Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L1 | Accepted-AOC LOWEST BIDDER FOR THE WORK | |
| 2 | L2₹14.8 L+₹56,791 (3.98%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹14.9 L+₹63,476.20 (4.45%)Rejected-AOC 29 GANDHI NAGAR VETERINARY COLLEGE ROAD BIKANER 334001 RAJ | BIKANER | RAJASTHAN | 334001 | L3 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹15.0 L+₹71,003.20 (4.97%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹15.5 L+₹1.2 L (8.69%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN THE LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹41,220
Closing Date
3 Dec 2020, 6:00 pmClosed
CWE BHOPAL
HQ CWE BHOPAL, SI LINES, BHOPAL, PIN-462001
SPECIAL REPAIR TO OTM ACCN BLDG NO EM-93 (OR LIVING) OF 15 MED REGT AT NASIRABAD
2020_MES_392992_1
83585/E8
Open Tender
Civil Works
Item Rate
180 days
NASIRABAD
AS PER NIT CONDITIONS
4 documents required · 4 mandatory
₹500
GE NASIRABAD
₹41,220
Yes
6 Jan 2021
7 Nov 2020
5 Dec 2020
7 Nov 2020
3 Dec 2020
21 Nov 2020
Amount
Taking down cement or cement lime plaster on stone/brick wall, ceiling incl. Raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering in cement mortar (1:6), 15mm thick on stone masonary surfaces finished fair and even complete all as specified and directed
M&L for rendering 15mm thick in CM 1:4 on stone masonry, external surfaces finished fair & even complete all as specified and directed
M&L for preparation new decorated surfaces of walls and providing two coat of cement base paint complete all as specified and directed.
M&L for preparation old decorated surfaces of walls and providing one coat of cement base paint complete all as specified and directed.
M&L for complete removal of existing treatment and preparation wall surfaces and applying two coats of oil bound distemper over wall care of putty complete all as specified and directed Note: Thickness of putty shall be as per manufacturer instructions.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over wall care putty complete all as specified and directed Note: Thickness of putty shall be as per manufacturer instructions
M&L for preparation of old wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for old concrete surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Demolition of cement concrete (unreinforeced) in floors and paving n.exc 15cm thickness (above or below ground level) complete all as specified and directed.
M&L for machine cut Kota stone slab flooring of size not less than 550X550mmX18-20mm thick over 15mm thick screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed 10mm thick in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing & polishing complete all as spd & directed.
M&L for cement 25 mm thick PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in sub base complete all as specified & directed.
M&L PCC (1:3:6) type C-1 using 20mm graded stone aggregate 50mm thick as in plinth protection finished fair even laid in alternate bays n.exc 2m in length all as specified and directed.
Dismantling of ceiling board/lathing any thickness including frame work complete all as specified and directed.
Providing & Fixing false ceiling with Everest Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30 mm thick sheet, spaced at 1200 mm c/c and cross "T" of size 15x32 mm made of 0.30 mm sheet, 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size15x32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20 mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, all complete at all heights as per direction of Engineer-in-charge.
Dismantling Asbestos Cement (corrugated, semi corrugated, etc) sheets in roof covering complete all as specified & directed.
S & F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/ Lor J type hook complete all as specified & directed.
S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/ Lor J type hook complete all as specified & directed.
S & F second class HW 35mm thick, factory made, plain framed, panelled shutter (Three panels) with panels of 9mm thick BWP grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive conforming to IS-710. The size of rails & style shall be as per IS-1003 (part-I) kiln seasoned & chemically pressure treated complete all as per specified and directed.
Supply and fixing for 2nd class HW 35 mm thick, gauged and skeleton shutters (Three Panels), factory made open rebated and prepare to receive glass, gauge etc (with sash bar), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. Size of members of shutter shall be as specified in SSR 2009 Part-I, section 8 clause Member shall be kiln seasoned & chemically pressure treated complete all as specified and directed.
S & F Steel window factory made, out of MS hollow section 79mm x 39mmx1.6mm thick frame with double shutter (glazed & wiregauged shutters) made out of Z section using flush butt welding and tennon riveting all as per IS 1038/83, dobby hinges shall be provided to both shutters, Locking arrangements as per sample approval by GE, provided with knob, 10mm MS square bars in grill, Z section handle 100mm size and 150mm long hook & eye welded to frame and shutter, four Nos lugs welded to frame inculding necessary flat iron beading for securing wire gauge etc including holes, cutting holes for hold fast and making good in PCC 1:2:4 type B-1 including synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and directed. Note : Wire mesh and sheet glass shall be measured & paid separately under respective items.
S & F aluminium handle fabricated type, anodised 150mm size conforming to IS complete all as specified and directed.
S & F 300mm long aluminium alloy, anodised, sliding door bolts with hasps, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F aluminium, anodised, barrel tower bolt of extruded section, ISI marked, 150 mm long complete all as specified and directed.
S&F mild steel butt hinges, medium weight, cold rolled, ISI marked of size 100 mm, complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm and n.exc 4.00 Sqm each and removing from site complete and making good disturbed surfaces of wall in CM (1:3) all as specified and directed.
Taking down unserviceable chowkhats or frame with shutters (without taking off shutters from the frames) of any description exc 1.50Sqm and removing from site and making good disturbed surfaces of wall in CM 1:3 complete all as specified & directed. (For windows and ventilators)
M & L for preparation of new wooden surface over 10cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surface over 10cm width or grith & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as spd & directed.
M & L for rolled mild steel work angle iron as in door frame and other similar work confirming to Fe-290 or Fe-330 including complete all as specified and directed.
S&F in repairs fancy type 20mm dia SS curtain rods fixed to bracket complete all as spd & directed.
S&F decorative type knobs with bracket of Stainless Steel fixing at end of curtain rod complete al as spd & directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed with wire staples complete all as spd & directed.
S&F 3.00 mm thick sheet glass, ordinary quality & glazing with oil putty not exc 0.50 Sqm each pane complete all as spd & directed.
Demolition of stone/brick masonry built in cement or cement lime mortar all as specified and directed.
M&L for brick work with flyash bricks straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Ditto all as per item no 37.00 above item except brick complete all as specified and directed.
M&L providing chequered cement concrete coloured tiles 25cm x 25cm x 22 mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment laid over and including screed bed or bedding layer 20 mm thick in cm 1:4 as in floors complete all as specified and directed.
M & L for 75 mm thick PCC 1:4:8 type D-2, using 40 mm graded stone agg as in sub base etc complete all as specified and directed.
M & L PCC 1:2:4 type B-2, using 40 mm graded stone agg as in surface channel & drain etc complete all as specified and directed.
Taking down shutters of any description exc 1.00 Sqm but n. exc 2.00 sqm each leaf and removing from site Complete all as specified and directed
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, holders, regulators, sockets etc., removing materials from site.
Disconnecting unserviceable sub main wiring/service connection of any size and including conduit/casing caping of any type and accessories and removing from site and making good the disturbed surfaces.
Taking down MCB DB's complete with MCB's/Isolator etc removing materials from site and making good disturbed surface of walls, floors etc.
M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher complete with all PVC conduit accessories and sunk type anodised terminal box 1.2 mm thick with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories for:-
One light point/bell point controlled by one, one way switch.
One ceiling fan/exhaust fan point controlled by one, one way switch.
One three pin 5 Amp socket on same board with other switches.
One 3 pin 5 Amp socket on independent board.
Ditto all as per item No. 46.04 here-in-before but with 2.5 Sqmm, for one 5 pin 5/15 Amp socket on independent board including 2.5 Sqmm stranded copper conductor (FRLS) PVC insulated green in colour as continous earth conductor connected to common earth.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed multistranded (FRLS) copper conductor cable of size 6.00 Sqmm LT, 1100 volts grade, drawn through and including 25 mm dia or higher PVC non metallic concealed conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor.
S&F Switch piano, flush type, single pole, one way, 5 Amps, 240 volt, 50Hz, AC, complete all as specified and as directed by Engr-in-Charge.
S&F switch piano flush type 15 amps, single pole one way 240 volts complete all as speciied and directed by Engr-in-Charge.
S&F Socket outlet 3 Pin 5/6 Amp flush type complete all as speciied and directed by engr-in-Charge.
S&F socket outlet 2 in 1,multipurpose 3 pin 15/16 Amp flush type complete all as speciied and directed by Engr-in-Charge.
S&F ceiling fan regulator electronic flush , stepped (four step) 230 Volts AC complete all as speciied and directed by Engr-in-Charge.
S&F ceiling rose surface bakelite 3 terminals 63.5 x 17 mm complete all as speciied and directed by engr-in-Charge
S&F of lamp holder PVC/polycarbonate type with back plate complete all as speciied and directed by Engr-in-Charge.
S&F LED box type tube light fitting 20 watt made up of CRCA sheet with pre wired double sided connections including 1x20 watt retrofit LED tube rod with extruded aluminium body , PC diffuser and inbuilt driver , double sided connection, complete with all accessories internally prewired . Make Crompton Cat Part No LTT8-20 for tube , IGP161LT8-16 for batten or equivalent model of Philips/Wipro/Havells
Supply and fixing and testing energy saving street light luminaire 15 watt LED , pressure die cast housing with high power LED as lighting source and lens embedded PC cover with IP 66 protection incl connecting with three core copper flexible wire from ceiling rose to connector of light fitting complete all as specified and directed by Engr-in-Charge. Make : Havells, Cat Part No. ENDURAPEARLSL15WLED757SASYTOPC, or equivalent model of Crompton/Philips
Supply and fixing street light bracket made of 32 mm GI pipe , 1.2 mtr lenght fixed with two nos of clamp , nut and bolts complete all as specified and directed.
Taking down existing ceiling fan , dismantling blades and refixing after cleaning incl conecting up with three core flexible cable from ceiling rose to fan.
S&F of MCB distribution board single pole & neutral (SPN) 08 way, IP-43 double door metal, double made out of CRCA sheet steel , factory made powder coated with 200 amp rated insulated bus bars , shrouded neutral bars, earth bars , made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCB's complete all as specified and directed . Make: Legrand/Schneider/Seimens Note: MCB DB and MCB SP/SPN will be of same make.
S&F of MCB distribution board single pole & neutral (SPN) 12 way, IP-43 double door metal, double made out of CRCA sheet steel , factory made powder coated with 200 amp rated insulated bus bars , shrouded neutral bars, earth bars , made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCB's complete all as specified and directed . Make: Legrand/Schneider/Seimens Note: MCB DB and MCB SP/SPN will be of same make.
S & F of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge. . Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S & F of MCB SP, 240 volt, 40 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge. . Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S & F of MCB SPN, 240 volt, 40 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge by Engr-in-Charge. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S & F of MCB SPN, 240 volt, 63 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge by Engr-in-Charge. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 incl dismantling of old unsv existing earthing .
Note for all items: All items shall be executed as specified and directed by Engr-in-charge.
M/s Jai Jinendra Constructions
MITTAL ENTERPRISES
kirtiman traders
M/s SUNIL ENTERPRISES
M/S JAGDISH PRASAD AIRUN
SHREE BALAJI TRADING CORPORATION
PD GUPTA AND COMPANY
M/S HARI CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .