paint all as specified
M&L for 300mm bore DWCPE drain pipes laid in trenches and jointed in CM 1:1 with spun yarn complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate in concrete bedding to drain pipes including packing under haunching against the sides of pipes after they are laid and tested for 300 mm bore pipe complete all as specified and directed.
S & F precast fibre reinforced cement concrete Manhole cover including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mmx75mm omplete all as specified and as directed.
S&f exhaust fans metal body, AC single phase 230/240 V of size 300 mm sweep with lorever shutter for fixing of exhaust fan complete all as directed by Engr-in-Charge.
S&f fresh air fan PVC body AC single phase 230/240 V of size 230 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed by Engr-in-Charge.
S & F water heater storage type Geyser vertical type with suitable size of fastner and including provision and connecting up of SS braidedpipe with adopter for inlet and outlet wwater connection having edjustable knob for temperature control and and, inner tank material of superior glass line tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity, should be glass line coated, capacity 25 Ltrs, having heating element 1.5 KW and not less than 5 star rating, suitable for ,230 volt, 50 Hz electric supply complete all as specified by Engineer-in-Charge
Taking down old MCCB , TPN DBs , & main switch/ enclosure box any light fitting anyh type of any make and type from the site and making good surface complete all as specified by Engineer-in-Charge
Taking down old submain wiring of any size and make from the site and making good surfacecomplete all as specified by Engineer-in-Charge
Supply and fix Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed)/ Surface in walls complete all as specified by Engineer-in-Charge
Supply and fix Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls complete all as specified by Engineer-in-Charge
Supply and fix Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed)/surface in walls all as specified and as directed. Note:- PVC rigid conduit ISI marked FRLS Grade
Supply & fix factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623 complete all as specified by Engineer-in-Charge.
M&L MCCB 125 Amps, 16 KA , 4P, 415 Volts, 50Hz , with thermal magnetic setting complete all as specified by Engineer-in-Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified by Engineer-in-Charge
M&L MCB SPN 40 Amp "C " curve complete all as specified by Engineer-in-Charge
M&L MCB SP 6 to 32 Amp "C" curve complete all as specified by Engineer-in-Charge.
S&F branded steel sheet MCCB enclosure box along with 160 A, 4 pole 16 ka MCCB, completely connected with copper thimble and with all accessories cocomplete all as specified by Engineer-in-Charge
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 25x4 mm thick galvanised strip duly fixed on suitable size of porcelain/ PVC insulator complete all as specified by Engineer-in-Charge
Taking down carefully copper/aluminium point wiring from wooden battan or conduits (light, fan, socket or power) complete including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc complete all as specified by Engineer-in-Charge.
M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall & including rigid PVC conduit 20 mm dia FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following :
One light/fan/bell point controlled by one by one way switch ( switch to be measured and paid separtely)
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 4 sqmm FRLS 1100 Volts in New PVC concealed conduit in new M S steel terminal boxes modular including one run of using 4 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, complete all as specified by Engineer-in-Charge
M&L for sub main wiring with two single core FRLS stranded copper conductor cable 1100 volts grade of size 4.0 sqmm and one single core FRLS stranded copper conductor cable 4 sqmm for earth wire in and including medium grade PVC concealed conduit with all fittings complete all as specified by Engineer-in-Charge
M&L switch piano flush type 5 Amp SP one way ISI marked complete all as specified by Engineer-in-Charge
M&L switch piano flush type 15 Amp SP one way ISI marked complete all as specified by Engineer-in-Charge
M&L bell push,flush type,5 amp ISI marked complete all as specified by Engineer-in-Charge
M&L socket outlet 5 pin 5 Amp flush type ISI marked complete all as specified by Engineer-in-Charge
M&L socket outlet 2 in 1,3 pin 5/15 Amps ISI marked complete all as specified by Engineer-in-Charge
M&L ceiling rose 3 phase PVC polycorbonate,isolated body. complete all as specified by Engineer-in-Charge
S & F electronic fan regulator 5 step ISI marked connecting complete all as specified by Engineer-in-Charge
M&L angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete all as specified by Engineer-in-Charge
S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified by Engineer-in-Charge.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixedcomplete all as specified by Engineer-in-Charge
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 900 lm system lumen output with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified by Engineer-in-Charge
Supply and fix 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified by Engineer-in-Charge
Supply and fix 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete all as specified by Engineer-in-Charge
M&L for breaking the old existing wall and making provn of a round hole for fixing of 300 mm sweep exhaust fan including making good to the disturbed wall/ portion and matching with existing colour.complete all as specified by Engineer-in-Charge
Supply and fix MCB DB SPN 4 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified by Engineer-in-Charge
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. strip 25x4 mm from earth electrode to the earth test point of galvanized Iron/steel of size 75 x 75 x 25 mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe Med grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified by Engineer-in-Charge
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. strip from earth electrode to the earth test point of galvanized Iron/steel of size 75 x 75 x 25 mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe Med grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
Material, labour jointing & testing XLPE insulated armoured heavy duty electric cable with standard aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 core including making connection with suitable size of cable gland, aluminium lugs etc complete including taking down old U/S cable complete all as specified by Engineer-in-Charge
Supplying, laying sub class 'B' bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified by Engineer-in-Charge
Supply & Fixing in replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm diacomplete all as specified by Engineer-in-Charge
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 10 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed.
Note :- Total amount of Sch of credit is Rs. 53788.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
M/S ANIL KUMAR
V r traders
L G BUILDERS
V M CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .